952 resultados para Balances (Weighing instruments)
Resumo:
A measure of dimensional anxiety specifically designed for use in older people is urgently needed. Such a measure could be used in a variety of settings to screen for anxiety disorders and to measure response to treatment in older people with established anxiety disorders. We have developed a new instrument to measure generalized anxiety symptoms in older people, the Geriatric Anxiety Inventory (GAI). This new instrument uses plain language, minimises somatic items and has a dichotomous response scale. Although it is a self-report measure, it may readily be administered to frail and mildly cognitively impaired older people by nursing staff. The development and initial validation of the GAI will be described. The scale was administered to community samples as well as patients with anxiety, depression, and mild cognitive impairment. Reliability was high and validity sound when compared to a range of standard anxiety instruments, and the instrument was well-tolerated among these cohorts. Sensitivity, specificity and cut-off scores for community and impatient samples will be presented.
Resumo:
BA is the most important disease requiring liver transplantation in children. Common BDL in rats is a classic experimental model to study biliary obstruction. The response of the neonatal animal to BDL has yet to be completely understood and few reports have focused on the behavioral differences of the liver between neonatal and adult animals. Ninety newborn Wistar rats aged six days, weighing 8.0-13.9 g, and 90 adult Wistar rats weighing 199.7-357.0 g, were submitted to BDL. After surgery, they were randomly divided and killed on the 3rd, 5th, 7th, 14th, 21st and 28th day post-BDL. Hepatic biopsies were obtained and the following were measured: (i) semiquantification of the bile ductule proliferation and inflammatory infiltrate by HE stain, (ii) quanti. cation of portal and periportal fibrosis with the Sirius-red stain. Although the initial response of ductule proliferation and inflammatory infiltrate were less intense in the newborn animal, the portal and periportal fibrosis were higher when compared with adult animals (p < 0.0491). These findings may contribute to the understanding of the pathophysiology of BA.
Resumo:
Objective: To evaluate the prevalence and clinical associated factors of alcohol use disorders (AUD) comorbidity in a large clinical sample of patients with obsessive-compulsive disorder (OCD). Methods: A cross-sectional study including 630 DSM-IV OCD patients from seven Brazilian university services, comparing patients with and without AUD comorbidity. The instruments of assessment used were a demographic and clinical questionnaire including evaluation of suicidal thoughts and acts and psychiatric treatment, the Structured Clinical Interview for DSM-IV Axis I disorders (SCID-I), the Yale-Brown Obsessive-Compulsive Scale, the Dimensional Yale-Brown Obsessive-Compulsive Scale, the Brown Assessment of Beliefs Scale, the Beck Depression and Anxiety Inventories and the Clinical Global Impression Scale. Current or past alcohol and other psychoactive substances use, abuse and dependence were assessed using the SCID-I (section E) and corroborated by medical and familial history questionnaires. Results: Forty-seven patients (7.5%) presented AUD comorbidity. Compared to OCD patients without this comorbidity they were more likely to be men, to have received previous psychiatric treatment, to present: lifetime suicidal thoughts and attempts and to have higher scores in the hoarding dimension. They also presented higher comorbidity with generalized anxiety and somatization disorders, and compulsive sexual behavior. Substance use was related to the appearance of the first O.C. symptoms and symptom amelioration. Conclusions: Although uncommon among OCD treatment seeking samples, AUD comorbidity has specific clinical features, such as increased risk for suicidality, which deserve special attention from mental health professionals. Future studies focused on the development of specific interventions for these patients are warranted. (C) 2008 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Aim: A positive effect of liver transplantation on health-related quality of life (HRQOL) has been well documented in previous studies using generic instruments. Our aim was to re-evaluate different aspects of HRQOL before and after liver transplantation with a relatively new questionnaire the `liver disease quality of life` (LDQOL). Methods: The LDQOL and the Short Form 36 (SF-36) questionnaires were applied to ambulatory patients, either in the transplant list (n=65) or after 6 months to 5 years of liver transplant (n=61). The aetiology of cirrhosis, comorbidities, model for end-stage liver disease (MELD) Child-Pugh scores and recurrence of liver disease after liver transplantation were analysed using the Mann-Whitney and Kruskall-Wallis tests. Results: In patients awaiting liver transplantation, MELD scores >= 15 and Child-Pugh class C showed statistically significant worse HRQOL, using both the SF-36 and the LDQOL questionnaires. HRQOL in pretransplant patients was found to be significantly worse in those with cirrhosis owing to hepatitis C (n=30) when compared with other aetiologies (n=35) in 2/7 domains of the SF-36 and in 7/12 domains of the LDQOL. Significant deterioration of HRQOL after recurrence of hepatitis C post-transplant was detected with the LDQOL questionnaire although not demonstrated with the SF-36. The statistically significant differences were in the LDQOL domains: symptoms of liver disease, concentration, memory and health distress. Conclusions: The LDQOL, a specific instrument for measuring HRQOL, has shown a greater accuracy in relation to liver symptoms and could demonstrate, with better reliability, impairments before and after liver transplantation.
