968 resultados para metastable solid solution
Resumo:
Accomplish high quality of final products in pharmaceutical industry is a challenge that requires the control and supervision of all the manufacturing steps. This request created the necessity of developing fast and accurate analytical methods. Near infrared spectroscopy together with chemometrics, fulfill this growing demand. The high speed providing relevant information and the versatility of its application to different types of samples lead these combined techniques as one of the most appropriated. This study is focused on the development of a calibration model able to determine amounts of API from industrial granulates using NIR, chemometrics and process spectra methodology.
Resumo:
In a previous paper a novel Generalized Multiobjective Multitree model (GMM-model) was proposed. This model considers for the first time multitree-multicast load balancing with splitting in a multiobjective context, whose mathematical solution is a whole Pareto optimal set that can include several results than it has been possible to find in the publications surveyed. To solve the GMM-model, in this paper a multi-objective evolutionary algorithm (MOEA) inspired by the Strength Pareto Evolutionary Algorithm (SPEA) is proposed. Experimental results considering up to 11 different objectives are presented for the well-known NSF network, with two simultaneous data flows
Resumo:
Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants
Resumo:
Gas chromatography (GC) is an analytical tool very useful to investigate the composition of gaseous mixtures. However, hydrogen (H2) detection after a GC separation is only possible with a Thermal Conductivity Detector (TCD), a Helium Ionisation Detector (HID) or expensive Atomic Emission Detector (AED). Recently, indirect H2 detection by GC coupled to mass spectrometry (MS) was demonstrated but the mechanism of carrier gas protonation remained unclear. With electron impact as ionisation source of MS and helium (He) as GC carrier gas, H2 is not ionised according the expected Penning ionisation neither according to the Associative ionisation. Rearrangement ionisation (RI) was found to be the main channel for H2 and D2 ionisation under GC-MS conditions used in most of laboratories using GC-MS, leading to the formation of [He−H]+ and [He−D]+ ions.
Resumo:
PURPOSE: Quality of care and its measurement represent a considerable challenge for pediatric smaller-scale comprehensive cancer centers (pSSCC) providing surgical oncology services. It remains unclear whether center size and/or yearly case-flow numbers influence the quality of care, and therefore impact outcomes for this population of patients. PATIENTS AND METHODS: We performed a 14-year, retrospective, single-center analysis, assessing adherence to treatment protocols and surgical adverse events as quality indicators in abdominal and thoracic pediatric solid tumor surgery. RESULTS: Forty-eight patients, enrolled in a research-associated treatment protocol, underwent 51 cancer-oriented surgical procedures. All the protocols contain precise technical criteria, indications, and instructions for tumor surgery. Overall, compliance with such items was very high, with 997/1,035 items (95 %) meeting protocol requirements. There was no surgical mortality. Twenty-one patients (43 %) had one or more complications, for a total of 34 complications (66 % of procedures). Overall, 85 % of complications were grade 1 or 2 according to Clavien-Dindo classification requiring observation or minor medical treatment. Case-sample and outcome/effectiveness data were comparable to published series. Overall, our data suggest that even with the modest caseload of a pSSCC within a Swiss tertiary academic hospital, compliance with international standards can be very high, and the incidence of adverse events can be kept minimal. CONCLUSION: Open and objective data sharing, and discussion between pSSCCs, will ultimately benefit our patient populations. Our study is an initial step towards the enhancement of critical self-review and quality-of-care measurements in this setting.
Resumo:
Actualment a Catalunya existeixen zones amb importants limitacions per l’aplicació de purins al sòl, pel que és imprescindible trobar alternatives de gestió i tractament que permetin l’aprofitament adequat dels recursos continguts a les dejeccions ramaderes sense afectar el medi. La digestió anaeròbia és una de les tècniques utilitzades en el tractament de les dejeccions ramaderes. L’efluent líquid que s’obté d’aquest tractament no modifica el contingut de nitrogen i fòsfor i per tant ha de ser gestionat correctament. L’objectiu general d’aquest projecte és avaluar la precipitació d’estruvita (sal de magnesi, amoni i fosfat) com una alternativa de gestió de l’efluent líquid d’una planta de digestió anaeròbia i compostatge que tracta dejeccions ramaderes conjuntament amb altres residus orgànics. S’han avaluat els efectes dels diferents paràmetres operacionals en la formació d’estruvita (pH, temperatura, velocitat d’agitació, alcalinitat), mitjançant assaigs en discontinu amb solució sintètica. A continuació s’ha procedit a obtenir estruvita a partir de la fracció líquida digerida de purí (FLD), en assaigs en discontinu per estudiar l’efecte del contingut de matèria orgànica i sòlids Totals (ST), així com el contingut en fosfats i el pH de reacció. Finalment, s’han optimitzat els paràmetres de procés en continu, mitjançant la posada en marxa d’un reactor a escala de laboratori i estudi de l’efecte de la velocitat d’agitació i de la introducció del stripping de CO2, tant amb solució sintètica com amb la fracció líquida digerida del purí. Dels resultats obtinguts es pot concloure que els factors que tenen una major influència en el procés d’obtenció d’estruvita són el pH (el pH òptim es situa al voltant de 9), i la presència de matèria orgànica i sòlids ens suspensió, que interfereix de forma quantitativa i qualitativa en la formació de l’estruvita. En el procés en continu s’ha aconseguit reduccions d’un 84% i 98% d’amoni i fòsfor respectivament, obtenintse estruvita que pot ser utilitzada com a fertilitzant d’alliberació lenta. Es pot concloure que la precipitació d’estruvita és una bona alternativa per millorar la gestió de les dejeccions ramaderes alhora que permet recuperar nutrients i tancar cicles. La combinació amb un tractament previ que elimini la matèria orgànica, com podria ser la digestió anaeròbia, i una separació de fases, per eliminar els sòlids en suspensió, es presenta com una configuració amb molts avantatges.
Resumo:
Audit report on the Shelby County Area Solid Waste Agency for the year ended June 30, 2009
Resumo:
Audit report on the Butler County Solid Waste Commission for the year ended June 30, 2009
Resumo:
Audit report on the Hardin County Sanitary Solid Waste Disposal Commission for the year ended June 30, 2009
Resumo:
Audit report on the Wayne-Ringgold-Decatur County Solid Waste Management Commission for the year ended June 30, 2009
Resumo:
Audit report on the Jones County Solid Waste Management Commission for the year ended June 30, 2009
Resumo:
Audit report on the Pocahontas County Solid Waste Commission for the year ended June 30, 2009