981 resultados para orthopaedic implants


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Developments of surgical attachments for bone-anchored prostheses are slowly but surely winning over the initial disbelief in the orthopedic community. Clearly, this option is becoming accessible to a wide range of individuals with limb loss. Seminal studies have demonstrated that the pioneering procedure relying on screw-type fixation engenders major clinical benefits and acceptable safety. The surgical procedure for press-fit implants, such as the Integral-Leg-Prosthesis (ILP) has been described Dr Aschoff and his team. Some clinical benefits of press-fit implants have been also established. Here, his team is once again taking a leading role by sharing the progression over 15 years of the rate of deep infections for 69 individuals with transfemoral amputation fitted with three successive refined versions of the ILP. By definition, a double-blind randomized clinical trial to test the effect of different fixation’s design is difficult. Alternatively, Juhnke and colleagues are reporting the outcomes of action-research study for a cohort of participants. The first and foremost important outcome of this study is the confirmation that the current design of the IPL and rehabilitation program are altogether leading to an acceptable rate of deep infection and other adverse events (e.g., structural failure of implant, periprosthetic factures). This study is also providing a strong insight onto the effect of major phases in redesign of an implant on the risk of infection. This is an important reminder that the development of a successful osseointegrated implant is unlikely to be immediate but the results of a learning curve made of empirical and sequential changes led by a reflective clinical practice. Clearly, this study provided better understanding of the safety of the ILP surgical and rehabilitation procedure while establishing standards and benchmark data for future studies focusing on design and infection of press-fit implants. Complementary observations of relationship between infection and cofounders such as loading of the prosthesis and prosthetic components used would be beneficial.Further definitive evidences of the clinical benefits with the latest design would be valuable, although an increase in health related quality of life and functional outcomes are likely to be confirmed. Altogether, the authors are providing compelling evidence that bone-anchored attachments particularly those relying on press-fit implants are an established alternative to socket prostheses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective To test strategies for the application of dicyclanil and mid-season crutching to maximise protection of unmulesed sheep against breech strike. Procedure Three hundred and eighty unmulesed Merino weaners were randomly allocated to four groups either left untreated or treated by different strategies with 50 g/L dicyclanil. Treatments included breech treatment alone and breech plus body treatment, with two application times, immediately after shearing and 6 weeks after crutching or shearing. To assess protection, larval implants with newly hatched Lucilia cuprina larvae were applied to 10 different sheep from each group at 3, 4, 5 and 6 months after crutching and shearing and assessed for the development of strike at 48 hours. The concentration of dicyclanil was measured in wool samples clipped from the breeches of the test sheep. Results All dicyclanil treatments gave significant reduction in strike in comparison to controls up until 4 months after crutching but protection in the sheep treated immediately after shearing had waned at 5 months. Treating at 6 weeks after crutching provided significant reduction (P < 0.05) in strike for 6 months. Results for strike incidence immediately after shearing and concentration of dicyclanil in the breech wool also suggested improvements in protection by delaying treatment for 6 weeks. Conclusion In most environments it should be possible to protect unmulesed sheep against breech strike with a carefully planned integrated control program incorporating strategically timed crutching, shearing and dicyclanil application. Delaying treatment with dicyclanil to at least 6 weeks after shearing or crutching increased the protection provided in comparison to treatment immediately after shearing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anatomically precontoured plates are commonly used to treat periarticular fractures. A well-fitting plate can be used as a tool for anatomical reduction of the fractured bone. Recent studies highlighted that some plates fit poorly for many patients due to considerable shape variations between bones of the same anatomical site. While it is impossible to design one shape that fits all, it is also burdensome for the manufacturers and hospitals to produce, store and manage multiple plate shapes without the certainty of utilization by a patient population. In this study, we investigated the number of shapes required for maximum fit within a given dataset, and if they could be obtained by manually deforming