Resumo:
The technical reliability (i.e., interinstrument and interoperator reliability) of three SEAC-swept frequency bioimpedance monitors was assessed for both errors of measurement and associated analyses. In addition, intraoperator and intrainstrument variability was evaluated for repeat measures over a 4-hour period. The measured impedance values from a range of resistance-capacitance circuits were accurate to within 3% of theoretical values over a range of 50-800 ohms. Similarly, phase was measured over the range 1 degrees-19 degrees with a maximum deviation of 1.3 degrees from the theoretical value. The extrapolated impedance at zero frequency was equally well determined (+/-3%). However, the accuracy of the extrapolated value at infinite frequency was decreased, particularly at impedances below 50 ohms (approaching the lower limit of the measurement range of the instrument). The interinstrument/operator variation for whole body measurements were recorded on human volunteers with biases of less than +/-1% for measured impedance values and less than 3% for phase. The variation in the extrapolated values of impedance at zero and infinite frequencies included variations due to operator choice of the analysis parameters but was still less than +/-0.5%. (C) 1997 Wiley-Liss, Inc.
Resumo:
AVFs may be considered the best type of venous access for chronic hemodialysis in pediatric patients with more than 20 kg who are not likely to receive a kidney transplant or be transitioned to peritoneal dialysis within one yr. The aim of the study was to report the experience in the creation of AVFs in pediatric candidates for renal transplantation using microsurgical vascular techniques, with emphasis on the details of the surgical technique. Forty children underwent 50 fistula creations - 31 radial-cephalic, 11 brachial-cephalic, five brachial-basilic and three saphenous-femoral. The vein was anastomosed to the artery in an end-to-lateral fashion by using two separate 8/0 prolene running sutures. The overall patency rate was 76.0%:22 (70.9%) of the radial-cephalic fistulas, nine (81.8%) of the brachial-cephalic, five (100.0%) of the brachial-basilic and two (66.6%) of the saphenous-femoral. There was no significant difference in patency rates between the brachial-cephalic, brachial-basilic and radial-cephalic fistulas. The incidences of fistula patency were not different for patients weighing < 20 kg compared with patients weighing > 20 kg. AVF remains as a satisfactory method for providing hemodialysis in children. The utilization of microsurgical techniques with some technical refinements described herein permits the achievement of high fistula patency rates.
Resumo:
Introduction: Smoking is a serious worldwide public health problem. Animal models act as a bridge between laboratory and human studies. The models applied are difficult to reproduce because of the use of different types of inhalation chambers and mainly because of the lack of continuous monitoring of smoke concentration. Objective: To develop an inhalation chamber for rats (with only the nose exposed) in which the amount of carbon monoxide (CO) can be maintained and monitored constantly. Material and methods: Male Wistar rats weighing 250 g were exposed to 50 ppm CO produced by the smoke from a filter-free cigarette. The animals were submitted to a single 2-h exposure and then sacrificed at 0, 4, 24 and 48 h. The control group was left restrained inside the small perpendicular chambers, receiving only 5 L/min of compressed air. Results: The model was able to increase HbCO levels immediately after the end of exposure (p < 0.001). with a decrease being observed from 2 h onwards when compared to the levels of the control group. Plasma cotinine increased immediately after exposure, and showed still detectable levels at 2 and 4 h (p < 0.05). Conclusion: We conclude that the presented inhalation chamber system is able to maintain a controlled CO concentration in a model in which small animals are exposed to the inhalation of cigarette smoke, permitting well-controlled studies, as well as investigations involving other toxic gases and air pollutants. (C) 2008 SEPAR. Published by Elsevier Espana, S.L. All rights reserved.