975 resultados para subjective evaluation
Resumo:
Micro-generation is the small scale production of heat and/or electricity from a low carbon source and can be a powerful driver for carbon reduction, behavior change, security of supply and economic value. The energy conversion technologies can include photovoltaic panels, micro combined heat and power, micro wind, heat pumps, solar thermal systems, fuel cells and micro hydro schemes. In this paper, a small research of the availability of the conversion apparatus and the prices for the micro wind turbines and photovoltaic systems is made and a comparison between these two technologies is performed in terms of the availability of the resource and costs. An analysis of the new legal framework published in Portugal is done to realize if the incentives to individualspsila investment in sustainable and local energy production is worth for their point of view. An economic evaluation for these alternatives, accounting with the governmentpsilas incentives should lead, in most cases, into attractive return rates for the investment. Apart from the attractiveness of the investment there are though other aspects that should be taken into account and those are the benefits that these choices have to us all. The idea is that micro-generation will not only make a significant direct contribution to carbon reduction targets, it will also trigger a multiplier effect in behavior change by engaging hearts and minds, and providing more efficient use of energy by householders. The diversified profile of power generation by micro-generators, both in terms of location and timing, should reduce the impact of intermittency or plant failures with significant gains for security of supply.
Resumo:
Academic evaluation has been an essential component of modern science since its inception, as science has moved away from personalized patronage toward its contemporary role as an essential enterprise of contemporary, democratic societies. In recent years, Brazil has experienced sustained growth in its scientific output, which is nowadays fully compatible with its status as a high middle-income country striving to become a fully developed, more equitable country in the years to come. Growth usually takes place amidst challenges and dilemmas and, in Brazil as elsewhere, academic evaluation is not exempt from such difficulties. In a large, profoundly heterogeneous country with a national evaluation system and nationwide on-line platforms disseminating information on the most disparate fields of knowledge, the main challenges refer to how to pay attention to detail without losing sight of comprehensiveness and how to handle social and regional diversity while preserving academic excellence as the fundamental benchmark.
Resumo:
Introduction: The purpose of this review is to gather and analyse current research publications to evaluate Sinogram-Affirmed Iterative Reconstruction (SAFIRE). The aim of this review is to investigate whether this algorithm is capable of reducing the dose delivered during CT imaging while maintaining image quality. Recent research shows that children have a greater risk per unit dose due to increased radiosensitivity and longer life expectancies, which means it is particularly important to reduce the radiation dose received by children. Discussion: Recent publications suggest that SAFIRE is capable of reducing image noise in CT images, thereby enabling the potential to reduce dose. Some publications suggest a decrease in dose, by up to 64% compared to filtered back projection, can be accomplished without a change in image quality. However, literature suggests that using a higher SAFIRE strength may alter the image texture, creating an overly ‘smoothed’ image that lacks contrast. Some literature reports SAFIRE gives decreased low contrast detectability as well as spatial resolution. Publications tend to agree that SAFIRE strength three is optimal for an acceptable level of visual image quality, but more research is required. The importance of creating a balance between dose reduction and image quality is stressed. In this literature review most of the publications were completed using adults or phantoms, and a distinct lack of literature for paediatric patients is noted. Conclusion: It is necessary to find an optimal way to balance dose reduction and image quality. More research relating to SAFIRE and paediatric patients is required to fully investigate dose reduction potential in this population, for a range of different SAFIRE strengths.
Resumo:
The IEEE 802.15.4 protocol has the ability to support time-sensitive Wireless Sensor Network (WSN) applications due to the Guaranteed Time Slot (GTS) Medium Access Control mechanism. Recently, several analytical and simulation models of the IEEE 802.15.4 protocol have been proposed. Nevertheless, currently available simulation models for this protocol are both inaccurate and incomplete, and in particular they do not support the GTS mechanism. In this paper, we propose an accurate OPNET simulation model, with focus on the implementation of the GTS mechanism. The motivation that has driven this work is the validation of the Network Calculus based analytical model of the GTS mechanism that has been previously proposed and to compare the performance evaluation of the protocol as given by the two alternative approaches. Therefore, in this paper we contribute an accurate OPNET model for the IEEE 802.15.4 protocol. Additionally, and probably more importantly, based on the simulation model we propose a novel methodology to tune the protocol parameters such that a better performance of the protocol can be guaranteed, both concerning maximizing the throughput of the allocated GTS as well as concerning minimizing frame delay.
