995 resultados para inferior right hepatic vein


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The liver is a key organ of metabolic homeostasis with functions that oscillate in response to food intake. Although liver and gut microbiome crosstalk has been reported, microbiome-mediated effects on peripheral circadian clocks and their output genes are less well known. Here, we report that germ-free (GF) mice display altered daily oscillation of clock gene expression with a concomitant change in the expression of clock output regulators. Mice exposed to microbes typically exhibit characterized activities of nuclear receptors, some of which (PPARα, LXRβ) regulate specific liver gene expression networks, but these activities are profoundly changed in GF mice. These alterations in microbiome-sensitive gene expression patterns are associated with daily alterations in lipid, glucose, and xenobiotic metabolism, protein turnover, and redox balance, as revealed by hepatic metabolome analyses. Moreover, at the systemic level, daily changes in the abundance of biomarkers such as HDL cholesterol, free fatty acids, FGF21, bilirubin, and lactate depend on the microbiome. Altogether, our results indicate that the microbiome is required for integration of liver clock oscillations that tune output activators and their effectors, thereby regulating metabolic gene expression for optimal liver function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The liver is a key organ of metabolic homeostasis with functions that oscillate in response to food intake. Although liver and gut microbiome crosstalk has been reported, microbiome-mediated effects on peripheral circadian clocks and their output genes are less well known. Here, we report that germ-free (GF) mice display altered daily oscillation of clock gene expression with a concomitant change in the expression of clock output regulators. Mice exposed to microbes typically exhibit characterized activities of nuclear receptors, some of which (PPARα, LXRβ) regulate specific liver gene expression networks, but these activities are profoundly changed in GF mice. These alterations in microbiome-sensitive gene expression patterns are associated with daily alterations in lipid, glucose, and xenobiotic metabolism, protein turnover, and redox balance, as revealed by hepatic metabolome analyses. Moreover, at the systemic level, daily changes in the abundance of biomarkers such as HDL cholesterol, free fatty acids, FGF21, bilirubin, and lactate depend on the microbiome. Altogether, our results indicate that the microbiome is required for integration of liver clock oscillations that tune output activators and their effectors, thereby regulating metabolic gene expression for optimal liver function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Focal epilepsy is increasingly recognized as the result of an altered brain network, both on the structural and functional levels and the characterization of these widespread brain alterations is crucial for our understanding of the clinical manifestation of seizure and cognitive deficits as well as for the management of candidates to epilepsy surgery. Tractography based on Diffusion Tensor Imaging allows non-invasive mapping of white matter tracts in vivo. Recently, diffusion spectrum imaging (DSI), based on an increased number of diffusion directions and intensities, has improved the sensitivity of tractography, notably with respect to the problem of fiber crossing and recent developments allow acquisition times compatible with clinical application. We used DSI and parcellation of the gray matter in regions of interest to build whole-brain connectivity matrices describing the mutual connections between cortical and subcortical regions in patients with focal epilepsy and healthy controls. In addition, the high angular and radial resolution of DSI allowed us to evaluate also some of the biophysical compartment models, to better understand the cause of the changes in diffusion anisotropy. Global connectivity, hub architecture and regional connectivity patterns were altered in TLE patients and showed different characteristics in RTLE vs LTLE with stronger abnormalities in RTLE. The microstructural analysis suggested that disturbed axonal density contributed more than fiber orientation to the connectivity changes affecting the temporal lobes whereas fiber orientation changes were more involved in extratemporal lobe changes. Our study provides further structural evidence that RTLE and LTLE are not symmetrical entities and DSI-based imaging could help investigate the microstructural correlate of these imaging abnormalities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Superior vena cava syndrome is defined by a set of signs and symptoms secondary to superior vena cava obstruction caused principally by malignant diseases. The present report describes the case of an unusual clinical manifestation of this syndrome with bilateral breast swelling, and emphasizes the relevance of knowledge on mammographic signs of systemic diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To evaluate the sonographic measurement of subcutaneous and visceral fat in correlation with the grade of hepatic steatosis. Materials and Methods In the period from October 2012 to January 2013, 365 patients were evaluated. The subcutaneous and visceral fat thicknesses were measured with a convex, 3–4 MHz transducer transversely placed 1 cm above the umbilical scar. The distance between the internal aspect of the abdominal rectus muscle and the posterior aortic wall in the abdominal midline was considered for measurement of the visceral