992 resultados para VESSEL PHANTOM


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The optimal strategy for percutaneous coronary intervention (PCI) of ST-segment elevation myocardial infarction (STEMI) in multi-vessel disease (MVD), i.e., multi-vessel PCI (MV-PCI) vs. PCI of the infarct-related artery only (IRA-PCI), still remains unknown. METHODS: Patients of the AMIS Plus registry admitted with an acute coronary syndrome were contacted after a median of 378 days (interquartile range 371-409). The primary end-point was all-cause death. The secondary end-point included all major adverse cardiovascular and cerebrovascular events (MACCE) including death, re-infarction, re-hospitalization for cardiac causes, any cardiac re-intervention, and stroke. RESULTS: Between 2005 and 2012, 8330 STEMI patients were identified, of whom 1909 (24%) had MVD. Of these, 442 (23%) received MV-PCI and 1467 (77%) IRA-PCI. While all-cause mortality was similar in both groups (2.7% both, p>0.99), MACCE was significantly lower after MV-PCI vs. IRA-PCI (15.6% vs. 20.0%, p=0.038), mainly driven by lower rates of cardiac re-hospitalization and cardiac re-intervention. Patients undergoing MV-PCI with drug-eluting stents had lower rates of all-cause mortality (2.1% vs. 7.4%, p=0.026) and MACCE (14.1% vs. 25.9%, p=0.042) compared with those receiving bare metal stents (BMS). In multivariate analysis, MV-PCI (odds ratio, OR 0.69, 95% CI 0.51-0.93, p=0.017) and comorbidities (Charlson index ≥ 2; OR 1.42, 95% CI 1.05-1.92, p=0.025) were independent predictors for 1-year MACCE. CONCLUSION: In an unselected nationwide real-world cohort, an approach using immediate complete revascularization may be beneficial in STEMI patients with MVD regarding MACCE, specifically when drug-eluting stents are used, but not regarding mortality. This has to be tested in a randomized controlled trial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A T(2) magnetization-preparation (T(2) Prep) sequence is proposed that is insensitive to B(1) field variations and simultaneously provides fat suppression without any further increase in specific absorption rate (SAR). Increased B(1) inhomogeneity at higher magnetic field strength (B(0) > or = 3T) necessitates a preparation sequence that is less sensitive to B(1) variations. For the proposed technique, T(2) weighting in the image is achieved using a segmented B(1)-insensitive rotation (BIR-4) adiabatic pulse by inserting two equally long delays, one after the initial reverse adiabatic half passage (AHP), and the other before the final AHP segment of a BIR-4 pulse. This sequence yields T(2) weighting with both B(1) and B(0) insensitivity. To simultaneously suppress fat signal (at the cost of B(0) insensitivity), the second delay is prolonged so that fat accumulates additional phase due to its chemical shift. Numerical simulations as well as phantom and in vivo image acquisitions were performed to show the efficacy of the proposed technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Comment on : "Type A aortic dissection involving the carotid arteries: carotid stenting during open aortic arch surgery by Salvatore Lentini, Fabrizio Tancredi, Filippo Benedetto, and Roberto Gaeta in Interactive CardioVascular and Thoracic Surgery 2009 8: 157-159

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lymphatic vessels transport fluid, antigens, and immune cells to the lymph nodes to orchestrate adaptive immunity and maintain peripheral tolerance. Lymphangiogenesis has been associated with inflammation, cancer metastasis, autoimmunity, tolerance and transplant rejection, and thus, targeted lymphatic ablation is a potential therapeutic strategy for treating or preventing such events. Here we define conditions that lead to specific and local closure of the lymphatic vasculature using photodynamic therapy (PDT). Lymphatic-specific PDT was performed by irradiation of the photosensitizer verteporfin that effectively accumulates within collecting lymphatic vessels after local intradermal injection. We found that anti-lymphatic PDT induced necrosis of endothelial cells and pericytes, which preceded the functional occlusion of lymphatic collectors. This was specific to lymphatic vessels at low verteporfin dose, while higher doses also affected local blood vessels. In contrast, light dose (fluence) did not affect blood vessel perfusion, but did affect regeneration time of occluded lymphatic vessels. Lymphatic