992 resultados para Cochlear implantation
Resumo:
AIMS: Patients with well-tolerated sustained monomorphic ventricular tachycardia (SMVT) and left ventricular ejection fraction (LVEF) over 30% may benefit from a primary strategy of VT ablation without immediate need for a 'back-up' implantable cardioverter-defibrillator (ICD). METHODS AND RESULTS: One hundred and sixty-six patients with structural heart disease (SHD), LVEF over 30%, and well-tolerated SMVT (no syncope) underwent primary radiofrequency ablation without ICD implantation at eight European centres. There were 139 men (84%) with mean age 62 ± 15 years and mean LVEF of 50 ± 10%. Fifty-five percent had ischaemic heart disease, 19% non-ischaemic cardiomyopathy, and 12% arrhythmogenic right ventricular cardiomyopathy. Three hundred seventy-eight similar patients were implanted with an ICD during the same period and serve as a control group. All-cause mortality was 12% (20 patients) over a mean follow-up of 32 ± 27 months. Eight patients (40%) died from non-cardiovascular causes, 8 (40%) died from non-arrhythmic cardiovascular causes, and 4 (20%) died suddenly (SD) (2.4% of the population). All-cause mortality in the control group was 12%. Twenty-seven patients (16%) had a non-fatal recurrence at a median time of 5 months, while 20 patients (12%) required an ICD, of whom 4 died (20%). CONCLUSION: Patients with well-tolerated SMVT, SHD, and LVEF > 30% undergoing primary VT ablation without a back-up ICD had a very low rate of arrhythmic death and recurrences were generally non-fatal. These data would support a randomized clinical trial comparing this approach with others incorporating implantation of an ICD as a primary strategy.
Resumo:
Rapport de synthèse: Enjeux de la recherche : La pneumonie communautaire chez l'enfant est un problème de santé publique considérable. Elle est responsable de 2 millions de mort par année, 70% survenant dans les pays en voie de développement. Sous nos latitudes son incidence est de 40/1000 enfants par année, ce qui représente une morbidité importante. Deux difficultés surviennent lorsqu'on cherche à diagnostiquer une pneumonie. La première est de distinguer une pneumonie bactérienne d'une virale, particulièrement chez les petits enfants où les infections virales des voies respiratoires inférieures sont fréquentes. L'OMS a définit la pneumonie selon des critères exclusivement cliniques et une étude effectuée à Lausanne en 2000 a montré que ces critères peuvent être utilisés dans nos contrées. La seconde difficulté est de définir l'agent causal de la pneumonie, ceci pour plusieurs raisons : L'aspiration endotrachéale, seul examen fiable, ne peut être obtenue de routine chez l'enfant vu son caractère invasif, la culture des secrétions nasopharyngées reflète la flore physiologique de la sphère ORL et une bactériémie n'est présente que dans moins de 10% des pneumonies. L'étiologie de la pneumonie reste souvent inconnue, et de ce fait plusieurs enfants reçoivent des antibiotiques pour une infection non bactérienne ce qui contribue au développement de résistances. L'objectif de cette étude était d'effectuer une recherche extensive de l'agent causal de la pneumonie et de déterminer quels facteurs pourraient aider le clinicien à différencier une pneumonie virale de bactérienne, en corrélant l'étiologie avec la sévérité clinique et les marqueurs de l'inflammation. Contexte de la recherche : II s'agissait d'une étude prospective, multicentrique, incluant les enfants âgés de 2 mois à 5 ans hospitalisés pour une pneumonie, selon les critères de l'OMS, dans le service de pédiatrie de Lausanne et Genève entre mars 2003 et Décembre 2005, avant l'implantation de la vaccination antipneumococcique de routine. Chaque enfant, en plus des examens usuels, bénéficiait d'une recherche étiologique extensive : Culture virale et bactérienne, PCR (Mycoplasma Pneumoniae, Chlamydia Pneumoniae, Virus Influenza A et B, RSV A et B, Rhinovirus, Parainfluenza 1-3, enterovirus, human metapneumovirus, coronavirus OC43, E229 ; et NL 63) et détection d'AG viraux dans les sécrétions nasopharyngées ; sérologies virales et bactériennes à l'entrée et 3 semaines après la sortie (AG Influenza A et B, Parainfluenza 1,2 et 3, RSV, Adenovirus, M.Pneumoniae et S.Pneumoniae). Conclusions : Un agent pathogène