960 resultados para Intervertebral Disc Displacement
Resumo:
Purpose: To analyze in an experimental animal model the effect of 4 different levels of stents-graft oversizing on non-atherosclerotic aortas such as those found in young individuals who undergo stent-graft repair for traumatic aortic injuries. Methods: The diameter of the porcine thoracic aorta is similar to the aorta of young adults (18-20 mm), so 25 pigs were randomized into 5 groups: 1 control (without stent-graft) and 4 oversizing groups (A: 10%-19%, B: 20%-29%, C: 30%-39%, and D: >40%). Two types of biomechanical tests were performed on all aortas 4 weeks after endoprosthesis deployment. Results: The results of the detachment test, which analyzed the strength necessary to remove the stent-graft from the aorta, were similar in the 4 groups (A: 42 N, B: 41 N, C: 46 N, and D: 46 N). However, 2 aortas ruptured during the tests (groups C and D). The second test was performed in 3 aortic segments. Maximum shear strength, maximum stress, and maximum tension supported by the aortic wall had a negative and linear correlation with oversizing. There were significant differences in all 4 groups when compared with the control group. Strain, which reflects the elastic properties of the aortic wall, was very similar in all 4 groups, but a great difference was found when compared with the control group (p<0.0001). Conclusion: The study showed an important subacute change in the biomechanical properties of the aortic wall after implantation of an oversized endoprosthesis. This weakness of the aortic wall was confirmed by 2 ruptures during the detachment test. These results partially explain the interaction of stent-grafts with non-atherosclerotic thoracic aortas and may serve as a basis for further studies and the development of specific material to be used in vascular trauma and young patients. J Endovasc Ther. 2011; 18: 576-584
Resumo:
A novel flow-tagging technique is presented which was employed to measure gas velocities in the free stream of a shock tube. This method is based on the laser spectroscopic techniques of Laser-Enhanced Ionisation (LEI) and Laser-Induced Fluorescence (LIF). The flow in the shock tube is seeded with small amounts of sodium, and LEI is used to produce a substantial depletion of neutral sodium atom concentration in a well-defined region of the flow, by using two wavelength-resonance excitation and subsequent collisional ionisation. At a specific time delay, single-laser-pulse planar LIF is utilised to produce a two-dimensional (2-D) inverse image of the depleted tagged region downstream of the flow. By measuring the displacement of the tagged region, free stream velocities in a shock tube were determined. Large variations in the concentration of sodium seeded into the flow were observed and even in the presence of these large variations accurate free-stream velocity measurements were obtained. The experimentally determined value for velocity compares very well with the predicted velocity.
Resumo:
The St. Lawrence Island polynya (SLIP) is a commonly occurring winter phenomenon in the Bering Sea, in which dense saline water produced during new ice formation is thought to flow northward through the Bering Strait to help maintain the Arctic Ocean halocline. Winter darkness and inclement weather conditions have made continuous in situ and remote observation of this polynya difficult. However, imagery acquired from the European Space Agency ERS-1 Synthetic Aperture Radar (SAR) has allowed observation of the St. Lawrence Island polynya using both the imagery and derived ice displacement products. With the development of ARCSyM, a high resolution regional model of the Arctic atmosphere/sea ice system, simulation of the SLIP in a climate model is now possible. Intercomparisons between remotely sensed products and simulations can lead to additional insight into the SLIP formation process. Low resolution SAR, SSM/I and AVHRR infrared imagery for the St. Lawrence Island region are compared with the results of a model simulation for the period of 24-27 February 1992. The imagery illustrates a polynya event (polynya opening). With the northerly winds strong and consistent over several days, the coupled model captures the SLIP event with moderate accuracy. However, the introduction of a stability dependent atmosphere-ice drag coefficient, which allows feedbacks between atmospheric stability, open water, and air-ice drag, produces a more accurate simulation of the SLIP in comparison to satellite imagery. Model experiments show that the polynya event is forced primarily by changes in atmospheric circulation followed by persistent favorable conditions: ocean surface currents are found to have a small but positive impact on the simulation which is enhanced when wind forcing is weak or variable.
