981 resultados para ENDOSSEOUS IMPLANTS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Glass is a unique material with a long history. Several glass products are used daily in our everyday life, often unnoticed. Glass can be found not only in obvious applications such as tableware, windows, and light bulbs, but also in tennis rackets, windmill turbine blades, optical devices, and medical implants. The glasses used at present as implants are inorganic silica-based melt-derived compositions mainly for hard-tissue repair as bone graft substitute in dentistry and orthopedics. The degree of glass reactivity desired varies according to implantation situation and it is vital that the ion release from any glasses used in medical applications is controlled. Understanding the in vitro dissolution rate of glasses provides a first approximation of their behavior in vivo. Specific studies concerning dissolution properties of bioactive glasses have been relatively scarce and mostly concentrated to static condition studies. The motivation behind this work was to develop a simple and accurate method for quantifying the in vitro dissolution rate of highly different types of glass compositions with interest for future clinical applications. By combining information from various experimental conditions, a better knowledge of glass dissolution and the suitability of different glasses for different medical applications can be obtained. Thus, two traditional and one novel approach were utilized in this thesis to study glass dissolution. The chemical durability of silicate glasses was tested in water and TRIS-buffered solution at static and dynamic conditions. The traditional in vitro testing with a TRISbuffered solution under static conditions works well with bioactive or with readily dissolving glasses, and it is easy to follow the ion dissolution reactions. However, in the buffered solution no marked differences between the more durable glasses were observed. The hydrolytic resistance of the glasses was studied using the standard procedure ISO 719. The relative scale given by the standard failed to provide any relevant information when bioactive glasses were studied. However, the clear differences in the hydrolytic resistance values imply that the method could be used as a rapid test to get an overall idea of the biodegradability of glasses. The standard method combined with the ion concentration and pH measurements gives a better estimate of the hydrolytic resistance because of the high silicon amount released from a glass. A sensitive on-line analysis method utilizing inductively coupled plasma optical emission spectrometer and a flow-through micro-volume pH electrode was developed to study the initial dissolution of biocompatible glasses. This approach was found suitable for compositions within a large range of chemical durability. With this approach, the initial dissolution of all ions could be measured simultaneously and quantitatively, which gave a good overall idea of the initial dissolution rates for the individual ions and the dissolution mechanism. These types of results with glass dissolution were presented for the first time during the course of writing this thesis. Based on the initial dissolution patterns obtained with the novel approach using TRIS, the experimental glasses could be divided into four distinct categories. The initial dissolution patterns of glasses correlated well with the anticipated bioactivity. Moreover, the normalized surface-specific mass loss rates and the different in vivo models and the actual in vivo data correlated well. The results suggest that this type of approach can be used for prescreening the suitability of novel glass compositions for future clinical applications. Furthermore, the results shed light on the possible bioactivity of glasses. An additional goal in this thesis was to gain insight into the phase changes occurring during various heat treatments of glasses with three selected compositions. Engineering-type T-T-T curves for glasses 1-98 and 13-93 were stablished. The information gained is essential in manufacturing amorphous porous implants or for drawing of continuous fibers of the glasses. Although both glasses can be hot worked to amorphous products at carefully controlled conditions, 1-98 showed one magnitude greater nucleation and crystal growth rate than 13-93. Thus, 13-93 is better suited than 1-98 for working processes which require long residence times at high temperatures. It was also shown that amorphous and partially crystalline porous implants can be sintered from bioactive glass S53P4. Surface crystallization of S53P4, forming Na2O∙CaO∙2SiO2, was observed to start at 650°C. The secondary crystals of Na2Ca4(PO4)2SiO4, reported for the first time in this thesis, were detected at higher temperatures, from 850°C to 1000°C. The crystal phases formed affected the dissolution behavior of the implants in simulated body fluid. This study opens up new possibilities for using S53P4 to manufacture various structures, while tailoring