978 resultados para válvula nasal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The congenital facial clefts are characterized by incomplete formation of the structures that separate the oral and nasal cavity. It is known that several environmental and genetic factors are involved in its development, among these, polymorphisms associated with folic acid metabolism have been investigated. In this sense, the objective was to observe the frequency of polymorphisms C677T and A1298C methylenetetrahydrofolate reductase gene (MTHFR), methionine synthase A2756G of (MTR), A66G of methionine synthase reductase (MTRR) A80G and the reduced folate carrier (RFC1) in patients with non-syndromic oral clefts, trying to match them with their development. Methods: We studied 140 patients with non-syndromic oral clefts and their mothers and 175 control subjects with their mothers, who underwent a questionnaire to obtain family information. Were collecting blood for DNA extraction from patients and their mothers to identify the genotypes of both by PCRRFLP, in addition to carrying out the determination of glucose, AST, ALT and serum creatinine, folic acid and vitamin B12 Serum and plasma homocysteine, and the hemogram. Results: Most patients have cleft lip and palate (55.8%), followed by isolated cleft palate (24.2%) and cleft lip (20%). Regarding gender, 62% of patients were male and 48% female and, after subdivision of the type of screwdriver according to sex was found a prevalence of males in the cracks of the type lip and palate (69 %) and lip (69.2%) and in the case of cleft palate was a female predominance (59%). The average concentration of serum folate in the group of mothers of cleft patients was significantly lower (13.8 ± 2.4 ng / mL) compared with the group of mothers of control subjects (18.8 ± 3.4 ng / mL) This was also observed for the group of cleft children as compared to controls, the dosage of folic acid had a significant difference with values of 15.6 ± 0.6 (ng / mL) and 17.9 ± 0.6 (ng / mL), respectively. For the biochemical measurements of glucose, AST, ALT and creatinine were not statistically different, nor was observed for haematological parameters performed. In assessing the frequency of polymorphisms C677T and A1298C MTHFR, A2756G MTR, MTRR A66G and A80G of the RFC1 there was no statistically significant difference in genotype distribution between cases and controls both for mothers and in the cleft. Conclusion: Although not observed association of polymorphisms with the development of cracks, the decrease in serum folate in the group of cleft patients and their mothers may reflect a disturbance in the metabolism of this metabolite, necessitating further studies such as studies methylation and expression to further elucidate the involvement of folate in the development of oral clefts

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O experimento foi conduzido com o objetivo de avaliar a dinâmica fermentativa e microbiológica de silagens de capins tropicais acrescidas de polpa cítrica. Os capins tanzânia (Panicum maximum cv. Tanzânia) e marandu (Brachiaria brizantha (Hochst ex. A. Rich) Stapf cv. Marandu) foram colhidos aos 64 e 49 dias de rebrota, respectivamente, e ensilados com 0, 5 ou 10% de polpa cítrica peletizada (PCP), em relação à matéria verde, durante 1, 4, 7, 14, 21, 28 e 56 dias. Foram utilizados silos experimentais de PVC adaptados com válvula do tipo Bunsen para eliminação dos gases. A forragem foi compactada visando obter densidade de 550 kg/m³. O delineamento utilizado foi o inteiramente ao acaso com três repetições, em esquema de parcelas subdivididas. A inclusão de PCP aumentou os teores de MS e diminuiu o pH das silagens. A adição de PCP influenciou os teores de N-NH3 (N total), uma vez que, nas silagens sem PCP, os teores N-NH3 foram significativamente elevados, o que as caracteriza como de qualidade duvidosa. A adição de PCP aumentou a concentração molar dos ácidos acético e propiônico. A população de enterobactérias foi detectada somente no primeiro dia de fermentação nas silagens do capim-tanzânia e até o 18º dia nas do capim-marandu. Nas silagens avaliadas, a população de bactérias homofermentativas foi semelhante à das bactérias heterofermentativas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A doença degenerativa mixomatosa da válvula mitral (DDMVM) é uma cardiopatia de alta incidência na clínica médica de pequenos animais, acometendo mormente cães idosos e raças de pequeno porte. Desta forma, foi realizada uma investigação científica objetivando avaliar clinicamente a utilização dos fármacos maleato de enalapril e furosemida em cães com a referida enfermidade na classe funcional Ib da ICC, antes e após a terapêutica implantada. Para isso, utilizaram-se 16 cães