Resumo:
Because the structure of the spine is inherently unstable, muscle activation is essential for the maintenance of trunk posture and intervertebral control when the limbs are moved. To investigate how the central nervous system deals with this situation the temporal components of the response of the muscles of the trunk were evaluated during rapid limb movement performed in response to a visual stimulus. Fine-wire electromyography (EMG) electrodes were inserted into transversus abdominis (TrA), obliquus internus abdominis (OI) and obliquus externus abdominis (OE) of 15 subjects under the guidance of real-time ultrasound imaging. Surface electrodes were placed over rectus abdominis (RA), lumbar multifidus (MF) and the three parts of deltoid. In a standing position, ten repetitions of shoulder flexion, abduction and extension were performed by the subjects as fast as possible in response to a visual stimulus. The onset of TrA EMG occurred in advance of deltoid irrespective of the movement direction. The time to onset of EMC activity of OI, OE, RA and MF varied with the movement direction, being activated earliest when the prime action of the muscle opposed the reactive forces associated with the specific limb movement. It is postulated that the non-direction-specific contraction of TrA may be related to the control of trunk. stability independent of the requirement for direction-specific control of the centre of gravity in relation to the base of support.
Resumo:
A new method to measure Escherichia coil cell debris size after homogenization is presented. It is based on cumulative sedimentation analysis under centrifugal force, coupled with Sodium Dodecyl Sulfate-Polyacrylamide Gel Electrophoresis (SDS-PAGE) analysis of sedimented proteins. The effects that fermentation and homogenization conditions have on the resulting debris distributions were investigated using this method. Median debris size decreased significantly from approximately 0.5 mu m to 0.3 mu m as the number of homogenization passes increased from 2 to 10. Under identical homogenization conditions, uninduced host cells in stationary phase had a larger debris size than exponential cells after 5 homogenizer passes. This difference was not evident after 2 or in passes, possibly because of confounding intact cells and the existence of a minimum debris size for the conditions investigated. Recombinant cells containing protein inclusion bodies had the smallest debris size following homogenization. The method was also used to measure the size distribution of inclusion bodies. This result compared extremely well with an independent determination using centrifugal disc photosedimentation (CDS), thus validating the method. This is the first method that provides accurate size distributions of E. coli debris without the need for sample pretreatment, theoretical approximations (e.g. extinction coefficients), or the separation of debris and inclusion bodies prior to analysis. (C) 1997 John Wiley & Sons, Inc.
Resumo:
The purpose of this study was to evaluate the mid- and long-term results of percutaneous transhepatic cholangiography (PTC) and biliary drainage in children with isolated bilioenteric anastomotic stenosis (BAS) after pediatric liver transplantation. Sixty-four children underwent PTC from March 1993 to May 2008. Nineteen cholangiograms were normal; 10 showed intrahepatic biliary stenosis and BAS, and 35 showed isolated BAS. Cadaveric grafts were used in 19 and living donor grafts in 16 patients. Four patients received a whole liver, and 31 patients received a left lobe or left lateral segment. Roux-en-Y hepaticojejunostomy was performed in all patients. Indication for PTC was based on clinical, laboratory, and histopathologic findings. In patients with isolated BAS, dilation and biliary catheter placement, with changes every 2 months, were performed. Patients were separated into 4 groups according to number of treatment sessions required. The drainage catheter was removed if cholangiogram showed no significant residual stenosis and normal biliary emptying time after a minimum of 6 months. The relationship between risk factors (recipient`s weight < 10 kg, previous exposure to Cytomegalovirus, donor-recipient sex and weight relations, autoimmune disease as indication for transplantion, previous Kasai`s surgery, use of reduced liver grafts, chronic or acute rejection occurrence) and treatment was evaluated. Before PTC, fever was observed in 46%, biliary dilation in 23%, increased bilirubin in 57%, and increased gamma-glutamyltransferase (GGT) in 100% of patients. In the group with BAS, 24 of 35 (69%) patients had histopathologic findings of cholestasis as did 9 of 19 (47%) patients in the group with normal PTC. Of the 35 patients, 23 (65.7%) needed 1 (group I), 7 needed 2 (group II), 4 needed 3 (group III), and 1 needed 4 treatment sessions (group IV). The best results were observed after 1 treatment session, and the mean duration of catheter placement and replacement was 10 months. The primary patency rate was 61.2%, and the recurrence rate was 34.3% (group I). Seven patients (7 of 35; 20%) had their stricture treated with a second treatment session (group II). The average drainage time in group II was 24 months. During a period > 20 months, 4 patients (4 of 35; 11.4%) required 1 additional treatment session (group III), and 1 patient (1 of 35; 2.9%) had a catheter placed at the end of the study period (group IV). Drainage time in group I was significantly shorter than those in groups II, III, and IV (p < 0.05). There was no statistically significant relation between therapeutic response and the selected risk factors (p > 0.05). The majority of complications, such as catheter displacement and leakage, were classified as minor; however, 2 patients (5.7%) with hemobilia were noted. Complications increased according to the need for reintervention. In conclusion, balloon dilation and percutaneous drainage placement is safe and effective, and it has long-term patency for children with BAS after liver transplantation. Because of prolonged treatment time, reintervention may be necessary, thereby increasing the complication rate. Balloon dilation and percutaneous drainage placement should be considered as the first treatment option because of its minimally invasive nature.