a été découvert chez 86% des 99 patients retenus confirmant le fait que plus la recherche étiologique est étendue plus le pourcentage d'agent causal trouvé est élevé. Une infection bactérienne a été découverte chez 53% des patients dont 45% avaient une infection à S. Pneumoniae confirmant l'importance d'une vaccination antipneumococcique de routine. La déshydratation et les marqueurs de l'inflammation tels que la C-Reactive Protein et la Procalcitonine étaient significativement plus élevés dans les pneumonies bactériennes. Aucune corrélation n'a été trouvée entre le degré de sévérité de la pneumonie et l'étiologie. L'étude a confirmé la haute prévalence d'infections virales (67%) et de co-infection (33%) dans la pneumonie de l'enfant sans que l'on connaisse le rôle réel du virus dans la pathogenèse de la pneumonie. Perspectives : d'autres études à la suite de celle-ci devraient être effectuées en incluant les patients ambulatoires afin de déterminer, avec un collectif plus large de patient, une éventuelle corrélation entre sévérité clinique et étiologie. Abstract : Community-acquired pneumonia (CAP) is a major cause of death in developing countries and of morbidity in developed countries. The objective of the study was to define the causative agents among children hospitalized for CAP defined by WHO guidelines and to correlate etiology with clinical severity and surrogate markers. Investigations included an extensive etiological workup. A potential causative agent was detected in 86% of the 99 enrolled patients, with evidence of bacterial (53%), viral (67%), and mixed (33%) infections. Streptococcus pneumoniae was accounted for in 46% of CAP. Dehydration was the only clinical sign associated with bacterial pneumonia. CRP and PCT were significantly higher in bacterial infections. Increasing the number of diagnostic tests identifies potential causes of CAP in up to 86% of children, indicating a high prevalence of viruses and frequent co-infections. The high proportion of pneumococcal infections re-emphasizes the importance of pneumococcal immunization.
Resumo:
Les monuments des jeux visibles dans toutes les provinces de l'Empire romain impressionnent touj us le visiteur. Sur la rive sud de la Méditerranée, honnis les sites de la Tunisie comme Carthage on Dougga facilement accessibles au public, les villes romaines d'Algérie on du Maroc sont souvent moïas bien connues.Dans le cadre de notre thèse de doctorat, nous avons étudié chaque édifice de spectacle (théâtre, amphithéâtre, cirque et stade) connu dans les Manrétanïes, ainsi que les spectacles et les cérémonies qui s'y déroulaient. L'implication des jeux dans l'adoption des moeurs romaines par la population était essentielle. Noos avons aussi recensé toutes les inscriptions et les objets (lampes à huile, statuettes, mosaïques) liés aux divertissements retrouvés dans ces provinces. La majeure partie de notre travail a consisté en une analyse des données publiées sur les monuments et les spectacles romains dans les Manrétanies. Nous les avons mises en regard de nos recherches sur le terrain et nous avons proposé de nouvelles interprétations lorsque cela était possible.Nous avons choisi de limiter notre travail aux Maurétanies romaines, car il n'existe aucune étude d'ensemble concernant les spectacles pour ces provinces. Elles formaient une entité particulière, comme royaume maurétanien avant la colonisation romaine, puis réunies à plusieurs reprises sous l'autorité d'un seul gouverneur sous l'Empire. Se concentrer sur un territoire permet de mieux saisir dans sa totalité le phénomène des spectacles et surtout les particularités architecturales. De plus, les Mauiétanies césarienne et tingitane posent souvent un problème d'intégration à l'Empire. L'implantation sur ces territoires s'est peu développée en profondeur, les légions protégeant une longue bande de terre située entre le limes et la Méditerranée qu'il n'était pas toujours simple de contrôler. Cependant les cités pré-romaines ont largement adopté les us et coutumes du nouveau pouvoir. Les raines, l'épigraphie et les fouilles archéologiques ne laissent aucun doute. Les éléments liés au divertissements et (dus particulièrement aux spectacles symbolisent le rayonnement culturel romain.