fat. Increased liver echogenicity, blurring of vascular margins and increased acoustic attenuation were the parameters considered in the quantification of hepatic steatosis. Results Steatosis was found in 38% of the study sample. In the detection of moderate to severe steatosis, the area under the ROC curve was 0.96 for women and 0.99 for men, indicating cut-off values for visceral fat thickness of 9 cm and 10 cm, respectively. Conclusion The present study evidenced the correlation between steatosis and visceral fat thickness and suggested values for visceral fat thickness to allow the differentiation of normality from risk for steatohepatitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To compare automatic and manual measurements of intima-media complex (IMC) in common carotid, common femoral and right subclavian arteries of HIV-infected patients in relation to a control group, taking into consideration the classical risk factors for atherosclerosis. Materials and Methods The study sample comprised 70 HIV-infected patients and 70 non-HIV-infected controls paired according sex and age. Automatic (gold standard) and manual measurements of IMC were performed in the carotid arteries. Manual measurements were also performed in common femoral and right subclavian arteries. Bland-Altman graphs were utilized in the comparison and the adopted level significance was 5%. Results Intima-media complex alterations were not observed in any of the individuals as the mean automatic measurement in the right common carotid (RCC) artery was considered as the gold standard. As the gold standard was compared with the manual measurements (mean, maximum and minimum), no clinically significant alteration was observed. As the gold standard was compared with other sites, the difference was statistically and clinically significant at the origin of right subclavian artery (RCC: 0.51 mm vs. 0.91 mm) (p < 0.001). Conclusion HIV-infected individuals are not at higher risk for atherosclerosis than the control population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Complications from central venous catheterization include infectious conditions, pneumothorax, hemothorax and venous thrombosis. Pericardial effusion with cardiac tamponade hardly occurs, and in infants is generally caused by umbilical catheterization. The authors describe the case of cardiac tamponade occurred in an infant during chest computed tomography with contrast infusion through a central venous catheter inserted into the right internal jugular vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The authors report a case of umbilical venous catheter malposition with air in the portal venous system in a preterm neonate. Initially, the hypothesis of necrotizing enterocolitis was considered, but the newborn progressed with no finding of disease and the air disappeared at follow-up radiography. The differential diagnosis of such a finding can avoid unnecessary clinical treatments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relatamos um caso de paciente do sexo feminino, 48 anos, com quadro clínico de dor abdominal de moderada intensidade e abaulamento do abdome. Ao exame físico constatou-se massa abdominal palpável. A tomografia computadorizada mostrou volumosa massa retroperitoneal, com realce heterogêneo e íntima relação com a veia cava inferior. Realizou-se ressecção em bloco da massa e do segmento invadido da veia cava. A histologia revelou leiomiossarcoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractObjective:The present article is aimed at reporting the author’s experience with transcatheter arterial embolization using a lipiodol-ethanol mixture in three cases of unresectable symptomatic giant hepatic hemangiomas.Materials and Methods:The cases of three patients with giant unresectable symptomatic hepatic hemangiomas embolized in the period 2009–2010 were retrospectively reviewed. In all the cases, transarterial embolization was performed with an ethanol-lipiodol mixture.Results:Symptoms regression and quality of life improvement were observed in all the cases. No complications were observed and all the patients were discharged within 12 hours after the procedure.Conclusion:Transcatheter arterial embolization using ethanol mixed with lipiodol was a safe and effective treatment for symptomatic giant hepatic hemangiomas in this small series of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Adjusting behavior following the detection of inappropriate actions allows flexible adaptation to task demands and environmental contingencies during goal-directed behaviors. Post-error behavioral adjustments typically consist in adopting more cautious response mode, which manifests as a slowing down of response speed. Although converging evidence involves the dorsolateral prefrontal cortex (DLPFC) in post-error behavioral adjustment, whether and when the left or right DLPFC is critical for post-error slowing (PES), as well as the underlying brain mechanisms, remain highly debated. To resolve these issues, we used single-pulse transcranial magnetic stimulation in healthy human adults to disrupt the left or right DLPFC selectively at various delays within the 30-180ms interval following false alarms commission, while participants preformed a standard visual Go/NoGo task. PES significantly increased after TMS disruption of the right, but not the left DLPFC at 150ms post-FA response. We discuss these results in terms of an involvement of the right DLPFC in reducing the detrimental effects of error detection on subsequent behavioral performance, as opposed to implementing adaptative error-induced slowing down of response speed.