Resumo:
This report is made for the Work Package 15 of WORKS project and tries to develop more information on the Portuguese situation in the work structures changes in the recent years. It starts with an analysis of socio- economical indicators (Macro economical indicators, Employment indicators, Consumption, Technology at the workplace, Productivity), and then approaches the situation in terms of work flexibility in its dimensions of time use and New forms of work organisation. It traces employment in business functions with a sectoral and occupational approach, and analyses the occupational change in South Europe with particular relevance to Portugal (skill utilisation and job satisfaction, occupational and industrial mobility, quantitative evaluation of the shape of employment in Europe. Finaly are analysed the globalisation indicators.
Resumo:
The discovery of X-rays was undoubtedly one of the greatest stimulus for improving the efficiency in the provision of healthcare services. The ability to view, non-invasively, inside the human body has greatly facilitated the work of professionals in diagnosis of diseases. The exclusive focus on image quality (IQ), without understanding how they are obtained, affect negatively the efficiency in diagnostic radiology. The equilibrium between the benefits and the risks are often forgotten. It is necessary to adopt optimization strategies to maximize the benefits (image quality) and minimize risk (dose to the patient) in radiological facilities. In radiology, the implementation of optimization strategies involves an understanding of images acquisition process. When a radiographer adopts a certain value of a parameter (tube potential [kVp], tube current-exposure time product [mAs] or additional filtration), it is essential to know its meaning and impact of their variation in dose and image quality. Without this, any optimization strategy will be a failure. Worldwide, data show that use of x-rays has been increasingly frequent. In Cabo Verde, we note an effort by healthcare institutions (e.g. Ministry of Health) in equipping radiological facilities and the recent installation of a telemedicine system requires purchase of new radiological equipment. In addition, the transition from screen-films to digital systems is characterized by a raise in patient exposure. Given that this transition is slower in less developed countries, as is the case of Cabo Verde, the need to adopt optimization strategies becomes increasingly necessary. This study was conducted as an attempt to answer that need. Although this work is about objective evaluation of image quality, and in medical practice the evaluation is usually subjective (visual evaluation of images by radiographer / radiologist), studies reported a correlation between these two types of evaluation (objective and subjective) [5-7] which accredits for conducting such studies. The purpose of this study is to evaluate the effect of exposure parameters (kVp and mAs) when using additional Cooper (Cu) filtration in dose and image quality in a Computed Radiography system.
Resumo:
Considering that recent european high-speed railway system has a traction power system of kV 50 Hz, which causes electromagnetic emission for the outside world, it is important to dimension the railway system emissions, using a frequency/distance dependent propagation model. This paper presents an enhanced theoretical model for VLF to UHF propagation, railway system oriented. It introduces the near field approach (crucial in low frequency propagation) and also considers the source characteristics and type of measuring antenna. Simulations are presented, and comparisons are set with earlier far field models. Using the developed model, a real case study was performed in partnership with Refer Telecom (portuguese telecom operator for railways). The new propagation model was used in order to predict the future high-speed railway electromagnetic emissions in the Lisbon north track. The results show the model's prediction capabilities and also its applicability to realistic scenarios.
Resumo:
Radio frequency (RF) energy harvesting is an emerging technology that will enable to drive the next generation of wireless sensor networks (WSNs) without the need of using batteries. In this paper, we present RF energy harvesting circuits specifically developed for GSM bands (900/1800) and a wearable dual-band antenna suitable for possible implementation within clothes for body worn applications. Besides, we address the development and experimental characterization of three different prototypes of a five-stage Dickson voltage multiplier (with match impedance circuit) responsible for harvesting the RF energy. Different printed circuit board (PCB) fabrication techniques to produce the prototypes result in different values of conversion efficiency. Therefore, we conclude that if the PCB fabrication is achieved by means of a rigorous control in the photo-positive method and chemical bath procedure applied to the PCB it allows for attaining better values for the conversion efficiency. All three prototypes (1, 2 and 3) can power supply the IRIS sensor node for RF received powers of -4 dBm, -6 dBm and -5 dBm, and conversion efficiencies of 20, 32 and 26%, respectively. © 2014 IEEE.
