989 resultados para Heart-assist devices
Resumo:
Audit report on the Heart of Iowa Regional Transit Agency, Des Moines, Iowa, for the year ended June 30, 2012
Resumo:
Audit report on the Heart of Iowa Regional Transit Agency, Des Moines, Iowa, for the year ended June 30, 2012
Resumo:
Audit report on the Heart of Iowa Regional Transit Agency, Des Moines, Iowa, for the year ended June 30, 2012
Resumo:
Medical implants, like cardiovascular devices, improve the quality of life for countless individuals but may become infected with bacteria like Staphylococcus aureus. Such infections take the form of a biofilm, a structured community of bacterial cells adherent to the surface of a solid substrate. Every biofilm begins with an attractive force or bond between bacterium and substratum. We used atomic force microscopy to probe experimentally forces between a fibronectin-coated surface (i.e., proxy for an implanted cardiac device) and fibronectin-binding receptors on the surface of individual living bacteria from each of 80 clinical isolates of S. aureus. These isolates originated from humans with infected cardiac devices (CDI; n = 26), uninfected cardiac devices (n = 20), and the anterior nares of asymptomatic subjects (n = 34). CDI isolates exhibited a distinct binding-force signature and had specific single amino acid polymorphisms in fibronectin-binding protein A corresponding to E652D, H782Q, and K786N. In silico molecular dynamics simulations demonstrate that residues D652, Q782, and N786 in fibronectin-binding protein A form extra hydrogen bonds with fibronectin, complementing the higher binding force and energy measured by atomic force microscopy for the CDI isolates. This study is significant, because it links pathogenic bacteria biofilms from the length scale of bonds acting across a nanometer-scale space to the clinical presentation of disease at the human dimension.
Resumo:
Heart to Heart is a publication on new heart disease and stroke information and other related topics by the Department of Public Health.
Resumo:
Heart to Heart is a publication on new heart disease and stroke information and other related topics by the Department of Public Health.
Resumo:
Heart to Heart is a publication on new heart disease and stroke information and other related topics by the Department of Public Health.
Resumo:
PURPOSE: This longitudinal study aimed at comparing heart rate variability (HRV) in elite athletes identified either in 'fatigue' or in 'no-fatigue' state in 'real life' conditions. METHODS: 57 elite Nordic-skiers were surveyed over 4 years. R-R intervals were recorded supine (SU) and standing (ST). A fatigue state was quoted with a validated questionnaire. A multilevel linear regression model was used to analyze relationships between heart rate (HR) and HRV descriptors [total spectral power (TP), power in low (LF) and high frequency (HF) ranges expressed in ms(2) and normalized units (nu)] and the status without and with fatigue. The variables not distributed normally were transformed by taking their common logarithm (log10). RESULTS: 172 trials were identified as in a 'fatigue' and 891 as in 'no-fatigue' state. All supine HR and HRV parameters (Beta+/-SE) were significantly different (P<0.0001) between 'fatigue' and 'no-fatigue': HRSU (+6.27+/-0.61 bpm), logTPSU (-0.36+/-0.04), logLFSU (-0.27+/-0.04), logHFSU (-0.46+/-0.05), logLF/HFSU (+0.19+/-0.03), HFSU(nu) (-9.55+/-1.33). Differences were also significant (P<0.0001) in standing: HRST (+8.83+/-0.89), logTPST (-0.28+/-0.03), logLFST (-0.29+/-0.03), logHFST (-0.32+/-0.04). Also, intra-individual variance of HRV parameters was larger (P<0.05) in the 'fatigue' state (logTPSU: 0.26 vs. 0.07, logLFSU: 0.28 vs. 0.11, logHFSU: 0.32 vs. 0.08, logTPST: 0.13 vs. 0.07, logLFST: 0.16 vs. 0.07, logHFST: 0.25 vs. 0.14). CONCLUSION: HRV was significantly lower in 'fatigue' vs. 'no-fatigue' but accompanied with larger intra-individual variance of HRV parameters in 'fatigue'. The broader intra-individual variance of HRV parameters might encompass different changes from no-fatigue state, possibly reflecting different fatigue-induced alterations of HRV pattern.