À la fin de cette étude, nous avons accordé une place particulière aux monuments des jeux d'Afrique pour comparer et mieux comprendre les spécificités des édifices mauiétaniens à l'échelle de ce continent. La réflexion a été poursuivie à l'échelle de l'Empire romain, certaines caractéristiques mauritaniennes se retrouvant à des milliers de kilomètres. Nous avons essayé d'appréhender quelles relations les Maurétanies entretenaient avec le reste de l'Empire par le biais des spectacles et comment ces jeux ont fini par disparaître du territoire maurétanien.Cet ouvrage est divisé en deux parties : un volume de texte et un volume d'annexes. Dans le volume de texte, le premier chapitre est l'introduction générale. Nous détaillons les raisons de notre étude, les problématiques de cette recherche et les méthodes de travail utilisées. Le chapitre deux présente les cadres géographique, historique et sociologique. Le chapitre trois propose un lexique architectural savant à décrire chaque partie des monuments. Π retrace aussi l'origine et l'évolution des jeux romains et présente la répartition du public ainsi que le prix des bâtiments et des spectacles. Le répertoire des sites et des monuments des jeux maurétaniens constitue le chapitre quatre. 11 est subdivisé par provinces (Maurétanie césarienne, Maurétanie sit îenne et Maurétanie tîngitane), puisque la construction des monuments est liée à l'histoire provinciale. Les mosaïques et les objets reprenant les thèmes ludiques sont présentés selon loir lieu de découverte. Dans le chapitre dnq, nous étudions l'évolution historique et fonctionnelle des édifices de spectacle. Nous essayons de comprendre quels sont leurs sources ou leurs modèles architecturaux et comment ils ont influencé les populations locales. À la suite de la conclusion générale nous avons placé la liste des abréviations et la bibliographie.Au début du volume d'annexes se trouvent plusieurs catalogues : ceux des chapiteaux du théâtre et du cirque de Caesarea et ceux des lampes romaines à thèmes ludiques d'Algérie et du Maroc. Ensuite nous avons placé la restitution de plusieurs inscriptions, toutes les figures mentionnées dans le texte du premier volume, puis les listes des tableaux et des figures.
Resumo:
Aquest projecte estudia la implantació d’un sistema de posicionament a l’interior d’un edifici que compti amb una xarxa WiMAX. Per començar, s’analitzaran les característiques principals d’aquesta tecnología, la configuració de la xarxa amb la que treballarem i s’explicaran els mètodes de posicionament existents avui en dia. Més endavant s’estudiaran els aspectes més importants de la nostra aplicació: l’escenari, l’estimació de la distancia i l’estimació de la posició. Finalment, després d’analitzar els resultats de diverses mesures, es dissenyaran tres mètodes pel càlcul de la posició i s’aplicarà el nostre procediment en més de 15 escenaris de posicionament diferents, amb l’objectiu de comparar els resultats i definir quin dels mètodes aconsegueix un posicionament més precís.
Resumo:
Treatment of retinal detachment frequently uses biocompatible materials to obtain scleral buckling. These materials are not devoid of consequences on surrounding tissues. In 3 eyes enucleated for failure of surgical treatment using scleral buckling materials, the changes prompted by episcleral implants could be observed. The sclera underwent both an inversion of its curvature and a reduction of its thickness under the material, as well as an encapsulation of the material was observed. While a silicone sponge was used in part to encircle one of these eyes, its capsular inner surface was regular and smooth. In contrast, hydrogel implants used in the three eyes showed a peripheral fragmentation prompting in two of them a typical foreign body giant cell granulomatous reaction. Changes in scleral curvature and scleral thinning were observed reflecting the consequences of the buckling procedure. The capsule formation occurred as it does for any nonabsorbable matérial implanted in tissues. Degradation and fragmentation of the hydrogel material suscitated a granuloma in response to fragments. These hydrogel specific changes should be recognized on microscopic examination of slides of either capsule or eyes previously in contact with this implanted material. They attested of the instability of hydrogel after implantation.
