977 resultados para Colocação de implantes justacrestalmente
Resumo:
With advances in health care, has been na increase of demand for material that could replace the functions of the human body parts, thus evolved biomedic prosthesis which today are responsible for the constant improvement of the quality of life. The Titanium alloys are widely used as implants due to its properties, like high mechanical resistance, biocompatibility and corrosion resistance, and the addition alloying elements like Zirconium, may improve some of those properties. Such properties are related to the microstructure and consequently to the type of processing performed. The purpose of this dissertation was to characterize the experimental alloy Ti15Zr after route of processsing and heat treatment in order to extend the knowledge about this alloy. The latter has been abtained by fusion of pure metals in a arc melting furnace with an inert argon atmosphere. The material has been homogenized in a tube furnace at 950ºC for 24h and cold worked by swaging, after that, bars with 10 mm of diameter were obtained by the process of rotary forging. The samples were solubilized at 900º C for 2 hours and quenched in water. After that, 4 samples were submitted to the aging, at 400º C, 450º C, 500º C and 550º C. The microstructure and phase analysis was done by optical microscopy and X-rays diffraction (XRD), the mechanical characterization was carried out by microhardness test and finally, evaluation of corrosion resistance of the alloy by electrochemical tests. The XRD and the optical microscopy made it possible to analyze that the heat treatment influenced the phase shifting from α to α', and probably affected the alloy hardness, at the first aged sample at 500º Chas been a sudden increase in the value of hardness, probably by appearance of omega phase, unwanted phase to the medical application duo to great fragility, and finally ... (Complete abstract click electronic access below)
Resumo:
Pós-graduação em Bases Gerais da Cirurgia - FMB
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Purpose: Implant-abutment connections still present failures in the oral cavity due to the loosening of mechanical integrity by detorque and corrosion of the abutment screws. The objective of this study was to evaluate the detorque of dental abutment screws before and after immersion in fluoridated solutions. Materials and Methods: Five commercial implant-abutment assemblies were assessed in this investigation: (C) Conex˜aoR , (E) EmfilsR , (I) INPR , (S) SINR , and (T) Titanium FixR . The implants were embedded in an acrylic resin and then placed in a holding device. The abutments were first connected to the implants and torqued to 20Ncmusing a handheld torque meter. The detorque values of the abutments were evaluated after 10 minutes. After applying a second torque of 20 Ncm, implant-abutment assemblies were withdrawn every 3 hours for 12 hours in a fluoridated solution over a period of 90 days. After that period, detorque of the abutments was examined. Scanning electronicmicroscopy (SEM) associated to energy dispersive spectroscopy (EDS) was applied to inspect the surfaces of abutments. Results: Detorque values of systems C, E, and I immersed in the fluoridated solution were significantly higher than those of the initial detorque. ANOVA demonstrated no significant differences in detorque values between designs S and T. Signs of localized corrosion could not be detected by SEM although chemical analysis by EDS showed the presence of elements involved in corrosive processes. Conclusion: An increase of detorque values recorded on abutments after immersion in fluoridated artificial saliva solutions was noticed in this study. Regarding chemical analysis, such an increase of detorque can result from a corrosion layer formed between metallic surfaces at static contact in the implant-abutment joint during immersion in the fluoridated solutions.
Resumo:
Treatment of patients with cleft lip and palate is completed with fixed prostheses, removable, total, implants and aims to restore aesthetics, phonetics and function and should be guided by the basic principles of oral rehabilitation, such as physiology, stability, aesthetics, hygiene and the expectations of the patient. In order to obtain longevity of a prosthetic rehabilitation, the periodontal and dental tissue as well as the biomechanics of the prosthesis are to be respected. The purpose of this article is to describe the types of prosthetics treatment, which are performed at HRAC/USP for the rehabilitation of cleft area in adult patients.
Resumo:
Purpose of this study was to evaluate the influence of miniscrew dental root proximity on its late stability degree. 40 miniscrews were inserted between maxillary second premolars and first molars for anterior retraction. Post-surgical radiographs were used to measure the septum width in the insertion site, insertion height, distal and mesial distance from miniscrew to dental root, and the smallest distance between miniscrew and dental root. The miniscrews were divided in two groups according to septum width: ?3 mm (20 miniscrews) and >3 mm (20 miniscrews). The soft tissue in the insertion site, sensitivity during load, plaque around the miniscrew, and evaluation period were also considered. The results showed no significant difference in miniscrew mobility degree and success rate between groups. Miniscrew dental root proximity did not influence the stability and success rate when the distance between the miniscrew and dental root indicated no periodontal ligament invasion. The overall success rate was 90% and no variable was associated with miniscrew failure. Nevertheless, patient sensitivity was frequently associated with some degree of mini-implant mobility. The septum width did not influence the stability and success rate of this anchorage system, but the extreme root proximity did.