their bioactivity by controlling the proportions of the different phases. The results obtained in this thesis give valuable additional information and tools to the state of the art for designing glasses with respect to future clinical applications. With the knowledge gained we can identify different dissolution patters and use this information to improve the tuning of glass compositions. In addition, the novel online analysis approach provides an excellent opportunity to further enhance our knowledge of glass behavior in simulated body conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large-headed total hip arthroplasty (THA) and hip resurfacing arthroplasty (HRA) with metal-on-metal (MoM) bearings became popular during the last decade. Recently, it has become evident that the large-head MoM hip implants are associated with increased revision rates despite their theoretical advantages. The purpose of this study was to evaluate the early results of primary MoM hip replacements and of acetabular revisions. I analyzed retrospectively the results of four MoM implant designs and the survival rate of acetabular revisions with impaction bone grafting, as documented in the Turku University Hospital database. Further, I evaluated the correlation between femoral head size and dislocation rate, and used the Finnish Arthroplasty Register data to compare the survival of three large-head MoM THAs to analogous HRAs. The early results for the Magnum M2A–ReCap THA were good. A larger head size decreased the risk of dislocation. Articular surface replacement (ASR) THA yielded inferior results compared to analogous HRA. For two other designs the results were similar. The R3–Synergy THA yielded inferior results compared to the reference implants. The survival of acetabular reconstructions with impaction bone grafting was inferior compared to previous reports. In conclusion, the early results of the Biomet ReCap–Magnum design were promising, and large head sizes decreased the dislocation rate. The survival of different MoM hip implant designs varied. The survival of new designs and techniques may be inferior to those reported by the clinics where implants are developed. An important caveat is that early promising results of new devices may rapidly worsen. New implants need to be introduced in a controlled fashion to the market; here, arthroplasty registers are a valuable tool that needs to be used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endochondral calcification involves the participation of matrix vesicles (MVs), but it remains unclear whether calcification ectopically induced by implants of demineralized bone matrix also proceeds via MVs. Ectopic bone formation was induced by implanting rat demineralized diaphyseal bone matrix into the dorsal subcutaneous tissue of Wistar rats and was examined histologically and biochemically. Budding of MVs from chondrocytes was observed to serve as nucleation sites for mineralization during induced ectopic osteogenesis, presenting a diameter with Gaussian distribution with a median of 306 ± 103 nm. While the role of tissue-nonspecific alkaline phosphatase (TNAP) during mineralization involves hydrolysis of inorganic pyrophosphate (PPi), it is unclear how the microenvironment of MV may affect the ability of TNAP to hydrolyze the variety of substrates present at sites of mineralization. We show that the implants contain high levels of TNAP capable of hydrolyzing p-nitrophenylphosphate (pNPP), ATP and PPi. The catalytic properties of glycosyl phosphatidylinositol-anchored, polidocanol-solubilized and phosphatidylinositol-specific phospholipase C-released TNAP were compared using pNPP, ATP and PPi as substrates. While the enzymatic efficiency (k cat/Km) remained comparable between polidocanol-solubilized and membrane-bound TNAP for all three substrates, the k cat/Km for the phosphatidylinositol-specific phospholipase C-solubilized enzyme increased approximately 108-, 56-, and 556-fold for pNPP, ATP and PPi, respectively, compared to the membrane-bound enzyme. Our data are consistent with the involvement of MVs during ectopic calcification and also suggest that the location of TNAP on the membrane of MVs may play a role in determining substrate selectivity in this micro-compartment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During the process of endochondral bone formation, chondrocytes and osteoblasts mineralize their extracellular matrix by promoting the formation of hydroxyapatite (HA) seed crystals in the sheltered interior of membrane-limited matrix vesicles (MVs). Ion transporters control the availability of phosphate and calcium needed for HA deposition. The lipidic microenvironment in which MV-associated enzymes and transporters function plays a crucial physiological role and must be taken into account when attempting to elucidate their interplay during the initiation of biomineralization. In this short mini-review, we discuss the potential use of proteoliposome systems as chondrocyte- and osteoblast-derived MVs biomimetics, as a