the original plate. A distal medial tibial plate was automatically positioned on 45 individual tibiae, and the optimal deformation was determined iteratively using finite element analysis simulation. Within the studied dataset, we found that: (i) 89% fit could be achieved with four shapes, (ii) 100% fit was impossible through mechanical deformation, and (iii) the deformations required to obtain the four plate shapes were safe for the stainless steel plate for further clinical use. The proposed framework is easily transferable to other orthopaedic plates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total hip replacement is the golden standard treatment for severe osteoarthritis refractory for conservative treatment. Aseptic loosening and osteolysis are the major long-term complications after total hip replacement. Foreign body giant cells and osteoclasts are locally formed around aseptically loosening implants from precursor cells by cell fusion. When the foreign body response is fully developed, it mediates inflammatory and destructive host responses, such as collagen degradation. In the present study, it was hypothesized that the wear debris and foreign body inflammation are the forces driving local osteoclast formation, peri-implant bone resorption and enhanced tissue remodeling. Therefore the object was to characterize the eventual expression and the role of fusion molecules, ADAMs (an abbreviation for A Disintegrin And Metalloproteinase, ADAM9 and ADAM12) in the fusion of progenitor cells into multinuclear giant cells. For generation of such cells, activated macrophages trying to respond to foreign debris play an important role. Matured osteoclasts together with activated macrophages mediate bone destruction by secreting protons and proteinases, including matrix metalloproteinases (MMPs) and cathepsin K. Thus this study also assessed collagen degradation and its relationship to some of the key collagenolytic proteinases in the aggressive synovial membrane-like interface tissue around aseptically loosened hip replacement implants. ADAMs were found in the interface tissues of revision total hip replacement patients. Increased expression of ADAMs at both transcriptional and translational levels was found in synovial membrane-like interface tissue of revision total hip replacement (THR) samples compared with that in primary THR samples. These studies also demonstrate that multinucleate cell formation from monocytes by stimulation with macrophage-colony stimiulating factor (M-CSF) and receptor activator of nuclear factor kappa B ligand (RANKL) is characterized by time dependent changes of the proportion of ADAMs positive cells. This was observed both in the interface membrane in patients and in two different in vitro models. In addition to an already established MCS-F and RANKL driven model, a new virally (parainfluenza 2) driven model (of human salivary adenocarcinoma (HSY) cells or green monkey kidney (GMK) cells) was developed to study various fusion molecules and their role in cell fusion in general. In interface membranes, collagen was highly degraded and collagen degradation significantly correlated with the number of local cells containing collagenolytic enzymes, particularly cathepsin K. As a conclusion, fusion molecules ADAM9 and ADAM12 seem to be dynamically involved in cell-cell fusion processes and multinucleate cell formation. The highly significant correlation between collagen degradation and collagenolytic enzymes, particularly cathepsin K, indicates that the local acidity of the interface membrane in the pathologic bone and soft tissue destruction. This study provides profound knowledge about cell fusion and mechanism responsible for aseptic loosening as well as increases knowledge helpful for prevention and treatment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The genus Actinomyces consists of a heterogeneous group of gram-positive, mainly facultatively anaerobic or microaerobic rods showing various degrees of branching. In the oral cavity, streptococci and Actinomyces form a fundamental component of the indigenous microbiota, being among initial colonizers in polymicrobial biofilms. The significance of the genus Actinomyces is based on the capability of species to adhere to surfaces such as on teeth and to co-aggregate with other bacteria. Identification of Actinomyces species has mainly been based on only a few biochemical characteristics, such as pigmentation and catalase production, or on the use of a single commercial kit. The limited identification of oral Actinomyces isolates to species level has hampered knowledge of their role both in health and disease. In recent years, Actinomyces and related organisms have attracted the attention of clinical microbiologists because of a growing awareness of their presence in clinical specimens and their association with disease. This series of studies aimed to amplify the identification methods for Actinomyces species. With the newly developed identification scheme, the age-related occurrence of Actinomyces in healthy mouths of infants and their distribution in failed dental implants was investigated. Adhesion