Resumo:
Exogenous administration of glucocorticoids is a widely used and efficient tool to investigate the effects of elevated concentrations of these hormones in field studies. Because the effects of corticosterone are dose and duration-dependent, the exact course of plasma corticosterone levels after exogenous administration needs to be known. We tested the performance of self-degradable corticosterone pellets (implanted under the skin) in elevating plasma corticosterone levels. We monitored baseline (sampled within 3min after capture) total corticosterone levels and investigated potential interactions with corticosteroid-binding-globulin (CBG) capacity and the endogenous corticosterone response to handling in Eurasian kestrel Falco tinnunculus and barn owl Tyto alba nestlings. Corticosterone pellets designed for a 7-day-release in rodents elevated circulating baseline total corticosterone during only 2-3 days compared to placebo-nestlings. Highest levels occurred 1-2days after implantation and levels decreased strongly thereafter. CBG capacity was also increased, resulting in a smaller, but still significant, increase in baseline free corticosterone levels. The release of endogenous corticosterone as a response to handling was strong in placebo-nestlings, but absent 2 and 8 days after corticosterone pellet implantation. This indicates a potential shut-down of the hypothalamo-pituitary-adrenal axis after the 2-3 days of elevated baseline corticosterone levels. 20 days after pellet implantation, the endogenous corticosterone response to handling of nestlings implanted with corticosterone pellets attained similar levels as in placebo-nestlings. Self-degradable pellets proved to be an efficient tool to artificially elevate circulating baseline corticosterone especially in field studies, requiring only one intervention. The resulting peak-like elevation of circulating corticosterone, the concomitant elevation of CBG capacity, and the absence of an endogenous corticosterone response to an acute stressor have to be taken into account.
Resumo:
STUDY OBJECTIVES: Hemispheric stroke in humans is associated with sleep-wake disturbances and sleep electroencephalogram (EEG) changes. The correlation between these changes and stroke extent remains unclear. In the absence of experimental data, we assessed sleep EEG changes after focal cerebral ischemia of different extensions in mice. DESIGN: Following electrode implantation and baseline sleep-wake EEG recordings, mice were submitted to sham surgery (control group), 30 minutes of intraluminal middle cerebral artery (MCA) occlusion (striatal stroke), or distal MCA electrocoagulation (cortical stroke). One and 12 days after stroke, sleep-wake EEG recordings were repeated. The EEG recorded from the healthy hemisphere was analyzed visually and automatically (fast Fourier analysis) according to established criteria. MEASUREMENTS AND RESULTS: Striatal stroke induced an increase in non-rapid eye movement (NREM) sleep and a reduction of rapid eye movement sleep. These changes were detectable both during the light and the dark phase at day 1 and persisted until day 12 after stroke. Cortical stroke induced a less-marked increase in NREM sleep, which was present only at day 1 and during the dark phase. In cortical stroke, the increase in NREM sleep was associated in the wake EEG power spectra, with an increase in the theta and a reduction in the beta activity. CONCLUSION: Cortical and striatal stroke lead to different sleep-wake EEG changes in mice, which probably reflect variable effects on sleep-promoting and wakefulness-maintaining neuronal networks.
