952 resultados para Ultrasonography, Doppler, Color


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Color texture classification is an important step in image segmentation and recognition. The color information is especially important in textures of natural scenes, such as leaves surfaces, terrains models, etc. In this paper, we propose a novel approach based on the fractal dimension for color texture analysis. The proposed approach investigates the complexity in R, G and B color channels to characterize a texture sample. We also propose to study all channels in combination, taking into consideration the correlations between them. Both these approaches use the volumetric version of the Bouligand-Minkowski Fractal Dimension method. The results show a advantage of the proposed method over other color texture analysis methods. (C) 2011 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports on the infrared-to-visible CW frequency upconversion from planar waveguides based on Er3+-Yb3+-doped 100-xSiO(2)-xTa(2)O(5) obtained by a sol-gel process and deposited onto a SiO2-Si substrate by dip-coating. Surface morphology and optical parameters of the planar waveguides were analyzed by atomic force microscopy and the m-line technique. The influence of the composition on the electronic properties of the glass-ceramic films was followed by the band gap ranging from 4.35 to 4.51 eV upon modification of the Ta2O5 content. Intense green and red emissions were detected from the upconversion process for all the samples after excitation at 980 nm. The relative intensities of the emission bands around 550 nm and 665 nm, assigned to the H-2(11/2) -> I-4(15/2), S-4(3/2) -> I-4(15/2), and F-4(9/2) -> I-4(15/2) transitions, depended on the tantalum oxide content and the power of the laser source at 980 nm. The upconversion dynamics were investigated as a function of the Ta2O5 content and the number of photons involved in each emission process. Based on the upconversion emission spectra and 1931CIE chromaticity diagram, it is shown that color can be tailored by composition and pump power. The glass ceramic films are attractive materials for application in upconversion lasers and near infrared-to-visible upconverters in solar cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The purpose of this study was to evaluate the effect of mouth rinse solutions Lion color stability, surface roughness and microhardness of two composite resins. Material and Methods: Fifty test specimens of each composite (Filtek Z250 and Z350; 3M ESPE) were made using a teflon matrix (12x2 mm). Color, surface roughness and Knoop microhardness baseline measurements of each specimen were made and specimens (n=10) were immersed in 5 mouth rinse solutions: G1: distilled water (control), G2: Plax Classic, G3: Plax alcohol-free; G4: Periogard, and G5: Listerine. Final measurements of color, roughness and microhardness were performed and the results submitted to statistical analysis (2-way ANOVA, Bonferroni's test; p<0.05). Results: The most significant color change was observed for Z250 when immersed in Listerine (p<0.05). Z350 showed greater color change when immersed in Plax alcohol-free (p<0.05), but with no significant difference for Listerine (p>0.05). With regard to roughness, both composites showed significant changes when immersed in Listerine in comparison with Plax alcohol-free (p<0.05). Microhardness of Z350 was shown to be significantly changed when the composite was immersed in Plax alcohol-free (p<0.05). Conclusion: Composite changes depended on the material itself rather than the mouth rinse solution used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Brain metastases (BM) are one of the most common intracranial tumors and surgical treatment can improve both the functional outcomes and patient survival, particularly when systemic disease is controlled. Image-guided BM resection using intraoperative exams, such as intraoperative ultrasound (IOUS), can lead to better surgical results. Methods: To evaluate the use of IOUS for BM resection, 20 consecutives patients were operated using IOUS to locate tumors, identify their anatomical relationships and surgical cavity after resection. Technical difficulties, complications, recurrence and survival rates were noted. Results: IOUS proved effective for locating, determining borders and defining the anatomical relationships of BM, as well as to identify incomplete tumor resection. No complications related to IOUS were seen. Conclusion: IOUS is a practical supporting method for the resection of BM, but further studies comparing this method with other intraoperative exams are needed to evaluate its actual contribution and reliability.