means of reconstituting a phospholipid microenvironment in a manner that recapitulates the native functional MV microenvironment. Such a system can be used to elucidate the interplay of MV enzymes during catalysis of biomineralization substrates and in modulating in vitro calcification. As such, the enzymatic defects associated with disease-causing mutations in MV enzymes could be studied in an artificial vesicular environment that better mimics their in vivo biological milieu. These artificial systems could also be used for the screening of small molecule compounds able to modulate the activity of MV enzymes for potential therapeutic uses. Such a nanovesicular system could also prove useful for the repair/treatment of craniofacial and other skeletal defects and to facilitate the mineralization of titanium-based tooth implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endometriosis is a complex and multifactorial disease. Chromosomal imbalance screening in endometriotic tissue can be used to detect hot-spot regions in the search for a possible genetic marker for endometriosis. The objective of the present study was to detect chromosomal imbalances by comparative genomic hybridization (CGH) in ectopic tissue samples from ovarian endometriomas and eutopic tissue from the same patients. We evaluated 10 ovarian endometriotic tissues and 10 eutopic endometrial tissues by metaphase CGH. CGH was prepared with normal and test DNA enzymatically digested, ligated to adaptors and amplified by PCR. A second PCR was performed for DNA labeling. Equal amounts of both normal and test-labeled DNA were hybridized in human normal metaphases. The Isis FISH Imaging System V 5.0 software was used for chromosome analysis. In both eutopic and ectopic groups, 4/10 samples presented chromosomal alterations, mainly chromosomal gains. CGH identified 11q12.3-q13.1, 17p11.1-p12, 17q25.3-qter, and 19p as critical regions. Genomic imbalances in 11q, 17p, 17q, and 19p were detected in normal eutopic and/or ectopic endometrium from women with ovarian endometriosis. These regions contain genes such as POLR2G, MXRA7 and UBA52 involved in biological processes that may lead to the establishment and maintenance of endometriotic implants. This genomic imbalance may affect genes in which dysregulation impacts both eutopic and ectopic endometrium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present study was to compare healing obtained with biomembranes with the natural healing process (sham) using biochemical and immunohistological assays. C57BL/6 mice were divided into 4 groups of 15 mice each and received different subcutaneous implants: natural latex biomembrane (NLB), denatured latex (DL), expanded polytetrafluorethylene (ePTFE), or sham. On the 2nd, 7th, and 14th days post-treatment, 5 mice per group were sacrificed and biopsied for the following measurements: oxidative stress based on malondialdehyde (MDA), myeloperoxidase (MPO) and hydrogen peroxide by the method of ferrous oxidation-xylenol orange (FOX), as well as glutathione and total proteins; histological evaluation to enumerate inflammatory cells, fibroblasts, blood vessels, and collagen, and immunohistochemical staining for inducible nitric oxide synthase, interleukin-1β, vascular endothelial growth factor (VEGF), and transforming growth factor-β1 (TGF-β1). On day 2 post-treatment, NLB stimulated a dense inflammatory infiltrate mainly consisting of polymorphonuclear cells, as indicated by increased MPO (P < 0.05), but oxidative stress due to MDA was not observed until the 7th day (P < 0.05). The number of blood vessels was greater in NLB (P < 0.05) and DL (P < 0.05) mice compared to sham animals on day 14. NLB induced fibroplasia by day 14 (P < 0.05) with low expression of TGF-β1 and collagenesis. Thus, NLB significantly induced the inflammatory phase of healing mediated by oxidative stress, which appeared to influence the subsequent phases such as angiogenesis (with low expression of VEGF) and fibroplasia (independent of TGF-β1) without influencing collagenesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Heterotopic ossification (HO) is a metaplastic biological process in which there is newly formed bone in soft tissues adjacent to large joints, resulting in joint mobility deficit. In order to determine which treatment techniques are more appropriate for such condition, experimental models of induced heterotopic bone formation have been proposed using heterologous demineralized bone matrix implants and bone morphogenetic protein and other tissues. The objective of the present experimental study was to identify a reliable protocol to induce HO in Wistar rats, based on autologous bone marrow (BM) implantation, comparing 3 different BM volumes and based on literature evidence of this HO induction model in larger laboratory animals. Twelve male Wistar albino rats weighing 350/390 g were used. The animals were anesthetized for blood sampling before HO induction in order to quantify serum alkaline phosphatase (ALP). HO was induced by BM implantation in both quadriceps muscles of these animals, experimental group (EG). Thirty-five days after the induction, another blood sample was collected for ALP determination. The results showed a weight gain in the EG and no significant difference in ALP levels when comparing the periods before and after induction. Qualitative histological analysis confirmed the occurrence of heterotopic ossification in all 12 EG rats. In conclusion, the HO induction model was effective when 0.35 mL autologous BM was applied to the quadriceps of Wistar rats.