Resumo:
OBJECTIVES: Residual mitral regurgitation after valve repair worsens patients' clinical outcome. Postimplant adjustable mitral rings potentially address this issue, allowing the reshaping of the annulus on the beating heart under echocardiography control. We developed an original mitral ring allowing valve geometry remodelling after the implantation and designed an animal study to assess device effectiveness in correcting residual mitral regurgitation. METHODS: The device consists of two concentric rings: one internal and flexible, sutured to the mitral annulus and a second external and rigid. A third conic element slides between the two rings, modifying the shape of the flexible ring. This sliding element is remotely activated with a rotating tool. Animal model: in adult swine, under cardio pulmonary bypass and cardiac arrest, we shortened the primary chordae of P2 segment to reproduce Type III regurgitation and implanted the active ring. We used intracardiac ultrasound to assess mitral regurgitation and the efficacy of the active ring to correct it. RESULTS: Severe mitral regurgitation (3+ and 4+) was induced in eight animals, 54 ± 6 kg in weight. Vena contracta width decreased from 0.8 ± 0.2 to 0.1 cm; proximal isovelocity surface area radius decreased from 0.8 ± 0.2 to 0.1 cm and effective regurgitant orifice area decreased from 0.50 ± 0.1 to 0.1 ± 0.1 cm(2). Six animals had a reversal of systolic pulmonary flow that normalized following the activation of the device. All corrections were reversible. CONCLUSIONS: Postimplant adjustable mitral ring corrects severe mitral regurgitation through the reversible modification of the annulus geometry on the beating heart. It addresses the frequent and morbid issue of recurrent mitral valve regurgitation.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
Objectives: The AMS 800TM is the current artificial urinary sphincter (AUS) for incontinence due to intrinsic sphincter deficiency. Despite good clinical results, technical failures inherent to the hydraulic mechanism or urethral ischemic injury contribute to revisions up to 60%. We are developing an electronic AUS, called ARTUS to overcome the rigors of AMS. The objective of this study was to evaluate the technical efficacy and tissue tolerance of the ARTUS system in an animal model.Methods: The ARTUS is composed by three parts: the contractile unit, a series of rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor. In the first phase a three-rings device was used while in the second phase a two-rings ARTUS was used. The device was implanted in 14 sheep divided in two groups of six and eight animals for study purpose. The first group aimed at bladder leak point pressure (BLPP) measurement and validation of the animal model; the second group aimed at verifying mid-term tissue tolerance by explants at twelve weeks. General animal tolerance was also evaluated.Results: The ARTUS system implantation was uneventful. When the system was activated, the BLPP was measured at 1.038±0.044 bar (mean±SD). Urethral tissue analysis did not show significant morphological changes. No infection and no sign of discomfort were noted in animals at 12 weeks.Conclusions: The ARTUS proved to be effective in continence achievement in this study. Histological results support our idea that a sequential alternative mode can avoid urethral atrophy and ischemia. Further technical developments are needed to verify long-term outcome and permit human use.
Resumo:
BACKGROUND: Pulse wave velocity (PWV), an index of arterial wall stiffness, is modulated by blood pressure (BP). Whether heart rate (HR) is also a modulator of PWV is controversial. Recent research involving mainly patients with high aortic PWV have found either no change or a positive correlation between the two. Given that PWV is increasingly being measured in cardiovascular studies, the relationship between HR and PWV should be known in patients with preserved arterial wall elasticity. OBJECTIVE: The aim of this study was to evaluate the importance of HR as a determinant of the variability in PWV in patients with a low degree of atherosclerosis. DESIGN AND METHODS: Fourteen patients (five female, nine male; aged 68 +/- 8 years) were evaluated post pacemaker implantation due to sick sinus or carotid hypersensitivity syndromes. Carotid-femoral PWV was measured at rest and during atrial pacing at 80, 90 and 100 bpm (paced HR). Arterial femoral blood flow (AFBF) was measured by echodoppler. RESULTS: PWV increased from 6.2 +/- 1.5 m/s (mean +/- SD) during resting sinus rhythm (HR 62 +/- 8 bpm; mean +/- SD) to 6.8 +/- 1.0, 7.0 +/- 0.9, and 7.6 +/- 1.1 m/s at pacing rates of 80, 90 and 100 bpm, respectively (P < 0.0001). Systolic (SBP) and mean blood pressure (MBP) remained constant at all HR levels, whereas AFBF increased in a linear fashion. CONCLUSIONS: These results demonstrate that even in patients with a low degree of atherosclerosis, HR is a potential modulator of carotid-femoral PWV.
