998 resultados para indirect mapping


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this working paper we discuss current attempts to engage communities in planning policy formulation in the UK. In particular we focus on the preparation of Community Strategies (CS) in England to inform local public policy and the wider proposals recently published by the UK government to move towards enhanced community engagement in planning (DTLR, 2001). We discuss how such strategies could be operationalised with a conceptual framework developed following ideas derived from ANT (cf. Murdoch, 1997, 1998; Selman, 2000; Parker & Wragg, 1999; Callon, 1986, 1998) and the ‘capitals’ literature (Lin, 2002; Fine, 2001; Selman, 2000; Putnam, 1993). We see this as an expression of neo-pragmatic planning theory, (Hoch, 1996; Stein & Harper, 2000) to develop a form of ‘pre-plan mapping’.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Density Functional Theory (DFT) has been used with an empirically-derived correction for the wavenumbers of vibrational band positions to predict the infrared spectra of several fluorinated esters (FESs). Radiative efficiencies (REs) were then determined using the method of Pinnock et al. and these were used with atmospheric lifetimes from the literature to determine the direct global warming potentials of FESs. FESs, in particular fluoroalkylacetates, alkylfluoroacetates and fluoroalkylformates, are potential greenhouse gases and their likely long atmospheric lifetimes and relatively large REs, compared to their parent HFEs, make them active contributors to global warming. Here, we use the concept of indirect global warming potential (indirect GWP) to assess the contribution to the warming of several commonly used HFEs emitted from the Earth's surface, explicitly taking into account that these HFEs will be converted into the corresponding FESs in the troposphere. The indirect GWP can be calculated using the radiative efficiencies and lifetimes of the HFE and its degradation FES products. We found that the GWPs of those studied HFEs which have the smallest direct GWP can be increased by 100-1600% when taking account of the cumulative effect due to the secondary FESs formed during HFE atmospheric oxidation. This effect may be particularly important for non-segregated HFEs and some segregated HFEs, which may contribute significantly more to global warming than can be concluded from examination of their direct GWPs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The cell catalysts calnexin (CNX) and protein-disulfide isomerase (PDI) cooperate in establishing the disulfide bonding of the HIV envelope (Env) glycoprotein. Following HIV binding to lymphocytes, cell-surface PDI also reduces Env to induce the fusogenic conformation. We sought to define the contact points between Env and these catalysts to illustrate their potential as therapeutic targets. In lysates of Env-expressing cells, 15% of the gp160 precursor, but not gp120, coprecipitated with CNX, whereas only 0.25% of gp160 and gp120 coprecipitated with PDI. Under in vitro conditions, which mimic the Env/PDI interaction during virus/cell contact, PDI readily associated with Env. The domains of Env interacting in cellulo with CNX or in vitro with PDI were then determined using anti-Env antibodies whose binding site was occluded by CNX or PDI. Antibodies against domains V1/V2, C2, and the C terminus of V3 did not bind CNX-associated Env, whereas those against C1, V1/V2, and the CD4-binding domain did not react with PDI-associated Env. In addition, a mixture of the latter antibodies interfered with PDI-mediated Env reduction. Thus, Env interacts with intracellular CNX and extracellular PDI via discrete, largely nonoverlapping, regions. The sites of interaction explain the mode of action of compounds that target these two catalysts and may enable the design of further new competitive agents.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Infections involving Salmonella enterica subsp. enterica serovars have serious animal and human health implications; causing gastroenteritis in humans and clinical symptoms, such as diarrhoea and abortion, in livestock. In this study an optical genetic mapping technique was used to screen 20 field isolate strains from four serovars implicated in disease outbreaks. The technique was able to distinguish between the serovars and the available sequenced strains and group them in agreement with similar data from microarrays and PFGE. The optical maps revealed variation in genome maps associated with antimicrobial resistance and prophage content in S. Typhimurium, and separated the S. Newport strains into two clear geographical lineages defined by the presence of prophage sequences. The technique was also able to detect novel insertions that may have had effects on the central metabolism of some strains. Overall optical mapping allowed a greater level of differentiation of genomic content and spatial information than more traditional typing methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated whether children’s fears could be un-learned using Rachman’s indirect pathways for learning fear. We hypothesised that positive information and modelling a non-anxious response are effective methods of un-learning fears acquired through verbal information. One hundred and seven children aged 6–8 years received negative information about one animal and no information about another. Fear beliefs and behavioural avoidance were measured. Children were randomised to receive positive verbal information, modelling, or a control task. Fear beliefs and behavioural avoidance were measured again. Positive information and modelling led to lower fear beliefs and behavioural avoidance than the control condition. Positive information was more effective than modelling in reducing fear beliefs and both methods significantly reduced behavioural avoidance. The results support Rachman’s indirect pathways as viable fear un-learning pathways and supports associative learning theories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Department of Health staff wished to use systems modelling to discuss acute patient flows with groups of NHS staff. The aim was to assess the usefulness of system dynamics (SD) in a healthcare context and to elicit proposals concerning ways of improving patient experience. Since time restrictions excluded simulation modelling, a hybrid approach using stock/flow symbols from SD was created. Initial interviews and hospital site visits generated a series of stock/flow maps. A ‘Conceptual Framework’ was then created to introduce the mapping symbols and to generate a series of questions about different patient paths and what might speed or slow patient flows. These materials formed the centre of three workshops for NHS staff. The participants were able to propose ideas for improving patient flows and the elicited data was subsequently employed to create a finalized suite of maps of a general acute hospital. The maps and ideas were communicated back to the Department of Health and subsequently assisted the work of the Modernization Agency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, numerical analyses of the thermal performance of an