967 resultados para Floor Plate


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: This is the first report of involvement of Australian and New Zealand oral and maxillofacial surgeons in the management of isolated orbital floor blow-out fractures and was conducted to obtain comparisons with the results from a recent similar survey of British oral and maxillofacial surgeons. Methods: A questionnaire survey was sent to all 113 practising members of the Australian and New Zealand Association of Oral and Maxillofacial Surgeons in April 2002 with a second mailout 1 month later. Results: Sixty-nine per cent of the respondents were referred isolated orbital floor blow-out fractures for manage-ment, and just over half of these respondents estimated that 50% or more of the cases went to surgery. The materials most commonly used in orbital floor reconstruction were resorbable membrane for small defects and autologous bone for large defects. Conclusion: As in Britain, management of isolated orbital floor blow-out fractures comprises part of the surgical spectrum for many oral and maxillofacial surgeons in Australia and New Zealand. The management protocol was observed to be very similar between the two groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pelvic floor muscles (PFM) are part of the trunk stability mechanism. Their function is interdependent with other muscles of this system. They also contribute to continence, elimination, sexual arousal and intra-abdominal pressure. This paper outlines some aspects of function and dysfunction of the PFM complex and describes the contribution of other trunk muscles to these processes. Muscle pathophysiology of stress urinary incontinence (SUI) is described in detail. The innovative rehabilitation programme for SUI presented here utilizes abdominal muscle action to initiate tonic PFM activity. Abdominal muscle activity is then used in PFM strengthening, motor relearning for functional expiratory actions and finally impact training. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thin, piezoelectric circular plates are frequently used as active components in transducer and smart materials applications. This paper reports on the exact, explicit solution for the transient motion of a piezoelectric circular plate, built-in or simply supported on the edge and electrically grounded over the entire surface. Expressed by elementary Bessel functions and obtained via exact inverse Laplace transforms, the solution enables the efficient calculation of accurate system parameters. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abnormalities in the growth plate may lead to short stature and skeletal deformity including Leri Weil syndrome, which has been shown to result from deletions or mutations in the SHOX gene, a homeobox gene located at the pseudoautosomal region of the X and Y chromosome. We studied the expression of SHOX protein, by immunohistochemistry, in human fetal and childhood growth plates and mRNA by in situ hybridization in childhood normal and Leri Weil growth plate. SHOX protein was found in reserve, proliferative, and hypertrophic zones of fetal growth plate from 12 wk to term and childhood control and Leri Weil growth plates. The pattern of immunostaining in the proliferative zone of childhood growth plate was patchy, with more intense uniform immunostaining in the hypertrophic zone. In situ hybridization studies of childhood growth plate demonstrated SHOX mRNA expression throughout the growth plate. No difference in the pattern of SHOX protein or mRNA expression was seen between the control and Leri Weil growth plate. These findings suggest that SHOX plays a role in chondrocyte function in the growth plate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel and precise assay that facilitates high-throughput screening of fibrinolytic agents was developed based on the automated assessment of the euglobulin clot lysis time in microtitre plates. Euglobulin fractions from fresh plasma samples were assessed over 28 days to determine the inter-assay and intra-assay precision. The intra-assay (coefficient of variation range, 0.7-2.6%) and inter-assay precision (coefficient of variation range, 6.8-12.1%) was found to be well within limits required by the Food and Drug Administration. On day 1 and day 28, the results of the microtitre plate euglobulin clot lysis time method were compared with tissue plasminogen activator activity, plasminogen activator inhibitor activity and results produced on fibrin plates. All comparisons were found to correlate significantly. The validity of this method for assaying fibrinolytic agents was assessed by comparing dose-response curves for streptokinase produced using fibrin plates and this method. The critical influence of ambient temperature on the inter-assay reproducibility of this method was established by testing samples over a range of temperatures between 20degreesC and 40degreesC. (C) 2004 Lippincott Williams Wilkins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Earthquakes have been recognized as resulting from stick-slip frictional instabilities along the faults between deformable rocks. A three-dimensional finite-element code for modeling the nonlinear frictional contact behaviors between deformable bodies with the node-to-point contact element strategy has been developed and applied here to investigate the fault geometry influence on the nucleation and development process of the stick-slip instability along an intra-plate fault through a typical fault bend model, which has a pre-cut fault that is artificially bent by an angle of 5.6degrees at the fault center. The numerical results demonstrate that the geometry of the fault significantly affects nucleation, termination and restart of the stick-slip instability along the intra-plate fault, and all these instability phenomena can be well simulated using the current finite-element algorithm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent discoveries of different modes of exocytosis and a plethora of molecules involved in neurotransmitter release has resulted in demand for more rapid and efficient methods for monitoring endogenous glutamate release from various tissue sources. In this article, we describe a high throughput microplate version of the enzyme-linked fluorescence detection method for the measurement of released glutamate, which utilises glutamate dehydrogenase, and the reduction of NADP to NADPH. Previous versions of this method rely upon cuvette-based fluorimeters for detection that are limited by large sample volumes and small numbers of samples that can be measured simultaneously. Comparison between the two methods shows that the microplate assay has comparable performance to the cuvette-based assay but has the capacity to analyse many times more samples in a given run. This increased capacity provides improved experimental design opportunities, higher experimental throughput and better comparison between experimental conditions. