984 resultados para Magnetic recording materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nowadays, authentication studies for paintings require a multidisciplinary approach, based on the contribution of visual features analysis but also on characterizations of materials and techniques. Moreover, it is important that the assessment of the authorship of a painting is supported by technical studies of a selected number of original artworks that cover the entire career of an artist. This dissertation is concerned about the work of modernist painter Amadeo de Souza-Cardoso. It is divided in three parts. In the first part, we propose a tool based on image processing that combines information obtained by brushstroke and materials analysis. The resulting tool provides qualitative and quantitative evaluation of the authorship of the paintings; the quantitative element is particularly relevant, as it could be crucial in solving authorship controversies, such as judicial disputes. The brushstroke analysis was performed by combining two algorithms for feature detection, namely Gabor filter and Scale Invariant Feature Transform. Thanks to this combination (and to the use of the Bag-of-Features model), the proposed method shows an accuracy higher than 90% in distinguishing between images of Amadeo’s paintings and images of artworks by other contemporary artists. For the molecular analysis, we implemented a semi-automatic system that uses hyperspectral imaging and elemental analysis. The system provides as output an image that depicts the mapping of the pigments present, together with the areas made using materials not coherent with Amadeo’s palette, if any. This visual output is a simple and effective way of assessing the results of the system. The tool proposed based on the combination of brushstroke and molecular information was tested in twelve paintings obtaining promising results. The second part of the thesis presents a systematic study of four selected paintings made by Amadeo in 1917. Although untitled, three of these paintings are commonly known as BRUT, Entrada and Coty; they are considered as his most successful and genuine works. The materials and techniques of these artworks have never been studied before. The paintings were studied with a multi-analytical approach using micro-Energy Dispersive X-ray Fluorescence spectroscopy, micro-Infrared and Raman Spectroscopy, micro-Spectrofluorimetry and Scanning Electron Microscopy. The characterization of Amadeo’s materials and techniques used on his last paintings, as well as the investigation of some of the conservation problems that affect these paintings, is essential to enrich the knowledge on this artist. Moreover, the study of the materials in the four paintings reveals commonalities between the paintings BRUT and Entrada. This observation is supported also by the analysis of the elements present in a photograph of a collage (conserved at the Art Library of the Calouste Gulbenkian Foundation), the only remaining evidence of a supposed maquete of these paintings. The final part of the thesis describes the application of the image processing tools developed in the first part of the thesis on a set of case studies; this experience demonstrates the potential of the tool to support painting analysis and authentication studies. The brushstroke analysis was used as additional analysis on the evaluation process of four paintings attributed to Amadeo, and the system based on hyperspectral analysis was applied on the painting dated 1917. The case studies therefore serve as a bridge between the first two parts of the dissertation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: There is no study relating magnetic resonance imaging (MRI) to ultrasound (US) findings in patients with Schistosomiasis mansoni. Our aim was to describe MRI findings inpatients with schistosomal liver disease identified by US. METHODS: Fifty-four patients (mean age 41.6±13.5years) from an area endemic for Schistosomiasis mansoni were selected for this study.All had US indicating liver schistosomal fibrosis and were evaluated with MRI performed witha 1.5-T superconducting magnet unit (Sigma). RESULTS: Forty-seven (87%) of the 54 patientsshowing signs of periportal fibrosis identified through US investigation had confirmed diagnosesby MRI. In the seven discordant cases (13%), MRI revealed fat tissue filling in the hilar periportalspace where US indicated isolated thickening around the main portal vein at its point of entryto the liver. We named this the fatty hilum sign. One of the 47 patients with MRI evidence ofperiportal fibrosis had had his gallbladder removed previously. Thirty-five (76.1%) of the other46 patients had an expanded gallbladder fossa filled with fat tissue, whereas MRI of the remainingeleven showed pericholecystic signs of fibrosis. CONCLUSIONS: Echogenic thickening of thegallbladder wall and of the main portal vein wall heretofore attributed to fibrosis were frequentlyidentified as fat tissue in MRI. However, the gallbladder wall thickening shown in US (expandedgallbladder fossa in MRI) is probably secondary to combined hepatic morphologic changes inschistosomiasis, representing severe liver involvement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although cryptococcal infections begin in the lungs, meningoencephalitis is the most frequently encountered manifestation of cryptococcosis among individuals with advanced immunosuppression. As the infection progresses along the Virchow-Robin spaces, these structures may become dilated with mucoid material produced by the capsule of the organism. We report a case of a 24-year-old man with cryptococcal meningoencephalitis in which magnetic resonance imaging showed clusters of gelatinous pseudocysts in the periventricular white matter, basal ganglia, mammillary bodies, midbrain peduncles and nucleus dentatus with a soap bubble appearance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present dissertation focuses on the research of the recent approach of innovative high-temperature superconducting stacked tapes in electrical ma-chines applications, taking into account their potential benefits as an alternative for the massive