970 resultados para Valve Repair


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Pulmonary valve insufficiency remains a leading cause for reoperations in congenital cardiac surgery. The current percutaneous approach is limited by the size of the access vessel and variable right ventricular outflow tract morphology. This study assesses the feasibility of transapical pulmonary valve replacement based on a new valved stent construction concept. METHODS: A new valved stent design was implanted off-pump under continuous intracardiac echocardiographic and fluoroscopic guidance into the native right ventricular outflow tract in 8 pigs (48.5 +/- 6.0 kg) through the right ventricular apex, and device function was studied by using invasive and noninvasive measures. RESULTS: Procedural success was 100% at the first attempt. Procedural time was 75 +/- 15 minutes. All devices were delivered at the target site with good acute valve function. No valved stents dislodged. No animal had significant regurgitation or paravalvular leaking on intracardiac echocardiographic analysis. All animals had a competent tricuspid valve and no signs of right ventricular dysfunction. The planimetric valve orifice was 2.85 +/- 0.32 cm(2). No damage to the pulmonary artery or structural defect of the valved stents was found at necropsy. CONCLUSIONS: This study confirms the feasibility of direct access valve replacement through the transapical procedure for replacement of the pulmonary valve, as well as validity of the new valved stent design concept. The transapical procedure is targeting a broader patient pool, including the very young and the adult patient. The device design might not be restricted to failing conduits only and could allow for implantation in a larger patient population, including those with native right ventricular outflow tract configurations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To retrospectively evaluate the safety and effectiveness of the use of bivalirudin, a direct thrombin antagonist, compared with unfractionated heparin in endovascular aneurysm repair (EVAR). MATERIALS AND METHODS: Between March 1994 and September 2007, 740 consecutive patients (mean age, 75.7 y +/- 7.7; 69 women) underwent elective EVAR for infrarenal abdominal aortic aneurysm. Bivalirudin was used in 98 of these 740 (13.2%) and unfractioned heparin was used in the other 642 (86.8%). Complications were classified according to the Society of Vascular Surgery/International Society for Cardiovascular Surgery criteria. Major bleeding was defined as clinically overt blood loss resulting in a decrease of hemoglobin of more than 3 g/dL, any decrease in hemoglobin of more than 4 g/dL, transfusion of 2 U or more of red blood cells, or intracranial or retroperitoneal hemorrhage. RESULTS: Grade 1 major complications were observed in 161 of 642 patients (25.2%) in the heparin group and 12 of 98 patients (12.2%) in the bivalirudin group (P = .0046), whereas the incidences of grade 3 major complications were not significantly different between groups (P = .57). The rate of total complications was higher in the heparin group than in the bivalirudin group (247 of 642 [38.5%] vs 21 of 98 [21.4%]; P = .001). Major bleeding occurred in 10 of 98 patients (10.2%) receiving bivalirudin and in 91 of 642 patients (14.2%) receiving heparin (P = .34). One of 21 major complications (4.76%) in the bivalirudin group and 12 of 247 major complications (4.86%) in the heparin group were attributable to thrombosis (P = 1.0). CONCLUSIONS: Bivalirudin is a safe and feasible alternative to unfractionated heparin in patients undergoing EVAR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Das RTeJournal möchte in seiner Rubrik:“ Repair“, Berichte aufnehmen, in denen die Reparatur oder der Ersatz von Bauteilen durch Additive Manufacturing (AM) Lösungen aufgenommen wird. Einmal als Anregung sich damit auseinander zu setzen und gleichzeitig auch als Dienstleistung beim Bedarf von Reparaturen. Es würde uns freuen, wenn Sie uns Beispiele mit einem kleinen Reparaturbericht zusenden könnten, die zum Einsatz von Additive Manufacturing führten. Email: eich@fh-aachen.de