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to understand the mechanisms of poor osseointegration following dental implants in type 2 diabetics, it is important to study the biological properties of alveolar bone osteoblasts isolated from these patients. We collected alveolar bone chips under aseptic conditions and cultured them in vitro using the tissue explants adherent method. The biological properties of these cells were characterized using the following methods: alkaline phosphatase (ALP) chemical staining for cell viability, Alizarin red staining for osteogenic characteristics, MTT test for cell proliferation, enzyme dynamics for ALP contents, radio-immunoassay for bone gla protein (BGP) concentration, and ELISA for the concentration of type I collagen (COL-I) in the supernatant. Furthermore, we detected the adhesion ability of two types of cells from titanium slices using non-specific immunofluorescence staining and cell count. The two cell forms showed no significant difference in morphology under the same culture conditions. However, the alveolar bone osteoblasts received from type 2 diabetic patients had slower growth, lower cell activity and calcium nodule formation than the normal ones. The concentration of ALP, BGP and COL-I was lower in the supernatant of alveolar bone osteoblasts received from type 2 diabetic patients than in that received from normal subjects (P < 0.05). The alveolar bone osteoblasts obtained from type 2 diabetic patients can be successfully cultured in vitro with the same morphology and biological characteristics as those from normal patients, but with slower growth and lower concentration of specific secretion and lower combining ability with titanium than normal ones.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hip resurfacing arthroplasty (HRA) and large head metal-on-metal total arthroplasty (LDH MoM THA) gained popularity during the last decade. Adverse reaction to metal debris (ARMD) is a unique complication of metal bearings. ARMD is a complex reaction caused by metal debris from metal-on- metal bearing surfaces and from trunnion corrosion of modular junctions. We analyzed survivorship of 8059 LDH MoM THAs based on data of the Finnish Arthroplasty Register. We found relatively high short-term survivorship for some LDH MoM THAs, but there were remarkable differences between the devices studied. After some alarming reports of failing MoM THAs, we studied the first 80 patients who had received a ReCap-M2a-Magnum implant at our institution and evaluated the prevalence of ARMD. We found a high prevalence of pseudotumors, and, because of this, we discontinued the use of MoM bearings and followed up all patients with a MoM THA. Bone loss due infection, osteolysis or fracture poses a great challenge for reconstructive and fracture surgery. Onlay allografting for both revision and fracture surgery provides mechanical stability and increases bone stock. Bone loss and implant stability must be assessed preoperatively and adequately classified; this provides guidelines for the operative treatment of periprosthetic fractures and revision THA. In our studies on structural allografts union rates were high, although the rates of infections and dislocations were marked. In summary, early results of the use of LDH MoM devices were encouraging. However, the survival of the LDH MoMs varied. The prevalence of adverse reaction to metal debris was high after application of the ReCap-Magnum THA. New implants should be introduced carefully and under close surveillance by University clinics and arthroplasty registers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Depuis les années 90, les Projets Intégrés de Conservation et Développement ont été présentés comme des modèles fonctionnels de développement durable pour un site spécifique dans une perspective de réalisation. Le but est d’intégrer les objectifs biologiques de la conservation aux objectifs sociaux et économiques du développement. Ces projets, qui répondent à de multiples dénominations et stratégies, sont implantés dans des contextes naturellement hétérogènes et dynamiques, où l’aménagement du territoire ne doit pas être un outil de planification étatique, désigné et imposé dans une logique conservationniste. Les aires protégées représentent une certaine vision du rapport entre l’être humain et la nature, apparue dans le contexte nord-américain avec la création des premiers grands parcs nationaux en 1870. Aujourd'hui, la forte volonté d'impliquer