997 resultados para dental impression


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To evaluate the adherence of Streptococcus mutans to the surface of the amalgam and copper/aluminum alloy samples and also evaluate the release of metallic ions. METHODS: The prepared medium was changed every 72 h and analyzed by atomic absorption spectrophotometer. Samples were removed from the prepared medium at 15, 30, 48 and 60 days. RESULTS: The result shows that ions released were statistically different among all groups, and so were both biofilm and pits formation and the corrosion induced by the S. mutans in both types of samples. SEM observation of the samples immersed in the prepared medium with S. mutans showed adherence of microorganisms on the whole surface, in all groups. CONCLUSIONS: The S. mutans adhere to both amalgam and copper/aluminum alloy causing corrosion of those restorations. S. mutans produced a greater ions release in Cu/Al alloy; in amalgam, the ions release was not influenced by exposure to S. mutans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To evaluate the dental development of Brazilian children and adolescents with cleft lip and palate. Methods: The sample consisted of 107 panoramic radiographs of children and adolescents with cleft lip and/or palate (cleft group) and 107 panoramic radiographs of children and adolescents without cleft lip and/or palate (control group), with chronological ages ranging from 6 to 15 years, matched in gender and chronological age within 60 days. Radiographs were digitized and masked and dental age was assessed using the method described by Demirjian et al. (1973). Three trained examiners conducted the assessments. Each examiner evaluated the radiographs three times. Data were statistically analyzed using non-parametric tests and univariate linear regression (p<0.05). Results: The dental age was overestimated in relation to the chronological age in both groups (p<0.0001). Compared to the control group, there was a delay in the dental age in the cleft group of 0.17 years (2.1 months). However, no statistically significant difference in the dental age between the cleft and the control group was found even when considering the different cleft types (p=0.152). Conclusions: There was no statistically significant difference in the dental age between the cleft and the control groups. The evaluation of dental development in individuals with cleft lip and palate should be approached in the same way as in individuals without clefts, with a focus on the individualization of diagnosis and treatment planning.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to assess by means of scanning electron microscopy (SEM) the remaining adhesive interface after debonding orthodontic attachments bonded to bovine teeth with the use of hydrophilic and hydrophobic primers under different dental substrate moisture conditions. MATERIAL AND METHODS: Twenty mandibular incisors were divided into four groups (n=5). In Group I, bracket bonding was performed with Transbond MIP hydrophilic primer and Transbond XT adhesive paste applied to moist substrate, and in Group II a bonding system comprising Transbond XT hydrophobic primer and adhesive paste was applied to moist substrate. Brackets were bonded to the specimens in Groups III and IV using the same adhesive systems, but on dry dental enamel. The images were qualitatively assessed by SEM. RESULTS: The absence of moisture in etched enamel enabled better interaction between bonding materials and the adamantine structure. The hydrophobic primer achieved the worst micromechanical interlocking results when applied to a moist dental structure, whereas the hydrophilic system proved versatile, yielding acceptable results in moist conditions and excellent interaction in the absence of contamination. CONCLUSION: The authors assert that the best condition for the application of primers to dental enamel occurs in the absence of moisture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the fracture resistance of simulated immature teeth after different intra-radicular treatments. Crowns and roots of bovine incisors were cut transversally and removed to simulate immature teeth. Root canal preparation and flaring were performed using a bur in crown-apex and apex-crown direction. The samples were distributed into 5 groups (n=10): Positive control (PoC) - no root canal flaring or filling; Negative control (NeC) - teeth were sectioned and their root canals were flared; Direct anatomical glass fiber post (RaP) - #2 Reforpost main glass fiber post relined with composite resin; Double tapered conical glass fiber posts (ExP) - #3 Exacto glass fiber post; and #2 Reforpost main glass fiber + Reforpin accessory glass fiber posts (RrP). In RaP, ExP and RrP, 4.0-mm apical plugs were done with MTA Angelus. The specimens were embedded in polystyrene resin inside cylinders and the periodontal ligament was simulated with a polyether-based impression material. The specimens were submitted to compressive fracture strength test (0.5 mm/min at 135° relative to the long axis of the tooth) in a servo-hydraulic mechanical testing machine MTS 810. Data were subjected to one-way ANOVA and Dunnett's C or Tukey's tests (α=0.05). The control groups (PoC and NeC) showed lower fracture strength than the experimental groups. NeC presented the lowest resistance and ExP presented the highest resistance among the experimental groups. The flaring procedures produced a detrimental effect on the fracture resistance of the bovine teeth. Glass fiber intra-radicular posts increased significantly the fracture resistance of simulated immature teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this systematic review was to identify clinical studies on implants placed in the tuberosity region to determine the survival rate of these implants when compared to implants placed in other regions of the maxilla. A search for data published up until March 2014 was undertaken using the PubMed, Cochrane Library, Embase, and ScienceDirect databases. Eligible studies were selected according to inclusion and exclusion criteria. The first database search revealed 310 titles. After inclusion and exclusion criteria were applied, five studies remained for the detailed analysis. A total of 113 patients were followed for a period of 6-144 months; 289 implants were placed in the patients evaluated. There were eight failures/losses of dental implants in the tuberosity region; the overall survival rate was 94.63% for these implants. In controlled studies, the cumulative survival rates for implants placed in the maxillary tuberosity and other maxillary regions were 96.1% and 95%, respectively. In conclusion, implants placed into the maxillary tuberosity are a predictable alternative for the treatment of patients with insufficient bone volume in the maxillary region. However, randomized trials are needed to assess the effectiveness of this treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)