of Actinomyces species to titanium surfaces processed in various ways was studied in vitro. The results of phenotypic identification methods indicated a relatively low applicability of commercially available test kits for reliable identification within the genus Actinomyces. However, in the study of conventional phenotypic methods, it was possible to develop an identification scheme that resulted in accurate differentiation of Actinomyces and closely related species, using various different test methods. Genotypic methods based on 16S rRNA sequence analysis of Actinomyces proved to be a useful method for genus level identification and further clarified the species level identification with phenotypic methods. The results of the study of infants showed that the isolation frequency of salivary Actinomyces species increased according to age: thirty-one percent of the infants at 2 months but 97% at 2 years of age were positive for Actinomyces. A. odontolyticus was the most prominent Actinomyces colonizer during the study period followed in frequency by A. naeslundii and A. viscosus. In the study of explanted dental implants, Actinomyces was the most prevalent bacterial genus, colonizing 94% of the fixtures. Also in the implants A. odontolyticus was revealed as the most common Actinomyces species. It was present in 84% of Actinomyces -positive fixtures followed in frequency by A. naeslundii, A. viscosus and A. israelii. In an in vitro study of titanium surfaces, different Actinomyces species showed variation regarding their adhesion to titanium. Surface roughness as well as albumin coating of titanium had significant effects on adhesion. The use of improved phenotypic and molecular diagnostic methods increased the accuracy of the identification of the Actinomyces to species level. This facilitated an investigation of their occurrence and distribution in oral specimens in both health and disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Clinical utility of biodegradable magnesium implants is undermined by the untimely degradation of these materials in vivo. Their high corrosion rate leads to loss of mechanical integrity, peri–implant alkalization and localised accumulation of hydrogen gas. Biodegradable coatings were produced on pure magnesium using RF plasma polymerisation. A monoterpene alcohol with known anti-inflammatory and antibacterial properties was used as a polymer precursor. The addition of the polymeric layer was found to reduce the degradation rate of magnesium in simulated body fluid. The in vitro studies indicated good cytocompatibility of non-adherent THP–1 cells and mouse macrophage cells with the polymer, and the polymer coated sample. The viability of THP–1 cells was significantly improved when in contact with polymer encapsulated magnesium compared to unmodified samples. Collectively, these results suggest plasma enhanced polymer encapsulation of magnesium as a suitable method to control degradation kinetics of this biomaterial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Synthetic, natural, or composite, biomaterials occupy a key position in the management of disease and support continuous advancement of health care. Clinical utility of many permanent and biodegradable implants can be significantly improved via surface modification. Here, we discuss a novel polymer material developed from essential oil-based monoterpene alcohol using plasma polymerisation. The developed coatings are cytocompatible and limit adhesion and proliferation of a variety of pathogens. The coating can also be used to control degradation behaviour of resorbable materials, such as magnesium.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ageing population and a multitude of neurological and cardiovascular illnesses that cannot be mitigated by medication alone have resulted in a significant growth in the number of patients that require implantable electronic devices. These range from sensors, gastric and cardiac pacemakers, cardioverter defibrillators, to deep brain, nerve, and bone stimulators. Long-term implants present specific engineering challenges, including low energy consumption and stable performance. Resorbable electronics may offer excellent short-term performance without the need for surgical removal. However, most electronic materials have poor bio- and cytocompatibility, resulting in immune reactions and infections. This paper reviews the current situation and highlights challenges for future advancements.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Organic thin films have myriad of applications in biological interfaces, micro-electromechanical systems and organic electronics. Polyterpenol thin films fabricated via RF plasma polymerization have been substantiated as a promising gate insulating and encapsulating layer for organic optoelectronics, sacrificial place-holders for air gap fabrication as well as antibacterial coatings for medical implants. This study aims to understand the wettability and solubility behavior of the nonsynthetic polymer thin film, polyterpenol. Polyterpenol exhibited monopolar behavior, manifesting mostly electron donor properties, and was not water soluble due to the extensive intermolecular and intramolecular hydrogen bonds present. Hydrophobicity of polyterpenol surfaces increased for films fabricated at higher RF power attributed to reduction in oxygen containing functional groups and increased cross linking. The studies carried out under various deposition conditions vindicate that we could tailor the properties of the polyterpenol thin film for a given application.