955 resultados para Diurnal Type Scale
Resumo:
The ability to control human immunodeficiency virus type 1 (HIV-1) infection and progression of the disease is regulated by host and viral factors. This cross-sectional study describes the socio-demographic and epidemiological characteristics associated with HIV-1 infection in 1,061 subjects attended in Londrina and region, south of Brazil: 136 healthy individuals (Group 1), 147 HIV-1-exposed but uninfected individuals (Group 2), 161 HIV-1-infected asymptomatic patients (Group 3), and 617 patients with AIDS (Group 4). Data were obtained by a standardized questionnaire and serological tests. The age of the individuals ranged from 15.1 to 79.5 years, 54.0% and 56.1% of the Groups 3 and 4 patients, respectively, were men. The major features of groups 2, 3, and 4 were a predominance of education level up to secondary school (55.8%, 60.2% and 62.4%, respectively), sexual route of exposure (88.4%, 87.0% and 82.0%, respectively), heterosexual behavior (91.8%, 75.2% and 83.7%, respectively), and previous sexually transmitted diseases (20.4%, 32.5%, and 38.1%, respectively). The patients with AIDS showed the highest rates of seropositivity for syphilis (25.6%), of anti-HCV (22.3%), and anti-HTLV I/II obtained by two serological screening tests (6.2% and 6.8%, respectively). The results documenting the predominant characteristics for HIV-1 infection among residents of Londrina and region, could be useful for the improvement of current HIV-1 prevention, monitoring and therapeutic programs targeted at this population.
Resumo:
This paper describes the development and testing of a robotic capsule for search and rescue operations at sea. This capsule is able to operate autonomously or remotely controlled, is transported and deployed by a larger USV into a determined disaster area and is used to carry a life raft and inflate it close to survivors in large-scale maritime disasters. The ultimate goal of this development is to endow search and rescue teams with tools that extend their operational capability in scenarios with adverse atmospheric or maritime conditions.
Resumo:
Canadian Journal of Civil Engineering 36(10) 1605–16
Resumo:
In this study, energy production for autonomous underwater vehicles is investigated. This project is part of a bigger project called TURTLE. The autonomous vehicles perform oceanic researches at seabed for which they are intended to be kept operational underwater for several months. In order to ful l a long-term underwater condition, powerful batteries are combined with \micro- scale" energy production on the spot. This work tends to develop a system that generates power up to a maximum of 30 W. Latter energy harvesting structure consists basically of a turbine combined with a generator and low-power electronics to adjust the achieved voltage to a required battery charger voltage. Every component is examined separately hence an optimum can be de ned for all, and subsequently also an overall optimum. Di erent design parameters as e.g. number of blades, solidity ratio and cross-section area are compared for di erent turbines, in order to see what is the most feasible type. Further, a generator is chosen by studying how ux distributions might be adjusted to low velocities, and how cogging torque can be excluded by adapted designs. Low-power electronics are con gured in order to convert and stabilize heavily varying three-phase voltages to a constant, recti ed voltage which is usable for battery storage. Clearly, di erent component parameters as maximum power and torque are matched here to increase the overall power generation. Furthermore an overall maximum power is set up for achieving a maximum power ow at load side. Due to among others typical low velocities of about 0.1 to 0.5 m/s, and constructing limits of the prototype, the vast range of components is restricted to only a few that could be used. Hence, a helical turbine is combined in a direct drive mode to a coreless-stator axial- ux permanent-magnet generator, from which the output voltage is adjusted subsequently by a recti er, impedance matching unit, upconverter circuit and an overall control unit to regulate di erent component parameters. All these electronics are combined in a closed-loop design to involve positive feedback signals. Furthermore a theoretical con guration for the TURTLE vehicle is described in this work and a solution is proposed that might be implemented, for which several design tests are performable in a future study.
Resumo:
The basidiomycetous yeast Cryptococcus neoformans is an important fungal pathogen mainly in immunocompromised patients. In this study, 47 clinical isolates of C. neoformans from regions of São Paulo State were studied serologically by using the Crypto Check Iatron RM 304-K kit, their genetic diversity was estimated by PCR-fingerprinting with a microsatellite-specific sequence (GACA)4, RAPD with primer 6 (Amersham Pharmacia Biotech), PCR-restriction fragment length polymorphism (RFLP) analysis of the phospholipase B gene (PLB1) digested with AvaI and mating type analysis by PCR. All 47 strains isolated from HIV positive patients included in this study were serotype A and MATalpha. The majority of the isolates (45/47) were VNI and only two were VNII by PCR-fingerprinting and PCR-RFLP analysis. High degree of homogeneity was observed when (GACA)4 was used, being highly correlated (> 0.9). In contrast, the RAPD analysis was more heterogeneous with higher number of molecular profiles. By PCR-RFLP, no new molecular type was found, enhancing the suggestion that the differences based on conserved gene as PLB1, can be resultant of ongoing divergent evolution within the C. neoformans complex, into the current eight subtypes. Our results furnish new information on the molecular epidemiology of C. neoformans in the southeast region of Brazil.
Resumo:
Cryptococcus neoformans is an encapsulated yeast, etiological agent of cryptococcosis. The species is commonly associated with pigeon droppings and plant materials. The aim of the present work was to verify the presence of the yeast in pigeon droppings, and to identify the isolates obtained in serotypes and mating types (MAT). Ten samples of pigeon droppings were collected in the rural area of the city of Alfenas, Brazil. Samples were inoculated in agar Niger medium for fungal isolation and 22 isolates with characteristics of C. neoformans were obtained. The serotypes and MAT were determined by multiplex PCR using specific primers. Serotypes were also determined by using the Kit Crypto Check. Among the 22 samples evaluated, eight were identified as C. neoformans by classic identification tests. These samples were characterized as serotype A by the Kit Crypto check and as serotype A MAT alpha by the multiplex PCR. The present study reinforces the evidence that pigeon droppings are a reservoir for C. neoformans and confirms the prevalence of C. neoformans var. grubii (Aalpha) among environmental isolates. It also demonstrates that multiplex PCR is an acceptable alternative for serotype analysis because it reduces the costs for each reaction and analyses serotype and MAT simultaneously.
