1000 resultados para determinação de sódio


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to use colorimetric assays for hydroxamic acid to quantify the biodiesel content in diesel and compare it with the traditional method (infrared spectroscopy, using the EN 14078 method). Samples were prepared from B2 to B10 with two kinds of diesel - S500 (red) and S50 (yellow) - to obtain two calibration curves. Through statistical methods it was shown that the slopes of the straight lines obtained for the different types of diesel were the same. Thus, the type of diesel did not influence the results of the colorimetric assay for hydroxamic acid. Real samples collected from gas stations were analyzed by both methods (colorimetry and EN 14078). By applying Student's t-test it was concluded that the methods could be considered statistically equivalent. Therefore, it was confirmed that the colorimetric assay for hydroxamic acid is suitable for detecting and quantifying the content of biodiesel in biodiesel/diesel blends and can also be easily adapted to field analyses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple procedure for ultrasound-assisted extraction and colorimetric determination of iron in soil samples was developed. The iron concentration in the analyzed samples was determined by the colorimetric method and the results compared with inductively coupled plasma mass spectrometry (ICP-MS). Fifteen soil samples were analyzed and the iron concentration results compared with those obtained by ICP-MS using microwave-assisted sample digestion. The proposed procedure showed good efficiency for iron extraction and the results obtained by colorimetric determination exhibited good agreement with ICP-MS. Moreover, ultrasound-assisted extraction and colorimetric determination is a simple, fast and low-cost procedure for application in routine analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractThis work describes the development of a biosensor based on the tyrosinase enzyme (Tyr) for the determination of phenol (PHEN) in laboratory effluent samples derived from ammoniacal nitrogen analysis of the water samples from the Muquém dam in the city of Cariús, CE, using square-wave voltammetry (SWV). The electrode modification consisted of the immobilization of gold nanoparticles, multi-walled carbon nanotubes, cobalt phthalocyanine, and Tyr on a glassy carbon electrode. The electrolyte, pH, enzyme quantity, and voltammetric parameters were optimized to detect PHEN. The analytical curves presented a linear range from 4.97 × 10-6 mol L-1 to 6.10 × 10-5 mol L-1, and the detection limit (DL) and quantitation limit (QL) values were 4.81 × 10-6 mol L-1 and 4.97 × 10-6mol L-1, respectively. The repetition of measurements with the same biosensor and repetition for three other prepared biosensors exhibited a relative standard deviation (RSD) of 5.50 and 1.75%, respectively. The percentage recovery of PHEN in effluent samples varied from 86.40 to 105.04%. The stability of the biosensor was evaluated (at 21 days) with satisfactory results, showing 97.86% of the initial response. Moreover, the DL and recovery percentages agreed with the established values from CONAMA and ABNT, respectively. Thus, the electrode configuration developed seems a promising tool in the detection and quantification of PHEN in complex samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractMany well-established methods for determining the antioxidant capacities in several samples have been described in literature. However, DPPH (2,2-diphenyl-1-picrylhydrazyl) and ABTS (2,2'-azino-bis(3-ethylbenzothiazoline-6-sulphonic acid)) are the main two methods that utilize radicals as spectrophotometric probes for analysis. Nevertheless, these methods have certain limitations because of their slower kinetics, solvent polarity effects, the hydrophilicity and lipophilicity of the compounds, chemical costs, etc. In this study, a spectrophotometric method for determining the antioxidant capacity in beverages was developed based on an exploration of the cation radical derived from DEPD. This method was based on the oxidation of aromatic amines with Fe(III) ions at pH 4.0, which leads to their corresponding purple cation radicals (DEPD•+) with λmax values at 500 and 540 nm. The addition of an antioxidant after the formation of the radical leads to a reduction in color intensity that is proportional to the antioxidant concentration in the medium. Results obtained using this method were compared with the Folin-Ciocalteau, ABTS and DPPH methods in terms of applications in wines, teas, and infusions samples. Linear correlation analysis at a 95% confidence level was employed to compare the results, which were in good agreement with a correlation coefficient of r > 0.9000. Thus, the developed method was simple, accurate, and consistent with other assays