965 resultados para FIXED DENTAL PROSTHESES
Resumo:
Purpose: This study evaluated possible publication bias and its related factors in implant-related research over time. Materials and Methods: Articles published in Clinical Implant Dentistry and Related Research, Clinical Oral Implants Research, Implant Dentistry, Journal of Oral Implantology, and The International Journal of Oral & Maxillofacial Implants between 2005 and 2009 were reviewed. Nonoriginal articles were excluded. For each article included, study outcome, extramural funding source, type of study, and geographic origin were recorded. Descriptive and analytic statistics (alpha = .05), including the chi-square test and logistic regression analysis, were performed where appropriate. Results: From a total of 2,085 articles, 1,503 met the inclusion criteria. of the articles analyzed, 1,226 (81.6%), 160 (10.6%), and 117 (7.8%) articles reported positive, negative, and neutral outcomes, respectively. In vitro studies, studies from Asia, and funded animal studies were more likely to report positive outcomes compared to others (P = .02, P < .0001, and P = .009, respectively). Industry-funded studies represented the lowest frequency of positive outcomes versus studies funded by other sources. Conclusions: There were a high number of implant-related studies reporting positive outcomes in the five selected journals. Some selected factors were associated with positive outcome bias. In general, funding was not associated with a positive outcome, except for animal studies. Industry-supported research did not show any association with the publication of positive outcomes. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:1024-1032
Resumo:
The objectives of this study were, through a literature review, to point the differences between orbital implants and their advantages and disadvantages, to evaluate prosthesis motility after orbital implants are inserted, and to point the implant wrapping current risks. Sixty-seven articles were reviewed. Enucleation implants can be autoplastics or alloplastics and porous (including natural and synthetic hydroxyapatite [HA]) or nonporous (silicone). Hydroxyapatite is the most related in the literature, but it has disadvantages, too, that is, all orbital implants must be wrapped. Exposure of the porous orbital implant can be repaired using different materials, which include homologous tissue, as well as autogenous graft, xenograft, and synthetic material mesh. The most used materials are HA and porous polyethylene orbital implant. The HA implant is expensive and possibly subject corals to damage, different from porous polyethylene orbital implants. Porous implants show the best prosthesis motility and a minimum rate of implants extrusion. Implant wraps can facilitate smoother entry of the implant into the orbit and allow reattachment of extraocular muscles. They also serve as a barrier between the overlying soft tissue and the rough surface of the implant, protecting implants from exposure or erosion.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: The aim of this study was to compare 2 different methods of assessment of implants at different inclinations (90 degrees and 65 degrees)-with a profilometer and AutoCAD software. Materials and Methods: Impressions (n = 5) of a metal matrix containing 2 implants, 1 at 90 degrees to the surface and 1 at 65 degrees to the surface, were obtained with square impression copings joined together with dental floss splinting covered with autopolymerizing acrylic resin, an open custom tray, and vinyl polysiloxane impression material. Measurement of the angles (in degrees) of the implant analogs were assessed by the same blinded operator with a profilometer and through analysis of digitized images by AutoCAD software. For each implant analog, 3 readings were performed with each method. The results were subjected to a nonparametric Kruskal-Wallis test, with P <= .05 considered significant. Results: For implants perpendicular to the horizontal surface of the specimen (90 degrees), there were no significant differences between the mean measurements obtained with the profilometer (90.04 degrees) and AutoCAD (89.95 degrees; P=.9142). In the analyses of the angled implants at 65 degrees in relation to the horizontal surface of the specimen, significant differences were observed (P=.0472) between the mean readings with the profilometer (65.73 degrees) and AutoCAD (66.25 degrees). Conclusions: The degrees of accuracy of implant angulation recording vary among the techniques available and may vary depending on the angle of the implant. Further investigation is needed to determine the best test conditions and the best measuring technique for determination of the angle of the implant in vitro.
Resumo:
Background: The absence of an ear, which can be the result of a congenital malformation, surgical tumour resection or traumatic injury, is a significant aesthetic problem. Attachment of ear prostheses with adhesives can cause local irritation for the wearer and affect the colour of the prostheses. Use of implants in craniofacial reconstruction can improve the retention and stability of prostheses giving to patient greater comfort and security relative to adhesive attachment.Objective: The aim of this report was to present a clinical case of a mutilated patient who was rehabilitated by means of installing an ear prosthesis fixed through osseointegrated implants.Materials and methods: The patient had two implants installed in the mastoid region that were linked by a bar, and a clip-type system was used. The ear prosthesis was constructed from medical-use silicone, pigmented to match the patient's skin colour and linked to the retention system.Conclusion: The patient's rehabilitation was satisfactory from both a functional and an aesthetic point of view, making it possible for the patient to return to a normal social life and regain lost self-esteem.
Resumo:
The failure of facial prostheses is caused by limitations in the properties of existing materials, especially the biocompatibility. This study aimed to evaluate the biocompatibility of maxillofacial silicones in subcutaneous tissue of rats. Thirty Wistar rats received subcutaneous implants of 3 maxillofacial silicone elastomers (LIM 6050, MDX 4-4210, and industrial Silastic 732 RTV). A histomorphometric evaluation was conducted to analyze the biocompatibility of the implants. Eight areas of 60.11 mm(2) from the surgical pieces were analyzed. Mesenchymal cells, eosinophils, and foreign-body giant cells were counted. Data were submitted to analysis of variance and Tukey test. Initially, all implanted materials exhibited an acceptable tissue inflammatory response, with tissue reactions varying from light to moderate. Afterward, a fibrous capsule around the silicone was observed. The silicones used in the current study presented biocompatibility and can be used for implantation in both medical and dental areas. Their prosthetic indication is conditioned to their physical properties. Solid silicone is easier to adapt and does not suffer apparent modifications inside the tissues.
