952 resultados para INSPECTION ERRORS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using a sample of 68.3x10(6) K(L)->pi(0)pi(0)pi(0) decays collected in 1996-1999 by the KTeV (E832) experiment at Fermilab, we present a detailed study of the K(L)->pi(0)pi(0)pi(0) Dalitz plot density. We report the first observation of interference from K(L)->pi(+)pi(-)pi(0) decays in which pi(+)pi(-) rescatters to pi(0)pi(0) in a final-state interaction. This rescattering effect is described by the Cabibbo-Isidori model, and it depends on the difference in pion scattering lengths between the isospin I=0 and I=2 states, a(0)-a(2). Using the Cabibbo-Isidori model, and fixing (a(0)-a(2))m(pi)(+)=0.268 +/- 0.017 as measured by the CERN-NA48 collaboration, we present the first measurement of the K(L)->pi(0)pi(0)pi(0) quadratic slope parameter that accounts for the rescattering effect: h(000)=(+0.59 +/- 0.20(stat)+/- 0.48(syst)+/- 1.06(ext))x10(-3), where the uncertainties are from data statistics, KTeV systematic errors, and external systematic errors. Fitting for both h(000) and a(0)-a(2), we find h(000)=(-2.09 +/- 0.62(stat)+/- 0.72(syst)+/- 0.28(ext))x10(-3), and m(pi)(+)(a(0)-a(2))=0.215 +/- 0.014(stat)+/- 0.025(syst)+/- 0.006(ext); our value for a(0)-a(2) is consistent with that from NA48.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We propose a method for measuring hyper-Rayleigh scattering employing pulse trains produced by a Q-switched and mode-locked Nd:YAG laser. The use of the entire pulse train under the Q-switch envelope avoids the need of any device to scan the irradiance, as is usually done with nanosecond and femtosecond single-pulse lasers. To verify the feasibility of the technique, we performed measurements in different solutions of para-nitroaniline and compared the results with those obtained with nanosecond pulses. In both cases, the agreement with the hyperpolarizability values reported in the literature is about the same, but the measurements carried out with pulse trains are at least 20 times faster. Besides the advantage of acquisition speed, the use of pulse trains also allows the instantaneous inspection of slow luminescence contributions arising from multiphoton absorption. (C) 2008 Optical Society of America.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alternative splicing of gene transcripts greatly expands the functional capacity of the genome, and certain splice isoforms may indicate specific disease states such as cancer. Splice junction microarrays interrogate thousands of splice junctions, but data analysis is difficult and error prone because of the increased complexity compared to differential gene expression analysis. We present Rank Change Detection (RCD) as a method to identify differential splicing events based upon a straightforward probabilistic model comparing the over-or underrepresentation of two or more competing isoforms. RCD has advantages over commonly used methods because it is robust to false positive errors due to nonlinear trends in microarray measurements. Further, RCD does not depend on prior knowledge of splice isoforms, yet it takes advantage of the inherent structure of mutually exclusive junctions, and it is conceptually generalizable to other types of splicing arrays or RNA-Seq. RCD specifically identifies the biologically important cases when a splice junction becomes more or less prevalent compared to other mutually exclusive junctions. The example data is from different cell lines of glioblastoma tumors assayed with Agilent microarrays.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Inductively coupled plasma optical emission spectrometers (ICP DES) allow fast simultaneous measurements of several spectral lines for multiple elements. The combination of signal intensities of two or more emission lines for each element may bring such advantages as improvement of the precision, the minimization of systematic errors caused by spectral interferences and matrix effects. In this work, signal intensities for several spectral lines were combined for the determination of Al, Cd, Co, Cr, Mn, Pb, and Zn in water. Afterwards, parameters for evaluation of the calibration model were calculated to select the combination of emission lines leading to the best accuracy (lowest values of PRESS-Predicted error sum of squares and RMSEP-Root means square error of prediction). Limits of detection (LOD) obtained using multiple lines were 7.1, 0.5, 4.4, 0.042, 3.3, 28 and 6.7 mu g L(-1) (n = 10) for Al, Cd. Co, Cr, Mn, Pb and Zn, respectively, in the presence of concomitants. On the other hand, the LOD established for the most intense emission line were 16. 0.7, 8.4, 0.074. 23, 26 and 9.6 mu g L(-1) (n = 10) for these same elements in the presence of concomitants. The accuracy of the developed procedure was demonstrated using water certified reference material. The use of multiple lines improved the sensitivity making feasible the determination of these analytes according to the target values required for the current environmental legislation for water samples and it was also demonstrated that measurements in multiple lines can also be employed as a tool to verify the accuracy of an analytical procedure in ICP DES. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a framework to build medical training applications by using virtual reality and a tool that helps the class instantiation of this framework. The main purpose is to make easier the building of virtual reality applications in the medical training area, considering systems to simulate biopsy exams and make available deformation, collision detection, and stereoscopy functionalities. The instantiation of the classes allows quick implementation of the tools for such a purpose, thus reducing errors and offering low cost due to the use of open source tools. Using the instantiation tool, the process of building applications is fast and easy. Therefore, computer programmers can obtain an initial application and adapt it to their needs. This tool allows the user to include, delete, and edit parameters in the functionalities chosen as well as storing these parameters for future use. In order to verify the efficiency of the framework, some case studies are presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The project of Information Architecture is one of the initial stages of the project of a website, thus the detection and correction of errors in this stage are easier and time-saving than in the following stages. However, to minimize errors for the projects of information architecture, a methodology is necessary to organize the work of the professional and guarantee the final product quality. The profile of the professional who works with Information Architecture in Brazil has been analyzed (quantitative research by means of a questionnaire on-line) as well as the difficulties, techniques and methodologies found in his projects (qualitative research by means of interviews in depth with support of the approaches of the Sense-Making). One concludes that the methodologies of projects of information architecture need to develop the adoption of the approaches of Design Centered in the User and in the ways to evaluate its results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study the hypothesis that interceptive movements are controlled on the basis of expectancy of time to target arrival was tested. The study was conducted through assessment of temporal errors and kinematics of interceptive movements to a moving virtual target. Initial target velocity was kept unchanged in part of the trials, and in the others it was decreased 300 ms before the due time of target arrival at the interception position, increasing in 100 ms time to target arrival. Different probabilities of velocity decrease ranging from 25 to 100% were compared. The results revealed that while there were increasing errors between probabilities of 25 and 75% for unchanged target velocity, the opposite relationship was observed for target velocity decrease. Kinematic analysis indicated that movement timing adjustments to target velocity decrease were made online. These results support the conception that visuomotor integration in the interception of moving targets is mediated by an internal forward model whose weights can be flexibly adjusted according to expectancy of time to target arrival.