Resumo:
OBJECTIVE Develop an index to evaluate the maternal and neonatal hospital care of the Brazilian Unified Health System.METHODS This descriptive cross-sectional study of national scope was based on the structure-process-outcome framework proposed by Donabedian and on comprehensive health care. Data from the Hospital Information System and the National Registry of Health Establishments were used. The maternal and neonatal network of Brazilian Unified Health System consisted of 3,400 hospitals that performed at least 12 deliveries in 2009 or whose number of deliveries represented 10.0% or more of the total admissions in 2009. Relevance and reliability were defined as criteria for the selection of variables. Simple and composite indicators and the index of completeness were constructed and evaluated, and the distribution of maternal and neonatal hospital care was assessed in different regions of the country.RESULTS A total of 40 variables were selected, from which 27 single indicators, five composite indicators, and the index of completeness of care were built. Composite indicators were constructed by grouping simple indicators and included the following variables: hospital size, level of complexity, delivery care practice, recommended hospital practice, and epidemiological practice. The index of completeness of care grouped the five variables and classified them in ascending order, thereby yielding five levels of completeness of maternal and neonatal hospital care: very low, low, intermediate, high, and very high. The hospital network was predominantly of small size and low complexity, with inadequate child delivery care and poor development of recommended and epidemiological practices. The index showed that more than 80.0% hospitals had a low index of completeness of care and that most qualified heath care services were concentrated in the more developed regions of the country.CONCLUSIONS The index of completeness proved to be of great value for monitoring the maternal and neonatal hospital care of Brazilian Unified Health System and indicated that the quality of health care was unsatisfactory. However, its application does not replace specific evaluations.
Resumo:
The characteristics of carbon fibre reinforced laminates had widened their use, from aerospace to domestic appliances. A common characteristic is the need of drilling for assembly purposes. It is known that a drilling process that reduces the drill thrust force can decrease the risk of delamination. In this work, delamination assessment methods based on radiographic data are compared and correlated with mechanical test results (bearing test).
Resumo:
The performance of the Weather Research and Forecast (WRF) model in wind simulation was evaluated under different numerical and physical options for an area of Portugal, located in complex terrain and characterized by its significant wind energy resource. The grid nudging and integration time of the simulations were the tested numerical options. Since the goal is to simulate the near-surface wind, the physical parameterization schemes regarding the boundary layer were the ones under evaluation. Also, the influences of the local terrain complexity and simulation domain resolution on the model results were also studied. Data from three wind measuring stations located within the chosen area were compared with the model results, in terms of Root Mean Square Error, Standard Deviation Error and Bias. Wind speed histograms, occurrences and energy wind roses were also used for model evaluation. Globally, the model accurately reproduced the local wind regime, despite a significant underestimation of the wind speed. The wind direction is reasonably simulated by the model especially in wind regimes where there is a clear dominant sector, but in the presence of low wind speeds the characterization of the wind direction (observed and simulated) is very subjective and led to higher deviations between simulations and observations. Within the tested options, results show that the use of grid nudging in simulations that should not exceed an integration time of 2 days is the best numerical configuration, and the parameterization set composed by the physical schemes MM5–Yonsei University–Noah are the most suitable for this site. Results were poorer in sites with higher terrain complexity, mainly due to limitations of the terrain data supplied to the model. The increase of the simulation domain resolution alone is not enough to significantly improve the model performance. Results suggest that error minimization in the wind simulation can be achieved by testing and choosing a suitable numerical and physical configuration for the region of interest together with the use of high resolution terrain data, if available.