Resumo:
Experimental data for E. coli debris size reduction during high-pressure homogenisation at 55 MPa are presented. A mathematical model based on grinding theory is developed to describe the data. The model is based on first-order breakage and compensation conditions. It does not require any assumption of a specified distribution for debris size and can be used given information on the initial size distribution of whole cells and the disruption efficiency during homogenisation. The number of homogeniser passes is incorporated into the model and used to describe the size reduction of non-induced stationary and induced E. coil cells during homogenisation. Regressing the results to the model equations gave an excellent fit to experimental data ( > 98.7% of variance explained for both fermentations), confirming the model's potential for predicting size reduction during high-pressure homogenisation. This study provides a means to optimise both homogenisation and disc-stack centrifugation conditions for recombinant product recovery. (C) 1997 Elsevier Science Ltd.
Resumo:
This study aimed to compare the resting energy expenditure (REE) of white and non-white severely obese Brazilian women. REE was examined in 83 severely obese Brazilian women (n = 58 white and 25 non-white) with mean (+/- SD) age 42.99 +/- 11.35 and body mass index 46.88 +/- 6.22 kg/m(2) who were candidates for gastric bypass surgery. Body composition was assessed by air displacement plethysmography (ADP) BOD PODO body composition system (Life Measurement Instruments, Concord, CA) and REE was measured, under established protocol, with an open-circuit calorimeter (Deltatrac II MBM-200, Datex-Ohmeda, Madison, WI, USA). There was no significant difference between the REE of white and non-white severely obese women (1,953 +/- 273 and 1,906 +/- 271 kcal/d, respectively; p = 0.48). However, when adjusted for fat free mass (MLG), REE was significantly higher in non-white severely obese women (difference between groups of 158.4 kcal, p < 0.01). REE in white women was positively and significantly correlated to C-reactive protein (PCR) (r = 0.41.8; P < 0.001) and MLG (r = 0.771; P < 0.001). In the non-white women, REE was only significantly correlated to MLG (r = 0.753; P < 0.001). The multiple linear regression analysis showed that skin color, MLG and PCR were the significant determinants of REE (R(2) = 0.55). This study showed that, after adjustment for MLG, non-white severely obese women have a higher REE than the white ones. The association of body composition inflammation factors and REE in severely obese Brazilian women remains to be further investigated.
Resumo:
Background & aims: Severe obesity imposes physical limitations to body composition assessment. Our aim was to compare body fat (BF) estimations of severely obese patients obtained by bioelectrical impedance (BIA) and air displacement plethysmography (ADP) for development of new equations for BF prediction. Methods: Severely obese subjects (83 female/36 mate, mean age = 41.6 +/- 11.6 years) had BF estimated by BIA and ADP. The agreement of the data was evaluated using Bland-Altman`s graphic and concordance correlation coefficient (CCC). A multivariate regression analysis was performed to develop and validate new predictive equations. Results: BF estimations from BIA (64.8 +/- 15 kg) and ADP (65.6 +/- 16.4 kg) did not differ (p > 0.05, with good accuracy, precision, and CCC), but the Bland- Altman graphic showed a wide Limit of agreement (- 10.4; 8.8). The standard BIA equation overestimated BF in women (-1.3 kg) and underestimated BF in men (5.6 kg; p < 0.05). Two BF new predictive equations were generated after BIA measurement, which predicted BF with higher accuracy, precision, CCC, and limits of agreement than the standard BIA equation. Conclusions: Standard BIA equations were inadequate for estimating BF in severely obese patients. Equations developed especially for this population provide more accurate BF assessment. (C) 2008 Elsevier Ltd and European Society for Clinical Nutrition and Metabolism. All rights reserved.
Resumo:
Three patients with progressive visual loss, chronic alcoholism and tabagism were submitted to a complete neuro-ophthalmic examination and to retinal nerve fiber layer (RNFL) measurements using optical coherence tomography (OCT) scanning. Two patients showed marked RNFL loss in the temporal sector of the optic disc. However, a third patient presented RNFL measurements within or above normal limits, based on the Stratus-OCT normative database. Such findings may be due to possible RNFL edema similar to the one that may occur in the acute phase of toxic optic neuropathies. Stratus-OCT was able to detect RNFL loss in the papillomacular bundle of patients with tobacco-alcohol-induced toxic optic neuropathy. However, interpretation must be careful when OCT does not show abnormality in order to prevent diagnostic confusion, since overestimation of RNFL thickness measurements is possible in such cases.