Resumo:
Nitric oxide synthase (NOS) is strongly and transiently expressed in the developing heart but its function is not well documented. This work examined the role, either protective or detrimental, that endogenous and exogenous NO could play in the functioning of the embryonic heart submitted to hypoxia and reoxygenation. Spontaneously beating hearts isolated from 4-day-old chick embryos were either homogenized to determine basal inducible NOS (iNOS) expression and activity or submitted to 30 min anoxia followed by 100 min reoxygenation. The chrono-, dromo- and inotropic responses to anoxia/reoxygenation were determined in the presence of NOS substrate (L-arginine 10 mM), NOS inhibitor L-NIO (1-5 mM), or NO donor (DETA NONOate 10-100 microM). Myocardial iNOS was detectable by immunoblotting and its activity was specifically decreased by 53% in the presence of 5 mM L-NIO. L-Arginine, L-NIO and DETA NONOate at 10 microM had no significant effect on the investigated functional parameters during anoxia/reoxygenation. However, irrespective of anoxia/reoxygenation, DETA NONOate at 100 microM decreased ventricular shortening velocity by about 70%, and reduced atrio-ventricular propagation by 23%. None of the used drugs affected atrial activity and hearts of all experimental groups fully recovered at the end of reoxygenation. These findings indicate that (1) by contrast with adult heart, endogenously released NO plays a minor role in the early response of the embryonic heart to reoxygenation, (2) exogenous NO has to be provided at high concentration to delay postanoxic functional recovery, and (3) sinoatrial pacemaker cells are the less responsive to NO.
Resumo:
Although the physiological and pharmacological evidences suggest a role for angiotensin II (Ang II) with the mammalian heart, the source and precise location of Ang II are unknown. To visualize and quantitate Ang II in atria, ventricular walls and interventricular septum of the rat and human heart and to explore the feasibility of local Ang II production and function, we investigated by different methods the expression of proteins involved in the generation and function of Ang II. We found mRNA of angiotensinogen (Ang-N), of angiotensin converting enzyme, of the angiotensin type receptors AT(1A) and AT(2) (AT(1B) not detected) as well as of cathepsin D in any part of the hearts. No renin mRNA was traceable. Ang-N mRNA was visualized by in situ hybridization in atrial ganglial neurons. Ang II and dopamine-β-hydroxylase (DβH) were either colocalized inside the same neuronal cell or the neurons were specialized for Ang II or DβH. Within these neurons, the vesicular acetylcholine transporter (VAChT) was neither colocalized with Ang II nor DβH, but VAChT-staining was found with synapses en passant encircle these neuronal cells. The fibers containing Ang II exhibited with blood vessels and with cardiomyocytes supposedly angiotensinergic synapses en passant. In rat heart, right atrial median Ang II concentration appeared higher than septal and ventricular Ang II. The distinct colocalization of neuronal Ang II with DβH in the heart may indicate that Ang II participates together with norepinephrine in the regulation of cardiac functions: Produced as a cardiac neurotransmitter Ang II may have inotropic, chronotropic or dromotropic effects in atria and ventricles and contributes to blood pressure regulation.
Resumo:
L'hôpital de jour de psychiatrie de l'âge avancé du centre hospitalier universitaire Vaudois (CHUV), en Suisse, prend en charge ambulatoirement les personnes âgées souffrant de troubles psychiatriques. Cet article relate la première expérience de notre équipe d'une patiente qui est décédée à domicile via l'assistance au suicide alors qu'elle était suivie dans notre service pour un épisode dépressif sévère, de probables troubles cognitifs et un trouble de la personnalité émotionnellement labile de type borderline. Cette pratique d'assistance au suicide, autorisée par la loi suisse sous certaines conditions, est reprécisée et quelques directives médicoéthiques professionnelles sont présentées, avec un accent sur la capacité de discernement. © 2010 Elsevier Masson SAS. Tous droits réservés. The old age psychiatric daycare hospital of the Vaud University Hospital (CHUV), in Switzerland, follows up on elderly ambulatory patients with psychiatric disease. This article relates our team's first time experience with a patient who, while she was being treated in our unit for severe depression, cognitive symptoms and a borderline personality disorder, died at home via a suicide organization. Assisted suicide, allowed by the Swiss law, is also discussed in this article and, in addition, a few professional medico-ethics directives, with an emphasis on decision-making capacity are presented. © 2010 Elsevier Masson SAS. All rights reserved.
Resumo:
Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.