1000 resultados para EFFICIENCY CALIBRATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The two-photon resonances of atomic hydrogen (? = 2 × 205.1 nm), atomic nitrogen (? = 2 × 206.6 nm) and atomic oxygen (? = 2 × 225.6 nm) are investigated together with two selected transitions in krypton (? = 2×204.2 nm) and xenon (? = 2×225.5 nm). The natural lifetimes of the excited states, quenching coefficients for the most important collisions partners, and the relevant ratios of the two-photon excitation cross sections are measured. These data can be applied to provide a calibration for two-photon laser-induced fluorescence measurements based on comparisons with spectrally neighbouring noble gas resonances.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements of collisional de-excitation (quenching) coefficients required for the interpretation of emission and fluorescence spectroscopic measurements are reported. Particular attention is turned on argon transitions which are of interest for actinometric determinations of atomic ground state populations and on fluorescence lines originating from excited atoms and noble gases in connection with two-photon excitation (TALIF) of atomic radicals. A novel method is described which allows to infer quenching coefficients for collisions with molecular hydrogen of noble gas states in the energy range up to 24 eV. The excitation is performed in these experiments by collisions of energetic electrons in the sheath of an RF excited hydrogen plasma during the field reversal phase which lasts about 10 ns. We describe in addition a calibration method - including quenching effects - for the determination by TALIF of absolute atomic radical densities of hydrogen, nitrogen and oxygen using two-photon resonances in noble gases close by the resonances of the species mentioned. The paper closes with first ideas on a novel technique to bypass quenching effects in TALIF by introducing an additional, controllable loss by photoionization that will allow quenching-free determination of absolute atomic densities with prevalent nanosecond laser systems in situations where collisional de-excitation dominates over spontaneous emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The electrochemical generation of ozone by Ni/Sb-SnO2 anodes immersed in 0.5M H2SO4 was assessed in both flow and recycle systems using the same electrochemical cell. The anodes were found to exhibit current efficiencies of up to 50% for ozone generation under flow conditions at room temperature, with an optimum mole ratio in the precursor solutions of ca. 500:8:3 Sn:Sb:Ni and optimum cell voltage of 2.7V. A comparison of the data obtained under flow and recycle conditions suggests that the presence of ozone in the anolyte inhibits its formation. The minimum electrical energy cost achieved, of 18 kWh kg1 compares favorably with estimated costs for Cold Corona Discharge generally reported in the literature, especially when the very significant advantages of electrochemical ozone generation are taken into account.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To increase eco-efficiency environmental information needs to be integrated into corporate decision making. For decision makers the interpretation of eco-efficiency as a ratio can however be quite difficult in practice. One of the reasons for this is, that eco-efficiency as a ratio is measured in a unit, that is difficult to interpret. This article therefore suggests an alternative measure for eco-efficiency. The Environmental Value Added, the measure proposed in this paper, reflects the excess economic benefit, resulting from the difference between the eco-efficiency under consideration and a benchmark eco-efficiency. It is measured in a purely monetary unit and is thus easier to interpret and integrate than eco-efficiency as a ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivation: Many biomedical experiments are carried out by pooling individual biological samples. However, pooling samples can potentially hide biological variance and give false confidence concerning the data significance. In the context of microarray experiments for detecting differentially expressed genes, recent publications have addressed the problem of the efficiency of sample pooling, and some approximate formulas were provided for the power and sample size calculations. It is desirable to have exact formulas for these calculations and have the approximate results checked against the exact ones. We show that the difference between the approximate and the exact results can be large.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Extraction of dibenzothiophene from dodecane using ionic liquids as the extracting phase has been investigated for a range of ionic liquids with varying cation classes (imidazolium, pyridinium, and pyrrolidinium) and a range of anion types using liquid-liquid partition studies and QSPR (quantitative structure-activity relationship) analysis. The partition ratio of dibenzothiophene to the ionic liquids showed a clear variation with cation class (dimethylpyridinium > methylpyridinium > pyridinium approximate to imidazolium approximate to pyrrolidinium), with much less significant variation with anion type. Polyaromatic quinolinium-based ionic liquids showed even greater extraction potential, but were compromised by higher melting points. For example, 1-butyl-6-methylquinolinium bis{(trifluoromethyl)sulfonyl} amide (mp 47 degrees C) extracted 90% of the available dibenzothiophene from dodecane at 60 degrees C.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Special issue on Sensor Systems for Structural Health Monitoring Abstract—This study addresses the direct calibration of optical fiber strain sensors used for structural monitoring and is carried out in situ. The behavior of fiber-Bragg-grating-based sensor systems when attached to metal bars, in a manner representative of their use as reinforcement bars in structures, was examined and their response calibrated. To ensure the validity of the measurements,this was done using an extensometer with a further calibrationagainst the response of electrical resistance strain gauges, often conventionally used, for comparison. The results show a repeatable calibration generating a suitable geometric factor of extension to strain for these sensors, to enable accurate strain data to be obtained when the fiber-optic sensor system is in use in structural monitoring applications.