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pasteurella species are part of the oral flora of cats and dogs. In humans, they are frequently found in infected animal bite wounds, but invasive infections are rare. This is the first report of prosthetic-valve endocarditis with a Pasteurella dagmatis-like species, which originated from the patient's cat.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Law collections pose some unique problems in terms of their physical care due to filing and updating practices, use patterns and special binding structures such as loose-leafs and pocket parts. This workshop is designed to address specific preservation needs of law collections through lecture, demonstration and hands-on opportunities. Participants will learn the fundamentals of book repair, treatment options and decision-making, and preservation best practices. Emphasis will be placed on moving knowledge into practice through guidelines for establishing institution-appropriate in house book repair programs, by training the trainers in basic book repair techniques and providing all participants with a start-up tool kit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: We aimed to assess the impact of B-type natriuretic peptide (BNP) on short-term outcomes in patients undergoing transcatheter aortic valve implantation (TAVI). Methods and results: Of 500 consecutive patients with severe aortic stenosis undergoing TAVI at our institution, we studied 340 patients who had a BNP assessment prior to TAVI. Patients were divided into tertiles - low: BNP ≤201 pg/mL (n=114), mid: BNP 202-595 pg/mL (n=113) and high: BNP ≥596 pg/mL (n=113). The primary endpoint was all-cause mortality, cardiac death and major adverse cardiac and cerebrovascular events (MACCE; death, major stroke and myocardial infarction) at 30 days. Compared with low tertile, high tertile patients were at higher baseline surgical risk (STS score 5.5±3.0 vs. 7.4±4.1, p=0.002). On echocardiography, high tertile patients had smaller valve areas (0.74±0.21 vs. 0.66±0.23 cm2, p=0.008), higher left ventricular (LV) mass indices (123.40±33.66 vs. 168.22±47.96 g/m2, p<0.001) and lower LV ejection fractions (61.59±7.18 vs. 42.65±15.41%, p<0.001) as compared with low tertile patients. At 30 days, a significantly higher incidence of death (hazard ratio [HR] 7.41, p=0.001) cardiac death (HR 5.82, p=0.006) and MACCE (HR 9.04, p<0.001) was observed among high as compared to low tertile patients. Conclusions: In TAVI patients, higher BNP values at baseline are associated with an increased risk for an adverse event periprocedurally and after 30 days, respectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To review the incidence, clinical presentation, definite management and 1-year outcome in patients with aorto-oesophageal fistulation (AOF) following thoracic endovascular aortic repair (TEVAR). METHODS International multicentre registry (European Registry of Endovascular Aortic Repair Complications) between 2001 and 2011 with a total caseload of 2387 TEVAR procedures (17 centres). RESULTS Thirty-six patients with a median age of 69 years (IQR 56-75), 25% females and 9 patients (19%) following previous aortic surgery were identified. The incidence of AOF in the entire cohort after TEVAR in the study period was 1.5%. The primary underlying aortic pathology for TEVAR was atherosclerotic aneurysm formation in 53% of patients and the median time to development of AOF was 90 days (IQR 30-150). Leading clinical symptoms were fever of unknown origin in 29 (81%), haematemesis in 19 (53%) and shock in 8 (22%) patients. Diagnosis could be confirmed via computed tomography in 92% of the cases with the leading sign of a new mediastinal mass in 28 (78%) patients. A conservative approach resulted in a 100% 1-year mortality, and 1-year survival for an oesophageal stenting-only approach was 17%. Survival after isolated oesophagectomy was 43%. The highest 1-year survival rate (46%) could be achieved via an aggressive treatment including radical oesophagectomy and aortic replacement [relative risk increase 1.73 95% confidence interval (CI) 1.03-2.92]. The survival advantage of this aggressive treatment modality could be confirmed in bootstrap analysis (95% CI 1.11-3.33). CONCLUSIONS The development of AOF is a rare but lethal complication after TEVAR, being associated with the need for emergency TEVAR as well as mediastinal haematoma formation. The only durable and successful approach to cure the disease is radical oesophagectomy and extensive aortic reconstruction. These findings may serve as a decision-making tool for physicians treating these complex patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The successes of thoracic endovascular aortic repair (TEVAR) have spurned new approaches to addressing thoracic aortic pathologies. These hybrid techniques offer an