996 resultados para Assessment device
Resumo:
Chemokines (chemoattractant cytokines) induce potent and selective chemotaxis of leukocyte subsets in vitro. Here, we review briefly the chemokines shown to induce eosinophil chemotaxis in vitro and describe a novel model for the study of the ability of chemokines to stimulate eosinophil migration in vivo. Eosinophils were purified from the blood of mice over-expressing the IL-5 gene and labelled with 111In. Only the C-C chemokines, eotaxin and MIP-1alpha, but not RANTES, MCP-1, MCP-3, MCP-4, MIP-1ß, KC and MIP-2, effectively induced the recruitment of 111In-eosinophils in mouse skin. We suggest that this mouse model will be useful in assessing the role of endogenously-generated chemokines in mediating eosinophil migration to sites of allergic inflammation in vivo.
Resumo:
During the past twenty years, various instruments have been developed for the assessment of substance use in adolescents, mainly in the United States. However, few of them have been adapted to, and validated in, French-speaking populations. Consequently, although increasing alcohol and drug use among teenagers has become a major concern, the various health and social programs developed in response to this specific problem have received little attention with regard to follow-up and outcome assessment. A standardized multidimensional assessment instrument adapted for adolescents is needed to assess the individual needs of adolescents and assign them to the most appropriate treatment setting, to provide a single measurement within and across health and social systems, and to conduct treatment outcome evaluations. Moreover, having an available instrument makes it possible to develop longitudinal and transcultural research studies. For this reason, a French version of the Adolescent Drug Abuse Diagnosis (ADAD) was developed and validated at the University Child and Adolescent Psychiatric Clinic in Lausanne, Switzerland. This article aims to discuss the methodological issues that we faced when using the ADAD instrument in a 4-year longitudinal study including adolescent substance users. Methodological aspects relating to the content and format of the instrument, the assessment administration and the statistical analyses are discussed.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
OBJECTIVE: The aim of this pilot study was to describe problems in functioning and associated rehabilitation needs in persons with spinal cord injury after the 2010 earthquake in Haiti by applying a newly developed tool based on the International Classification of Functioning, Disability and Health (ICF). DESIGN: Pilot study. SUBJECTS: Eighteen persons with spinal cord injury (11 women, 7 men) participated in the needs assessment. Eleven patients had complete lesions (American Spinal Injury Association Impairment Scale; AIS A), one patient had tetraplegia. METHODS: Data collection included information from the International Spinal Cord Injury Core Data Set and a newly developed needs assessment tool based on ICF Core Sets. This tool assesses the level of functioning, the corresponding rehabilitation need, and required health professional. Data were summarized using descriptive statistics. RESULTS: In body functions and body structures, patients showed typical problems following spinal cord injury. Nearly all patients showed limitations and restrictions in their activities and participation related to mobility, self-care and aspects of social integration. Several environmental factors presented barriers to these limitations and restrictions. However, the availability of products and social support were identified as facilitators. Rehabilitation needs were identified in nearly all aspects of functioning. To address these needs, a multidisciplinary approach would be needed. CONCLUSION: This ICF-based needs assessment provided useful information for rehabilitation planning in the context of natural disaster. Future studies are required to test and, if necessary, adapt the assessment.
Resumo:
BACKGROUND: In patients with malignant pleural mesothelioma undergoing a multimodality therapy, treatment toxicity may outweigh the benefit of progression-free survival. The subjective experience across different treatment phases is an important clinical outcome. This study compares a standard with an individual quality of life (QoL) measure used in a multi-center phase II trial. PATIENTS AND METHODS: Sixty-one patients with stage I-III technically operable pleural mesothelioma were treated with preoperative chemotherapy, followed by pleuropneumonectomy and subsequent radiotherapy. QoL was assessed at baseline, at day 1 of cycle 3, and 1, 3 and 6 months post-surgery by using the Rotterdam Symptom Checklist (RSCL) and the Schedule for the Evaluation of Quality of Life-Direct Weighting (SEIQoL-DW), a measure that is based on five individually nominated and weighted QoL-domains. RESULTS: Completion rates were 98% (RSCL) and 92% (SEIQoL) at baseline and 98%/89% at cycle 3, respectively. Of the operated patients (N=45) RSCL and SEIQoL were available from 86%/72%, 93%/74%, and 94%/76% at months 1, 3, and 6 post-surgery. Average assessment time for the SEIQoL was 24min compared to 8min needed for the RSCL. Median changes from baseline indicate that both RSCL QoL overall score and SEIQoL index remained stable during chemotherapy with a clinically significant deterioration (change>or=8 points) 1 month after surgery (median change of -66 and -14 for RSCL and SEIQoL, respectively). RSCL QoL overall scores improved thereafter, but remained beneath baseline level until 6 months after surgery. SEIQoL scores improved to baseline-level at month 3 after surgery, but worsened again at month 6. RSCL QoL overall score and SEIQoL index were moderately correlated at baseline (r=.30; p<or=.05) and at 6-month follow-up (r=.42; p<or=.05) but not at the other time points. CONCLUSION: The SEIQoL assessment seems to be feasible within a phase II clinical trial, but may require more effort from staff. More distinctive QoL changes in accordance with clinical changes were measured with the RSCL. Our findings suggest that the two measures are not interchangeable: the RSCL is to favor when mainly information related to the course of disease- and treatment is of interest.
