999 resultados para Bioanalytical Methods
Resumo:
Preparative liquid chromatography is one of the most selective separation techniques in the fine chemical, pharmaceutical, and food industries. Several process concepts have been developed and applied for improving the performance of classical batch chromatography. The most powerful approaches include various single-column recycling schemes, counter-current and cross-current multi-column setups, and hybrid processes where chromatography is coupled with other unit operations such as crystallization, chemical reactor, and/or solvent removal unit. To fully utilize the potential of stand-alone and integrated chromatographic processes, efficient methods for selecting the best process alternative as well as optimal operating conditions are needed. In this thesis, a unified method is developed for analysis and design of the following singlecolumn fixed bed processes and corresponding cross-current schemes: (1) batch chromatography, (2) batch chromatography with an integrated solvent removal unit, (3) mixed-recycle steady state recycling chromatography (SSR), and (4) mixed-recycle steady state recycling chromatography with solvent removal from fresh feed, recycle fraction, or column feed (SSR–SR). The method is based on the equilibrium theory of chromatography with an assumption of negligible mass transfer resistance and axial dispersion. The design criteria are given in general, dimensionless form that is formally analogous to that applied widely in the so called triangle theory of counter-current multi-column chromatography. Analytical design equations are derived for binary systems that follow competitive Langmuir adsorption isotherm model. For this purpose, the existing analytic solution of the ideal model of chromatography for binary Langmuir mixtures is completed by deriving missing explicit equations for the height and location of the pure first component shock in the case of a small feed pulse. It is thus shown that the entire chromatographic cycle at the column outlet can be expressed in closed-form. The developed design method allows predicting the feasible range of operating parameters that lead to desired product purities. It can be applied for the calculation of first estimates of optimal operating conditions, the analysis of process robustness, and the early-stage evaluation of different process alternatives. The design method is utilized to analyse the possibility to enhance the performance of conventional SSR chromatography by integrating it with a solvent removal unit. It is shown that the amount of fresh feed processed during a chromatographic cycle and thus the productivity of SSR process can be improved by removing solvent. The maximum solvent removal capacity depends on the location of the solvent removal unit and the physical solvent removal constraints, such as solubility, viscosity, and/or osmotic pressure limits. Usually, the most flexible option is to remove solvent from the column feed. Applicability of the equilibrium design for real, non-ideal separation problems is evaluated by means of numerical simulations. Due to assumption of infinite column efficiency, the developed design method is most applicable for high performance systems where thermodynamic effects are predominant, while significant deviations are observed under highly non-ideal conditions. The findings based on the equilibrium theory are applied to develop a shortcut approach for the design of chromatographic separation processes under strongly non-ideal conditions with significant dispersive effects. The method is based on a simple procedure applied to a single conventional chromatogram. Applicability of the approach for the design of batch and counter-current simulated moving bed processes is evaluated with case studies. It is shown that the shortcut approach works the better the higher the column efficiency and the lower the purity constraints are.
Resumo:
IFN-gamma mRNA expression was evaluated in nonstimulated peripheral blood mononuclear cells (PBMC) of HIV-infected and seronegative individuals using quantitative competitive and semiquantitative RT-PCR and the sensitivity of these methods was compared. A significant correlation was found between quantitative competitive and semiquantitative RT-PCR in samples of both HIV-seronegative (P = 0.004) and HIV-infected individuals (P = 0.0004). PBMC from HIV-infected individuals presented a remarkable increase of IFN-gamma mRNA expression, as determined by both types of RT-PCR methods. Semiquantitative RT-PCR even without an internal standard is also acceptable for measuring cytokine mRNA expression, but less reliable if small amounts are quantified. Moreover, we found that increased IFN-gammamRNA expression is independent of CD4+ cell count in AIDS-free HIV-infected patients.
Resumo:
Results of subgroup analysis (SA) reported in randomized clinical trials (RCT) cannot be adequately interpreted without information about the methods used in the study design and the data analysis. Our aim was to show how often inaccurate or incomplete reports occur. First, we selected eight methodological aspects of SA on the basis of their importance to a reader in determining the confidence that should be placed in the author's conclusions regarding such analysis. Then, we reviewed the current practice of reporting these methodological aspects of SA in clinical trials in four leading journals, i.e., the New England Journal of Medicine, the Journal of the American Medical Association, the Lancet, and the American Journal of Public Health. Eight consecutive reports from each journal published after July 1, 1998 were included. Of the 32 trials surveyed, 17 (53%) had at least one SA. Overall, the proportion of RCT reporting a particular methodological aspect ranged from 23 to 94%. Information on whether the SA preceded/followed the analysis was reported in only 7 (41%) of the studies. Of the total possible number of items to be reported, NEJM, JAMA, Lancet and AJPH clearly mentioned 59, 67, 58 and 72%, respectively. We conclude that current reporting of SA in RCT is incomplete and inaccurate. The results of such SA may have harmful effects on treatment recommendations if accepted without judicious scrutiny. We recommend that editors improve the reporting of SA in RCT by giving authors a list of the important items to be reported.