superconducting bulks, mainly related with geometric and me-chanical flexibility. This work was developed in collaboration with Institut de Ciència de Ma-terials de Barcelona (ICMAB), and is related with evaluation of electrical and magnetic properties of the mentioned superconducting materials, namely: analysis of magnetization of a bulk sample through simulations carried out in the finite elements COMSOL software; measurement of superconducting tape resistivity at liquid nitrogen and room temperatures; and, finally, development and testing of a frequency controlled superconducting motor with rotor built by superconducting tapes. In the superconducting state, results showed a critical current density of 140.3 MA/m2 (or current of 51.15 A) on the tape and a 1 N∙m developed motor torque, independent from the rotor position angle, typical in hysteresis motors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report the magnetic resonance imaging diagnostic features in two cases with respectively lumbar epidural hematoma and cavernous hemangioma of the lumbar epidural space. Enhanced MRI T1-weighted scans show a hyperintense signal rim surrounding the vascular lesion. Non-enhanced T2-weighted scans showed hyperintense signal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This project aimed to engineer new T2 MRI contrast agents for cell labeling based on formulations containing monodisperse iron oxide magnetic nanoparticles (MNP) coated with natural and synthetic polymers. Monodisperse MNP capped with hydrophobic ligands were synthesized by a thermal decomposition method, and further stabilized in aqueous media with citric acid or meso-2,3-dimercaptosuccinic acid (DMSA) through a ligand exchange reaction. Hydrophilic MNP-DMSA, with optimal hydrodynamic size distribution, colloidal stability and magnetic properties, were used for further functionalization with different coating materials. A covalent coupling strategy was devised to bind the biopolymer gum Arabic (GA) onto MNPDMSA and produce an efficient contrast agent, which enhanced cellular uptake in human colorectal carcinoma cells (HCT116 cell line) compared to uncoated MNP-DMSA. A similar protocol was employed to coat MNP-DMSA with a novel biopolymer produced by a biotechnological process, the exopolysaccharide (EPS) Fucopol. Similar to MNP-DMSA-GA, MNP-DMSA-EPS improved cellular uptake in HCT116 cells compared to MNP-DMSA. However, MNP-DMSA-EPS were particularly efficient towards the neural stem/progenitor cell line ReNcell VM, for which a better iron dose-dependent MRI contrast enhancement was obtained at low iron concentrations and short incubation times. A combination of synthetic and biological coating materials was also explored in this project, to design a dynamic tumortargeting nanoprobe activated by the acidic pH of tumors. The pH-dependent affinity pair neutravidin/iminobiotin, was combined in a multilayer architecture with the synthetic polymers poy-L-lysine and poly(ethylene glycol) and yielded an efficient MRI nanoprobe with ability to distinguish cells cultured in acidic pH conditions form cells cultured in physiological pH conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, cellulose-based electro and ionic conductive composites were developed for application in cellulose based printed electronics. Electroconductive inks were successfully formulated for screen-printing using carbon fibers (CFs) and multi-walled carbon nanotubes (MWCNTs) as conductive functional material and cellulose derivatives working as binder. The formulated inks were used to fabricate conductive flexible and disposable electrodes on paper-based substrates. Interesting results were obtained after 10 printing passes and drying at RT of the ink with 10 % wt. of pristine CFs and 3% wt. of carboxymethyl cellulose (CMC), exhibiting a resistivity of 1.03 Ωcm and a resolution of 400 μm. Also, a resistivity of 0.57 Ωcm was obtained for only one printing pass using an ink based on 0.5 % wt. MWCNTs and 3 % wt. CMC. It was also demonstrated that ionic conductive cellulose matrix hydrogel can be used in electrolyte-gated transistors (EGTs). The electrolytes revealed a double layer capacitance of 12.10 μFcm-2 and ionic conductivity of 3.56x10-7 Scm-1. EGTs with a planar configuration, using sputtered GIZO as semiconducting layer, reached an ON/OFF ratio of 3.47x105, a VON of 0.2 V and a charge carrier mobility of 2.32 cm2V-1s-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on samples cross-sections from the Main Altarpiece of the Coimbra Old Cathedral, where a blue coating performed in 1685 is observed (that was partly covered with a Prussian blue-containing overpaint), the raw materials present in this coating were reproduced and studied. Blue areas were painted with smalt in oil, according to the contract signed by Manoel da Costa Pereira in 1684 and the analysis by Le Gac in 2009. Based on these, three batches of cobalt-based glasses (S1, S2 and S3) were heated and melted in alumina crucibles in the kiln. S1 contained 6.03 % of cobalt oxide, S2 contained 2.10 %, with the addition of 1.49 % of magnesium oxide, and S3 contained 6.82 % of cobalt oxide, with the addition of 4.63% of antimony trioxide. These batches were ground mechanically with water and manually with different vehicles stated in recipes. The results were studied by means of OM, SEM-EDS, X-Ray CT, Colorimetry and Vickers HT. Different binders were also produced and analyzed by means of μ-FTIR, in order to perform their characterization and obtain Standard Spectra. Since anhydrite was identified in the ground layers, gypsum from Óbidos was also characterized by XRD. The main goal of this thesis was to study all the raw materials present in the 1685-blue coating, in order to allow the historically accurate reconstruction of the layers build-up in the next future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine the consequences of the chronic use of systemic corticosteroids in children with juvenile rheumatoid arthritis by means of evaluating osteochondral effects depicted by magnetic resonance imaging. PATIENTS AND METHODS: We reviewed clinical and magnetic resonance imaging findings in 69 children (72 knees) with