983 resultados para Cavity perturbation technique
Resumo:
Photoluminescence experiments have identified strain as the origin for polarization pinning in vertical cavity surface emitting lasers post-processed by focused ion beam etching. Theoretical models were applied to deduce the strain in devices. Post-annealing was used to optimize polarization pinning.
Resumo:
Multi-wavelength picosecond pulses are demonstrated using a single monolithically integrated Multi-wavelength Grating Cavity (MGC) laser. This is achieved on two WDM wavelength channels at a repetition rate of 7.63 GHz.
Resumo:
Quantum well intermixing is a key technique for photonic integration. The intermixing of InP/InGaAs/InGaAsP material involving the deposition of a layer of sputtered SiO2 on the semiconductor surface, followed by thermal annealing has allowed good control of the intermixing process and has been used to fabricate extended cavity lasers. This will be used for optimization of the performance of optical switches consisting of passive components, modulators and amplifiers.
Resumo:
A continuous Gaussian profile matched to the fundamental mode was etched onto the aperture of a vertical cavity surface emitting laser (VCSEL). Single Gaussian spot emission was achieved over the entire operating current range.
Resumo:
High-speed configuration results of a conventional 850 nm VCSEL that is modified to operate as an efficient avalanche detector as well as a laser are discussed. The measured laser-to-detector reconfiguration delay of 3.2 ns is longer than the 1.2 ns detector-to-detector reconfiguration delay.
Resumo:
A technique to measure wall flow variation in Diesel Particle Filters (DPFs) is described. In a recent paper, it was shown how the flow distribution in DPFs could be measured in a non-destructive manner. This involved measuring the progressive dilution of a tracer gas introduced at the "outlet" channel upstream end. In the present paper, a significant further improvement to this technique is described, in which only a single probe is required, rather than the two of the previous technique. The single, traversable, probe consists of a controllable flow sink, and slightly downstream, a tracer gas supply. By controlling the sink flow rate such that a very small concentration of tracer gas is aspirated into it, the total flow up to that location in the channel is determined. Typical results showing the axial variation in the wall flow for known wall blockage cases are presented. It is suggested that this technique could be used to interpret the soot loading in the filter channels in a non-intrusive way.
Resumo:
A novel integrated Multi-Wavelength Grating Cavity (MGC) laser has been used for multi-channel wavelength conversion at 2.488Gbits/s. Functions demonstrated include conversion to multiple wavelengths, WDM multiplexing and 1×4 space switching.
Resumo:
155Mb/s operation of an optical wireless link is achieved by using the spectral characteristics and angular emission spectra of a 7-element tracking array of 980nm RC-LEDs. Preliminary results show extension to 200 Mb/s/channel. © 2006 Optical Society of America.
Resumo:
A packaging technique suited to applying MEMS strain sensors realized on a silicon chip to a steel flat surface is described. The method is based on adhesive bonding of the silicon chip rear surface on steel using two types of glue normally used for standard piezoresistive strain sensors (Mbond200/ 600), using direct wire bonding of the chip to a Printed Circuit Board, also fixed on steel. In order to protect the sensor from the external environment, and to improve the MEMS performance, the silicon chip is encapsulated with a metal cap hermetically sealed-off under vacuum condition with a vacuum adhesive in which the bonding wires are also protected from possible damage. In order to evaluate the mechanical coupling of the silicon chip with the bar and thestress transfer extent to the silicon surface, commercial strain sensors have been applied on the chip glued on a steel bar in alaboratory setup able to generate strain by inflection, yielding a stress transfer around 70% from steel to silicon. © 2008 IEEE.
Resumo:
Here we present a novel signal processing technique for a square wave thermally-modulated carbon black/polymer composite chemoresistor. The technique consists of only two mathematical operations: summing the off-transient and on-transient conductance signals; and subtracting the steady-state conductance signal. A single carbon black/polyvinylpyrrolidone composite chemo -resistor was fabricated and used to demonstrate the validity of the technique. Classification of water, methanol and ethanol vapours was successfully performed using only the peak time of the resultant curves. Quantification of the different vapours was also possible using the height of the peaks, because it was linearly proportional to concentration. This technique does not require zero-gas calibration and thus is superior to previously reported methods. ©2009 IEEE.
Resumo:
Receptor-based detection of pathogens often suffers from non-specific interactions, and as most detection techniques cannot distinguish between affinities of interactions, false positive responses remain a plaguing reality. Here, we report an anharmonic acoustic based method of detection that addresses the inherent weakness of current ligand dependant assays. Spores of Bacillus subtilis (Bacillus anthracis simulant) were immobilized on a thickness-shear mode AT-cut quartz crystal functionalized with anti-spore antibody and the sensor was driven by a pure sinusoidal oscillation at increasing amplitude. Biomolecular interaction forces between the coupled spores and the accelerating surface caused a nonlinear modulation of the acoustic response of the crystal. In particular, the deviation in the third harmonic of the transduced electrical response versus oscillation amplitude of the sensor (signal) was found to be significant. Signals from the specifically-bound spores were clearly distinguishable in shape from those of the physisorbed streptavidin-coated polystyrene microbeads. The analytical model presented here enables estimation of the biomolecular interaction forces from the measured response. Thus, probing biomolecular interaction forces using the described technique can quantitatively detect pathogens and distinguish specific from non-specific interactions, with potential applicability to rapid point-of-care detection. This also serves as a potential tool for rapid force-spectroscopy, affinity-based biomolecular screening and mapping of molecular interaction networks. © 2011 Elsevier B.V.
Resumo:
Thirteen restriction endonucleases were used to investigate nucleotide sequence variation in the 18S rRNA DNA of 88 individuals from ten Sarcocystis taxa collected as cysts from their intermediate hosts, swine, cattle and water buffalo. A DNA sequence of
Resumo:
For bacterial sampling of raw unprocessed fish and frozen fishery products, spread plate method is preferable to pour plate method; incubation of plates at 30°C gives a higher count than incubation at 37°C. Analysis of variance of the data shows that sample variation between different types of fishes is highly significant whereas the variations between triplicate plates are not significant at 5 % level.
Resumo:
An improved technique for the preparation of fish sausage (Nemipterus japonicus) over the conventional method (90°degree C for 1 h) has been evolved by processing at a temperature of 115.6°degree C (4.5 kg) for 20 min. The overall quality characteristics of fish sausage, particularly its colour, texture and appearance remained unchanged and the product was in good condition up to 9 days at ambient temperature in contrast to the shelf life of 3 days by conventional method. The design of the equipment used for the processing of fish sausage and the method of operation are described. The keeping quality of the product from an organoleptic stand point was also studied