Resumo:
We tested the correlation of the albumin-to-creatinine ratio (A/C) in an early-morning urine sample, measured with a commercial kit (DCA 2000®), with the conventional immunoturbidimetric determination in the laboratory and with overnight albumin excretion rate (reference method). Fifty-five type 1 diabetic adolescents had their first-morning urine collected on the 1st and 8th day of the period. Urinary albumin and creatinine were determined immediately using the DCA 2000® kit. Samples were also stored for laboratory analysis. To evaluate the correlation between early-morning urinary A/C ratio and overnight albumin excretion rate, 16 subjects had a timed overnight urine collection. A/C ratios determined with the DCA 2000® kit and by the laboratory method were 13.1 ± 20.5 and 20.4 ± 46.3 mg/g, respectively. A/C results by both methods proved to be strongly correlated (r = 0.98, P<0.001). DCA 2000®-determined A/C showed 50% sensitivity and 100% specificity when compared to the reference method. Spot urinary A/C of the subset of 16 subjects significantly correlated with their overnight albumin excretion rate (r = 0.98, P<0.001). Intraindividual variation ranged from 17 to 32% and from 9 to 63% for A/C and overnight albumin excretion rate, respectively. In conclusion, an early-morning specimen should be used instead of timed overnight urine and the A/C ratio is an accurate, reliable and easily determined parameter for the screening of diabetic nephropathy. Immediate measurement of the A/C ratio is feasible using the DCA 2000® kit. Intraindividual variability indicates the need for repeated determinations to confirm microalbuminuria and the diagnosis of incipient diabetic nephropathy.
Resumo:
Our aim was to compare the clinical features of panic disorder (PD) patients sensitive to hyperventilation or breath-holding methods of inducing panic attacks. Eighty-five PD patients were submitted to both a hyperventilation challenge test and a breath-holding test. They were asked to hyperventilate (30 breaths/min) for 4 min and a week later to hold their breath for as long as possible, four times with a 2-min interval. Anxiety scales were applied before and after the tests. We selected the patients who responded with a panic attack to just one of the tests, i.e., those who had a panic attack after hyperventilating (HPA, N = 24, 16 females, 8 males, mean age ± SD = 38.5 ± 12.7 years) and those who had a panic attack after breath holding (BHPA, N = 20, 11 females, 9 males, mean age ± SD = 42.1 ± 10.6 years). Both groups had similar (chi² = 1.28, d.f. = 1, P = 0.672) respiratory symptoms (fear of dying, chest/pain disconfort, shortness of breath, paresthesias, and feelings of choking) during a panic attack. The criteria of Briggs et al. [British Journal of Psychiatry, 1993; 163: 201-209] for respiratory PD subtype were fulfilled by 18 (75.0%) HPA patients and by 14 (70.0%) BHPA patients. The HPA group had a later onset of the disease compared to BHPA patients (37.9 ± 11.0 vs 21.3 ± 12.9 years old, Mann-Whitney, P < 0.001), and had a higher family prevalence of PD (70.8 vs 25.0%, chi² = 19.65, d.f. = 1, P = 0.041). Our data suggest that these two groups - HPA and BHPA patients - may be specific subtypes of PD.
Resumo:
In this research, the effectiveness of Naive Bayes and Gaussian Mixture Models classifiers on segmenting exudates in retinal images is studied and the results are evaluated with metrics commonly used in medical imaging. Also, a color variation analysis of retinal images is carried out to find how effectively can retinal images be segmented using only the color information of the pixels.
Resumo:
Virtual environments and real-time simulators (VERS) are becoming more and more important tools in research and development (R&D) process of non-road mobile machinery (NRMM). The virtual prototyping techniques enable faster and more cost-efficient development of machines compared to use of real life prototypes. High energy efficiency has become an important topic in the world of NRMM because of environmental and economic demands. The objective of this thesis is to develop VERS based methods for research and development of NRMM. A process using VERS for assessing effects of human operators on the life-cycle efficiency of NRMM was developed. Human in the loop simulations are ran using an underground mining loader to study the developed process. The simulations were ran in the virtual environment of the Laboratory of Intelligent Machines of Lappeenranta University of Technology. A physically adequate real-time simulation model of NRMM was shown to be reliable and cost effective in testing of hardware components by the means of hardware-in-the-loop (HIL) simulations. A control interface connecting integrated electro-hydraulic energy converter (IEHEC) with virtual simulation model of log crane was developed. IEHEC consists of a hydraulic pump-motor and an integrated electrical permanent magnet synchronous motorgenerator. The results show that state of the art real-time NRMM simulators are capable to solve factors related to energy consumption and productivity of the NRMM. A significant variation between the test drivers is found. The results show that VERS can be used for assessing human effects on the life-cycle efficiency of NRMM. HIL simulation responses compared to that achieved with conventional simulation method demonstrate the advances and drawbacks of various possible interfaces between the simulator and hardware part of the system under study. Novel ideas for arranging the interface are successfully tested and compared with the more traditional one. The proposed process for assessing the effects of operators on the life-cycle efficiency will be applied for wider group of operators in the future. Driving styles of the operators can be analysed statistically from sufficient large result data. The statistical analysis can find the most life-cycle efficient driving style for the specific environment and machinery. The proposed control interface for HIL simulation need to be further studied. The robustness and the adaptation of the interface in different situations must be verified. The future work will also include studying the suitability of the IEHEC for different working machines using the proposed HIL simulation method.