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The rising demand for medical implants for ageing populations and ongoing advancements in medical technology continue to drive the use of implantable devices. Higher implant usage has a consequent increased incidence of implant-related infections, and associated prolonged patient care, pain and loss of limb and other organ function. Numerous antibacterial surfaces have been designed that prevent the onset of biofilm formation, thus reducing or preventing implant-associated infections through inhibiting bacterial adhesion or by killing the organisms that successfully attach to the surface of the implant. Other surfaces have been designed to stimulate a local immune response, promoting the natural clearing of the invading pathogen. The desired antibacterial effects are typically achieved by modulating the surface chemistry and morphology of the implant material, by means of the controlled release of pharmacological agents and bioactive compounds from the surface of the material, or by a combination of both processes. An important issue for any type of antibacterial surface modification lies in balancing the non-fouling, bacteriostatic or bactericidal effects against local and systemic biocompatibility. In this chapter, we will first describe the concept of biocompatibility and its evolution, from devices that do not evoke a negative host response to those that actively drive host regeneration. We will then review the challenges associated with merging the need for an implant material to withstand a bacterial load with those associated with supporting function restoration and tissue healing.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Successful healing of long bone fractures is dependent on the mechanical environment created within the fracture, which in turn is dependent on the fixation strategy. Recent literature reports have suggested that locked plating devices are too stiff to reliably promote healing. However, in vitro testing of these devices has been inconsistent in both method of constraint and reported outcomes, making comparisons between studies and the assessment of construct stiffness problematic. Each of the methods previously used in the literature were assessed for their effect on the bending of the sample and concordant stiffness. The choice of outcome measures used in in vitro fracture studies was also assessed. Mechanical testing was conducted on seven hole locked plated constructs in each method for comparison. Based on the assessment of each method the use of spherical bearings, ball joints or similar is suggested at both ends of the sample. The use of near and far cortex movement was found to be more comprehensive and more accurate than traditional centrally calculated inter fragmentary movement values; stiffness was found to be highly susceptible to the accuracy of deformation measurements and constraint method, and should only be used as a within study comparison method. The reported stiffness values of locked plate constructs from in vitro mechanical testing is highly susceptible to testing constraints and output measures, with many standard techniques overestimating the stiffness of the construct. This raises the need for further investigation into the actual mechanical behaviour within the fracture gap of these devices.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This paper reviews the apparatus used for deformation of bone fracture fixation plates during orthopaedic surgeries including surgical irons, pliers and bending press tools. This paper extends the review to various machineries in non-medical industries and adopts their suitability to clinics-related applications and also covers the evolution of orthopaedic bone plates. This review confirms that none of the studied machineries can be implemented for the deformation of bone fracture fixation plates during orthopaedic surgeries. In addition, this paper also presents the novel apparatus that are designed from scratch for this specific purpose. Several conceptual designs have been proposed and evaluated recently. It has been found that Computer Numerical Control (CNC) systems are not the golden solution to this problem and one needs to attempt to design the robotic arm system. A new design of robotic arm that can be used for facilitating orthopaedic surgeries is being completed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The first aim of the current study was to evaluate the survival of total hip arthroplasty (THA) in patients aged 55 years and older on a nation-wide level. The second aim was to evaluate, on a nation wide-basis, the geographical variation of the incidence of primary THA for