991 resultados para Imaging camera
Resumo:
An imaging microscope, comprising a Schwarzchild condenser and zone plate optical arrangement, has been established on the Vulcan Nd-glass laser system at the Rutherford Appleton Laboratory (RAL). Images of simple test structures have been taken in X-ray transmission using doublet X-ray laser radiation at 23.2 nm and 23.6 nm from collisionally pumped Ne-like germanium. Image resolution of about 0.15 mum has been measured.
Resumo:
An imaging microscope, comprising a Schwarzchild condenser and a zone-plate optical arrangement, has been established on the Vulcan Nd:glass laser system at the Rutherford Appleton Laboratory. Magnified images of simple test structures have been taken in x-ray transmission in a single subnanosecond laser shot by using doublet x-ray laser radiation at 23.2 and 23.6 nm from collisionally pumped Ne-like germanium. Image resolutions of approximately 0.15 mum have been measured. The results are a proof of principle and demonstrate that images of potentially suboptical resolution and of specimen regions that are destroyed on passage of the x-ray beam can be taken successfully using the Vulcan x-ray laser.
Resumo:
As the state of the art for high power laser systems increases from terawatt to petawatt level and beyond, a crucial parameter for routinely monitoring high intensity performance is laser spot size on a solid target during an intense interaction in the tight focus regime ( 10(19) Wcm(-2) is demonstrated experimentally and shown to provide the basis for an effective focus diagnostic. Importantly, this technique is also shown to allow in-situ diagnosis of focal spot quality achieved after reflection from a double plasma mirror setup for very intense high contrast interactions (> 10(20) Wcm(-2)) an important application for the field of high laser contrast interaction science.
Resumo:
We present images of the source of extreme ultraviolet (XUV) harmonic emission at a wavelength of 220 Angstrom from the interaction of a 20 TW, 1.053 mu m Nd:glass laser beam focused to intensities up to 4x10(18) W cm(-2) onto a solid target. From these measurements we determine an upper limit to the source size and brightness of the harmonic emission to show its efficacy as a novel source of short-pulse, coherent XUV radiation. We also demonstrate the empirical scaling of the harmonic generation efficiency with irradiance up to 10(19) W mu m(2) cm(-2), and extrapolate to estimate the possible source brightness at higher irradiances. These source brightnesses are compared to those available from an x-ray laser system. (C) 1997 American Institute of Physics.
Resumo:
The development of a plasma discharge at low voltage (200-600 V) in saline solution is characterized using fast and standard CCD camera imaging. Vapor formation, plasma formation, and vapor collapse and subsequent pressure wave propagation are observed. If, with increasing voltage, the total energy deposited is kept approximately constant, the sequence and nature of events are similar but develop faster and more reproducibly at the higher voltages. This is attributed to the slower temporal evolution of the vapor layer at lower voltages which means a greater sensitivity to hydrodynamic instabilities at the vapor-liquid interface.
Resumo:
This paper describes the main parameters - contrast, spatial resolution, and thermal sensitivity - which define the performance of any stand-off imaging system. The origin of the signature for both metal and dielectric objects hidden under clothing in the frequency range from 100 GHz to 500 GHz is discussed. At 100 GHz the signature is dominated by reflection whilst at 500 GHz it is dominated by emission. A 94-GHz-passive millimetre-wave imaging system has been designed and fabricated to image objects under clothing. This imager is based on a Schmidt camera folded using polarisation techniques.