for the determination of the total amount of phenolic compounds and antioxidant capacity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzymatic spectrophotometric method for the determination of methyldopa in a dissolution test of tablets was developed using peroxidase from radish (Raphanus sativus). The enzyme was extracted from radish roots using a phosphate buffer of pH 6.5 and partially purified through centrifugation. The supernatant was used as a source of peroxidase. The methyldopachrome resulting from the oxidation of methyldopa catalyzed by peroxidase was monitored at 480 nm. The enzymatic activity was stable for a period of at least 25 days when the extract was stored at 4 or -20 ºC. The method was validated according to RDC 899 and ICH guidelines. The calibration graph was linear in the range 200-800 µg mL-1, with a correlation coefficient of 0.9992. The limits of detection and quantification in the dissolution medium were 36 and 120 µg mL-1, respectively. Recovery was greater than 98.9%. This method can be applied for the determination of methyldopa in dissolution tests of tablets without interference from the excipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two simple and efficient procedures have been developed for the rapid simultaneous determination of compounds with mutual spectral interference (rifampicin (RIF) and isoniazid (INH)). The first method was based on the UV–Vis spectral signal (190–600 nm) of synthetic RIF and INH aqueous solutions, whereas the second method involved the visible spectral signal registered between 350 and 800 nm after the reaction of INH with a Cu2+/neocuproine complex. Both multivariate spectrophotometric methods show excellent prevision capacity, providing results that are statistically equivalent with those provided by the standard chromatographic procedure. The methods were validated according to criteria established by ANVISA, showing precision, accuracy and robustness compatible with the requirements for new analytical methods, additionally allowing the reduction of waste generation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this study, we report the preparation of a new tetra-substituted epoxide aldehyde cyclopentane, which acts as a starting material for the synthesis of plinol, from (R)-(+)-epoxy-limonene. The synthesis was performed in three steps and resulted in a good yield. The structural determination was performed by 1H and 13C NMR, and the relative stereochemistry was defined by nuclear Overhauser effect (NOE) experiments with computer calculations of molecular modeling, particularly with respect to indirect coupling constant calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Liquid chromatography is often used for the determination of pesticide multiresidues in foods. In Brazil, the strawberry crop is an example of a food with high levels of irregularities because of the application of pesticides. This is a major concern from the perspective of food safety, environmental protection, and certification for food export. The purpose of this study is to evaluate and compare chromatographic separation and detection methods in relation to a newly developed and validated method using ultra high performance liquid chromatography (LC) coupled with tandem mass spectrometry (MS/MS) for the analytical determination of pesticides in strawberries. The comparisons were based on evaluations of the analysis time, consumption of the solvent in the mobile phase, injection volume, detectability, matrix effect, and recovery. The results showed that the LC–MS/MS and UHPLC–MS/MS techniques were both extremely efficient at analyzing pesticide residues with different physico-chemical parameters that were present at low concentrations in a complex matrix. The UHPLC separation method provided better chromatographic performance and productivity, which contributed favorably to routine analytical determinations. Detection by MS/MS had better detectability and selectivity compared with the diode array detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a comparative study between the procedures of deconvolution and the second-order derivative of square wave voltammograms to achieve separation of the voltammetric peaks of levofloxacin (LEVO) and norfloxacin (NOR), for their simultaneous quantification in urine samples. The obtained results indicate that the use of second-derivative voltammograms coupled with carbon screen-printed electrodes is the most efficient approach for completely separating the voltammetric peaks of LEVO and NOR. In addition, this approach has produced detection limits lower than 1.0 µmol L-1 and a wide linear range for both drugs. The proposed method was successfully used to simultaneously determine LEVO and NOR in spiked human and bovine urine samples with recovery percentages close to 100% for all analyzed samples.