940 resultados para indirect quantification


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study is reported that examines the effect of caffeine consumption on majority and minority influence. In a double blind procedure, 72 participants consumed an orange drink, which either contained caffeine (3.5mg per kilogram of body weight) or did not (placebo). After a 40-minute delay, participants read a counter-attitudinal message (antivoluntary euthanasia) endorsed by either a numerical majority or minority. Both direct (message issue, i.e., voluntary euthanasia) and indirect (message issue-related, i.e., abortion) change was assessed by attitude scales completed before and after exposure to the message. In the placebo condition, the findings replicated the predictions of Moscovici's (1980) conversion theory; namely, majorities leading to compliance (direct influence) and minorities leading to conversion (indirect influence). When participants had consumed caffeine, majorities not only led to more direct influence than in the placebo condition but also to indirect influence. Minorities, by contrast, had no impact on either level of influence. The results suggest that moderate levels of caffeine increase systematic processing of the message but the consequences of this vary for each source. When the source is a majority there was increased indirect influence while for a minority there was decreased indirect influence. The results show the need to understand how contextual factors can affect social influence processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct quadrupole ICP-MS technique has been developed for the analysis of the rare earth elements and yttrium in natural waters. The method has been validated by comparison of the results obtained for the river water reference material SLRS-4 with literature values. The detection limit of the technique was investigated by analysis of serial dilutions of SLRS-4 and revealed that single elements can be quantified at single-digit fg/g concentrations. A coherent normalised rare earth pattern was retained at concentrations two orders of magnitude below natural concentrations for SLRS-4, demonstrating the excellent inter-element accuracy and precision of the method. The technique was applied to the analysis of a diluted mid-salinity estuarine sample, which also displayed a coherent normalised rare earth element pattern, yielding the expected distinctive marine characteristics. (c) 2006 Published by Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To rapidly quantify hepatitis B virus (HBV) DNA by real-time PCR using efficient TaqMan probe and extraction methods of virus DNA. Methods: Three standards were prepared by cloning PCR products which targeted S, C and X region of HBV genome into pGEM-T vector respectively. A pair of primers and matched TaqMan probe were selected by comparing the copy number and the Ct values of HBV serum samples derived from the three different standard curves using certain serum DNA. Then the efficiency of six HBV DNA extraction methods including guanidinium isothiocyanate, proteinase K, NaI, NaOH lysis, alkaline lysis and simple boiling was analyzed in sample A, B and C by real-time PCR. Meanwhile, 8 clinical HBV serum samples were quantified. Results: The copy number of the same HBV serum sample originated from the standard curve of S, C and X regions was 5.7 × 104/ mL, 6.3 × 102/mL and 1.6 × 103/mL respectively. The relative Ct value was 26.6, 31.8 and 29.5 respectively. Therefore, primers and matched probe from S region were chosen for further optimization of six extraction methods. The copy number of HBV serum samples A, B and C was 3.49 × 109/mL, 2.08 × 106/mL and 4.40 × 107/mL respectively, the relative Ct value was 19.9, 30 and 26.2 in the method of NaOH lysis, which was the efficientest among six methods. Simple boiling showed a slightly lower efficiency than NaOH lysis. Guanidinium isothiocyanate, proteinase K and NaI displayed that the copy number of HBV serum sample A, B and C was around 105/ mL, meanwhile the Ct value was about 30. Alkaline failed to quantify the copy number of three HBV serum samples, Standard deviation (SD) and coefficient variation (CV) were very low in all 8 clinical HBV serum samples, showing that quantification of HBV DNA in triplicate was reliable and accurate. Conclusion: Real-time PCR based on optimized primers and TaqMan probe from S region in combination with NaOH lysis is a simple, rapid and accurate method for quantification of HBV serum DNA. © 2006 The WJG Press. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Performance prediction models for partial face mechanical excavators, when developed in laboratory conditions, depend on relating the results of a set of rock property tests and indices to specific cutting energy (SE) for various rock types. There exist some studies in the literature aiming to correlate the geotechnical properties of intact rocks with the SE, especially for massive and widely jointed rock environments. However, those including direct and/or indirect measures of rock fracture parameters such as rock brittleness and fracture toughness, along with the other rock parameters expressing different aspects of rock behavior under drag tools (picks), are rather limited. With this study, it was aimed to investigate the relationships between the indirect measures of rock brittleness and fracture toughness and the SE depending on the results of a new and two previous linear rock cutting programmes. Relationships between the SE, rock strength parameters, and the rock index tests have also been investigated in this study. Sandstone samples taken from the different fields around Ankara, Turkey were used in the new testing programme. Detailed mineralogical analyses, petrographic studies, and rock mechanics and rock cutting tests were performed on these selected sandstone specimens. The assessment of rock cuttability was based on the SE. Three different brittleness indices (B1, B2, and B4) were calculated for sandstones samples, whereas a toughness index (T-i), being developed by Atkinson et al.(1), was employed to represent the indirect rock fracture toughness. The relationships between the SE and the large amounts of new data obtained from the mineralogical analyses, petrographic studies, rock mechanics, and linear rock cutting tests were evaluated by using bivariate correlation and curve fitting techniques, variance analysis, and Student's t-test. Rock cutting and rock property testing data that came from well-known studies of McFeat-Smith and Fowell(2) and Roxborough and Philips(3) have also been employed in statistical analyses together with the new data. Laboratory tests and subsequent analyses revealed that there were close correlations between the SE and B4 whereas no statistically significant correlation has been found between the SE and T-i. Uniaxial compressive and Brazilian tensile strengths and Shore scleroscope hardness of sandstones also exhibited strong relationships with the SE. NCB cone indenter test had the greatest influence on the SE among the other engineering properties of rocks, confirming the previous studies in rock cutting and mechanical excavation. Therefore, it was recommended to employ easy-to-use index tests of NCB cone indenter and Shore scleroscope in the estimation of laboratory SE of sandstones ranging from very low to high strengths in the absence of a rock cutting rig to measure it until the easy-to-use universal measures of the rock brittleness and especially the rock fracture toughness, being an intrinsic rock property, are developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite wide application of cellulose-azure as a substrate for measuring cellulase activity, there is no quantification of hydrolysis rate or enzymatic activities using this substrate. The aim of this study was to quantify the hydrolysis rate in terms of product formation and dye released using cellulose-azure. The amount of dye released was correlated with the production of glucose and the enzyme concentrations. It is shown that the lack of correlation can be due to (1) repression of the release of the azure-dye when azure-dye accumulates, (2) presence of degradable substrates in the cellulase powder which inflate the glucose measurements and (3) the degradation of cellulose which is not linked to the dye in the cellulose-azure. Based on the lack of correlation, it is recommended that cellulose-azure should only be applied in assays when the aim is to compare relative activities of different enzymatic systems. (c) 2005 Elsevier B.V. All rights reserved.