985 resultados para Brunauer-Emmett-Teller technique
Resumo:
This paper presents a new and efficient methodology for distribution network reconfiguration integrated with optimal power flow (OPF) based on a Benders decomposition approach. The objective minimizes power losses, balancing load among feeders and subject to constraints: capacity limit of branches, minimum and maximum power limits of substations or distributed generators, minimum deviation of bus voltages and radial optimal operation of networks. The Generalized Benders decomposition algorithm is applied to solve the problem. The formulation can be embedded under two stages; the first one is the Master problem and is formulated as a mixed integer non-linear programming problem. This stage determines the radial topology of the distribution network. The second stage is the Slave problem and is formulated as a non-linear programming problem. This stage is used to determine the feasibility of the Master problem solution by means of an OPF and provides information to formulate the linear Benders cuts that connect both problems. The model is programmed in GAMS. The effectiveness of the proposal is demonstrated through two examples extracted from the literature.
Resumo:
Dissertação de Mestrado, Ciências Biomédicas, 3 de Fevereiro de 2016, Universidade dos Açores.
Resumo:
A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.
Resumo:
OBJECTIVE: Skeletal Muscle Biopsy is a minor surgical procedure for the diagnosis of different neuromuscular pathological conditions and has recently gained popularity also in the research field of age-related muscular modifications and sarcopenia. Few studies focused on the application of mini-invasive muscular biopsy in both normal and pathological conditions. The aim of our study was to describe a mini invasive ultrasound-guided skeletal muscular biopsy technique in complete spinal cord injured (SCI) patients and healthy controls with a tri-axial end-cut needle. PATIENTS AND METHODS: Skeletal muscle biopsies were collected from 6 chronic SCI patients and 3 healthy controls vastus lateralis muscle with a tri-axial end cut needle (Biopince© - Angiotech). Muscle samples were stained for ATPase to determine fibers composition, moreover, gene expression of cyclooxygenase-1 (COX-1) and prostaglandin E2 receptor has been analyzed by Real Time RT-PCR. RESULTS: All the procedures were perfomed easily without failures and complications. Control tissue was macroscopically thicker than SCI one. Control specimen displayed an equal distribution of type I and type II fibers, while SCI sample displayed a prevalence of type II fibers SCI specimen displayed a significant reduction in COX-1 gene expression. This mini-invasive approach was easy, accurate and with low complication rate in performing skeletal muscle biopsy in both SCI patients and controls. CONCLUSIONS: This technique could be useful in conditions in which the overall quantity of specimen required is small like for molecular biology analysis. For histological diagnostic purposes and/or conditions in which the original tissue is already pathologically modified, this technique should be integrated with more invasive techniques.
Resumo:
The objective of this master’s thesis is to investigate the loss behavior of three-level ANPC inverter and compare it with conventional NPC inverter. The both inverters are controlled with mature space vector modulation strategy. In order to provide the comparison both accurate and detailed enough NPC and ANPC simulation models should be obtained. The similar control model of SVM is utilized for both NPC and ANPC inverter models. The principles of control algorithms, the structure and description of models are clarified. The power loss calculation model is based on practical calculation approaches with certain assumptions. The comparison between NPC and ANPC topologies is presented based on results obtained for each semiconductor device, their switching and conduction losses and efficiency of the inverters. Alternative switching states of ANPC topology allow distributing losses among the switches more evenly, than in NPC inverter. Obviously, the losses of a switching device depend on its position in the topology. Losses distribution among the components in ANPC topology allows reducing the stress on certain switches, thus losses are equally distributed among the semiconductors, however the efficiency of the inverters is the same. As a new contribution to earlier studies, the obtained models of SVM control, NPC and ANPC inverters have been built. Thus, this thesis can be used in further more complicated modelling of full-power converters for modern multi-megawatt wind energy conversion systems.
Resumo:
1931/07 (N38).
Resumo:
Référence bibliographique : Rol, 59323