la population se heurte avec la difficulté de concilier la gestion de ces espaces avec les pratiques, les nécessités et les intérêts locaux. Le parc naturel Obô, qui occupe 30% du territoire de São Tomé et Principe, doit affronter la difficile intégration entre les représentations de la nature et les usages locaux avec les objectifs globaux des politiques conservationnistes, ainsi qu’avec les intérêts touristiques et économiques des investisseurs locaux et étrangers. Les représentations sociales de la nature, établissant une forme de connaissance pratique, déterminent la vision du monde et la relation qu'un certain groupe social peut avoir avec le territoire. Ainsi, chaque communauté possède ses propres mécanismes d'adaptation au milieu basés sur ce système représentationnel. Dans le cas des communautés sãotoméennes, la nature présente un caractère spirituel (associé à des croyances, des rites et des pratiques médicales traditionnelles) et utilitaire (la nature, à travers l'agriculture, la récolte ou la chasse, répond au besoin de subsistance). L’objectif de ce projet de thèse est donc de mieux comprendre la synergie existante entre savoir endogène et gestion de la biodiversité pour adapter l’aménagement du territoire à la réalité des populations qui y vivent.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L’augmentation de la population âgée dans la société indique que les systèmes de soins de la santé font face à de nouveaux défis. Les hauts niveaux d’incapacité qui en résultent peuvent être réduits par les nouvelles technologies, la promotion de la santé ainsi que des stratégies de prévention. Les écrits scientifiques récents soulignent la supériorité des prothèses dentaires implanto-portées par rapport aux prothèses conventionnelles en termes de satisfaction et de qualité de la vie des patients. Cependant, il n'est toujours pas clair si ces avantages ont des effets positifs à long terme sur la santé orale et générale ainsi que sur la qualité de vie des populations âgées. Objectifs, Hypothèses : Notre but était de mesurer l’impact des prothèses mandibulaires retenues par 2 implants sur la qualité de vie associée à la santé bucco-dentaire et générale ainsi que sur la santé orale et la qualité du sommeil des aînés édentés. Nous avons évalué les hypothèses nulles suivantes : il n'y a aucune différence entre les individus portants des prothèses mandibulaires retenues par 2 implants (IODs) et ceux qui portent des prothèses conventionnelles (CDs), par rapport à la qualité de vie reliée à la santé bucco-dentaire et générale, la santé orale et la qualité du sommeil, un an après avoir reçu leurs nouvelles prothèses. Méthodes : Dans cette étude randomisée contrôlée, 255 aînés ont reçu au hasard IODs ou les CDs, les deux types de prothèses étant opposés à des prothèses maxillaires conventionnelles. La qualité de la vie reliée à la santé bucco-dentaire (OHRQoL) et la santé générale subjective ont été mesurées avec les questionnaires Oral Health Impact Profile (OHIP-20) et Short Form-36 (SF-36) en condition pré-traitement et après un an. La qualité du sommeil et la somnolence diurne ont été mesurées à l’aide du questionnaire Qualité de Sommeil de Pittsburg et de l'Échelle de Somnolence Epworth. La santé orale a été évaluée par un examen clinique. Les variables indépendantes étaient le sens de cohérence et le type de prosthèse, ainsi que des variables socio-démographiques. En utilisant des analyses statistiques bi et multi-factorielles, des comparaisons à l’intérieur d’un même groupe et entre deux groupes ont été effectuées. Résultats : Les différences pré et post traitement pour les cotes OHIP étaient significativement plus grandes pour le groupe IOD que le groupe CD (p<0.05). Le type de traitement et la cote pré-traitement étaient des facteurs significatifs à OHRQoL (p < 0.0001). Dans le groupe CD, il y avait une diminution significative par rapport aux cotes de «Physical Component Scores (PCS)», le fonctionnement physique, le rôle physique et la douleur physique entre les données pré-traitement et un an après le traitement, ce qui indique une diminution au niveau de la santé générale subjective. Dans le groupe IOD, une diminution statistiquement non significative a été remarquée par rapport à toutes les cotes des sous-échelles de SF-36, sauf pour la douleur physique. Le modèle final de régression a démontré qu’après ajustement pour les variables âge, sexe, statut marital et type de traitement, la cote totale finale d’OHIP et les données de bases de PCS prédisaient la cote finale de PCS (p < 0.0001). Aucune corrélation significative entre sens de cohérence et OHRQoL n'a été détectée (r =-0.1; p > 0.05). Les aînés porteurs des prothèses conventionnelles avaient presque 5 fois plus de chance d’avoir une stomatite prothétique que ceux portant des prothèses mandibulaires hybrides retenues par 2 implants (p < 0.0001). Les aînés ayant subjectivement une mauvaise santé générale avaient une qualité de sommeil moins bonne que ceux avec une meilleure santé générale subjective (p < 