956 resultados para High Performance Concrete


Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper presents a novel high symmetry balun which significantly improves the performance of dipole-based dual-polarized antennas. The new balun structure provides enhanced differential capability leading to high performance in terms of port-to-port isolation and far-field cross polarization. An example antenna using this balun is proposed. The simulated results show 53.5% of fractional bandwidth within the band 1.71−2.96 GHz (VSWR<1.5) and port-to-port isolation >59 dB. The radiation characteristic shows around 9 dBi of gain and far-field cross polarization <−48 dBi over the entire bandwidth. The detailed balun functioning and full antenna measurements will be presented during the conference. Performance comparison with similar structures will be also provided.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Through the awareness-raising efforts of several high-profile current and former athletes, the issue of common mental disorders (CMD) in this population is gaining increasing attention from researchers and practitioners alike. Yet the prevalence is unclear and most likely, under-reported. Whilst the characteristics of the sporting environment may generate CMD within the athletic population, it also may exacerbate pre-existing conditions, and hence it is not surprising that sport psychology and sport science practitioners are anecdotally reporting increased incidences of athletes seeking support for CMDs. In a population where there are many barriers to reporting and seeking help for CMD, due in part to the culture of the high performance sporting environment, anecdotal reports suggest that those athletes asking for help are approaching personnel who they are most comfortable talking to. In some cases, this may be a sport scientist, the sport psychologist or sport psychology consultant. Among personnel in the sporting domain, there is a perception that the sport psychologist or sport psychology consultant is best placed to assist athletes seeking assistance for CMD. However, sport psychology as a profession is split by two competing philosophical perspectives; one of which suggests that sport psychologists should work exclusively with athletes on performance enhancement, and the other views the athlete more holistically and accepts that their welfare may directly impact on their performance. To add further complication, the development of the profession of sport psychology varies widely between countries, meaning that practice in this field is not always clearly defined. This article examines case studies that illustrate the blurred lines in applied sport psychology practice, highlighting challenges with the process of referral in the U.K. athletic population. The article concludes with suggestions for ensuring the field of applied sport psychology is continually evolving and reconfiguring to ensure that it continues to meet the demands of its clients.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The high performance computing community has traditionally focused uniquely on the reduction of execution time, though in the last years, the optimization of energy consumption has become a main issue. A reduction of energy usage without a degradation of performance requires the adoption of energy-efficient hardware platforms accompanied by the development of energy-aware algorithms and computational kernels. The solution of linear systems is a key operation for many scientific and engineering problems. Its relevance has motivated an important amount of work, and consequently, it is possible to find high performance solvers for a wide variety of hardware platforms. In this work, we aim to develop a high performance and energy-efficient linear system solver. In particular, we develop two solvers for a low-power CPU-GPU platform, the NVIDIA Jetson TK1. These solvers implement the Gauss-Huard algorithm yielding an efficient usage of the target hardware as well as an efficient memory access. The experimental evaluation shows that the novel proposal reports important savings in both time and energy-consumption when compared with the state-of-the-art solvers of the platform.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La retracción autógena en el hormigón es el cambio volumétrico una vez iniciado su proceso de fraguado. Se desarrolla a edades muy tempranas debido a la retracción química y a la autodesecación. Éstos causan microfisuras en hormigones de alta resistencia y permiten el ingreso de agentes nocivos como dióxido de carbono, cloruros y sulfatos que deterioran al hormigón. A pesar de haber estudios de la retracción autógena, existe incertidumbre sobre su influencia en la durabilidad del hormigón. Por ello, el motivo del presente estudio es cuantificar y analizar el efecto de la retracción autógena en el hormigón usando tres pruebas de transporte: difusión de oxígeno, permeabilidad de oxígeno y absorción de agua. Dos métodos, para tres diferentes aglutinantes, fueron usados para determinar la mezcla control que produce menor retracción: utilizando SRA y realizando el curado en un cuarto de niebla. Posteriormente, los resultados de las pruebas de transporte entre la mezcla de control seleccionada y mezclas altamente afectadas por retracción autógena fueron comparados para diferentes aglutinantes. Resultados revelaron que muestras con SRA presentan menores retracciones autógenas y se sugiere que estas muestras sean consideradas de control. Se demostró que la retracción autógena afecta significativamente los coeficientes de transporte los cuales en un punto de vista de servicio pueden reducir la vida útil de cualquier estructura realizada con hormigón de alta resistencia. Esta investigación además confirmó que la mayor deformación autógena ocurre durante las dos primeras semanas; por lo tanto, se debe tomar cuidado suficiente en el curado.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2016.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