vessels eventually regenerated by recanalization of blocked collectors, with a characteristic hyperplasia of peri-lymphatic smooth muscle cells. The restoration of lymphatic function occurred with minimal remodeling of non-lymphatic tissue. Thus, anti-lymphatic PDT allows control of lymphatic ablation and regeneration by alteration of light fluence and photosensitizer dose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The aim of our study was the investigation of a novel navigator-gated three-dimensional (3D) steady-state free-precession (SSFP) sequence for free-breathing renal magnetic resonance angiography (MRA) without contrast medium, and to examine the advantage of an additional inversion prepulse for improved contrast. METHODS: Eight healthy volunteers (mean age 29 years) and eight patients (mean age 53 years) were investigated on a 1.5 Tesla MR system (ACS-NT, Philips, Best, The Netherlands). Renal MRA was performed using three navigator-gated free-breathing cardiac-triggered 3D SSFP sequences [repetition time (TR) = 4.4 ms, echo time (TE) = 2.2 ms, flip angle 85 degrees, spatial resolution 1.25 x 1.25 x 4.0 mm(3), scanning time approximately 1 minute 30 seconds]. The same sequence was performed without magnetization preparation, with a non-slab selective and a slab-selective inversion prepulse. Signal-to-noise ratio (SNR), contrast-to-noise (CNR) vessel length, and subjective image quality were compared. RESULTS: Three-dimensional SSFP imaging combined with a slab-selective inversion prepulse enabled selective and high contrast visualization of the renal arteries, including the more distal branches. Standard SSFP imaging without magnetization preparation demonstrated overlay by veins and renal parenchyma. A non-slab-selective prepulse abolished vessel visualization. CNR in SSFP with slab-selective inversion was 43.6 versus 10.6 (SSFP without magnetization preparation) and 0.4 (SSFP with non-slab-selective inversion), P < 0.008. CONCLUSION: Navigator-gated free-breathing cardiac-triggered 3D SSFP imaging combined with a slab-selective inversion prepulse is a novel, fast renal MRA technique without the need for contrast media.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The authors compared radial steady-state free precession (SSFP) coronary magnetic resonance (MR) angiography, cartesian k-space sampling SSFP coronary MR angiography, and gradient-echo coronary MR angiography in 16 healthy adults and four pilot study patients. Standard gradient-echo MR imaging with a T2 preparatory pulse and cartesian k-space sampling was the reference technique. Image quality was compared by using subjective motion artifact level and objective contrast-to-noise ratio and vessel sharpness. Radial SSFP, compared with cartesian SSFP and gradient-echo MR angiography, resulted in reduced motion artifacts and superior vessel sharpness. Cartesian SSFP resulted in increased motion artifacts (P <.05). Contrast-to-noise ratio with radial SSFP was lower than that with cartesian SSFP and similar to that with the reference technique. Radial SSFP coronary MR angiography appears preferable because of improved definition of vessel borders.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE. Acute mesenteric venous thrombosis signs at MDCT are well described, but the literature lacks studies assessing their evolution. We aimed to describe the radiologic evolution of isolated acute mesenteric venous thrombosis and associated prognostic factors. MATERIALS AND METHODS. Patients with isolated acute mesenteric venous thrombosis with follow-up for a minimum of 1 month with MDCT were selected. Images at the acute phase and on follow-up were reviewed in consensus reading. For acute mesenteric venous thrombosis, we searched for low-attenuated intraluminal filling defect. For chronic mesenteric venous thrombosis, we searched for vessel stenosis or occlusion associated with collateral mesenteric veins. Treatment, thrombosis risk factor, symptoms, location, and length and diameter of mesenteric venous thrombosis were reported and correlated with evolution over time. RESULTS. Twenty patients (nine women and 11 men; mean age, 52 years) were selected. Four patients recovered without radiologic sequelae, and 16 developed chronic mesenteric venous thrombosis signs. Anticoagulation did not influence recovery (p = 1). Patients with recovery compared with patients with chronic mesenteric venous thrombosis showed