Resumo:
The main objective of this paper was to discuss the importance of the reverse planning as guidance to surgical procedures on immediate loading implant-retained prosthesis, presenting a case report. Such design aims to define anchorage orientation after determination of prosthetic design. This is quite important because the possibility of success of cases with this kind of planning may achieve high levels of satisfaction. Another important aspect is the possibility of fast and definitive restoration of patients’ function and aesthetics
Resumo:
Introduction: Passive fit has been considered an important requirement for the longevity of implant-supported prostheses. Among the different steps of prostheses construction, casting is a feature that can influence the precision of fit and consequently the uniformity of possible deformation among abutments upon the framework connection. Purpose: This study aimed at evaluating the deformation of abutments after the connection of frameworks either cast in one piece or after soldering. Materials and Methods: A master model was used to simulate a human mandible with 5 implants. Ten frameworks were fabricated on cast models and divided into 2 groups. Strain gauges were attached to the mesial and distal sides of the abutments to capture their deformation after the framework’s screw retentions were tightened to the abutments. Results: The mean values of deformation were submitted to a 3-way analysis of variance that revealed significant differences between procedures and the abutment side. The results showed that none of the frameworks presented a complete passive fit. Conclusion: The soldering procedure led to a better although uneven distribution of compression strains on the abutments.
Resumo:
Objective: To evaluate healing time before loading, areas compression and tension and location of insertion on mini-implant stability. Design: Six minipigs were used. Each animal received 3 mini-implants in each quadrant: 1 mini-implant was used as an unloaded control (G1, n = 24); the other 2 were loaded with 150 g-force at three time intervals (G2: immediate loading, G3: after 15 days and G4: after 30 days), with 16 mini-implant in each experimental group. After 120 days, tissue blocks of the areas of interest were harvested. Clinical analysis (exact Fisher test) determined the survival rate. Histological analysis (Kontron KS 300TM, Zeiss) quantified the fractional bone-toimplant contact (%BIC) and bone area (%BA) at each healing time point, areas of interest, and insertion site (ANOVA and t tests for dependent and independent samples). Results: The mini-implant survival rates were G1: 71%, G2: 50%, G3: 75% and G4: 63%, with no statistical differences between them. The groups presented similar %BIC and %BA. There were no differences between the compression and tension sides or maxillary and mandibular insertion sites. Conclusions: These results suggest that low-intensity immediate or early orthodontic loading does not affect mini-implant stability, because similar histomorphometric results were observed for all the groups, with partial osseointegration of the mini-implants present.
Resumo:
Objective: To evaluate the aesthetics of an implant-supported denture at the cleft area, comparing the peri-implant tissues and prosthetic crown with the contralateral tooth. Settings: Hospital for Rehabilitation of Craniofacial Anomalies, Bauru, São Paolo, Brazil. Patients: A total of 39 individuals of both genders, with complete unilateral cleft lip and palate, who received secondary alveolar bone graft and were rehabilitated with single implant-supported dentures at the area of the missing maxillary lateral incisor after completion of orthodontic treatment. Interventions: The following parameters were analyzed in follow-up sessions: length and width of prosthetic crown and contralateral tooth, characteristics of implants, filling of interproximal space by the papilla, and smile height of the patients. Results: The implant-supported prosthetic crowns were longer than the contralateral tooth (p < .001). Among the 78 papillae analyzed, 29 (37.17%) received a score of 3; 32 (41.02%) papillae had a score of 2; and 17 (21.79%) received a score of 1. Concerning the smile height, among the 39 patients analyzed, 23 (56.41%) had a medium smile, 15 (38.46%) had a high smile, and two (5.12%) presented a low smile. Conclusion: The use of dental implants to rehabilitate the edentulous cleft area is an excellent option. However, adequate evaluation of the bone quantity and quality, positioning and shape of adjacent teeth, smile height, and patient expectations should be considered to achieve success and avoid aesthetic deformities such as elongated teeth and absence of gingival papillae.
Resumo:
OBJETIVO: Estudo anatômico do áxis através de tomografia computadorizada (TC) em crianças de dois a dez anos de idade, mensurando a angulação das lâminas, espessura e comprimento de lâminas e pedículos e espessura da massa lateral. MÉTODOS: Estudou-se 64 TCs da coluna cervical de indivíduos com idades entre 24 e 120 meses, de ambos os sexos e sem deformidades cervicais. Correlacionaram-se as variáveis estudadas com os grupos etários e sexo dos pacientes. A análise estatística foi realizada por meio do teste t. RESULTADOS: Verificou-se que na faixa etária entre 24-48 meses, 5,5% das lâminas e 8,3% dos pedículos possuem espessura menores do que 3,5mm, espessura necessária para colocação de um parafuso. Entre 49-120 meses não há lâminas com espessuras menores do que 3,5mm e 1,2% dos pedículos possuem espessura menor do que 3,5mm. Em ambos os grupos etários não há comprimento de lâminas e pedículos menores do que 12 mm e massas laterais maiores do que 12 mm. CONCLUSÃO: A análise das dimensões obtidas no estudo permite, na maioria dos casos, a colocação de parafusos de 3,5mm nas lâminas e pedículos do áxis de crianças. Nível de Evidência II, Desenvolvimento de critérios diagnósticos em pacientes consecutivos.