Resumo:
PURPOSE: To evaluate the impact of atypical retardation patterns (ARP) on detection of progressive retinal nerve fiber layer (RNFL) loss using scanning laser polarimetry with variable corneal compensation (VCC). DESIGN: Observational cohort study. METHODS: The study included 377 eyes of 221 patients with a median follow-up of 4.0 years. Images were obtained annually with the GDx VCC (Carl Zeiss Med, itec Inc, Dublin, California, USA), along with optic disc stereophotographs and standard automated perimetry (SAP) visual fields. Progression was determined by the Guided Progression Analysis software for SAP and by masked assessment of stereophotographs by expert graders. The typical scan score (TSS) was used to quantify the presence of ARPs on GDx VCC images. Random coefficients models were used to evaluate the relationship between ARP and RNFL thickness measurements over time. RESULTS: Thirty-eight eyes (10%) showed progression over time on visual fields, stereophotographs, or both. Changes in TSS scores from baseline were significantly associated with changes in RNFL thickness measurements in both progressing and nonprogressing eyes. Each I unit increase in TSS score was associated with a 0.19-mu m decrease in RNFL thickness measurement (P < .001) over time. CONCLUSIONS: ARPs had a significant effect on detection of progressive RNFL loss with the GDx VCC. Eyes with large amounts of atypical patterns, great fluctuations on these patterns over time, or both may show changes in measurements that can appear falsely as glaucomatous progression or can mask true changes in the RNFL. (Am J Ophthalmol 2009;148:155-163. (C) 2009 by Elsevier Inc. All rights reserved.)
Resumo:
Purpose: To compare the ability of Subjective assessment of optic nerve head (ONH) and retinal nerve fiber layer (RNFL) by general ophthalmologists and by a glaucoma expert with objective measurements by optical coherence tomography (Stratus OCT, Carl Zeiss Meditec Inc), confocal scanning laser ophthalmoscope (HRT III; Heidelberg Engineering, Heidelberg. Germany), and scanning laser polarimetry (GDx enhanced corneal compensation; Carl Zeiss Meditec Inc, Dublin, CA) in discriminating glaucomatous and normal eyes. Methods: Sixty-one glaucomatous and 57 normal eyes or 118 subjects Were included in the study. Three independent general ophthalmologists and I glaucoma expert evaluated ONH stereo-photographs. Receiver operating characteristic curves were constructed for each imaging technique and sensitivity at fixed specificity was estimated. Comparisons or areas under these curves (aROCs) and agreement (k) were determined between stereophoto grading and best parameter from each technique. Results: Best parameter from each technique showed larger aROC (Stratus OCT RNFL 0.92; Stratus OCT ONH vertical integrated area = 0.86; Stratus OCT macular thickness = 0.82; GDx enhanced corneal compensation = 0.91, HRT3 global cup-to-disc ratio = 0.83; HRT3 glaucoma probability score numeric area score 0.83) compared with stereophotograph grading by general ophthalmologists (0.80) in separating glaucomatous and normal eyes. Glaucoma expert stereophoto grading provided equal or larger aROC (0.92) than best parameter of each computerized imaging device. Stereophoto evaluated by a glaucoma expert showed better agreement with best parameter of each quantitative imaging technique in classifying eyes either as glaucomatous or normal compared with stereophoto grading by general ophthalmologists, The combination Of Subjective assessment of the optic disc by general ophthalmologists with RNFL objective parameters improved identification of glaucoma patients in a larger proportion than the combination of these objective parameters with Subjective assessment of the optic disc by a glaucoma expert (29.5% vs. 19.7%, respectively). Conclusions: Diagnostic ability of all imaging techniques showed better performance than subjective assessment of the ONH by general ophthalmologists, but not by It glaucoma expert, Objective RNFL measurements may provide improvement in glaucoma detection when combined with subjective assessment of the optic disc by general ophthalmologists or by a glaucoma expert.