 This research provides initial evidence that a novel measure of training load, the T2minute method, is accurate for quantifying training in high performance rowing. This work also explored athlete wellness and rowing performance, with findings suggesting that the wellness-performance relationship is complex and changes over time due to individual-specific factors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Considerable interest has been devoted to converting mechanical energy into electricity using polymer nanofibres. In particular, piezoelectric nanofibres produced by electrospinning have shown remarkable mechanical energy-to-electricity conversion ability. However, there is little data for the acoustic-to-electric conversion of electrospun nanofibres. Here we show that electrospun piezoelectric nanofibre webs have a strong acoustic-to-electric conversion ability. Using poly(vinylidene fluoride) as a model polymer and a sensor device that transfers sound directly to the nanofibre layer, we show that the sensor devices can detect low-frequency sound with a sensitivity as high as 266 mV Pa(-1). They can precisely distinguish sound waves in low to middle frequency region. These features make them especially suitable for noise detection. Our nanofibre device has more than five times higher sensitivity than a commercial piezoelectric poly(vinylidene fluoride) film device. Electrospun piezoelectric nanofibres may be useful for developing high-performance acoustic sensors.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Tailoring the nanostructures of electrode materials is an effective way to enhance their electrochemical performance for energy storage. Herein, an ice-templating "bricks-and-mortar" assembly approach is reported to make ribbon-like V2O5 nanoparticles and CNTs integrated into a two-dimensional (2D) porous sheet-like V2O5-CNT nanocomposite. The obtained sheet-like V2O5-CNT nanocomposite possesses unique structural characteristics, including a hierarchical porous structure, 2D morphology, large specific surface area and internal conducting networks, which lead to superior electrochemical performances in terms of long-term cyclability and significantly enhanced rate capability when used as a cathode material for LIBs. The sheet-like V2O5-CNT nanocomposite can charge/discharge at high rates of 5C, 10C and 20C, with discharge capacities of approximately 240 mA h g-1, 180 mA h g-1, and 160 mA h g-1, respectively. It also retains 71% of the initial discharge capacity after 300 cycles at a high rate of 5C, with only 0.097% capacity loss per cycle. The rate capability and cycling performance of the sheet-like V2O5-CNT nanocomposite are significantly better than those of commercial V2O5 and most of the reported V2O5 nanocomposite.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

High-performance reduced graphene oxide/nickel foam (rGO/NF) composite electrodes for high-performance supercapacitors were prepared by flame-induced reduction of dry graphene oxide (GO) coated on nickel foam. Flame reduction of GO is a facile, feasible and cost-effective reduction technique, which is conducted without the need of any reductant. Most importantly, the rGO obtained by flame reduction showed a typical disordered cross-linking network and randomly distributed pores, which provide accessible routes for fast transportation of ions. It was demonstrated that the rGO/NF electrode with embedded current collector (NF) exhibited better electrochemical performance than conventional rGO film counterparts, including a high gravimetric specific capacitance of 228.6 F g-1 at a current density of 1 A g-1, excellent rate capability (over 81% retention at 32 A g-1) and high cycling stability with only 5.3% capacitance decay over 10,000 cycles of cyclic voltammetry at a ultrahigh scan rate of 1000 mV s-1. This facile method for the fabrication of rGO/NF electrodes could envision enormous potential for high performance energy storage devices.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

We survey articles on hedge funds' performance persistence and fundamental factors from the mid-1990s to the present. For performance persistence, we present some pioneering studies that contradict previous findings that hedge funds' performance is a short term matter. We discuss recent innovative studies that examine the size, age, performance fees and other factors to give a 360° view of hedge funds' performance attribution. Small funds, younger funds and funds with high performance fees all outperform the opposite. Long lockup period funds tend to outperform short lockups and domiciled funds tend to outperform offshore funds. This is the first survey of recent innovative and challenging studies into hedge funds' performance attribution, and it should be particularly useful to investors trying to choose between hedge funds.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Na actualidade, face ao desenvolvimento de betões de alto desempenho caracterizados por apresentarem muito baixa razão água cimento (A/C), tornou-se pertinente o estudo da retracção autogénea, por motivos relacionados com a resistência, durabilidade e estética destes materiais. Nesta dissertação foi elaborado um estudo prático com o intuito de avaliar o impacto da adição de agregado na redução da retracção autogénea, em seis misturas cimentícias. Através de ensaios foram obtidos valores reais de retracção autogénea, sendo estes posteriormente comparados com os valores obtidos teoricamente com recurso ao modelo proposto por Hobbs na década de 70. Tendo em consideração os valores teóricos e sua comparação com os valores reais obtidos nos ensaios é proposta uma alteração ao modelo teórico, que tem em conta a maior resistência à compressão dos betões actuais. Esta modificação permitiu estimar com maior exactidão os valores de retracção autogénea nas diferentes misturas. /ABSTRACT: Nowadays the development of high performance concretes characterized by a low water-to­ cement ratio (W/C), it became relevant to study the autogenous shrinkage, for reasons relating to the strength, durability and aesthetics of these materials. ln this study the effect of adding aggregate in six cementitious mixtures was evaluated. The results obtained in the experimental test were compared with theoretical values from a model propose by Hobbs in the 70's for autogenous shrinkage. Given the theoretical values and its comparison with the actual values obtained in the tests an amendment is proposed to the theoretical model that takes into account the higher compressive strength of actual concrete. This modification allowed us to estimate accurately the values of autogenous shrinkage in the different mixtures.