alternative in patients with multi-segmental thoracic aortic pathologies which would have otherwise required a two-step arch replacement and open descending arch repair. The following article offers a clinical insight to the available hybrid approaches, such as rerouting of supra-aortic vessels. Unique complications to endovascular repairs, and technical risks and issues, are also presented along with management options and strategies to minimize such concerns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Skeletal muscle complaints are a common consequence of cholesterol-lowering therapy. Transverse tubular (T-tubular) vacuolations occur in patients having statin-associated myopathy and, to a lesser extent, in statin-treated patients without myopathy. We have investigated quantitative changes in T-tubular morphology and looked for early indicators of T-tubular membrane repair in skeletal muscle biopsy samples from patients receiving cholesterol-lowering therapy who do not have myopathic side effects. Gene expression and protein levels of incipient membrane repair proteins were monitored in patients who tolerated statin treatment without myopathy and in statin-naive subjects. In addition, morphometry of the T-tubular system was performed. Only the gene expression for annexin A1 was up-regulated, whereas the expression of other repair genes remained unchanged. However, annexin A1 and dysferlin protein levels were significantly increased. In statin-treated patients, the volume fraction of the T-tubular system was significantly increased, but the volume fraction of the sarcoplasmic reticulum remained unchanged. A complex surface structure in combination with high mechanical loads makes skeletal muscle plasma membranes susceptible to injury. Ca(2+)-dependent membrane repair proteins such as dysferlin and annexin A1 are deployed at T-tubular sites. The up-regulation of annexin A1 gene expression and protein points to this protein as a biomarker for T-tubular repair.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In a patient with staphylococcus lugdunensis prosthetic aortic valve endocarditis and coronary septic embolism accompanied by antero-lateral myocardial infarction, embolic material was successfully aspirated from the bifurcation of the left anterior descending coronary artery and the first diagonal branch. A good angiographic result was documented six months thereafter when the patient presented with a second complication, pulsatile compression of the left main coronary artery by an abscess cavity originating between the aortic and mitral annulus, leading to congestive heart failure. The patient underwent successful surgical replacement of the aortic valve prosthesis with concomitant patch reconstruction of the annulus as well as tricuspid annuloplasty.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy. BACKGROUND Since its commercialization in 2007, the number of TAVR procedures has grown exponentially. METHODS The adoption of TAVR was investigated in 11 European countries: Germany, France, Italy, United Kingdom, Spain, the Netherlands, Switzerland, Belgium, Portugal, Denmark, and Ireland. Data were collected from 2 sources: 1) lead physicians submitted nation-specific registry data; and 2) an implantation-based TAVR market tracker. Economic indexes such as healthcare expenditure per capita, sources of healthcare funding, and reimbursement strategies were correlated to TAVR use. Furthermore, we assessed the extent to which TAVR has penetrated its potential patient population. RESULTS Between 2007 and 2011, 34,317 patients underwent TAVR. Considerable variation in TAVR use existed across nations. In 2011, the number of TAVR implants per million individuals ranged from 6.1 in Portugal to 88.7 in Germany (33 ± 25). The annual number of TAVR implants performed per center across nations also varied widely (range 10 to 89). The weighted average TAVR penetration rate was low: 17.9%. Significant correlation was found between TAVR use and healthcare spending per capita (r = 0.80; p = 0.005). TAVR-specific reimbursement systems were associated with higher TAVR use than restricted systems (698 ± 232 vs. 213 ± 112 implants/million individuals ≥ 75 years; p = 0.002). CONCLUSIONS The authors' findings indicate that TAVR is underutilized in high and prohibitive surgical risk patients with severe aortic stenosis. National economic indexes and reimbursement strategies are closely linked with TAVR use and help explain the inequitable adoption of this therapy.