Resumo:
INTRODUCTION: HIV positive patients co-infected with HTLV-1 may have an increase in their T CD4+ cell counts, thus rendering this parameter useless as an AIDS-defining event. OBJECTIVE: To study the effects induced by the co-infection of HIV-1 and HTLV-1 upon CD4+ cells. MATERIAL AND METHODS: Since 1997, our group has been following a cohort of HTLV-1-infected patients, in order to study the interaction of HTLV-1 with HIV and/or with hepatitis C virus (HCV), as well as HTLV-1-only infected asymptomatic carriers and those with tropical spastic paraparesis/HTLV-1 associated myelopathy (TSP/HAM). One hundred and fifty HTLV-1-infected subjects have been referred to our clinic at the Institute of Infectious Diseases "Emílio Ribas", São Paulo. Twenty-seven of them were also infected with HIV-1 and HTLV-1-infection using two ELISAs and confirmed and typed by Western Blot (WB) or polymerase chain reaction (PCR). All subjects were evaluated by two neurologists, blinded to the patient's HTLV status, and the TSP/HAM diagnostic was based on the World Health Organization (WHO) classification. AIDS-defining events were in accordance with the Centers for Disease Control (CDC) classification of 1988. The first T CD4+ cells count available before starting anti-retroviral therapy are shown compared to the HIV-1-infected subjects at the moment of AIDS defining event. RESULTS: A total of 27 HIV-1/HTLV-1 co-infected subjects were identified in this cohort; 15 already had AIDS and 12 remained free of AIDS. The median of T CD4+ cell counts was 189 (98-688) cells/mm³ and 89 (53-196) cells/mm³ for co-infected subjects who had an AIDS-defining event, and HIV-only infected individuals, respectively (p = 0.036). Eight of 27 co-infected subjects (30%) were diagnosed as having a TSP/HAM simile diagnosis, and three of them had opportunistic infections but high T CD4+ cell counts at the time of their AIDS- defining event. DISCUSSION: Our results indicate that higher T CD4+ cells count among HIV-1/HTLV-1-coinfected subjects was found in 12% of the patients who presented an AIDS-defining event. These subjects also showed a TSP/HAM simile picture when it was the first manifestation of disease; this incidence is 20 times higher than that for HTLV-1-only infected subjects in endemic areas.
Resumo:
HHV-6 is the etiological agent of Exanthem subitum which is considered the sixth most frequent disease in infancy. In immuno-compromised hosts, reactivation of latent HHV-6 infection may cause severe acute disease. We developed a Sybr Green Real Time PCR for HHV-6 and compared the results with nested conventional PCR. A 214 pb PCR derived fragment was cloned using pGEM-T easy from Promega system. Subsequently, serial dilutions were made in a pool of negative leucocytes from 10-6 ng/µL (equivalent to 2465.8 molecules/µL) to 10-9 (equivalent to 2.46 molecules/µL). Dilutions of the plasmid were amplified by Sybr Green Real Time PCR, using primers HHV3 (5' TTG TGC GGG TCC GTT CCC ATC ATA 3)'and HHV4 (5' TCG GGA TAG AAA AAC CTA ATC CCT 3') and by conventional nested PCR using primers HHV1 (outer): 5'CAA TGC TTT TCT AGC CGC CTC TTC 3'; HHV2 (outer): 5' ACA TCT ATA ATT TTA GAC GAT CCC 3'; HHV3 (inner) and HHV4 (inner) 3'. The detection threshold was determined by plasmid serial dilutions. Threshold for Sybr Green real time PCR was 24.6 molecules/µL and for the nested PCR was 2.46 molecules/µL. We chose the Real Time PCR for diagnosing and quantifying HHV-6 DNA from samples using the new Sybr Green chemistry due to its sensitivity and lower risk of contamination.
Resumo:
Human Immunodeficiency Vírus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and imunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS - Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 ºC, -20 ºC and -70 ºC, while the second was composed of two negative and three positive samples stored at 37 ºC (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.
Resumo:
Hepatitis C virus (HCV) and human T-cell lymphotropic virus type 1 (HTLV-1) share routes of transmission and some individuals have dual infection. Although some studies point to a worse prognosis of hepatitis C virus in patients co-infected with HTLV-1, the interaction between these two infections is poorly understood. This study evaluated the influence of HTLV-1 infection on laboratory parameters in chronic HCV patients. Twelve HTLV-1/HCV-coinfected patients were compared to 23 patients infected only with HCV, in regard to demographic data, risk factors for viral acquisition, HCV genotype, presence of cirrhosis, T CD4+ and CD8+ cell counts and liver function tests. There was no difference in regard to age, gender, alcohol consumption, smoking habits, HCV genotype or presence of cirrhosis between the groups. Intravenous drug use was the most common risk factor among individuals co-infected with HTLV-1. These patients showed higher TCD8+ counts (p = 0.0159) and significantly lower median values of AST and ALT (p = 0.0437 and 0.0159, respectively). In conclusion, we have shown that HCV/HTLV-1 co-infected patients differs in laboratorial parameters involving both liver and immunological patterns. The meaning of these interactions in the natural history of these infections is a matter that deserves further studies.