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The identification of color vision types in primates is fundamental to understanding the evolution and biological function of color perception. The Hard, Randy, and Rittler (HRR) pseudoisochromatic test categorizes human color vision types successfully. Here we provide an experimental setup to employ HRR in a nonhuman primate, the capuchin (Cebus libidinosus), a platyrrhine with polymorphic color vision. The HRR test consists of plates with a matrix composed of gray circles that vary in size and brightness. Differently colored circles form a geometric shape (X, O, or Delta) that is discriminated visually from the gray background pattern. The ability to identify these shapes determines the type of dyschromatopsy (deficiency in color vision). We tested six capuchins in their own cages under natural sunlight. The subjects chose between two HRR plates in each trial: one with the gray pattern only and the other with a colored shape, presented on the left or right side at random. We presented the test 40 times and calculated the 95 % confidence limits for chance performance based on the binomial test. We also genotyped all subjects for exons 3 and 5 of the X-linked opsin genes. The HRR test diagnosed two subjects as protan dichromats (missing or defective L-cone), three as deutan dichromats (missing or defective M-cone), and one female as trichromat. Genetic analysis supported the behavioral data for all subjects. These findings show that the HRR test can be applied to diagnose color vision in nonhuman primates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reproductive diseases are a great barrier to dairy production, as they diminish fertility and cause economic loss. In this context, endometritis plays an important role. Different diagnostic techniques exist for endometritis that vary in sensitivity and specificity. This work aimed to evaluate and compare ultrasonographic and histopathological examinations, and combinations thereof, for the diagnosis of endometritis by determining their sensitivity, specificity, and kappa agreement coefficients using endometrial cytology as the gold standard. We developed an adaptive reading score to perform histological examination of the uterus. In this study, 76 Holstein-Friesian cows, 21 to 47 d postpartum, without vaginal catarrh were submitted to gynecological examinations, including ultrasonographic examination, an endometrial cytology examination, and a uterine biopsy. Our results indicate that ultrasonography is a practical and effective diagnostic method, and a combination of the determination of intrauterine fluid and cervical diameter was the most efficient ultrasonographic method, with 50% sensitivity and 88% specificity. Histopathological examination was a useful diagnostic method that provided rich detail on endometrial inflammation, and allowed evaluation of different components of the tissue such as the epithelium, lamina propria, endometrial glands, and blood vessels; this method had 44% sensitivity and 92% specificity for diagnosis of endometritis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the visual outcome of chronic occupational exposure to a mixture of organic solvents by measuring color discrimination, achromatic contrast sensitivity and visual fields in a group of gas station workers. We tested 25 workers (20 males) and 25 controls with no history of chronic exposure to solvents (10 males). All participants had normal ophthalmologic exams. Subjects had worked in gas stations on an average of 9.6 +/- 6.2 years. Color vision was evaluated with the Lanthony D15d and Cambridge Colour Test (CCT). Visual field assessment consisted of white-on-white 24-2 automatic perimetry (Humphrey II-750i). Contrast sensitivity was measured for sinusoidal gratings of 0.2, 0.5, 1.0, 2.0, 5.0, 10.0 and 20.0 cycles per degree (cpd). Results from both groups were compared using the Mann-Whitney U test. The number of errors in the D15d was higher for workers relative to controls (p<0.01). Their CCT color discrimination thresholds were elevated compared to the control group along the protan, deutan and tritan confusion axes (p<0.01), and their ellipse area and ellipticity were higher (p<0.01). Genetic analysis of subjects with very elevated color