juvenile rheumatoid arthritis. Two groups were studied. Group I: 34 (49.3%) children had previous or current use of systemic corticotherapy (22 girls; 12 boys; mean age: 11.3 years; mean disease duration: 5.9 years; mean corticotherapy duration: 2.9 years; mean cumulative dose of previous corticosteroids: 5000 mg); Group II: 35 (50.7%) children had no previous use of corticosteroids (27 girls; 8 boys; mean age: 11.7 years; mean disease duration: 5.3 years). The groups were compared statistically. RESULTS: In the group that had received corticotherapy (Group I), osteochondral abnormalities were significantly correlated to long-standing disease (>3.5 years; p<0.001). This correlation was not found in the group that had no previous history of corticotherapy (Group II). No correlations were established between median dose of corticosteroids and magnetic resonance imaging findings. CONCLUSION: It is important to further investigate the long-term intra-articular effects of systemic corticotherapy to ensure that the side effects of the aggressive therapy will not be more harmful for the joints than the symptoms suffered over the natural course of the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cancer is a well-known disease with a significant impact in society not only due to its incidence, more evident in more developed countries, but also due to the expenses related to medical treat-ments. Cancer research is considered an increasingly logical science with great potential for the development of new treatment options. Advances in nanomedicine have resulted in rapid devel-opment of nanomaterials with considerable potential in cancer diagnostics and treatment. The combination of diagnosis and treatment in a single nano-platform is named theranostic. In this PhD thesis a theranostic system for osteosarcoma was proposed, composed by a magnetic core, a polymeric coating, and a chemotherapeutic drug. The presence of a specific targeting agent, in this case a monoclonal antibody, provides high specificity to the proposed theranostic system. For the core of the proposed theranostic system, stable aqueous suspensions of superparamagnetic iron oxide nanoparticles with an average diameter of 9 nm were produced. Chitosan-based poly-meric nanoparticles with a hydrodynamic diameter around 150 nm were successfully produced. Incorporation of iron oxide nanoparticles into the polymeric ones increased their hydrodynamic diameter to at least 250 nm. A monoclonal antibody specific for a transmembranar protein (car-bonic anhydrase IX) present in solid tumors was developed by hybridoma technology. Functional hybridomas producing the desired monoclonal antibodies were obtained. The proposed theranostic system functionality was evaluated in separated parts of its components. Uncoated and coated iron oxide nanoparticles with chitosan-based polymers generated heat under the application of an external alternating magnetic field. Uncoated iron oxide nanoparticles sta-bilized with oleic acid were able to enhance contrast in magnetic resonance imaging. Drug deliv-ery studies were conducted in chitosan-based polymeric nanoparticles without and with the in-corporation of iron oxide nanoparticles, demonstrating to be an effective drug delivery platform for doxorubicin. The theranostic system proposed in this PhD thesis is very promising for cancer theranostic, demonstrating to be applicable in solid tumors such as osteosarcoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Schizophrenic patients undergoing proton magnetic resonance spectroscopy show alterations in N-acetyl aspartate levels in several brain regions, indicating neuronal dysfunction. The present review focuses on the main proton magnetic resonance spectroscopy studies in the frontal lobe of schizophrenics. A MEDLINE search, from 1991 to March 2004, was carried out using the key-words spectroscopy and schizophrenia and proton and frontal. In addition, articles cited in the reference list of the studies obtained through MEDLINE were included. As a result, 27 articles were selected. The results were inconsistent, 19 papers reporting changes in the N-acetyl aspartate levels, while 8 reported no change. Methodological analysis led to the conclusion that the discrepancy may be due the following factors: (i) number of participants; (ii) variation in the clinical and demographic characteristics of the groups; (iii) little standardization of the acquisition parameters of spectroscopy. Overall, studies that fulfill strict methodological criteria show N-acetyl aspartate decrease in the frontal lobe of male schizophrenics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equity research report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite materials have a complex behavior, which is difficult to predict under different types of loads. In the course of this dissertation a methodology was developed to predict failure and damage propagation of composite material specimens. This methodology uses finite element numerical models created with Ansys and Matlab softwares. The methodology is able to perform an incremental-iterative analysis, which increases, gradually, the load applied to the specimen. Several structural failure phenomena are considered, such as fiber and/or matrix failure, delamination or shear plasticity. Failure criteria based on element stresses were implemented and a procedure to reduce the stiffness of the failed elements was prepared. The material used in this dissertation consist of a spread tow carbon fabric with a 0°/90° arrangement and the main numerical model analyzed is a 26-plies specimen under compression loads. Numerical results were compared with the results of specimens tested experimentally, whose mechanical properties are unknown, knowing only the geometry of the specimen. The material properties of the numerical model were adjusted in the course of this dissertation, in order to find the lowest difference between the numerical and experimental results with an error lower than 5% (it was performed the numerical model identification based on the experimental results).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)

Relevância:

20.00% 20.00%

Publicador: