935 resultados para periodic perturbations


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Crystal structure determination at room temperature [292 (2) K] of racemic 1,1'-binaphthalene-2,2'-diyl diethyl bis(carbonate), C26H22O6, showed that one of the terminal carbon-carbon bond lengths is very short [Csp(3)-Csp(3) = 1.327 (6) angstrom]. The reason for such a short bond length has been analysed by collecting data sets on the same crystal at 393, 150 and 90 K. The values of the corrected bond lengths clearly suggest that the shortening is mainly due to positional disorder at two sites, with minor perturbations arising as a result of thermal vibrations. The positional disorder has been resolved in the analysis of the 90 K data following the changes in the unit-cell parameters for the data sets at 150 and 90 K, which appear to be an artifact of a near centre of symmetry relationship between the two independent molecules in the space group P (1) over bar at these temperatures. Indeed, the unit cell at low temperature (150 and 90 K) is a supercell of the room-temperature unit cell.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Using asymptotics, the coupled wavenumbers in an infinite fluid-filled flexible cylindrical shell vibrating in the beam mode (viz. circumferential wave order n = 1) are studied. Initially, the uncoupled wavenumbers of the acoustic fluid and the cylindrical shell structure are discussed. Simple closed form expressions for the structural wavenumbers (longitudinal, torsional and bending) are derived using asymptotic methods for low- and high-frequencies. It is found that at low frequencies the cylinder in the beam mode behaves like a Timoshenko beam. Next, the coupled dispersion equation of the system is rewritten in the form of the uncoupled dispersion equation of the structure and the acoustic fluid, with an added fluid-loading term involving a parameter mu due to the coupling. An asymptotic expansion involving mu is substituted in this equation. Analytical expressions are derived for the coupled wavenumbers (as modifications to the uncoupled wavenumbers) separately for low- and high-frequency ranges and further, within each frequency range, for large and small values of mu. Only the flexural wavenumber, the first rigid duct acoustic cut-on wavenumber and the first pressure-release acoustic cut-on wavenumber are considered. The general trend found is that for small mu, the coupled wavenumbers are close to the in vacuo structural wavenumber and the wavenumbers of the rigid-acoustic duct. With increasing mu, the perturbations increase, until the coupled wavenumbers are better identified as perturbations to the pressure-release wavenumbers. The systematic derivation for the separate cases of small and large mu gives more insight into the physics and helps to continuously track the wavenumber solutions as the fluid-loading parameter is varied from small to large values. Also, it is found that at any frequency where two wavenumbers intersect in the uncoupled analysis, there is no more an intersection in the coupled case, but a gap is created at that frequency. This method of asymptotics is simple to implement using a symbolic computation package (like Maple). (C) 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

P-Nickel hydroxide comprises a long range periodic arrangement of atoms with a stacking sequence of AC AC AC-having an ideal composition Ni(OH)(2). Variation in the preparative conditions can lead to the changes in the stacking sequence (AC AC BA CB AC AC or AC AC AB AC AC) This type of variation in stacking sequence can result in the formation of stacking fault in nickel hydroxide. The stability of the stacking fault depends on the free energy content of the sample. Stacking faults in nickel hydroxide is essential for better electrochemical activity. Also there are reports correlating particle size to the better electrochemical activity. Here we present the effect of crystallite size on the stacking faulted nickel hydroxide samples. The electrochemical performance of stacking faulted nickel hydroxide with small crystallite size exchanges 0.8e/Ni, while the samples with larger crystallite size exchange 0.4e/Ni. Hence a right combination of crystallite size and stacking fault content has to be controlled for good electrochemical activity of nickel hydroxide. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pediatric renal transplantation (TX) has evolved greatly during the past few decades, and today TX is considered the standard care for children with end-stage renal disease. In Finland, 191 children had received renal transplants by October 2007, and 42% of them have already reached adulthood. Improvements in treatment of end-stage renal disease, surgical techniques, intensive care medicine, and in immunosuppressive therapy have paved the way to the current highly successful outcomes of pediatric transplantation. In children, the transplanted graft should last for decades, and normal growth and development should be guaranteed. These objectives set considerable requirements in optimizing and fine-tuning the post-operative therapy. Careful optimization of immunosuppressive therapy is crucial in protecting the graft against rejection, but also in protecting the patient against adverse effects of the medication. In the present study, the results of a retrospective investigation into individualized dosing of immunosuppresive medication, based on pharmacokinetic profiles, therapeutic drug monitoring, graft function and histology studies, and glucocorticoid biological activity determinations, are reported. Subgroups of a total of 178 patients, who received renal transplants in 1988 2006 were included in the study. The mean age at TX was 6.5 years, and approximately 26% of the patients were <2 years of age. The most common diagnosis leading to renal TX was congenital nephrosis of the Finnish type (NPHS1). Pediatric patients in Finland receive standard triple immunosuppression consisting of cyclosporine A (CsA), methylprednisolone (MP) and azathioprine (AZA) after renal TX. Optimal dosing of these agents is important to prevent rejections and preserve graft function in one hand, and to avoid the potentially serious adverse effects on the other hand. CsA has a narrow therapeutic window and individually variable pharmacokinetics. Therapeutic monitoring of CsA is, therefore, mandatory. Traditionally, CsA monitoring has been based on pre-dose trough levels (C0), but recent pharmacokinetic and clinical studies have revealed that the immunosuppressive effect may be related to diurnal CsA exposure and blood CsA concentration 0-4 hours after dosing. The two-hour post-dose concentration (C2) has proved a reliable surrogate marker of CsA exposure. Individual starting doses of CsA were analyzed in 65 patients. A recommended dose based on a pre-TX pharmacokinetic study was calculated for each patient by the pre-TX protocol. The predicted dose was clearly higher in the youngest children than in the older ones (22.9±10.4 and 10.5±5.1 mg/kg/d in patients <2 and >8 years of age, respectively). The actually administered oral doses of CsA were collected for three weeks after TX and compared to the pharmacokinetically predicted dose. After the TX, dosing of CsA was adjusted according to clinical parameters and blood CsA trough concentration. The pharmacokinetically predicted dose and patient age were the two significant parameters explaining post-TX doses of CsA. Accordingly, young children received significantly higher oral doses of CsA than the older ones. The correlation to the actually administered doses after TX was best in those patients, who had a predicted dose clearly higher or lower (> ±25%) than the average in their age-group. Due to the great individual variation in pharmacokinetics standardized dosing of CsA (based on body mass or surface area) may not be adequate. Pre-Tx profiles are helpful in determining suitable initial CsA doses. CsA monitoring based on trough and C2 concentrations was analyzed in 47 patients, who received renal transplants in 2001 2006. C0, C2 and experienced acute rejections were collected during the post-TX hospitalization, and also three months after TX when the first protocol core biopsy was obtained. The patients who remained rejection free had slightly higher C2 concentrations, especially very early after TX. However, after the first two weeks also the trough level was higher in the rejection-free patients than in those with acute rejections. Three months after TX the trough level was higher in patients with normal histology than in those with rejection changes in the routine biopsy. Monitoring of both the trough level and C2 may thus be warranted to guarantee sufficient peak concentration and baseline immunosuppression on one hand and to avoid over-exposure on the other hand. Controlling of rejection in the early months after transplantation is crucial as it may contribute to the development of long-term allograft nephropathy. Recently, it has become evident that immunoactivation fulfilling the histological criteria of acute rejection is possible in a well functioning graft with no clinical sings or laboratory perturbations. The influence of treatment of subclinical rejection, diagnosed in 3-month protocol biopsy, to graft function and histology 18 months after TX was analyzed in 22 patients and compared to 35 historical control patients. The incidence of subclinical rejection at three months was 43%, and the patients received a standard rejection treatment (a course of increased MP) and/or increased baseline immunosuppression, depending on the severity of rejection and graft function. Glomerular filtration rate (GFR) at 18 months was significantly better in the patients who were screened and treated for subclinical rejection in comparison to the historical patients (86.7±22.5 vs. 67.9±31.9 ml/min/1.73m2, respectively). The improvement was most remarkable in the youngest (<2 years) age group (94.1±11.0 vs. 67.9±26.8 ml/min/1.73m2). Histological findings of chronic allograft nephropathy were also more common in the historical patients in the 18-month protocol biopsy. All pediatric renal TX patients receive MP as a part of the baseline immunosuppression. Although the maintenance dose of MP is very low in the majority of the patients, the well-known steroid-related adverse affects are not uncommon. It has been shown in a previous study in Finnish pediatric TX patients that steroid exposure, measured as area under concentration-time curve (AUC), rather than the dose correlates with the adverse effects. In the present study, MP AUC was measured in sixteen stable maintenance patients, and a correlation with excess weight gain during 12 months after TX as well as with height deficit was found. A novel bioassay measuring the activation of glucocorticoid receptor dependent transcription cascade was also employed to assess the biological effect of MP. Glucocorticoid bioactivity was found to be related to the adverse effects, although the relationship was not as apparent as that with serum MP concentration. The findings in this study support individualized monitoring and adjustment of immunosuppression based on pharmacokinetics, graft function and histology. Pharmacokinetic profiles are helpful in estimating drug exposure and thus identifying the patients who might be at risk for excessive or insufficient immunosuppression. Individualized doses and monitoring of blood concentrations should definitely be employed with CsA, but possibly also with steroids. As an alternative to complete steroid withdrawal, individualized dosing based on drug exposure monitoring might help in avoiding the adverse effects. Early screening and treatment of subclinical immunoactivation is beneficial as it improves the prospects of good long-term graft function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Wave propagation and its frequency bandgaps in a parametrically modulated composite laminate are reported in this paper. The modulated properties under considerations are due to periodic microstructure, for example honeycomb core sandwich composite, which can be parameterized and homogenized in a suitable scale. Wave equations are derived by assuming a third-order shear deformation theory. Homogenization of the wave equations is carried out in the scale of wavelength. In-plane wave and flexural-shear wave dispersions are obtained for a range of values of a stiffness modulation coefficient (alpha). A clear pattern of stop-bands is observed for alpha >= 4. To validate the band-gap phenomena, we take recourse to time domain response obtained from finite element simulation. As predicted by the proposed analytical technique, a distinct correlation between the chosen frequency band and the simulated wave arrival time and amplitude reduction is found. This promises practical applications of the proposed analytical technique to designing parametrically modulated composite laminate for wave suppression. (C) 2009 Elsevier B.V. All rights reserved.