discrimination thresholds excluded congenital causes for the visual losses. Automated perimetry thresholds showed elevation in the 9 degrees, 15 degrees and 21 degrees of eccentricity (p<0.01) and in MD and PSD indexes (p<0.01). Contrast sensitivity losses were found for all spatial frequencies measured (p<0.01) except for 0.5 cpd. Significant correlation was found between previous working years and deutan axis thresholds (rho = 0.59; p<0.05), indexes of the Lanthony D15d (rho = 0.52; p<0.05), perimetry results in the fovea (rho = -0.51; p<0.05) and at 3, 9 and 15 degrees of eccentricity (rho = -0.46; p<0.05). Extensive and diffuse visual changes were found, suggesting that specific occupational limits should be created.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the correlation between ph at birth and venous Doppler parameters in pregnancies with placental dysfunction. Methods: This was a prospective cohort study of 58 pregnancies with the diagnosis of placental dysfunction between 26 and 34 weeks of gestation. Inclusion criteria were singleton pregnancies, abnormal umbilical artery (UA) Doppler, fetal growth restriction diagnosed by estimated fetal weight <10th centile for gestational age, intact membranes, and absence of fetal congenital abnormalities. The Doppler measurements were the following: UA pulsatility index (PI), ductus venosus (DV) pulsatility index for veins (PIV), intra-abdominal umbilical vein (UV) time-averaged maximum velocity (TAMxV) and blood flow and left portal vein (LPV) time-averaged maximum velocity (TAMxV) and blood flow. All Doppler parameters were transformed into z-scores (SD values from the mean) according to normative references. Results: The UA pH at birth showed a negative significant correlation with the DV-PIV (p = 0.004) and the DV-PIV z-score (p = 0.004), while LPV TAMxV (p = 0.004), LPV TAMxV z-score (p = 0.002), LPV blood flow (p = 0.01), LPV blood flow normalized (p = 0.04) and UV blood flow (p = 0.04) positively correlated with pH at birth. Multiple regression analysis was performed and the DV-PIV z-score was the variable that independently correlated with pH at birth (p = 0.002). Conclusions: the present results suggest that changes in fetal venous blood flow, mainly DV and LPV are useful in the management of cases with early onset placental insufficiency and that venous Doppler parameters correlate with pH at birth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To assess the fetal lumbosacral spine by three-dimensional (3D) ultrasonography using volume contrast imaging (VCI) omni view method and compare reproducibility and agreement between three different measurement techniques: standard mouse, high definition mouse and pen-tablet. Methods: A comparative and prospective study with 40 pregnant women between 20 and 34+6 weeks was realized. 3D volume datasets of the fetal spine were acquired using a convex transabdominal transducer. Starting scan plane was the coronal section of fetal lumbosacral spine by VCI-C function. Omni view manual trace was selected and a parallel plane of fetal spine was drawn including interest region. Intraclass correlation coefficient (ICC) was used for reproducibility analysis. The relative difference between three used techniques was compared by chi-square test and Fischer test. Results: Pen-tablet showed better reliability (ICC = 0.987). In the relative proportion of differences, this was significantly higher for the pen-tablet (82.14%; p < 0.01). In paired comparison, the relative difference was significantly greater for the pen-tablet (p < 0.01). Conclusion: The pen-tablet showed to be the most reproductive and concordant method in the measurement of body vertebral area of fetal lumbosacral spine by 3D ultrasonography using the VCI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare the agreement of multiplanar and rendering modes in the assessment fetal atrioventricular valves (mitral and tricuspid) areas by three-dimensional (3D) ultrasonography using the software spatio-temporal image correlation (STIC). Methods: We conducted a prospective cross-sectional study with normal pregnant women, with single fetuses, between 18-33 weeks. To measure the areas, we used the plan of four-chamber view. In the case of multiplanar, the plane was rotated on the axis "Z" form the heart to position at 9h. For rendering, the green line (region of interest - ROI) was placed from the atria of the heart perpendicular to the crux. The agreement was assessed by a Bland-Altman (limits