0.05). Les personnes qui avaient une OHRQoL moins bonne étaient presque 4 fois plus somnolentes pendant le jour que celles avec une meilleure OHRQoL (p=0.003, χ2; OR =3.8 CI 1.5 to 9.8). L'analyse de régression a montré que la santé générale subjective et OHRQoL prévoient la qualité du sommeil (p=0.022 et p=0.001, respectivement) et la somnolence diurne (p=0.017 et p=0.005, respectivement). Conclusions: Les résultats de cette étude suggèrent que, chez les aînés édentés, des prothèses mandibulaires hybrides retenues par deux implants amènent une amélioration significative de la qualité de vie reliée à la santé bucco-dentaire et maintiennent la sensation d’une meilleure santé physique. Des prothèses hybrides implanto-portées peuvent contribuer à la santé orale en réduisant les traumatismes infligés à la muqueuse orale et en contrôlant la stomatite prothétique. Les aînés édentés dont le niveau de qualité de vie reliée à la santé bucco-dentaire est bas, peuvent aussi avoir des troubles de qualité du sommeil.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Cette thèse examine le développement du langage des enfants sourds qui ont reçu un implant cochléaire (IC) en bas âge. Une première étude rapporte une revue systématique qui avait pour but d’évaluer les connaissances actuelles concernant le développement du vocabulaire et de la grammaire chez les enfants qui ont reçu un IC avant l’âge de trois ans. Vingt-huit études ont été sélectionnées; une analyse descriptive de même qu’une méta-analyse ont été effectuées séparément pour chaque aspect du langage évalué (vocabulaire et grammaire, aspect réceptif et expressif). Au résultat, en dépit de la variabilité observée dans les études, il appert que l’implant cochléaire influence positivement le développement langagier; toutefois, seule une minorité de participants aux études a atteint des niveaux de langage comparables à ceux d’enfants entendants de même âge chronologique. La majorité des enfants continuent de présenter divers degrés de retard de langage, tant au plan réceptif qu’expressif, et ce, après jusqu’à cinq années de port de l’appareil. Les résultats suggèrent aussi, malgré la variabilité observée dans les études, que les bénéfices langagiers sont influencés par le fait de recevoir l’implant à deux ans plutôt qu’à trois ans. À partir des tendances retrouvées dans la littérature, les habiletés de vocabulaire et de grammaire chez 27 enfants qui ont reçu l’implant cochléaire en bas âge (entre 8 et 28 mois) ont été comparées avec celles d’un groupe d’enfants entendants, en utilisant des outils d’évaluation standardisés. Alors que les résultats de groupe montrent que les enfants qui reçoivent un IC autour de l’âge de deux ans atteignent des niveaux de langage dans les limites de la normale, les résultats individuels d’un sous-groupe formé de enfants les plus âgés font état de quatre profils de développement, soit des niveaux de langage dans les limites de la normale pour l’ensemble des composantes, un retard généralisé à l’ensemble des composantes, des habiletés lexicales dans la norme assorti d’un retard morphosyntaxique et enfin un profil atypique montrant des disparités importantes à travers les composantes du langage. Dans trois des quatre profils, la compréhension des phrases était particulièrement faible. Ces résultats suggèrent que le fait de recevoir un implant cochléaire entre l’âge d’un et deux ans ne garantit pas l’atteinte de niveaux de langage dans les limites de la normale malgré une expérience de port de l’appareil d’une durée appréciable. Une étape antérieure du développement linguistique a été examinée de plus près dans la troisième étude. La taille et la composition du vocabulaire expressif de onze enfants ayant reçu un IC à un âge moyen de 15 mois ont été comparées à celles de l’échantillon d’enfants entendants ayant servi à établir les normes en français québécois pour le questionnaire Mots et énoncés des Inventaires MacArthur-Bates du développement de la communication (IMBDC). Les scores d’âge équivalent selon la taille totale du vocabulaire des enfants avec IC étaient supérieurs à l’âge auditif (correspondant à la durée de port de l’appareil) mais inférieurs à l’âge chronologique. La représentation grammaticale en fonction de la taille du vocabulaire des enfants avec IC suit la tendance observée dans la norme. Ces résultats suggèrent que le profil lexical des enfants avec implant est très similaire à celui des enfants entendants lorsque le nombre total de mots acquis est le même. Les résultats de cette thèse suggèrent que l’implant peut, de manière générale, avoir un effet « normalisant » sur le langage ; toutefois, il semble que l’amélioration de l’accès auditif ne suffise pas pour rattraper à coup sûr le niveau de langage des pairs entendants dans l’ensemble des composantes du langage. Alors que les habiletés lexicales se rapprochent du profil typique, les habiletés de compréhension morphosyntaxique sont fortement atteintes chez une majorité d’enfants, suggérant un profil apparenté à un trouble de