Resumo:
Applications involving biosignals, such as Electrocardiography (ECG), are becoming more pervasive with the extension towards non-intrusive scenarios helping targeting ambulatory healthcare monitoring, emotion assessment, among many others. In this study we introduce a new type of silver/silver chloride (Ag/AgCl) electrodes based on a paper substrate and produced using an inkjet printing technique. This type of electrodes can increase the potential applications of biosignal acquisition technologies for everyday life use, given that there are several advantages, such as cost reduction and easier recycling, resultant from the approach explored in our work. We performed a comparison study to assess the quality of this new electrode type, in which ECG data was collected with three types of Ag/AgCl electrodes: i) gelled; ii) dry iii) paper-based inkjet printed. We also compared the performance of each electrode when acquired using a professional-grade gold standard device, and a low cost platform. Experimental results showed that data acquired using our proposed inkjet printed electrode is highly correlated with data obtained through conventional electrodes. Moreover, the electrodes are robust to high-end and low-end data acquisition devices. Copyright © 2014 SCITEPRESS - Science and Technology Publications. All rights reserved.
Resumo:
OBJECTIVE To develop a model for evaluating the efficacy of drug-dispensing service in primary health care. METHODS An efficacy criterion was adopted to determine the level of achievement of the service objectives. The evaluation model was developed on the basis of a literature search and discussions with experts. The applicability test of the model was conducted in 15 primary health care units in the city of Florianópolis, state of Santa Catarina, in 2010, and data were recorded in structured and pretested questionnaires. RESULTS The model developed was evaluated using five dimensions of analysis for analysis. The model was suitable for evaluating service efficacy and helped to identify the critical points of each service dimension. CONCLUSIONS Adaptations to the data collection technique may be required to adjust for the reality and needs of each situation. The evaluation of the drug-dispensing service should promote adequate access to medications supplied through the public health system.
Resumo:
OBJECTIVE To assess the validity of dengue fever reports and how they relate to the definition of case and severity. METHODS Diagnostic test assessment was conducted using cross-sectional sampling from a universe of 13,873 patients treated during the fifth epidemiological period in health institutions from 11 Colombian departments in 2013. The test under analyses was the reporting to the National Public Health Surveillance System, and the reference standard was the review of histories identified by active institutional search. We reviewed all histories of patients diagnosed with dengue fever, as well as a random sample of patients with febrile syndromes. The specificity and sensitivity of reports were estimated for this purpose, considering the inverse of the probability of being selected for weighting. The concordance between reporting and the findings of the active institutional search was calculated using Kappa statistics. RESULTS We included 4,359 febrile patients, and 31.7% were classified as compatible with dengue fever (17 with severe dengue fever; 461 with dengue fever and warning signs; 904 with dengue fever and no warning signs). The global sensitivity of reports was 13.2% (95%CI 10.9;15.4) and specificity was 98.4% (95%CI 97.9;98.9). Sensitivity varied according to severity: 12.1% (95%CI 9.3;14.8) for patients presenting dengue fever with no warning signs; 14.5% (95%CI 10.6;18.4) for those presenting dengue fever with warning signs, and 40.0% (95%CI 9.6;70.4) for those with severe dengue fever. Concordance between reporting and the findings of the active institutional search resulted in a Kappa of 10.1%. CONCLUSIONS Low concordance was observed between reporting and the review of clinical histories, which was associated with the low reporting of dengue fever compatible cases, especially milder cases.
Resumo:
For musicians, the impact of noise exposure is not yet fully characterized. Some inconsistencies can be found in the methodology used to evaluate noise exposure. This study aims to analyze the noise exposure of musicians in a symphonic orchestra to understand their risk for hearing loss, applying the methodology proposed by ISO 9612:2009. Noise levels were monitored among musicians during the rehearsal of eight different repertoires. Test subjects were selected according to their instrument and position in the orchestra. Participants wore noise dosimeters throughout the rehearsals. A sound meter was used to analyze the exposure of the conductor. The results showed that musicians are exposed to high noise levels that can damage hearing. Brass, woodwind and percussion and timpani musicians were exposed to noise levels in excess of the upper exposure action level of 85 dB (A), while the other instrumental groups had a lower exposure action level of 80 dB (A). Percussion musicians were exposed to high peak noise levels of 135 dB (C). Sound levels varied by instrument, repertoire and position. Octave frequency analyses showed differences among musicians. This study suggests that musicians are at risk for hearing loss. There is a need for more effective guidelines applicable to all countries, which should define standardized procedures for determining musician noise exposure and should allow exposure level normalization to the year, including different repertoires.