portadores da valvulopatia supracitada, distribuídos em dois grupos; com o primeiro recebendo furosemida (n=8) e o segundo maleato de enalapril (n=8), durante 56 dias. Os cães foram avaliados em quatro momentos (T0, T14, T28 e T56 dias) quanto aos sinais clínicos e parâmetros hematológicos e bioquímico-séricos, que incluíram concentrações séricas da enzima conversora da angiotensina (ECA) e aldosterona, como também avaliações radiográficas, eletrocardiográficas, ecodopplercardiográficas e da pressão arterial. Os resultados quanto aos parâmetros clínicos, avaliações hematológicas e bioquímicas séricas não revelaram alterações significativas em ambos os grupos, mas reduções significativas nos valores de ECA e aldosterona no grupo que recebeu o maleato de enalapril foram identificadas. Ao exame radiográfico observou-se reduções nos valores de VHS e na variável onda Pms do eletrocardiograma em ambos os grupos, mas sem alterações nos valores da pressão arterial. Por sua vez, o ecodopplercardiograma evidenciou diminuição significativa das variáveis DIVEd/s nos grupos estudados e na FEC% nos cães que receberam somente enalapril. Portanto, a análise dos resultados encontrados indicou que a monoterapia fundamentada no maleato de enalapril apresentou melhor eficiência no controle do quadro clínico em pacientes da classe funcional Ib da ICC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os transtornos da pele e dos pelos são parte importante na prática clínica de pequenos animais. Numerosos fatores nutricionais afetam a homeostase, a qualidade e o aspecto da pelagem. As vitaminas do complexo B incluem compostos hidrossolúveis necessários como coenzimas em diversas funções celulares envolvidas no metabolismo energético e na síntese tecidual. A biotina, em especial, é necessária nas reações de carboxilação, participando da síntese de ácidos graxos, aminoácidos e purinas pelo tecido epitelial. Uma cadela com quadro de cistite recorrente e tumor venéreo transmissível foi tratada com antibioticoterapia prolongada e quimioterapia. Após alguns meses de tratamento, foram observadas lesões no plano nasal e nos coxins plantar e palmar, caracterizadas por hiperceratose, espessamento, fissuras, sangramento e inflamação. O paciente recebeu suplementação de 15mg de biotina por via oral (equivalente a 1,4mg kg-1 de peso corporal), uma vez por dia, durante 60 dias, havendo importante regressão das lesões. Sugere-se que, sob antibioticoterapia e doença, a síntese intestinal de biotina possa não ter sido suficiente, sendo necessária sua suplementação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Avaliou-se a cardiotoxicidade da doxorrubicina utilizando-se sete cães adultos, clinicamente normais, que receberam 30mg/m² de cloridrato de doxorrubicina (Adriblastina®) por via intravenosa, a cada 21 dias, durante 168 dias (grupo A), perfazendo dose cumulativa total de 240mg/m². em outros sete cães (grupo B) administraram-se 5ml de solução salina 0,9% estéril por via intravenosa, seguindo-se o esquema de aplicação proposto anteriormente. Os animais foram avaliados, periodicamente, por meio de exames ecocardiográficos em modo-M e bidimensional. Verificou-se aumento (P<0,01) no diâmetro e volume do ventrículo esquerdo, inicialmente em sístole e, posteriormente, em diástole, hipocinesia do septo interventricular e da parede livre do ventrículo esquerdo, reduções de aproximadamente 65% nas frações de encurtamento e de ejeção, além de aumento da separação do septo do ponto E do folheto anterior da válvula mitral nos animais do grupo A. As alterações cardíacas decorrentes do tratamento crônico com doxorrubicina foram semelhantes àquelas descritas em cães com cardiomiopatia dilatada, e os índices ecocardiográficos puderam ser utilizados no acompanhamento e na prevenção da cardiotoxicidade pelo quimioterápico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Uma vacina experimental inativada contra o herpesvírus bovino tipo 1 (BoHV-1) foi produzida com o objetivo de se avaliar a resposta imune humoral local e sistêmica contra o BoHV-1, em 12 novilhas soronegativas, após a vacinação e a revacinação. Os soros foram submetidos à prova de vírus-neutralização para quantificação do título de anticorpos neutralizantes e a um ELISA para detecção de IgG1 e IgG2. Os swabs nasais também foram submetidos ao ELISA para detecção de IgG1 e IgG2 na secreção nasal. Os resultados demonstraram que títulos de anticorpos neutralizantes foram induzidos após a revacinação, em níveis moderados a altos, permanecendo em níveis significativos no soro sanguíneo e na secreção nasal até o dia 114 pós-vacinação. O IgG2 foi o isótipo predominante na maior parte do período pós-vacinação, tanto na secreção nasal, como no compartimento sistêmico. A vacina experimental inativada