langage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les systèmes de gestion intégrée en environnement et en santé et sécurité du travail (SGI) sont un nouveau paradigme de gestion dans les organisations modernes. Ces systèmes sont construits à partir des normes ISO 14001 et d’OHSAS 18001, basées sur la prévention des risques et le principe de précaution. La littérature sur les SGI témoigne d’un marasme conceptuel prédominant depuis plus de 10 ans; elle insiste sur l’urgence d’un consensus taxinomique et conceptuel afin de définir les systèmes de gestion intégrée et de différencier le mécanisme d’intégration de celui de l’implantation. Cette lacune conceptuelle enlise les connaissances dans un fossé épistémologique, retardant ainsi le débat dans ce nouveau champ d’études. Les rares connaissances dont nous disposons dans ce domaine proviennent de quelques études théoriques et de six études empiriques, toutes préoccupées par la compatibilité des multiples systèmes et des avantages économiques de leur intégration. Les évidences engendrées par ces études sont insuffisantes pour appréhender la dynamique du nouveau paradigme dont les effets demeurent peu connus. Cette situation révèle l’urgence d’agir dans un contexte où l’utilisation des SGI se multiplie, et où leur tendance à minimiser l’importance des risques devient de plus en plus préoccupante. Aucune étude ne s’est encore penchée sur l’implantation d’un SGI en environnement et en santé et sécurité du travail construit uniquement à partir des normes ISO 14001 et d’OHSAS 18001. Cette connaissance est importante pour expliquer les effets de tels systèmes. C’est dans cette perspective que nous avons réalisé cette première étude empirique d’un SGI selon les normes ISO 14001 et d’OHSAS 18001. Nos questions de recherche portent sur le mode, le degré d’implantation, les effets du SGI, ainsi que sur les facteurs contextuels qui interviennent pour expliquer les variations dans le degré d’implantation et les effets du SGI. Il s’agit d’une recherche à prélèvement qualitatif qui repose sur un devis d’étude de cas, avec des niveaux d’analyse imbriqués, et comportant une double visée descriptive et explicative. Notre échantillon, de type raisonné, regroupait trente-cinq intervenants provenant de différentes instances hiérarchiques ; il incluait également des représentants syndicaux. Notre échantillon était composé de 7 usines, accréditées aux normes ISO 14001, OHSAS 18001, et dispersées dans différentes villes du Québec. Ces usines différaient tant par leur technologie, leur âge, leur taille, et leurs types de production. Nos données ont été recueillies en 2004; elles sont basées sur des entrevues semi dirigées, sur des observations directes lors de la visite des lieux; elles s’appuient aussi sur des consultations de documents internes et sur des outils électroniques implantés. La transcription des entrevues effectuée, le contenu des discours a été catégorisé selon les cinq dimensions du SGI: engagement, planification, mise en opération, contrôle et revue de la direction. Une condensation horizontale avait précédé l’analyse de chaque cas et l’analyse transversale des cas selon une approche à la fois inductive et déductive. Les résultats de notre recherche ont révélé deux modes d’implantation : le mode d’enrichissement et le mode de fusion. Ces modes dépendaient de la nature des structures fonctionnelles en place. La visée d’amélioration continue à la base du SGI n’avait pas réussi à concilier les approches traditionnelles bottom up et top down qui ont dominé cette implantation; son mécanisme était guidé par 4 types de stratégies : l’économie des ressources, le contrôle des forces d’influences, la stratégie des fruits faciles à cueillir et la stratégie à petits pas. Pour analyser le degré d’implantation, nous avons tenu compte de l’effort de structuration du SGI et de la force d’utilisation des processus implantés à chacune des cinq dimensions du SGI. Les résultats de notre recherche révèlent une variabilité certaine du degré d’implantation entre les usines d’une part, et entre les processus associés aux cinq dimensions du SGI d’autre part. L’analyse des discours a permis de produire cinq hypothèses qui soutiennent l’effort de structuration et la force d’utilisation du SGI: (i) l’hypothèse de la force de cohésion, (ii) l’hypothèse de la spécificité du processus, (iii) l’hypothèse de la portée du processus, (iv) l’hypothèse de la capacité organisationnelle, (v) l’hypothèse de l’acceptation du changement. L’implantation du SGI était soumise à l’influence de multiples facteurs; ils étaient de nature politique, structurelle et organisationnelle. Ces facteurs avaient agi sur le processus d’implantation en amorçant une cascade d’interactions au cours desquelles leurs forces d’influences se renforçaient, se neutralisaient ou s’additionnaient pour affecter le degré d’implantation. Les facteurs facilitant touchaient surtout l’effort de structuration ; ils incluaient : l’expérience des systèmes de gestion, l’implication de la direction, celle du syndicat