of agreement) using the relative difference between the measures: ((rendering mode) - (multiplanar mode)) / (average). Results: 328 fetuses were evaluated. We have not identified the occurrence of systematic error between methods: the average relative difference was 1.62% (-2.07% to 5.32%, confidence interval 95%) in the mitral and 1.77% (- 1.08% to 4.62%) in the tricuspid valve. The limits of agreement between methods were -65.26% to 68.51% for the mitral and -49.91% to 53.45% for the tricuspid. Conclusions: There was no systematic error between modes and thus the observed values for the area of fetal atrioventricular valves can be used for comparisons needs to be corrected. However, relatively large variations may be observed when repeating the measurement area by different modes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the influence of beverages and brushing on the surface roughness(SR) and color change(Delta E) of a composite resin. For this, 120-disks(10 mmx2 mm) of composite resin(Filtek-Z250) were prepared and polished. Initials SR(Ra-mu m) and color(CIELab-system) were measured with rugosimeter and spectrophotometer; specimens were divided into four groups(red wine, soft drink, sugar cane spirit, or artificial saliva=control) and three subgroups(without brushing; brushed with Colgate or with Close-Up). Specimens were immersed in the beverage 5x/day, for 5', over 30 day, being two subgroups brushed(120 strokes/day). Color was measured at 15th day, 30th day and after repolishment; SR at 30th day. Delta E-values were statistically different after immersion in the beverages(p<0.05). Red wine promoted the highest alteration, followed by soft drink=sugar cane spirit and finally saliva. At 30th day, specimens exhibited Delta E higher than 15th day; after repolishing, Delta E was similar to 15th day. Beverages and brushing negatively influenced the SR. Therefore, Delta E and SR can be influenced by beverages and brushing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Few equations have been developed in veterinary medicine compared to human medicine to predict body composition. The present study was done to evaluate the influence of weight loss on biometry (BIO), bioimpedance analysis (BIA) and ultrasonography (US) in cats, proposing equations to estimate fat (FM) and lean (LM) body mass, as compared to dual energy x-ray absorptiometry (DXA) as the referenced method. For this were used 16 gonadectomized obese cats (8 males and 8 females) in a weight loss program. DXA, BIO, BIA and US were performed in the obese state (T0; obese animals), after 10% of weight loss (T1) and after 20% of weight loss (T2). Stepwise regression was used to analyze the relationship between the dependent variables (FM, LM) determined by DXA and the independent variables obtained by BIO, BIA and US. The better models chosen were evaluated by a simple regression analysis and means predicted vs. determined by DXA were compared to verify the accuracy of the equations. Results: The independent variables determined by BIO, BIA and US that best correlated (p < 0.005) with the dependent variables (FM and LM) were BW (body weight), TC (thoracic circumference), PC (pelvic circumference), R (resistance) and SFLT (subcutaneous fat layer thickness). Using Mallows'Cp statistics, p value and r(2), 19 equations were selected (12 for FM, 7 for LM); however, only 7 equations accurately predicted FM and one LM of cats. Conclusions: The equations with two variables are better to use because they are effective and will be an alternative method to estimate body composition in the clinical routine. For estimated lean mass the equations using body weight associated with biometrics measures can be proposed. For estimated fat mass the equations using body weight associated with bioimpedance analysis can be proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Foram realizados o estudo morfométrico e o estudo hemodinâmico da veia porta em vinte cães clinicamente normais, de idade igual e inferior a 120 dias e em quatorze cães portadores de shunt portossistêmico, de idades entre 90 e 360 dias. Nos cães do grupo controle, as margens hepáticas apresentaram-se entre 1,50cm e 3,00cm caudalmente à margem costal. Os diâmetros médios da veia porta (VP), veia cava caudal (VCC) e aorta abdominal (AO) obtidas foram respectivamente, 0,38cm, 0,37cm e 0,41cm. As proporções entre os diâmetros médios VP/VCC e VP/AO apresentaram médias de 1,10 e 0,94, respectivamente. As médias das áreas da