contra o BoHV-1 estimulou níveis de anticorpos potencialmente protetores dos isótipos IgG1 e IgG2, tanto no compartimento sistêmico, como nas mucosas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Forragens com alta umidade e baixa concentração de carboidratos solúveis, como é o caso dos capins tropicais, podem conduzir a condições desfavoráveis para a produção de silagens de qualidade satisfatória. Esse estudo objetivou conhecer o perfil fermentativo e microbiológico de silagens de capim-Marandu [Brachiaria brizantha (Hochst ex. A. Rich) Stapf cv. Marandu], colhido com 58 dias de crescimento, aditivadas com polpa cítrica peletizada (PCP),. Foram utilizados silos experimentais de PVC adaptados com válvula do tipo Bunsen, tendo a silagem atingindo densidade de 900 kg m-3. Os tratamentos foram constituídos por três proporções de PCP (0, 50 e 100 g kg-1 em relação a matéria natural) e sete tempos de abertura após a ensilagem (1, 4, 7, 14, 21, 28 e 56 dias). A presença de PCP aumentou os teores de CHOs em 15 a 20%, reduziu o pH (5,3 para 4,2) e diminuiu as concentrações de N-NH3. Houve crescimento da população de enterobactérias somente durante o primeiro dia de fermentação (média 3 UFC g-1), pequeno desenvolvimento de clostrideos (média 0,5 UFC g-1) e dominância de bactérias homo em relação às heterofermentativas, para os três tratamentos estudados. A adição de polpa cítrica durante a ensilagem do capim-Marandu foi benéfica, podendo ser recomendada desde que haja benefício econômico na sua adoção.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work intends to analyze the behavior of the gas flow of plunger lift wells producing to well testing separators in offshore production platforms to aim a technical procedure to estimate the gas flow during the slug production period. The motivation for this work appeared from the expectation of some wells equipped with plunger lift method by PETROBRAS in Ubarana sea field located at Rio Grande do Norte State coast where the produced fluids measurement is made in well testing separators at the platform. The oil artificial lift method called plunger lift is used when the available energy of the reservoir is not high enough to overcome all the necessary load losses to lift the oil from the bottom of the well to the surface continuously. This method consists, basically, in one free piston acting as a mechanical interface between the formation gas and the produced liquids, greatly increasing the well s lifting efficiency. A pneumatic control valve is mounted at the flow line to control the cycles. When this valve opens, the plunger starts to move from the bottom to the surface of the well lifting all the oil and gas that are above it until to reach the well test separator where the fluids are measured. The well test separator is used to measure all the volumes produced by the well during a certain period of time called production test. In most cases, the separators are designed to measure stabilized flow, in other words, reasonably constant flow by the use of level and pressure electronic controllers (PLC) and by assumption of a steady pressure inside the separator. With plunger lift wells the liquid and gas flow at the surface are cyclical and unstable what causes the appearance of slugs inside the separator, mainly in the gas phase, because introduce significant errors in the measurement system (e.g.: overrange error). The flow gas analysis proposed in this work is based on two mathematical models used together: i) a plunger lift well model proposed by Baruzzi [1] with later modifications made by Bolonhini [2] to built a plunger lift simulator; ii) a two-phase separator model (gas + liquid) based from a three-phase separator model (gas + oil + water) proposed by Nunes [3]. Based on the models above and with field data collected from the well test separator of PUB-02 platform (Ubarana sea field) it was possible to demonstrate that the output gas flow of the separator can be estimate, with a reasonable precision, from the control signal of the Pressure Control Valve (PCV). Several models of the System Identification Toolbox from MATLAB® were analyzed to evaluate which one better fit to the data collected from the field. For validation of the models, it was used the AIC criterion, as well as a variant of the cross validation criterion. The ARX model performance was the best one to fit to the data and, this way, we decided to evaluate a recursive algorithm (RARX) also with real time data. The results were quite promising that indicating the viability to estimate the output gas flow rate from a plunger lift well producing to a well test separator, with the built-in information of the control signal to the PCV