Resumo:
Considerando a indisponibilidade de equipamentos avançados de aquisição de imagens nos centros cirúrgicos da maioria dos centros hospitalares e a importância fundamental que têm para o cirurgião uma visualização imediata do implante coclear logo após sua inserção, uma boa opção é a utilização da radiografia convencional. OBJETIVO: Descrever um método radiográfico rápido prático e de baixo custo, que permita avaliar não só a posição, mas também a integridade dos eletrodos, na instalação do implante coclear. MATERIAL E MÉTODO: Foram analisadas radiografias de 262 pacientes submetidos à cirurgia de implante coclear entre Março/2005 e Outubro/2008, com radiografia transoperatória, logo após a inserção dos eletrodos. As radiografias foram analisadas pelo cirurgião no transoperatório e, posteriormente, pelo médico radiologista. RESULTADOS: Foram analisadas 524 radiografias das quais, 95,61% apresentavam técnica adequada, com posicionamento do paciente dentro da técnica descrita neste estudo e boa visualização dos eletrodos, sendo consideradas satisfatórias e 4,39% apresentavam técnica inadequada e/ou visualização insatisfatória dos eletrodos, sendo consideradas insatisfatórias. CONCLUSÃO: Apesar dos aparelhos de Raios X portáteis possuírem limitações, utilizando técnicas e acessórios adequados, é possível conseguir radiografias com resultados satisfatórios para visualização dos implantes cocleares.
Resumo:
Devido aos avanços na tecnologia dos implantes cocleares e das estratégias de processamento, indivíduos com surdez grave a profunda puderam ouvir sons e reconhecer fala em diferentes graus. A variabilidade nos resultados audiológicos em portadores de surdez pós-lingual tem sido grande e a indicação para o implante coclear tem se estendido e inclui uma população cada vez maior. OBJETIVO: Avaliar em quais pacientes portadores de surdez pós-lingual o implante coclear traz benefício auditivo superior ao da prótese auditiva convencional. MATERIAIS E MÉTODOS: consulta a artigos científicos por busca no banco de dados SciELO, Cochrane, MEDLINE e LILACS-BIREME. Foram selecionadas publicações com força de evidência A ou B até a data da investigação, que comparassem aparelhos de amplificação sonora e implante coclear na população com surdez pós-lingual. Desenho do Estudo: revisão sistemática. RESULTADOS: Entre os 2169 artigos consultados, 11 trabalhos se mostram pertinentes ao tema e apresentaram força de evidência B. Seis estudos são do tipo coorte prospectivo, quatro são estudos transversais e um ensaio clinico. CONCLUSÃO: A avaliação dos benefícios obtidos por portadores de surdez pós-lingual reabilitados com o uso de implante coclear mostra que este dispositivo é efetivo e apresenta melhores resultados quando comparado aos aparelhos de amplificação sonora individual.
Resumo:
INTRODUÇÃO: O aperfeiçoamento no tratamento inicial do paciente queimado, por meio da reposição volêmica e, principalmente, com excisão e enxertia precoce das lesões, resultou em profundo impacto na evolução dos indivíduos queimados, ocorrendo aumento da taxa de sobrevida. Com a maior sobrevida desses pacientes surgiu um novo desafio para a cirurgia reparadora, o tratamento das sequelas de queimaduras, principalmente compostas pelas contraturas. O objetivo deste estudo é demonstrar o uso da matriz dérmica artificial associado a terapia por pressão negativa no tratamento de sequelas de queimaduras. MÉTODO: Foram selecionados 10 pacientes com contratura por queimadura. Os pacientes selecionados foram submetidos a liberação da contratura cicatricial e colocação de matriz dérmica artificial (Integra®), conforme técnica padrão, e curativo por pressão negativa para cobertura. A cada 5 dias, foram realizadas trocas do curativo até completar período de 3 semanas a 4 semanas. Após esse período, o leito foi submetido a enxertia de pele. Os pacientes foram questionados, no pré e pós-operatório, quanto a sua satisfação com os aspectos estético e funcional da região abordada. RESULTADOS: Houve integração de cerca de 98% da matriz de regeneração dérmica na área em que a contratura foi ressecada. Também ocorreu integração de aproximadamente 85% dos enxertos utilizados. Todos os pacientes abordados referiram significativa melhora estética e, principalmente, funcional da região abordada. CONCLUSÕES: O uso da matriz de regeneração dérmica associado a terapia por pressão negativa promove maior taxa de sucesso na abordagem da contratura cicatricial, proporcionando melhor resultado tanto funcional como estético nos pacientes com sequelas graves de queimadura.