ou du CSS, la structure organisationnelle, le niveau d’éducation, l’âge et la taille de l’usine. Quant aux facteurs contraignants, ils agissaient sur la force d’utilisation ; ils incluaient : la lourdeur procédurale, le manque de temps, le manque de formation, le manque de ressources, la culture organisationnelle, la structure organisationnelle, le fossé intergénérationnel, l’absence du syndicat et l’âge de l’usine. Trois effets proximaux escomptés par l’entreprise ont été observés. (i) La rigueur de la gestion était associée à l’application des exigences du SGI; elle touchait la gouvernance en environnement et en santé et sécurité du travail, les mécanismes de gestion et les procédés de production. (ii) La standardisation était reliée au mode d’implantation du SGI; elle concernait les pratiques, les outils, les méthodes de travail et l’organisation des ressources. (iii) La rupture des silos est un effet relié au mode d’implantation du SGI; elle touchait les structures départementales, les frontières professionnelles, les relations et climat de travail. Ces effets proximaux avaient provoqué plusieurs effets émergents, plus distaux: une augmentation du pouvoir de contrôle syndical, un renforcement de la légitimité des recommandations soumises par les spécialistes professionnels, la création de réseaux inter organisationnels et le transfert du savoir. L’implantation du SGI avait transformé la gouvernance et les pratiques en environnement et en santé et sécurité du travail dans les sept usines. Toutefois, elle ne semblait pas garantir l’immunité du processus de gestion des risques à l’environnement ni à la santé et sécurité du travail. Sa capacité à diluer les risques devait retenir l’attention des politiques de santé publiques et des programmes de prévention des risques à l’environnement et à la santé et sécurité du travail. L’amélioration de la gestion des risques demeurait un effet attendu non observé et soumis à des facteurs contextuels qui pourraient l’empêcher de se concrétiser. À cet égard, le transfert du savoir, renforcé par l’émergence des réseaux inter organisationnels, semblait offrir une avenue beaucoup plus prometteuse et accessible. C’est l’une des contributions de cette recherche. Elle a aussi (i) proposé une typologie des modes d’implantation et des effets du SGI (ii) préconisé une méthode détaillée d’une meilleure appréciation du degré d’implantation (iii) précisé le rôle des facteurs contextuels dans l’explication des variations du degré d’implantation et dans la production des effets, (iv) proposé des hypothèses sur la structuration et l’utilisation du SGI (v) offert une perspective plurielle et approfondie de la dynamique de l’implantation du SGI grâce à la variété de l’échantillon des répondants et des usines. Il s’agit de la première étude de terrain dans le domaine. À notre connaissance, aucune autre étude n’a eu de tels résultats. Mots Clés : ISO 14001, OHSAS 18001, gestion intégrée, environnement, santé et sécurité du travail, risques environnementaux, risques en santé et sécurité du travail, analyse d’implantation, degré d’implantation, SGI, transfert du savoir.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La supériorité des prothèses mandibulaires retenues par deux implants (IODs) sur les prothèses conventionnelles (CDs) nécessitent d’être éclaircies notamment en rapport à leur influence sur la qualité de vie reliée à la santé bucco-dentaire (OHRQoL) ainsi que sur la stabilité de cet effet de traitement. De plus, l’influence des facteurs psychologiques, tel que le sens de cohérence (SOC), sur l’effet de traitement reste encore inconnue. Le but de cette étude est de déterminer l’amplitude de l’influence du port des IODs et des CDs sur l’OHRQoL et d’évaluer la stabilité de l’effet de traitement dans le temps, tout en prenant en considération le niveau du SOC. MÉTHODOLOGIE: Des participants édentés (n=172, âge moyen 71, SD = 4.5) ayant reçu des CDs ou des IODs ont été suivis sur une période de deux ans. L’OHRQoL a été évaluée à l’aide du questionnaire « Oral Health Impact Profile (OHIP -20) » et ce avant le traitement et à chacun des deux suivis. Le SOC a été évalué à l’aide du questionnaire « The Orientation to Life (SOC -13) » à chacun des deux suivis. Des analyses statistiques ont été effectuées pour évaluer les différences intra et entre groupes (analyses statistiques descriptives, bivariées et multivariées). RÉSULTATS: Une amélioration statistiquement significative de l’OHRQoL entre les statuts avant et après traitement a été notée dans les deux groupes (Wilks’s Lambda = 0.473, F (1,151) = 157.31, p < 0.0001). L’amplitude de l’effet du traitement IOD est 1.5 fois plus grande que celle du traitement CD. Ces résultats ont été stables pendant les deux années d’étude et ils n’ont pas été influencés par le SOC. CONCLUSION: Le traitement IOD amène une meilleure OHRQoL à long terme en comparaison avec le traitement CD et ce sans influence du niveau du SOC. Ces résultats sont cliniquement significatifs et confirment la supériorité des IODs sur les CDs.