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to develop a pilot plant which the main goal is to emulate a flow peak pressure in a separation vessel. Effect similar that is caused by the production in a slug flow in production wells equipped with the artificial lift method plunger lift. The motivation for its development was the need to test in a plant on a smaller scale, a new technique developed to estimate the gas flow in production wells equipped with plunger lift. To develop it, studies about multiphase flow effects, operation methods of artificial lift in plunger lift wells, industrial instrumentation elements, control valves, vessel sizing separators and measurement systems were done. The methodology used was the definition of process flowcharts, its parameters and how the effects needed would be generated for the success of the experiments. Therefore, control valves, the design and construction of vessels and the acquisition of other equipment used were defined. One of the vessels works as a tank of compressed air that is connected to the separation vessel and generates pulses of gas controlled by a on/off valve. With the emulator system ready, several control experiments were made, being the control of peak flow pressure generation and the flow meter the main experiments, this way, it was confirmed the efficiency of the plant usage in the problem that motivated it. It was concluded that the system is capable of generate effects of flow with peak pressure in a primary separation vessel. Studies such as the estimation of gas flow at the exit of the vessel and several academic studies can be done and tested on a smaller scale and then applied in real plants, avoiding waste of time and money.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Slugging is a well-known slugging phenomenon in multiphase flow, which may cause problems such as vibration in pipeline and high liquid level in the separator. It can be classified according to the place of its occurrence. The most severe, known as slugging in the riser, occurs in the vertical pipe which feeds the platform. Also known as severe slugging, it is capable of causing severe pressure fluctuations in the flow of the process, excessive vibration, flooding in separator tanks, limited production, nonscheduled stop of production, among other negative aspects that motivated the production of this work . A feasible solution to deal with this problem would be to design an effective method for the removal or reduction of the system, a controller. According to the literature, a conventional PID controller did not produce good results due to the high degree of nonlinearity of the process, fueling the development of advanced control techniques. Among these, the model predictive controller (MPC), where the control action results from the solution of an optimization problem, it is robust, can incorporate physical and /or security constraints. The objective of this work is to apply a non-conventional non-linear model predictive control technique to severe slugging, where the amount of liquid mass in the riser is controlled by the production valve and, indirectly, the oscillation of flow and pressure is suppressed, while looking for environmental and economic benefits. The proposed strategy is based on the use of the model linear approximations and repeatedly solving of a quadratic optimization problem, providing solutions that improve at each iteration. In the event where the convergence of this algorithm is satisfied, the predicted values of the process variables are the same as to those obtained by the original nonlinear model, ensuring that the constraints are satisfied for them along the prediction horizon. A mathematical model recently published in the literature, capable of representing characteristics of severe slugging in a real oil well, is used both for simulation and for the project of the proposed controller, whose performance is compared to a linear MPC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The continuous gas lift method is the main artificial lifting method used in the oil industry for submarine wells, due to its robustness and the large range of flow rate that the well might operate. Nowadays, there is a huge amount of wells producing under this mechanism. This method of elevation has a slow dynamics due to the transients and a correlation between the injected gas rate and the of produced oil rate. Electronics controllers have been used to adjust many parameters of the oil wells and also to improve the efficiency of the gas lift injection system. This paper presents a intelligent control system applied to continuous gas injection in wells, based in production s rules, that has the target of keeping the wells producing during the maximum period of time, in its best operational condition, and doing automatically all necessary adjustments when occurs some disturbance in the system. The author also describes the application of the intelligent control system as a tool to control the flow pressure in the botton of the well (Pwf). In this case, the control system actuates in the surface control valve