Resumo:
Objective: To determine intraocular pressure (IOP)-dependent and IOP-independent variables associated with visual field (VF) progression in treated glaucoma. Design: Retrospective cohort of the Glaucoma Progression Study. Methods: Consecutive, treated glaucoma patients with repeatable VF loss who had 8 or more VF examinations of either eye, using the Swedish Interactive Threshold Algorithm (24-2 SITA-Standard, Humphrey Field Analyzer II; Carl Zeiss Meditec, Inc, Dublin, California), during the period between January 1999 and September 2009 were included. Visual field progression was evaluated using automated pointwise linear regression. Evaluated data included age, sex, race, central corneal thickness, baseline VF mean deviation, mean follow-up IOP, peak IOP, IOP fluctuation, a detected disc hemorrhage, and presence of beta-zone parapapillary atrophy. Results: We selected 587 eyes of 587 patients (mean [SD] age, 64.9 [13.0] years). The mean (SD) number of VFs was 11.1 (3.0), spanning a mean (SD) of 6.4 (1.7) years. In the univariable model, older age (odds ratio [OR], 1.19 per decade; P = .01), baseline diagnosis of exfoliation syndrome (OR, 1.79; P = .01), decreased central corneal thickness (OR, 1.38 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.31; P < .01), presence of beta-zone parapapillary atrophy (OR, 2.17; P < .01), and all IOP parameters (mean follow-up, peak, and fluctuation; P < .01) were associated with increased risk of VF progression. In the multivariable model, peak IOP (OR, 1.13; P < .01), thinner central corneal thickness (OR, 1.45 per 40 mu m thinner; P < .01), a detected disc hemorrhage (OR, 2.59; P < .01), and presence of beta-zone parapapillary atrophy (OR, 2.38; P < .01) were associated with VF progression. Conclusions: IOP-dependent and IOP-independent risk factors affect disease progression in treated glaucoma. Peak IOP is a better predictor of progression than is IOP mean or fluctuation.
Resumo:
Objective To study increases in electromyographic (EMG) response from the right and left rectus femoris muscles of individuals with long-term cervical spinal cord injuries after EMG biofeedback treatment. Design Repeated measure trials compared EMG responses before and after biofeedback treatment in patients with spinal cord injuries. Main outcome measures The Neuroeducator was used to analyse and provide feedback of the EMG signal and to measure EMG response. Setting Department of Traumatic Orthopaedics, School of Medicine, University of Sao Paulo, Brazil. Participants Twenty subjects (three men and 17 women), between 21 and 49 years of age, with incomplete spinal cord injury at level C6 or higher (range C2 to C6). Of these subjects, 10 received their spinal cord injuries from motor vehicle accidents, one from a gunshot, five from diving, three from falls and one from spinal disc herniation. Results Significant differences were found in the EMG response of the right rectus femoris muscle between pre-initial (T1), post-initial (T2) and additional (T3) biofeedback treatment with the subjects in a sitting position [mean (standard deviation) T1: 26 mu V (29); T2: 67 mu V (50); T3: 77 mu V (62)]. The mean differences and 95% confidence intervals for these comparisons were as follows: T1 to T2, -40.7 (-53.1 to -29.4); T2 to T3, -9.6 (-26.1 to 2.3). Similar differences were found for the left leg in a sitting position and for both legs in the sit-to-stand condition. Conclusions The EMG responses obtained in this study showed that treatment involving EMG biofeedback significantly increased voluntary EMG responses from right and left rectus femoris muscles in individuals with spinal cord injuries. (C) 2010 Chartered Society of Physiotherapy. Published by Elsevier Ltd. All rights reserved.
Resumo:
PURPOSE. To evaluate the effect of disease severity on the diagnostic accuracy of the Cirrus Optical Coherence Tomograph (Cirrus HD-OCT; Carl Zeiss Meditec, Inc., Dublin, CA) for glaucoma detection. METHODS. One hundred thirty-five glaucomatous eyes of 99 patients and 79 normal eyes of 47 control subjects were recruited from the longitudinal Diagnostic Innovations in Glaucoma Study (DIGS). The severity of the disease was graded based on the visual field index (VFI) from standard automated perimetry. Imaging of the retinal nerve fiber layer (RNFL) was obtained using the optic disc cube protocol available on the Cirrus HD-OCT. Pooled receiver operating characteristic (ROC) curves were initially obtained for each parameter of the Cirrus HD-OCT. The effect of disease severity on diagnostic performance was evaluated by fitting an ROC regression model, with VFI used as a covariate, and calculating the area under the ROC curve (AUCs) for different levels of disease severity. RESULTS. The largest pooled AUCs were for average thickness (0.892), inferior quadrant thickness (0.881), and superior quadrant thickness (0.874). Disease severity had a significant influence on the detection of glaucoma. For the average RNFL thickness parameter, AUCs were 0.962, 0.932, 0.886, and 0.822 for VFIs of 70%, 80%, 90%, and 100%, respectively. CONCLUSIONS. Disease severity had a significant effect on the diagnostic performance of the Cirrus HD-OCT and thus should be considered when interpreting results from this device and when considering the potential applications of this instrument for diagnosing glaucoma in the various clinical settings. (Invest Ophthalmol Vis Sci. 2010;51:4104-4109) DOI:10.1167/iovs.094716