Resumo:
Different transfer impression techniques for implant-supported prostheses have been suggested to obtain a working cast. This article describes and illustrates clinical and laboratory pros-thodontic procedures to transfer implant positions with splinted transfer copings and without impression material to form a laboratory analog transfer template. With this technique, a preliminary cast is modified to place the analogs according to a corrected position and obtain the master cast. Although this technique does not record adjacent tissues, it is a simple procedure, less time consuming, and easily performed.
Resumo:
Objective: The purpose of the present study was to evaluate the influence of radiation in osseointegrated dental implants installed in tibiae of rats.Material and methods: Screw-shaped implants (2.5 mm diameter by 3.5 mm length) were custom made from commercially pure titanium bars. Titanium implants were blasted and sterilized before implantation. Animals were divided into two groups of 12 animals each and the rats were not paired after the groups' formation. The experimental group (group 1) received external irradiation 4 weeks after surgery while in the control group (group 2) animals were kept free of radiation. The shear strength required to detach the implant from bone was measured by push-out testing and osseointegration was histologically evaluated.Results: Results showed that the compressive strength of irradiated implants (33.49 MPa) was significantly lower than the compressive strength of non-irradiated implants (48.05 MPa).Conclusions: We concluded that the mechanical strength bonding between implants and host tissues decreased after irradiation.
Resumo:
Osseointegrated implants in craniofacial reconstructions improve prostheses retention and stability and comfort and safety for a patient. According to biomechanical principles, the treatment success regarding osseointegration maintenance depends on an adequate surgical technique associated to a retention system that provides favorable tension distribution to implants. Furthermore, patient expectation, esthetics, function, and anatomic limitations must be evaluated during treatment planning. Therefore, the aims of this study were to present available retention systems to implant-supported craniofacial prosthesis and to highlight the advantages, indications, and limitations. A literature review was conducted through a MEDLINE search. Sixteen articles and 2 textbooks met the inclusion criteria and were included in the review. It was concluded that the success of craniofacial rehabilitation with implants depends on an adequate surgical technique and an adequate selection of a retention system.
Resumo:
Background: Considering that an increasing number of patients are victims of mutilator surgical resections, these studies are important for treatment success of rehabilitation of patients presenting oronasal communication.Purpose: The aim of this study was to assess the stress distribution through photoelasticity in palatal obturator prostheses with different attachment systems for implants.Methods: Two photoelastic models were obtained from an experimental maxillary model presenting an oronasal communication. One model was fabricated without implant, and the other with 2 implants 10 mm in length inserted in the left crest. Four colorless palatal obturator prostheses were fabricated. One prosthesis presented no attachment system, whereas the remaining prostheses were adapted to 3 attachment systems. The assembly was positioned in a circular polariscope for application of axial load.Results: The results were based on photographic records of stress in the photoelastic model submitted to loading. The records revealed higher stress concentration on the bar-clip system followed by the O'ring/bar-clip and O'ring systems, respectively. A homogeneous stress distribution was observed on the photoelastic model with the mucous-supported prosthesis.Conclusions: The attachment systems generated different characteristics of stress distribution that was concentrated surrounding the implants. The bar-clip system exhibited the highest stress concentration on the alveolar crest.
Resumo:
Objectives: The aim of this study was to evaluate the frequency of removable partial dentures (RPD) at the Aracatuba Dental School.Methods: The study was conducted by analysing 412 clinical history of patients attended at the RPD clinics in the period from 2000 to 2007.Results: 412 charts were analysed: 148 (35.9%) men and 264 (64.1%) women. The mean age was 53.8 years (men) and 52.4 years (women). A total of 556 dentures were made; of these, 233 (41.90%) were maxillary and 323 (58.09%) were mandibular dentures. The most frequent Kennedy classification found was Class III (maxilla) and Class I (mandible). In the maxilla, 55% (126) of the major connectors were of the anterior-posterior palatal bar, while in the mandible, 64% (202) were the lingual bar. As regards the claps, 401 were circumferential and 318 were bar claps.Conclusion: The mean age of the patients was 52.9 years with higher prevalence of female patients; the most frequent Kennedy's classification was Class I in mandible and Class III in maxilla; the most common major connector was anterior-posterior palatal bar for maxilla and lingual bar for mandible; the circumferential clasps were the most common retainer used in both jaws.
Resumo:
International Journal of Paediatric Dentistry 2012; 22: 310316 Background. Generalized aggressive periodontitis (GAP) in primary teeth is a rare periodontal disease that occurs during or soon after eruption of the primary teeth. An association with systemic diseases is a possibility. Case Report. A 4-year-old Brazilian girl presented with GAP involving the entire primary dentition. The patient and her parents and sister were subjected to microbiological testing to identify the microorganisms involved in the disease. The patient underwent tooth extraction to eradicate the disease and received a prosthesis for the restoration of masticatory function. After the permanent teeth erupted, fixed orthodontic appliances were place to restore dental arch form and occlusion. Conclusions. The results show the importance of an early diagnosis of GAP and of a multidisciplinary approach involving laboratory and clinical management to treat the disease and to restore masticatory function, providing a better quality of life for patients.
Resumo:
Cancer is regarded as the abnormal cellular multiplication; it is not controlled by the organism; and its cells present a differentiated DNA. Initially, the disease does not show clinical signs, but it can be diagnosed by laboratorial examinations. When tumors are present in the maxillofacial area, they can entail the loss of these area organs, which become responsible for the carrier's social environment exclusion. This paper aimed at showing, through a literature review, the cancers that more commonly happen in the face and the possibilities of regenerating in the patient mutilated through surgical reconstruction and prostheses.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)