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electro-hydraulic servo-systems are widely employed in industrial applications such as robotic manipulators, active suspensions, precision machine tools and aerospace systems. They provide many advantages over electric motors, including high force to weight ratio, fast response time and compact size. However, precise control of electro-hydraulic systems, due to their inherent nonlinear characteristics, cannot be easily obtained with conventional linear controllers. Most flow control valves can also exhibit some hard nonlinearities such as deadzone due to valve spool overlap on the passage´s orifice of the fluid. This work describes the development of a nonlinear controller based on the feedback linearization method and including a fuzzy compensation scheme for an electro-hydraulic actuated system with unknown dead-band. Numerical results are presented in order to demonstrate the control system performance

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A critical problem in mature gas wells is the liquid loading. As the reservoir pressure decreases, gas superficial velocities decreases and the drag exerted on the liquid phase may become insufficient to bring all the liquid to the surface. Liquid starts to drain downward, flooding the well and increasing the backpressure which decreases the gas superficial velocity and so on. A popular method to remedy this problem is the Plunger Lift. This method consists of dropping the "plunger"to the bottom of the tubing well with the main production valve closed. When the plunger reaches the well bottom the production valve is opened and the plunger carry the liquid to the surface. However, models presented in literature for predicting the behavior in plunger lift are simplistic, in many cases static (not considering the transient effects). Therefore work presents the development and validation of a numerical algorithm to solve one-dimensional compressible in gas wells using the Finite Volume Method and PRIME techniques for treating coupling of pressure and velocity fields. The code will be then used to develop a dynamic model for the plunger lift which includes the transient compressible flow within the well

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The treatment of wastewaters contaminated with oil is of great practical interest and it is fundamental in environmental issues. A relevant process, which has been studied on continuous treatment of contaminated water with oil, is the equipment denominated MDIF® (a mixer-settler based on phase inversion). An important variable during the operation of MDIF® is the water-solvent interface level in the separation section. The control of this level is essential both to avoid the dragging of the solvent during the water removal and improve the extraction efficiency of the oil by the solvent. The measurement of oil-water interface level (in line) is still a hard task. There are few sensors able to measure oil-water interface level in a reliable way. In the case of lab scale systems, there are no interface sensors with compatible dimensions. The objective of this work was to implement a level control system to the organic solvent/water interface level on the equipment MDIF®. The detection of the interface level is based on the acquisition and treatment of images obtained dynamically through a standard camera (webcam). The control strategy was developed to operate in feedback mode, where the level measure obtained by image detection is compared to the desired level and an action is taken on a control valve according to an implemented PID law. A control and data acquisition program was developed in Fortran to accomplish the following tasks: image acquisition; water-solvent interface identification; to perform decisions and send control signals; and to record data in files. Some experimental runs in open-loop were carried out using the MDIF® and random pulse disturbances were applied on the input variable (water outlet flow). The responses of interface level permitted the process identification by transfer models. From these models, the parameters for a PID controller were tuned by direct synthesis and tests in closed-loop were performed. Preliminary results for the feedback loop demonstrated that the sensor and the control strategy developed in this work were suitable for the control of organic solvent-water interface level

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)