Resumo:
Direct electrical stimulation of the colon offers a promising approach for the induction of propulsive colonic contractions by using an implantable device. The objective of this study was to assess the feasibility to induce colonic contractions using a commercially available battery-operated stimulator (maximum pulse width of 1 ms and maximum amplitude of 10 V). Three pairs of pacing electrodes were inserted into the cecal seromuscular layer of anesthetized pigs. During a first set of in vivo experiments conducted on six animals, a pacing protocol leading to cecum contractions was determined: stimulation bursts with 1 ms pulse width, 10 V amplitude (7-15 mA), 120 Hz frequency, and 30-s burst duration, repeated every 2-5 min. In a second testing phase, an evaluation of the pacing protocol was performed in four animals (120 stimulation bursts in total). By using the battery-operated stimulator, contractions of the cecum and movement of contents could be induced in 92% of all stimulations. A cecal shortening of about 30% and an average intraluminal pressure increase of 10.0 +/- 6.0 mmHg were observed.
Resumo:
PURPOSE: We report on the in vivo testing of a novel noninvasively adjustable glaucoma drainage device (AGDD), which features an adjustable outflow resistance, and assess the safety and efficiency of this implant. METHODS: Under general anesthesia, the AGDD was implanted on seven white New Zealand rabbits for a duration of 4 months under a scleral flap in a way analogous to the Ex-PRESS device and set in an operationally closed position. The IOP was measured on a regular basis on the operated and control eyes using a rebound tonometer. Once a month the AGDD was adjusted noninvasively from its fully closed to its fully open position and the resulting pressure drop was measured. The contralateral eye was not operated and served as control. After euthanization, the eyes were collected for histology evaluation. RESULTS: The mean preoperative IOP was 11.1 ± 2.4 mm Hg. The IOP was significantly lower for the operated eye (6.8 ± 2 mm Hg) compared to the nonoperated eye (13.1 ± 1.6 mm Hg) during the first 8 days after surgery. When opening the AGDD from its fully closed to fully open position, the IOP dropped significantly from 11.2 ± 2.9 to 4.8 ± 0.9 mm Hg (P < 0.05). CONCLUSIONS: Implanting the AGDD is a safe and uncomplicated surgical procedure. The fluidic resistance was noninvasively adjustable during the postoperative period with the AGDD between its fully closed and fully open positions.
Resumo:
This study compared adherence (persistence and execution) during pregnancy and postpartum in HIV-positive women having taken part in the adherence-enhancing program of the Community Pharmacy of the Department of Ambulatory Care and Community Medicine in Lausanne between 2004 and 2012. This interdisciplinary program combined electronic drug monitoring and semi-structured, repeated motivational interviews. This was a retrospective, observational study. Observation period spread over from first adherence visit after last menstruation until 6 months after childbirth. Medication-taking was recorded by electronic drug monitoring. Socio-demographic and delivery data were collected from Swiss HIV Cohort database. Adherence data, barriers and facilitators were collected from pharmacy database. Electronic data were reconciled with pill-count and interview notes in order to include reported pocket-doses. Execution was analyzed over 3-day periods by a mixed effect logistic model, separating time before and after childbirth. This model allowed us to estimate different time slopes for both periods and to show a sudden fall associated with childbirth. Twenty-five pregnant women were included. Median age was 29 (IQR: 26.5, 32.0), women were in majority black (n_17,68%) and took a cART combining protease and nucleoside reverse transcriptase inhibitors (n_24,96%). Eleven women (44%) were ART-naı¨ve at the beginning of pregnancy. Twenty women (80%) were included in the program because of pregnancy. Women were included at all stages of pregnancy. Six women (24%) stopped the program during pregnancy, 3 (12%) at delivery, 4 (16%) during postpartum and 12 (48%) stayed in program at the end of observation time. Median number of visits was 4 (3.0, 6.3) during pregnancy and 3 (0.8, 6.0) during postpartum. Execution was continuously high during pregnancy, low at beginning of postpartum and increased gradually during the 6 months of postpartum. Major barriers to adherence were medication adverse events and difficulties in daily routine. Facilitators were motivation for promoting child-health and social support. The dramatic drop and very slow increase in cART adherence during postpartum might result in viral rebound and drug resistance. Although much attention is devoted to pregnant women, interdisciplinary care should also be provided to women in the community during first trimester of postpartum to support them in sustaining cART adherence.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
Perioperative cardiac events occurring in patients undergoing non-cardiac surgery are a common cause of morbidity and mortality. Current guidelines recommend an individualized approach to preoperative cardiac risk stratification prior to non-cardiac surgery, integrating risk factors both for the patient (active cardiac conditions, clinical risk factors, functional capacity) and for the planned surgery. Preoperative cardiac investigations are currently limited to high-risk patients in whom they may contribute to modify the perioperative management. A multidisciplinary approach to such patients, integrating the general practitioner, is recommended in order to define an individualized peri-operative strategy.