Resumo:
This thesis studies the possibility to use lean tools and methods in a quotation process which is carried out in an office environment. The aim of the study was to find out and test the relevant lean tools and methods which can help to balance and standardize the quotation process, and reduce the variance in quotation lead times and in quality. Seminal works, researches and guide books related to the topic were used as the basis for the theory development. Based on the literature review and the case company’s own lean experience, the applicable lean tools and methods were selected to be tested by a sales support team. Leveling production, by product categorization and value stream mapping, was a key method to be used to balance the quotation process. 5S method was started concurrently for standardizing the work. Results of the testing period showed that lean tools and methods are applicable in office process and selected tools and methods helped to balance and standardize the quotation process. Case company’s sales support team decided to implement new lean based quotation process model.
Resumo:
The experiences of several healthcare organizations were considered to distinguish the most frequently used lean tools, the success and failure factors, and the obstacles that may appear while implementing lean. As a result, two approaches to “go lean” were defined, and analyzed from the prospective of the applicability to healthcare processes. Industrialization of healthcare was studied, and the most promising digital technology tools to improve healthcare process were highlighted. Finally, the analysis of healthcare challenges and feasible ways to address them was conducted and presented as the main result of this work. The possible ways of implementation of the findings and limitations were described in the conclusion.
Resumo:
Nowadays the energy efficiency has become one of the most concerned topics. Compressors are the equipment, which is very common in industry. Moreover, they tend to operate during long cycles and therefore even small decrease in power consumption can significantly reduce electricity costs during the year. And therefore it is important to investigate ways of increasing the energy efficiency of the compressors. In the thesis rotary screw compressor alongside with different control approaches is described. Simulation models for various control types of rotary screw compressor are developed. Analysis of laboratory equipment is conducted and results are compared with simulation. Suggestions of the real laboratory equipment improvement are given.
Resumo:
Methods for reliable evaluation of spinal cord (SC) injury in rats at short periods (2 and 24 h) after lesion were tested to characterize the mechanisms implicated in primary SC damage. We measured the physiological changes occurring after several procedures for producing SC injury, with particular emphasis on sensorimotor functions. Segmental and suprasegmental reflexes were tested in 39 male Wistar rats weighing 250-300 g divided into three control groups that were subjected to a) anesthesia, b) dissection of soft prevertebral tissue, and c) laminectomy of the vertebral segments between T10 and L1. In the lesion group the SC was completely transected, hemisected or subjected to vertebral compression. All animals were evaluated 2 and 24 h after the experimental procedure by the hind limb motility index, Bohlman motor score, open-field, hot-plate, tail flick, and paw compression tests. The locomotion scale proved to be less sensitive than the sensorimotor tests. A reduction in exploratory movements was detected in the animals 24 h after the procedures. The hot-plate was the most sensitive test for detecting sensorimotor deficiencies following light, moderate or severe SC injury. The most sensitive and simplest test of reflex function was the hot-plate. The hemisection model promoted reproducible moderate SC injury which allowed us to quantify the resulting behavior and analyze the evolution of the lesion and its consequences during the first 24 h after injury. We conclude that hemisection permitted the quantitation of behavioral responses for evaluation of the development of deficits after lesions. Hind limb evaluation scores and spontaneous exploration events provided a sensitive index of immediate injury effects after SC lesion at 2 and 24 h. Taken together, locomotion scales, open-field, and hot-plate tests represent reproducible, quantitatively sensitive methods for detecting functional deficiencies within short periods of time, indicating their potential for the study of cellular mechanisms of primary injury and repair after traumatic SC injury.