more frequent central lesions (p = 0.03). At diagnosis, the thrombosed segment was shorter and larger in the complete radiologic recovery group compared with the chronic mesenteric venous thrombosis signs group: mean length (± SD) 6.25 ± 3.21 cm and 12.81 ± 5.96 cm, respectively (p = 0.01); mean transverse diameter 1.82 ± 0.42 cm and 1.12 ± 0.34 cm, respectively (p = 0.01). Mesenteric fat infiltration at diagnosis was more frequent in the chronic mesenteric venous thrombosis signs group than in the complete recovery group (p = 0.03). CONCLUSION. Most cases of acute mesenteric venous thrombosis evolve toward the chronic form with vein stenosis or occlusion and development of collateral veins. Location, length of mesenteric venous thrombosis, transverse diameter of the vein, and mesenteric fat infiltration at diagnosis are determinant factors for mesenteric venous thrombosis evolution.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

During conventional x-ray coronary angiography, multiple projections of the coronary arteries are acquired to define coronary anatomy precisely. Due to time constraints, coronary magnetic resonance angiography (MRA) usually provides only one or two views of the major coronary vessels. A coronary MRA approach that allowed for reconstruction of arbitrary isotropic orientations might therefore be desirable. The purpose of the study was to develop a three-dimensional (3D) coronary MRA technique with isotropic image resolution in a relatively short scanning time that allows for reconstruction of arbitrary views of the coronary arteries without constraints given by anisotropic voxel size. Eight healthy adult subjects were examined using a real-time navigator-gated and corrected free-breathing interleaved echoplanar (TFE-EPI) 3D-MRA sequence. Two 3D datasets were acquired for the left and right coronary systems in each subject, one with anisotropic (1.0 x 1.5 x 3.0 mm, 10 slices) and one with "near" isotropic (1.0 x 1.5 x 1.0 mm, 30 slices) image resolution. All other imaging parameters were maintained. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and the right coronary artery (RCA) were visualized. Objective assessment of coronary vessel sharpness was similar (41% +/- 5% vs. 42% +/- 5%; P = NS) between in-plane and through-plane views with "isotropic" voxel size but differed (32% +/- 7% vs. 23% +/- 4%; P < 0.001) with nonisotropic voxel size. In reconstructed views oriented in the through-plane direction, the vessel border was 86% more defined (P < 0.01) for isotropic compared with anisotropic images. A smaller (30%; P < 0.001) improvement was seen for in-plane reconstructions. Vessel diameter measurements were view independent (2.81 +/- 0.45 mm vs. 2.66 +/- 0.52 mm; P = NS) for isotropic, but differed (2.71 +/- 0.51 mm vs. 3.30 +/- 0.38 mm; P < 0.001) between anisotropic views. Average scanning time was 2:31 +/- 0:57 minutes for anisotropic and 7:11 +/- 3:02 minutes for isotropic image resolution (P < 0.001). We present a new approach for "near" isotropic 3D coronary artery imaging, which allows for reconstruction of arbitrary views of the coronary arteries. The good delineation of the coronary arteries in all views suggests that isotropic 3D coronary MRA might be a preferred technique for the assessment of coronary disease, although at the expense of prolonged scan times. Comparative studies with conventional x-ray angiography are needed to investigate the clinical utility of the isotropic strategy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The PHO1 family comprises 11 members in Arabidopsis thaliana. In order to decipher the role of these genes in inorganic phosphate (Pi) transport and homeostasis, complementation of the pho1 mutant, deficient in loading Pi to the root xylem, was determined by the expression of the PHO1 homologous genes under the control of the PHO1 promoter. Only PHO1 and the homologue PHO1;H1 could complement pho1. The PHO1;H1 promoter was active in the vascular cylinder of roots and shoots. Expression of PHO1;H1 was very low in Pi-sufficient plants, but was strongly induced under Pi-deficient conditions. T-DNA knock-out mutants of PHO1;H1 neither showed growth defects nor alteration in Pi transport dynamics, or Pi content, compared with wild type. However, the double mutant pho1/pho1;h1 showed a strong reduction in growth and in the capacity to transfer Pi from the root to the shoot compared with pho1. Grafting experiments