VP, VCC e AO resultaram respectivamente em 0,12cm2 , 0,11cm2 e 0,14cm2. No estudo hemodinâmico da VP destes animais, utilizando-se o ultrassom Doppler, a velocidade média de fluxo sangüíneo portal (VMFSP) mediu 17,76cm/s. A média de fluxo sangüíneo portal (FSP) resultou em 83,11ml/min/kg. O índice de congestão (IC) apresentou média de 0,006. Para o grupo de cães portadores de shunt portossistêmico, o fígado apresentou redução de seu volume, sendo as margens hepáticas visibilizadas entre 1,00cm e 2,00cm cranialmente à margem costal. No estudo morfométrico, as médias dos diâmetros médios obtidos de VP, VCC e AO resultaram respectivamente em 0,40cm, 0,74cm e 0,56cm. As proporções entre os diâmetros médios VP/VCC e VP/AO resultaram respectivamente em 0,54 e 0,69. As médias das áreas de VP, VCC e AO resultaram respectivamente em 0,14cm2, 0,31cm2 e 0,25cm2. Ao ultrassom Doppler a VMFSP mediu 22,29cm/s e a média do IC da VP obtido foi de 0,006.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is well known that crystals of topaz from the Eastern Brazilian Pegmatite Province may turn blue by the irradiation with Co-60 gamma rays followed by heat treatment. Also, it is known that the sensation of color changes with the thickness of these crystals. The dependence of the color, given by 1931 CIE chromaticity coordinates, with the thickness of the crystal was analyzed. The absorbance used in the calculation of these coordinates was given by the sum of Gaussian lines. The parameters of these lines were determined through the decomposition of the optical absorption spectra in the ultraviolet and visible regions. The decomposition revealed several lines, whose assignment was made considering studies in spodumene and beryl crystals and highly accurate quantum mechanical calculations. The transmittance becomes very narrow with increasing thickness, and the CIE chromaticity coordinates converge to the borderline of the CIE Chromaticity Diagram at the wavelength of maximum transmittance. Furthermore, the purity of color increases with increasing thickness, and the dominant wavelength reaches the wavelength of maximum transmittance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To estimate the response in lung growth and vascularity after fetal endoscopic tracheal occlusion for severe congenital diaphragmatic hernia in the prediction of neonatal survival. METHODS: Between January 2006 and December 2010, fetal lung parameters (observed-to-expected lung-to-head ratio; observed-to-expected lung volume; and contralateral lung vascularization index) were evaluated before fetal tracheal occlusion and were evaluated longitudinally every 2 weeks in 72 fetuses with severe isolated congenital diaphragmatic hernia. Thirty-five fetuses underwent fetal endoscopic tracheal occlusion and 37 cases did not. RESULTS: Survival rate was significantly higher in the fetal endoscopic tracheal occlusion group (54.3%) than in the no fetal endoscopic tracheal occlusion group (5.4%, P<.01). Fetal endoscopic tracheal occlusion resulted in a significant improvement in fetal lung size and pulmonary vascularity when compared with fetuses that did not go to the fetal intervention (increase of the observed-to-expected lung-to-head ratio, observed-to-expected total lung volume, and contralateral pulmonary vascularization index 56.2% compared with 0.3%, 37.9% compared with 0.1%, and 98.6% compared with 0.0%, respectively; P<.01). Receiver operating characteristic curves indicated that the observed-to-expected total fetal lung volume was the single best predictor of neonatal survival before fetal endoscopic tracheal occlusion (cutoff 0.23, area under the curve [AUC] 0.88, relative risk 5.3, 95% confidence interval [CI] 1.4-19.7). However, the contralateral lung vascularization index at 4 weeks after fetal endoscopic tracheal occlusion was more accurate in the prediction of neonatal outcome (cutoff 24.0%, AUC 0.98, relative risk 9.9, 95% CI 1.5-66.9) with the combination of observed-to-expected lung volumes and contralateral lung vascularization index at 4 weeks being the best predictor of outcome (AUC 0.98, relative risk 16.6, 95% CI 2.5-112.3). CONCLUSION: Fetal endoscopic tracheal occlusion improves survival rate by increasing the lung size and pulmonary vascularity in fetuses with severe congenital diaphragmatic hernia. The pulmonary response after fetal endoscopic tracheal occlusion can be used to predict neonatal survival. (Obstet Gynecol 2012; 119: 93-101) DOI: 10.1097/AOG.0b013e31823d3aea