Resumo:
Several methods are used to estimate anaerobic threshold (AT) during exercise. The aim of the present study was to compare AT obtained by a graphic visual method for the estimate of ventilatory and metabolic variables (gold standard), to a bi-segmental linear regression mathematical model of Hinkley's algorithm applied to heart rate (HR) and carbon dioxide output (VCO2) data. Thirteen young (24 ± 2.63 years old) and 16 postmenopausal (57 ± 4.79 years old) healthy and sedentary women were submitted to a continuous ergospirometric incremental test on an electromagnetic braking cycloergometer with 10 to 20 W/min increases until physical exhaustion. The ventilatory variables were recorded breath-to-breath and HR was obtained beat-to-beat over real time. Data were analyzed by the nonparametric Friedman test and Spearman correlation test with the level of significance set at 5%. Power output (W), HR (bpm), oxygen uptake (VO2; mL kg-1 min-1), VO2 (mL/min), VCO2 (mL/min), and minute ventilation (VE; L/min) data observed at the AT level were similar for both methods and groups studied (P > 0.05). The VO2 (mL kg-1 min-1) data showed significant correlation (P < 0.05) between the gold standard method and the mathematical model when applied to HR (r s = 0.75) and VCO2 (r s = 0.78) data for the subjects as a whole (N = 29). The proposed mathematical method for the detection of changes in response patterns of VCO2 and HR was adequate and promising for AT detection in young and middle-aged women, representing a semi-automatic, non-invasive and objective AT measurement.
Resumo:
Traditional methods for studying the magnetic shape memory (MSM) alloys Ni-Mn-Ga include subjecting the entire sample to a uniform magnetic field or completely actuating the sample mechanically. These methods have produced significant results in characterizing the MSM effect, the properties of Ni-Mn-Ga and have pioneered the development of applications from this material. Twin boundaries and their configuration within a Ni-Mn-Ga sample are a key component in the magnetic shape memory effect. Applications that are developed require an understanding of twin boundary characteristics and, more importantly, the ability to predictably control them. Twins have such a critical role that the twinning stress of a Ni-Mn-Ga crystal is the defining characteristic that indicates its quality and significant research has been conducted to minimize this property. This dissertation reports a decrease in the twinning stress, predictably controlling the twin configuration and characterizing the dynamics of twin boundaries. A reduction of the twinning stress is demonstrated by the discovery of Type II twins within Ni-Mn-Ga which have as little as 10% of the twinning stress of traditional Type I twins. Furthermore, new methods of actuating a Ni-Mn-Ga element using localized unidirectional or bidirectional magnetic fields were developed that can predictably control the twin configuration in a localized area of a Ni-Mn-Ga element. This method of controlling the local twin configuration was used in the characterization of twin boundary dynamics. Using a localized magnetic pulse, the velocity and acceleration of a single twin boundary were measured to be 82.5 m/s and 2.9 × 107 m/s2, and the time needed for the twin boundary to nucleate and begin moving was less than 2.8 μs. Using a bidirectional magnetic field from a diametrically magnetized cylindrical magnet, a highly reproducible and controllable local twin configuration was created in a Ni-Mn-Ga element which is the fundamental pumping mechanism in the MSM micropump that has been co-invented and extensively characterized by the author.
Resumo:
The aim of this thesis is to propose a novel control method for teleoperated electrohydraulic servo systems that implements a reliable haptic sense between the human and manipulator interaction, and an ideal position control between the manipulator and the task environment interaction. The proposed method has the characteristics of a universal technique independent of the actual control algorithm and it can be applied with other suitable control methods as a real-time control strategy. The motivation to develop this control method is the necessity for a reliable real-time controller for teleoperated electrohydraulic servo systems that provides highly accurate position control based on joystick inputs with haptic capabilities. The contribution of the research is that the proposed control method combines a directed random search method and a real-time simulation to develop an intelligent controller in which each generation of parameters is tested on-line by the real-time simulator before being applied to the real process. The controller was evaluated on a hydraulic position servo system. The simulator of the hydraulic system was built based on Markov chain Monte Carlo (MCMC) method. A Particle Swarm Optimization algorithm combined with the foraging behavior of E. coli bacteria was utilized as the directed random search engine. The control strategy allows the operator to be plugged into the work environment dynamically and kinetically. This helps to ensure the system has haptic sense with high stability, without abstracting away the dynamics of the hydraulic system. The new control algorithm provides asymptotically exact tracking of both, the position and the contact force. In addition, this research proposes a novel method for re-calibration of multi-axis force/torque sensors. The method makes several improvements to traditional methods. It can be used without dismantling the sensor from its application and it requires smaller number of standard loads for calibration. It is also more cost efficient and faster in comparison to traditional calibration methods. The proposed method was developed in response to re-calibration issues with the force sensors utilized in teleoperated systems. The new approach aimed to avoid dismantling of the sensors from their applications for applying calibration. A major complication with many manipulators is the difficulty accessing them when they operate inside a non-accessible environment; especially if those environments are harsh; such as in radioactive areas. The proposed technique is based on design of experiment methodology. It has been successfully applied to different force/torque sensors and this research presents experimental validation of use of the calibration method with one of the force sensors which method has been applied to.