revealed that phenotypes associated with the pho1 and pho1/pho1;h1 mutants were linked to the lack of gene expression in the root. The increased expression of PHO1;H1 under Pi deficiency was largely controlled by the transcription factor PHR1 and was suppressed by the phosphate analogue phosphite, whereas the increase of PHO1 expression was independent of PHR1 and was not influenced by phosphite. Together, these data reveal that although transfer of Pi to the root xylem vessel is primarily mediated by PHO1, the homologue PHO1;H1 also contributes to Pi loading to the xylem, and that the two corresponding genes are regulated by Pi deficiency by distinct signal transduction pathways.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Intensity-modulated radiotherapy (IMRT) credentialing for a EORTC study was performed using an anthropomorphic head phantom from the Radiological Physics Center (RPC; RPCPH). Institutions were retrospectively requested to irradiate their institutional phantom (INSTPH) using the same treatment plan in the framework of a Virtual Phantom Project (VPP) for IMRT credentialing. MATERIALS AND METHODS: CT data set of the institutional phantom and measured 2D dose matrices were requested from centers and sent to a dedicated secure EORTC uploader. Data from the RPCPH and INSTPH were thereafter centrally analyzed and inter-compared by the QA team using commercially available software (RIT; ver.5.2; Colorado Springs, USA). RESULTS: Eighteen institutions participated to the VPP. The measurements of 6 (33%) institutions could not be analyzed centrally. All other centers passed both the VPP and the RPC ±7%/4 mm credentialing criteria. At the 5%/5 mm gamma criteria (90% of pixels passing), 11(92%) as compared to 12 (100%) centers pass the credentialing process with RPCPH and INSTPH (p = 0.29), respectively. The corresponding pass rate for the 3%/3 mm gamma criteria (90% of pixels passing) was 2 (17%) and 9 (75%; p = 0.01), respectively. CONCLUSIONS: IMRT dosimetry gamma evaluations in a single plane for a H&N prospective trial using the INSTPH measurements showed agreement at the gamma index criteria of ±5%/5 mm (90% of pixels passing) for a small number of VPP measurements. Using more stringent, criteria, the RPCPH and INSTPH comparison showed disagreement. More data is warranted and urgently required within the framework of prospective studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Images of myocardial strain can be used to diagnose heart disease, plan and monitor treatment, and to learn about cardiac structure and function. Three-dimensional (3D) strain is typically quantified using many magnetic resonance (MR) images obtained in two or three orthogonal planes. Problems with this approach include long scan times, image misregistration, and through-plane motion. This article presents a novel method for calculating cardiac 3D strain using a stack of two or more images acquired in only one orientation. The zHARP pulse sequence encodes in-plane motion using MR tagging and out-of-plane motion using phase encoding, and has been previously shown to be capable of computing 3D displacement within a single image plane. Here, data from two adjacent image planes are combined to yield a 3D strain tensor at each pixel; stacks of zHARP images can be used to derive stacked arrays of 3D strain tensors without imaging multiple orientations and without numerical interpolation. The performance and accuracy of the method is demonstrated in vitro on a phantom and in vivo in four healthy adult human subjects.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A cardiac-triggered, free-breathing, 3D balanced FFE projection renal MR angiography (MRA) technique with a 2D pencil beam aortic labeling pulse for selective aortic spin tagging was developed. For respiratory motion artifact suppression during free breathing, a prospective real-time navigator was implemented for renal MRA. Images obtained with the new approach were compared with standard contrast-enhanced (CE) 3D breath-hold MRA in seven swine. Signal properties and vessel visualization were analyzed. With the presented technique, high-resolution, high-contrast renal projection MRA with superior vessel length visualization (including a greater visible number of distal branches of the renal arteries) compared to standard breath-hold CE-MRA was obtained. The present results warrant clinical studies in patients with renal artery disease.