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Question Do different sitting postures require different levels of pelvic floor and abdominal muscle activity in healthy women? Design Observational study. Participants Eight parous women with no pelvic floor dysfunction. Outcome measures Bilateral activity of pelvic floor muscles (assessed vaginally) and two abdominal muscles, obliquus internus abdominis and obliquus externus abdominis, during three sitting postures. Results There was a significant increase in pelvic floor muscle activity from slump supported sitting (mean 7.2% maximal voluntary contraction, SD 4.8) to both upright unsupported sifting (mean 12.6% maximal voluntary contraction, SD 7.8) (p = 0.01) and very tall unsupported sitting (mean 24.3% maximal voluntary contraction, SD 14.2) (p = 0.004). Activity in both abdominal muscles also increased but did not reach statistical significance. Conclusion Both unsupported sitting postures require greater pelvic floor muscle activity than the supported sitting posture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to determine whether postural activity of the pelvic floor (PF) and abdominal muscles differs between continent and incontinent women during rapid arm movements that present a postural challenge to the trunk. A further aim was to study the effect of bladder filling. Electromyographic activity (EMG) of the PF, abdominal, erector spinae (ES), and deltoid muscles was recorded with surface electrodes. During rapid shoulder flexion and extension, PF EMG increased before that of the deltoid in continent women, but after the deltoid in incontinent women (p= 0.002). In many incontinent women, PF EMG decreased before the postural activation. Although delayed, postural PF EMG amplitude was greater in women with incontinence ( p= 0.010). In both groups, PF EMG decreased and abdominal and ES EMG increased when the bladder was moderately full. These findings would be expected to have negative consequences for continence and lumbopelvic stability in women with incontinence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Understanding and explaining emergent constitutive laws in the multi-scale evolution from point defects, dislocations and two-dimensional defects to plate tectonic scales is an arduous challenge in condensed matter physics. The Earth appears to be the only planet known to have developed stable plate tectonics as a means to get rid of its heat. The emergence of plate tectonics out of mantle convection appears to rely intrinsically on the capacity to form extremely weak faults in the top 100 km of the planet. These faults have a memory of at least several hundred millions of years, yet they appear to rely on the effects of water on line defects. This important phenomenon was first discovered in laboratory and dubbed ``hydrolytic weakening''. At the large scale it explains cycles of co-located resurgence of plate generation and consumption (the Wilson cycle), but the exact physics underlying the process itself and the enormous spanning of scales still remains unclear. We present an attempt to use the multi-scale non-equilibrium thermodynamic energy evolution inside the deforming lithosphere to move phenomenological laws to laws derived from basic scaling quantities, develop self-consistent weakening laws at lithospheric scale and give a fully coupled deformation-weakening constitutive framework. At meso- to plate scale we encounter in a stepwise manner three basic domains governed by the diffusion/reaction time scales of grain growth, thermal diffusion and finally water mobility through point defects in the crystalline lattice. The latter process governs the planetary scale and controls the stability of its heat transfer mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on Reddy's third-order theory, the first-order theory and the classical theory, exact explicit eigenvalues are found for compression buckling, thermal buckling and vibration of laminated plates via analogy with membrane vibration, These results apply to symmetrically laminated composite plates with transversely isotropic laminae and simply supported polygonal edges, Comprehensive consideration of a Winkler-Pasternak elastic foundation, a hydrostatic inplane force, an initial temperature increment and rotary inertias is incorporated. Bridged by the vibrating membrane, exact correspondences are readily established between any pairs of buckling and vibration eigenvalues associated with different theories. Positive definiteness of the critical hydrostatic pressure at buckling, the thermobukling temperature increment and, in the range of either tension loading or compression loading prior to occurrence of buckling, the natural vibration frequency is proved. (C) 2000 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The flat plate system is currently widely used in construction. It permits architectural flexibility, more clear space, less building height, easier formwork, and shorter construction time. However, there remains the problem of brittle punching failure due to the transfer of shearing forces and unbalanced moments at the flat plate-column connection. It is the purpose of this paper to investigate the effects of various interdependent factors that govern the punching shear resistance and behaviour of the flat plate-column connection, as well as their inclusion in current Codes.