991 resultados para DIRECT-INJECTION
Resumo:
A compact continuous-wave blue laser has been demonstrated by direct frequency doubling of a laser diode with a periodically poled lithium niobate (PPLN) waveguide crystal. The optimum PPLN temperature is near 28 degreesC, and the dependence of waveguide crystals on crystal temperature is less sensitive than that of bulk crystals. A total of 14.8 mW of 488-nm laser power has been achieved. (C) 2005 Optical Society of America.
Resumo:
A diode pumped injection seeded single-longitudinal-mode (SLM) Nd:YAG laser is achieved by using the resonance-detection technique in Q-switching operation. The pulsed oscillator laser uses a folded cavity to achieve compact construction. This system operates at 100 Hz and provides over 20 mJ/pulse of single-frequency 1064 nm output. The M-2 values of horizontal and vertical axes are 1.58 and 1.41, respectively. The probability of putting out single-longitudinal-mode pulses is 100%. The 355 nm laser output produced by frequency tripling has a linewidth less than 200 MHz. The laser can run over eight hours continually without mode hopping.
Resumo:
The FOB-3, anew type fiber optic biosensor, is designed to rapidly detect a variety of biological agents or analytes with better stability, sensitivity and specificity. In order to detect Y. Pestis, a sandwich immunoassay was developed by using the purified antibody against antigen FI immobilized on polystyrene probes as the capture antibody and the monoclonal antibody-Cy5 conjugate as the detector. After a series of optimization for the stability, sensitivity and specificity of the FOB-3, 50-1000 ng/ml of antigen FI and 6 x 10(1)-6 x 10(7) CFU/ml Y. pestis could be detected constantly in about 20 min, and Y pestis could be detected specifically from Y. pseudotuberculosis, Y. enterocolitica, B. anthracis and E. coli. Then, 39 blind samples, including 27 tissues of mice infected with Y pestis and 12 tissues of healthy mice as negative control, were detected with the FOB-3. 92.6% infected tissues were identified from the tissues of healthy mice and the tissues containing more than 100 CFU/ml bacteria could be detected by the biosensor. The results demonstrated the feasibility of the FOB-3 as an effective method to detect Y. pestis rapidly and directly from the infected animal specimens with the advantage of portability, simple-operation as well as high sensitivity and specificity. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Writing computer-generated holograms has been achieved by using near infrared femtosecond laser selective ablation of metal film deposited on glass substrate. The diffraction features with data reconstruction of fabricated computer-generated holograms were evaluated. Both transmission and reflection holograms can be fabricated in a single process. The process required no mask, no pre- or post-treatment of the substrate. (C) 2005 Optical Society of America.
Resumo:
In this paper, we report the synthesis of high-luminance Y2O3:Eu nanocrystal through a citrate-nitrate complexation combustion method at a low temperature of 200-280 degrees C. The as-combusted Y2O3:Eu phosphors are almost equiaxed crystallites with an average size of 30-40 run, and have an intense red luminescence. The present fuel-deficient method suggests that by control of the ratio of citric acid to nitrates, it is valuable for the fabrication of Y2O3 nanoparticles without heat treatment. This process should be applicable to a wide range of nanocrystal oxides.
Resumo:
A descarga desenfreada de águas residuais no meio ambiente, ao longo dos últimos anos, vem acelerando o processo de contaminação e degradação dos corpos hídricos no mundo. Tais rejeitos apresentam elevada carga de contaminantes e de concentração de matéria orgânica o que leva a mortandade das espécies pela concorrência ao oxigênio e, em casos extremos, a aceleração dos processos de eutrofização. Pensando nisso, o presente trabalho estudou um sistema híbrido, em batelada, de tratamento de águas oleosas simuladas em laboratório pela adição de um determinado óleo lubrificante em uma solução aquosa de agentes emulsificantes e eletrólito suporte. O sistema de tratamento foi composto de duas etapas, onde na primeira avaliou-se o uso da técnica da eletrofloculação, responsável por quebrar a estabilidade das emulsões óleo/água e de uma segunda que avaliou o uso de processos de separação com membranas visando à remoção do metal adicionado ao efluente na etapa anterior. O sistema de eletrofloculação foi avaliado em relação ao uso de eletrodos de alumínio e ferro com correntes elétricas de 1A, 2A e 3A, nos modos contínuo e alternado. Os resultados apontaram um maior consumo evidente de massa de eletrodos quando do uso da corrente contínua, 4,0337g 0,0132 para o alumínio e 3,8260g 0,0181 para o ferro ao passo que o consumo foi de 2,1400g 0,0099 para o alumínio e 2,4121g 0,0127 para o ferro quando do o uso da corrente alternada. Foram alcançadas remoções máximas de 98 % 0 da DQO, 99,77 % 0,27 de remoção da cor e 100 % 0 de remoção da turbidez para o uso de corrente alternada e eletrodos de alumínio enquanto se alcançaram remoções máximas 96 % 1 da DQO, 99,46 % 0,82 de remoção da cor e também 100 % 0 de remoção da turbidez no uso de eletrodos de ferro. Na segunda etapa do estudo, a osmose inversa, o sistema utilizado atingiu rejeições de 99,53 % 0,12; 99,56 % 0,13 e de 98,87 % 0,36, para pressões respectivas de 10, 20 e 30 bar. Além disso, foram obtidos fluxos crescentes de permeado 10,87 L/h.m2 0,25; 15,67 L/h.m2 0,53; 18,49 L/h.m2 0,74 com o também aumento da pressão. Ao final do estudo alcançou-se um efluente final com baixa carga orgânica e de metais, estando o mesmo apto ao lançamento nos corpos receptores. Entretanto, mecanismos de controle, sobretudo de pH devem ser incluídos no projeto desses sistemas uma vez que esse parâmetro sofre alterações ao longo do processo