indirect evaporative air cooler incorporating a M-cycle cross-flow heat exchanger has been carried out. The numerical model was established from solving the coupled governing equations for heat and mass transfer between the product and working air, using the finite-element method. The model was developed using the EES (Engineering Equation Solver) environment and validated by published experimental data. Correlation between the cooling (wet-bulb) effectiveness, system COP and a number of air flow/exchanger parameters was developed. It is found that lower channel air velocity, lower inlet air relative humidity, and higher working-to-product air ratio yielded higher cooling effectiveness. The recommended average air velocities in dry and wet channels should not be greater than 1.77 m/s and 0.7 m/s, respectively. The optimum flow ratio of working-to-product air for this cooler is 50%. The channel geometric sizes, i.e. channel length and height, also impose significant impact to system performance. Longer channel length and smaller channel height contribute to increase of the system cooling effectiveness but lead to reduced system COP. The recommend channel height is 4 mm and the dimensionless channel length, i.e., ratio of the channel length to height, should be in the range 100 to 300. Numerical study results indicated that this new type of M-cycle heat and mass exchanger can achieve 16.7% higher cooling effectiveness compared with the conventional cross-flow heat and mass exchanger for the indirect evaporative cooler. The model of this kind is new and not yet reported in literatures. The results of the study help with design and performance analyses of such a new type of indirect evaporative air cooler, and in further, help increasing market rating of the technology within building air conditioning sector, which is currently dominated by the conventional compression refrigeration technology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper provides a comparative study of the performance of cross-flow and counter-flow M-cycle heat exchangers for dew point cooling. It is recognised that evaporative cooling systems offer a low energy alternative to conventional air conditioning units. Recently emerged dew point cooling, as the renovated evaporative cooling configuration, is claimed to have much higher cooling output over the conventional evaporative modes owing to use of the M-cycle heat exchangers. Cross-flow and counter-flow heat exchangers, as the available structures for M-cycle dew point cooling processing, were theoretically and experimentally investigated to identify the difference in cooling effectiveness of both under the parallel structural/operational conditions, optimise the geometrical sizes of the exchangers and suggest their favourite operational conditions. Through development of a dedicated computer model and case-by-case experimental testing and validation, a parametric study of the cooling performance of the counter-flow and cross-flow heat exchangers was carried out. The results showed the counter-flow exchanger offered greater (around 20% higher) cooling capacity, as well as greater (15%–23% higher) dew-point and wet-bulb effectiveness when equal in physical size and under the same operating conditions. The cross-flow system, however, had a greater (10% higher) Energy Efficiency (COP). As the increased cooling effectiveness will lead to reduced air volume flow rate, smaller system size and lower cost, whilst the size and cost are the inherent barriers for use of dew point cooling as the alternation of the conventional cooling systems, the counter-flow system is considered to offer practical advantages over the cross-flow system that would aid the uptake of this low energy cooling alternative. In line with increased global demand for energy in cooling of building, largely by economic booming of emerging developing nations and recognised global warming, the research results will be of significant importance in terms of promoting deployment of the low energy dew point cooling system, helping reduction of energy use in cooling of buildings and cut of the associated carbon emission.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Very high-resolution Synthetic Aperture Radar sensors represent an alternative to aerial photography for delineating floods in built-up environments where flood risk is highest. However, even with currently available SAR image resolutions of 3 m and higher, signal returns from man-made structures hamper the accurate mapping of flooded areas. Enhanced image processing algorithms and a better exploitation of image archives are required to facilitate the use of microwave remote sensing data for monitoring flood dynamics in urban areas. In this study a hybrid methodology combining radiometric thresholding, region growing and change detection is introduced as an approach enabling the automated, objective and reliable flood extent extraction from very high-resolution urban SAR images. The method is based on the calibration of a statistical distribution of “open water” backscatter values inferred from SAR images of floods. SAR images acquired during dry conditions enable the identification of areas i) that are not “visible” to the sensor (i.e. regions affected by ‘layover’ and ‘shadow’) and ii) that systematically behave as specular reflectors (e.g. smooth tarmac, permanent water bodies). Change detection with respect to a pre- or post flood reference image thereby reduces over-detection of inundated areas. A case study of the July 2007 Severn River flood (UK) observed by the very high-resolution SAR sensor on board TerraSAR-X as well as airborne photography highlights advantages and limitations of the proposed method. We conclude that even though the fully automated SAR-based flood mapping technique overcomes some limitations of previous methods, further technological and methodological improvements are necessary for SAR-based flood detection in urban areas to match the flood mapping capability of high quality aerial photography.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper charts the current evidence on effectiveness of different anti-corruption reforms, and identifies significant evidence gaps. Despite a substantial amount of literature on corruption, this review found very few studies focusing on anti-corruption reforms, and even fewer that credibly assess issues of effectiveness and impact. The evidence was strong for only two types of interventions: public financial management (PFM) reforms and supreme audit institutions (SAIs). For PFM, the evidence in general showed positive results, whereas the effectiveness was mixed for SAIs. No strong evidence indicates that any of the interventions pursued have been ineffective, but there is fair evidence that anti-corruption authorities, civil service reforms and the use of corruption conditionality in aid allocation decisions in general have not been effective. The paper advocates more operationally-relevant research and rigorous evaluations to build up the missing evidence base, particularly in conflict-afflicted states, in regards to the private sector, and on the interactions and interdependencies between different anti-corruption interventions.