primary OA and also to identify those variables that are possibly associated with this variation. The third aim was to evaluate the effects of hospital volume: on the length of stay, on the numbers of re-admissions and on the numbers of complications of THR on population-based level in Finland. The survival of implants was analysed based on data from the Finnish Arthroplasty Register. The incidence and hospital volume data were obtained from the Hospital Discharge Register. Cementless total hip replacements had a significantly reduced risk of revision for aseptic loosening compared with cemented hip replacements. When revision for any reason was the end point in the survival analyses, there were no significant differences found between the groups. Adjusted incidence ratios of THA varied from 1.9- to 3.0-fold during the study period. Neither the average income within a region nor the morbidity index was associated with the incidence of THA. For the four categories of volume of total hip replacements performed per hospital, the length of the surgical treatment period was shorter for the highest volume group than for the lowest volume group. The odds ratio for dislocations was significantly lower in the high volume group than in the low volume group. In patients who were 55 years of age or older, the survival of cementless total hip replacements was as good as that of the cemented replacements. However, multiple wear-related revisions of the cementless cups indicate that excessive polyethylene wear was a major clinical problem with modular cementless cups. The variation in the long-term rates of survival for different cemented stems was considerable. Cementless proximal porous-coated stems were found to be a good option for elderly patients. When hip surgery was performed on with a large repertoire, the indications to perform THAs due to primary OA were tight. Socio-economic status of the patient had no apparent effect on THA rate. Specialization of hip replacements in high volume hospitals should reduce costs by significantly shortening the length of stay, and may reduce the dislocation rate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of the present experimental study was to find out if the applications of coralline hydroxyapatite (HA) can be improved by using bioabsorbable containment or binding substance with particulate HA in mandibular contour augmentation and by using bioabsorbable fibre-reinforced HA blocks in filling bone defects and in anterior lumbar interbody fusion. The use of a separate curved polyglycolide (PGA) containment alone or together with a fast resorbing polyglycolide/polylactide (PGA/PLA) binding substance were compared to the conventional non-contained method in ridge augmentation in sheep. The contained methods decreased HA migration, but the augmentations did not differ significantly. The use of the containment caused a risk for wound dehiscence and infection. Histologically there was a rapid connective tissue ingrowth into the HA graft and it was more abundant with the PGA containment compared to the non-contained augmentation and even additionally rich when the HA particles were bound with PGA/PLA copolymer. However, the bone ingrowth was best in the non-contained augmentation exceeding 10-12 % of the total graft area at 24 weeks. Negligible or no bone ingrowth was seen in the cases where the polymer composite was added to the HA particles and, related to that, foreign-body type cells were seen at the interface between the HA and host bone. The PGA and poly-dl/l-lactide (PDLLA) fibre-reinforced coralline HA blocks were studied in the metaphyseal and in the diaphyseal defects in rabbits. A rapid bone ingrowth was seen inside the both types of implants. Both PGA and PDLLA fibres induced an inflammatory fibrous reaction around themselves but it did not hinder the bone ingrowth. The bone ingrowth pattern was directed according to the loading conditions so that the load-carrying cortical ends of the implants as well as the implants sited in the diaphyseal defects were the most ossified. The fibre-reinforced coralline HA implants were further studied as stand-alone grafts in the lumbar anterior interbody implantation in pigs. The strength of the HA implants proved not to be adequate, the implants fractured in six weeks and the disc space was gradually lost similarly to that of the discectomized spaces. Histologically, small quantities of bone ingrowth was seen in some of the PGA and PDLLA reinforced coralline implants while no bone formation was identified in any of the PDLLA reinforced synthetic porous HA implants. While fragmented, the inner structure of the implants was lost, the bone ingrowth was minimal, and the disc was replaced by the fibrous connective tissue. When evaluated radiologically the grade of ossification was assessed as better than histologically, and, when related to the histologic findings, CT was more dependable than the plain films to show ossification of the implanted disc space. Local kyphosis was a frequent finding along with anterior bone bridging and ligament ossification as a consequence of instability of the implanted segment.