Resumo:
An overview is presented of the results obtained with biodegradable sustained release devices (SRDs) containing a mixture of polymers and either isometamidium (ISMM) or ethidium. Under controlled laboratory conditions (monthly challenge with tsetse flies infected with Trypanosoma congolense) the protection period in SRD treated cattle could be extended by a factor 2.8 (for ethidium) up to 4.2 (for ISMM) as compared to animals treated intramuscularly with the same drugs. Using a competitive drug ELISA ISMM concentrations were detected up to 330 days after the implantation of the SRDs, whereas after i.m. injection the drug was no longer present three to four months post treatment. Two field trials carried out in Mali under heavy tsetse challenge showed that the cumulative infection rate was significantly lower in the ISMM-SRD implanted cattle than in those which received ISMM intramuscularly. Using ethidium SRD, however, contradictory results were obtained in field trials in Zambia and in Mali. The potential advantages and inconvenients of the use of SRDs are discussed and suggestions are made in order to further improve the currently available devices.
Resumo:
Cataract surgery is often performed in patients suffering from associated pathologies. Our goal is to develop a biodegradable drug delivery system (DDS) combined with the artificial intraocular lens (IOL). DDS were manufactured using poly(D,L-lactide-co-glycolide), or PLGA, and were loaded with triamcinolone acetonide (TA). The loading capacity was approximately 1050 microg of TA per DDS. The higher the molecular weight of PLGA (34,000, 48,000 and 80,000Da), the slower was the release of TA in vitro. Cataract surgery was performed on the right eye of rabbits. IOL was inserted with (i) no DDS, (ii) unloaded DDS PLGA48000, (iii) one loaded DDS PLGA48000, (iv) two loaded DDS. The number of inflammatory cells and the protein concentration were measured in the aqueous humor (AH). Unloaded DDS showed good ocular biocompatibility. One DDS PLGA48000 loaded with TA significantly reduced postoperative ocular inflammation. Two loaded DDS PLGA48000 was even more effective in inhibiting such inflammation. On long-term observation (days 63 and 84), reduction of inflammation could be obtained by insertion of one DDS PLGA48000 and a second DDS PLGA80000. Therefore, our "all in one" system is very promising since it could replace oral treatment and reduce the number of intraocular injections
Resumo:
BACKGROUND AND OBJECTIVE: To compare the efficacy and longevity of nonpenetrating glaucoma surgery with and without the use of a nonabsorbable hydrophilic implant at the Oxford Eye Centre, Johannesburg, South Africa, and the Glaucoma Unit, Jules Gonin Ophthalmic Hospital, Lausanne, Switzerland. PATIENTS AND METHODS: In a nonrandomized, prospective study between March 1997 and December 2001, 48 eyes of 32 patients aged 18 to 86 years with primary open-angle glaucoma underwent nonpenetrating glaucoma surgery; 25 eyes with the implant and 23 eyes without it. Intraocular pressure (IOP) was recorded preoperatively and postoperatively at 1, 7, and 14 days, at 1, 3, and 6 months, and thereafter every 6 months. RESULTS: The mean preoperative IOP was 27.5 +/- 11.8 mm Hg (range, 20 to 64 mm Hg) in the implant group and 24.8 +/- 7.1 mm Hg (range, 16 to 38 mm Hg) in the control group. During the first 18 months of follow-up, both groups showed identical IOP progression and the mean IOP remained less than 14 mm Hg. After 2 years of follow-up, the IOP started to rise in the control group but remained stable in the implant group. After 30 months, the mean IOP was 12.4 +/- 2 mm Hg and the IOP decrease in percentage was 62% +/- 6% in the implant group (n = 13) versus 16.1 +/- 3 mm Hg and 34% +/- 13% in the control group (n = 15) (mean IOP, P = .0022; mean IOP decrease in percentage, P = .01). CONCLUSIONS: During the first 18 months, there was no difference in the outcomes between the two groups. After 2 years of follow-up, the mean IOP was lower and the IOP decrease in percentage was greater in the implant group compared with the control group.