934 resultados para veins


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sepsis is commonly associated with brain dysfunction, but the underlying mechanisms remain unclear, although mitochondrial dysfunction and microvascular abnormalities have been implicated. We therefore assessed whether cerebral mitochondrial dysfunction during systemic endotoxemia in mice increased mitochondrial sensitivity to a further bioenergetic insult (hyoxemia), and whether hypothermia could improve outcome. Mice (C57bl/6) were injected intraperitoneally with lipopolysaccharide (LPS) (5 mg/kg; n = 85) or saline (0.01 ml/g; n = 47). Six, 24 and 48 h later, we used confocal imaging in vivo to assess cerebral mitochondrial redox potential and cortical oxygenation in response to changes in inspired oxygen. The fraction of inspired oxygen (FiO2) at which the cortical redox potential changed was compared between groups. In a subset of animals, spontaneous hypothermia was maintained or controlled hypothermia induced during imaging. Decreasing FiO2 resulted in a more reduced cerebral redox state around veins, but preserved oxidation around arteries. This pattern appeared at a higher FiO2 in LPS-injected animals, suggesting an increased sensitivity of cortical mitochondria to hypoxemia. This increased sensitivity was accompanied by a decrease in cortical oxygenation, but was attenuated by hypothermia. These results suggest that systemic endotoxemia influences cortical oxygenation and mitochondrial function, and that therapeutic hypothermia can be protective.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The establishment of radiofrequency catheter ablation techniques as the mainstay in the treatment of tachycardia has renewed new interest in cardiac anatomy. The interventional arrhythmologist has drawn attention not only to the gross anatomic details of the heart but also to architectural and histological characteristics of various cardiac regions that are relevant to the development or recurrence of tachyarrhythmias and procedural related complications of catheter ablation. In this review, therefore, we discuss some anatomic landmarks commonly used in catheter ablations including the terminal crest, sinus node region, Koch’s triangle, cavotricuspid isthmus, Eustachian ridge and valve, pulmonary venous orifices, venoatrial junctions, and ventricular outflow tracts. We also discuss the anatomical features of important structures in the vicinity of the atria and pulmonary veins, such as the esophagus and phrenic nerves. This paper provides basic anatomic information to improve understanding of the mapping and ablative procedures for cardiac interventional electrophysiologists.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The AntiPhospholipid Syndrome (APS) is an acquired autoimmune disorder induced by high levels of antiphospholipid antibodies that cause arterial and veins thrombosis, as well as pregnancy-related complications and morbidity, as clinical manifestations. This autoimmune hypercoagulable state, usually known as Hughes syndrome, has severe consequences for the patients, being one of the main causes of thrombotic disorders and death. Therefore, it is required to be preventive; being aware of how probable is to have that kind of syndrome. Despite the updated of antiphospholipid syndrome classification, the diagnosis remains difficult to establish. Additional research on clinically relevant antibodies and standardization of their quantification are required in order to improve the antiphospholipid syndrome risk assessment. Thus, this work will focus on the development of a diagnosis decision support system in terms of a formal agenda built on a Logic Programming approach to knowledge representation and reasoning, complemented with a computational framework based on Artificial Neural Networks. The proposed model allows for improving the diagnosis, classifying properly the patients that really presented this pathology (sensitivity higher than 85%), as well as classifying the absence of APS (specificity close to 95%).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduzione: L’intervento di Fontan comporta un aumento istantaneo della pressione venosa centrale che causa, nel medio-lungo termine, una forma di epatopatia specifica detta FALD. Il monitoraggio della FALD è complesso ma potrebbe consentire di bloccarne o rallentarne l’insorgenza. Lo studio ha valutato l’efficacia delle modalità di monitoraggio non invasivo. Materiale e metodi: Sei pazienti (età media 24 anni) operati presso l’IRCCS Azienda Ospedaliero Universitaria di Bologna sono stati sottoposti a RMN 4D-Flow e ad Ecodoppler epatico. Sono stati raccolti i dati anagrafici, morfologici, anamnestici e i markers sierologici per il calcolo degli scores MELD-XI, APRI, FIB4, i valori di Shear Stress assiale e circonferenziale e gli indici di pulsatilità e resistenza delle arterie epatica e renale. Risultati: Il tempo trascorso tra la Fontan e lo studio è stato di 17,8 anni. Età media alla Fontan 6,8 anni. Tutti i pazienti avevano un quadro compatibile con epatopatia. I markers sierologici e gli scores MELD-XI,APRI e FIB4 si sono dimostrati di scarsa utilità. All’ecografia tutti i pazienti avevano ecostruttura irregolare, splenomegalia e valori elevati di pulsatilità e resistenza dell’arteria epatica e splenica. La rigidità epatica media è stata di 12,4 Kpa. Alla RMN 4DF lo Shear stress assiale è stato massimo a livello del condotto (0,16 Pa) e minimo a livello delle vene sovra epatiche (0,05 Pa). Lo Shear Stress si è mostrato massimo nei pazienti con emodinamica sfavorevole e peggior quadro ecografico addominale, evidenziando aree di inefficienza energetica. Conclusioni: La combinazione delle diagnostiche di imaging non invasive potrebbe rivelarsi adeguata per il monitoraggio della FALD. In particolare, la RMN 4D Flow potrebbe rivelare aree di inefficienza energetica predisponenti alla FALD. Questo potrebbe indirizzare in modo specifico la terapia dei pazienti operati o addirittura indurre la modifica del disegno della Fontan verso forme più efficienti.