990 resultados para K-ar


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on the fabrication and characterization of a ridge optical waveguide in an Er3+/Yb3+ co-doped phosphate glass. The He+ ion implantation (at energy of 2.8 MeV) is first applied onto the sample to produce a planar waveguide substrate, and then Ar+ ion beam etching (at energy of 500 eV) is carried out to construct rib stripes on the sample surface that has been deposited by a specially designed photoresist mask. According to a reconstructed refractive index profile of the waveguide cross section, the modal distribution of the waveguide is simulated by applying a computer code based on the beam propagation method, which shows reasonable agreement with the experimentally observed waveguide mode by using the end-face coupling method. Simulation of the incident He ions at 2.8 MeV penetrating into the Er3+/Yb3+ co-doped phosphate glass substrate is also performed to provide helpful information on waveguide formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neste trabalho utilizou-se a técnica fluorescência de raios X usando radiação síncrotron (SR-TXRF) para estudar, quantitativamente, o transporte de cloro, potássio e cálcio na hemolinfa, urina e túbulos de Malpighi (TM) em ninfas de quinto estágio do Rhodnius prolixus (R. prolixus), considerando a excreção destes elementos em diferentes dias após o repasto sanguíneo. R. prolixus é um dos principais vetores do Trypanosoma cruzi, agente causador da doença de Chagas. R. prolixus fornece um sistema modelo particularmente útil porque seus TMs tanto secretam quanto reabsorvem íons a taxas elevadas. Os TMs filtram a hemolinfa e secretam um líquido que é muitas vezes comparado com a urina primária em vertebrados. Os resultados obtidos mostram que a concentração de potássio na urina é substancialmente maior do que na hemolinfa. A concentração de cloro na hemolinfa é menor do que na urina, mas a diferença não é tão marcada como no caso do potássio. No caso do Rhodnius é razoável interpretar a elevada concentração de potássio na urina como adaptativo para o problema de excreção imediato do inseto. A concentração de cálcio nos TMs é substancialmente maior em comparação com os valores encontrados na hemolinfa e urina. Este resultado mostra que o cálcio é retido no corpo do R. prolixus e pouco eliminado. Os resultados obtidos estão coerentes com a literatura. Avaliou-se também o efeito no transporte de Cl, K e Ca após um repasto de sangue de coelho contaminado com HgCl2 de modo a avaliar o efeito da presença deste metal tóxico no balanço iônico nos fluidos de excreção urina e hemolinfa e também pelo principal órgão de transporte, os túbulos de Malpighi. As excreções de Cl e K pela urina são afetadas pela ingestão. Este resultado é esperado levando-se em consideração a ingestão de excesso de Cl através do HgCl2. O transporte de Cl, K e Ca na hemolinfa do Rhodnius prolixus não é afetada pela ingestão de HgCl2. Nos túbulos de Malpighi, as altas concentrações de Ca obtidas foram comparáveis àquelas encontradas nos insetos controle. Pode-se concluir que SR-TXRF é um método muito promissor para análises diretas, rápidas e confiáveis para a quantificação simultânea de elementos envolvidos na regulação do transporte e em todo o sistema excretor de insetos. Além disso, o estudo do transporte e a excreção de elementos no inseto Rhodnius prolixus abrem oportunidade para a maior compreensão de efeitos da poluição em espécies de invertebrados.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is shown that the locus of the f' + if '' plot in the complex plane, f' being determined from measured f '' by using the dispersion relation, looks like a semicircle very near the absorption edge of Ge. The semicircular locus is derived from a quantum theory of X-ray resonant scattering when there is a sharp isolated peak in f '' just above the K-absorption edge. Using the semicircular behavior, an approach is proposed to determine the anomalous scattering factors in a crystal by fitting known calculated values based on an isolated-atom model to a semicircular focus. The determined anomalous scattering factors f' show excellent agreement with the measured values just below the absorption edge. In addition, the phase determination of a crystal structure factor has been considered by using the semicircular behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

By using an Ar+ ion laser, a tunable Rh 6G dye laser(Linewidth : 0.5 cm(-1)) and a Coherent 899-21 dye laser as light sources and using a monochromator and a phase-locking amplifier, the optical properties of Eu3+ : Y2SiO5 crystal were detected. Persistent spectral hole burning (PSHB) were also observed in (5)Do-(7)Fo transition in the crystal at the temperature of 16 K. For 15 mW dye laser (Wavelength : 579.62 nm) burning the crystal for 0.1 s a spectral hole with about 80 MHz hole width were detected and the hole can been keep for longer than 10 h.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O difundido uso de perfis estruturais tubulares, principalmente devido às vantagens associadas ao comportamento estrutural e estético, levou a uma intensa utilização nos países da Europa, Sudeste Asiático, América do Norte e na Austrália. Países como Canadá, Inglaterra, Alemanha e Holanda fazem uso intensivo dessas estruturas e contam com uma produção corrente, industrializada e contínua com alto grau de desenvolvimento tecnológico. O aumento da oferta deste tipo de perfis, aliado a recentes pesquisas nesta área, leva o Brasil a se inserir neste cenário mundial. Entretanto, as normas brasileiras que regem o dimensionamento destes perfis ainda não se encontram atualizadas, principalmente no que tange ao dimensionamento de ligações de perfis tubulares. Considerando esta perspectiva, este trabalho apresenta uma análise de ligações tipo K e T com perfis tubulares circulares (CHS). Propõe-se estabelecer um quadro comparativo entre as formulações analíticas de dimensionamento proposta pelo Eurocode 3 Parte 1.8, 2 edição do guia de projeto de ligações tubulares do CIDECT, projeto de norma brasileira PN 02.125.03-004 e critérios de deformação limite. Para cada um dos tipos de ligações analisadas, desenvolveu-se um modelo em elementos finitos no programa Ansys, calibrado e validado com resultados experimentais e numéricos existentes na literatura. As não-linearidades física e geométrica foram incorporadas aos modelos, a fim de se mobilizar totalmente a capacidade resistente da ligação. A não-linearidade do material foi considerada através do critério de plastificação de Von Mises através de uma lei constitutiva tensão versus deformação bilinear. A não-linearidade geométrica foi introduzida no modelo através da Formulação de Lagrange Atualizado considerando-se a previsão de grandes deformações de forma a permitir a redistribuição de carregamento na ligação após o escoamento inicial. Esta dissertação propõe ainda, a modelagem de uma treliça planar constituída de perfis tubulares, objetivando estabelecer uma comparação entre um nó isolado e um nó da treliça planar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este artículo se ha realizado dentro del Proyecto de Investigación «Identidades y diversidad cultural en la Hispania Antigua: Bilingüismo y Cultura Epigráfica» (HUM 2006-13424-C04-02/Filo).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ta2O5 films are prepared on Si, BK7, fused silica, antireflection (AR) and high reflector (HR) substrates by electron beam evaporation method, respectively. Both the optical property and laser induced damage thresholds (LIDTs) at 1064 nm of Ta2O5 films on different substrates are investigated before and after annealing at 673 K for 12h. It is shown that annealing increases the refractive index and decreases the extinction index, and improves the O/Ta ratio of the Ta2O5 films from 2.42 to 2.50. Moreover, the results show that the LIDTs of the Ta2O5 films are mainly correlated with three parameters: substrate property, substoichiometry defect in the films and impurity defect at the interface between the substrate and the films. Details of the laser induced damage models in different cases are discussed.