969 resultados para Tracheal airway
Resumo:
Chemokines are important chemotactic cytokines that play a fundamental role in the trafficking of leukocytes to sites of inflammation. They are also potent cell-activating factors, inducing cytokine and histamine release and free radical production, a fact that makes them particularly important in the pathogenesis of allergic inflammation. The action of chemokines is regulated at the level of agonist production and processing as well as at the level of receptor expression and coupling. Therefore, an analysis of the ligands must necessarily consider receptors. Eosinophils are target cells involved in the allergic inflammatory response since they are able to release a wide variety of mediators including CC and CXC chemokines and express their receptors. These mediators could damage the airway epithelial cells and might be important to stimulate other cells inducing an amplification of the allergic response. This review focuses on recently emerging data pertaining to the importance of chemokines and chemokine receptors in promoting eosinophil activation and migration during the allergic inflammatory process. The analysis of the function of eosinophils and their chemokine receptors during allergic inflammation might be a good approach to understanding the determinants of asthma severity and to developing novel therapies.
Resumo:
Objective: The aim of the present study was to use facial analysis to determine the effects of rapid maxillary expansion (RME) on nasal morphology in children in the stages of primary and mixed dentition, with posterior cross-bite. Material and Methods: Facial photographs (front view and profile) of 60 patients in the pre-expansion period, immediate post-expansion period and one year following rapid maxillary expansion with a Haas appliance were evaluated on 2 occasions by 3 experienced orthodontists independently, with a 2-week interval between evaluations. The examiners were instructed to assess nasal morphology and had no knowledge regarding the content of the study. Intraexanniner and interexanniner agreement (assessed using the Kappa statistic) was acceptable. Results: From the analysis of the mode of the examiners' findings, no alterations in nasal morphology occurred regarding the following aspects: dorsunn of nose, alar base, nasal width of middle third and nasal base. Alterations were only detected in the nasolabial angle in 1.64% of the patients between the pre-expansion and immediate post-expansion photographs. In 4.92% of the patients between the immediate post-expansion period and 1 year following expansion; and in 6.56% of the patients between the pre-expansion period and one year following expansion. Conclusion: RME performed on children in stages of primary and mixed dentition did not have any impact on nasal morphology, as assessed using facial analysis.
Resumo:
A finalidade deste artigo é avaliar o efeito da expansão rápida da maxila (ERM) no padrão respiratório. Por intermédio de um caso clínico, será relatado como indivíduos com atresia da maxila e problemas respiratórios podem se beneficiar com a expansão rápida da maxila. Outro aspecto que deve-se salientar é como profissionais da área da saúde, principalmente ortodontistas e otorrinolaringologistas, têm à sua disposição exames complementares para o diagnóstico do paciente com Respiração Bucal
Central nervous system of Rhipicephalus sanguineus ticks (Acari: Ixodidae): an ultrastructural study
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Background There is renewed interest in the role played by specific counter-regulatory mechanisms to control the inflammatory host response, poorly investigated in human pathology. Here, we monitored the expression of two anti-inflammatory mediators, annexin 1 and galectin-1, and assessed their potential link to glucocorticoids' (GCs) effective control of nasal polyposis (NP).Methods Total patterns of mRNA and protein expression were analysed by quantitative real-time PCR (qPCR) and Western blotting analyses, whereas ultrastructural immunocytochemistry was used for spatial localization and quantification of each mediator, focusing on mast cells, eosinophils and epithelial cells.Results Up-regulation of the annexin 1 gene, and down-regulation of galectin-1 gene, was detected in polypoid tissue compared with nasal mucosa. Patient treatment with betamethasone augmented galectin-1 protein expression in polyps. At the cellular level, control mast cells and eosinophils displayed higher annexin 1 expression, whereas marked galectin-1 immunolabelling was detected in the granule matrix of mast cells. Cells of glandular duct epithelium also displayed expression of both annexin 1 and galectin-1, augmented after treatment.Conclusion Mast cells and epithelial cells appeared to be pivotal cell types involved in the expression of both annexin 1 and galectin-1. It is possible that annexin 1 and galectin-1 could be functionally associated with a specific mechanism in NP and that GC exert at least part of their beneficial effects on the airway mucosa by up-regulating, in a specific cell target fashion, these anti-inflammatory agonists.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
INTRODUÇÃO: a avaliação do espaço aéreo superior faz parte da rotina na elaboração do diagnóstico e plano de tratamento ortodôntico. A radiografia cefalométrica em norma lateral tem sido usada rotineiramente na avaliação da permeabilidade do espaço aéreo, esbarrando na limitação de fornecer uma imagem bidimensional de uma estrutura tridimensional. A Tomografia Computadorizada de Feixe Cônico (TCFC) tem entrado na realidade ortodôntica trazendo um arsenal de informações concernentes ao espaço aéreo superior. Por fornecer uma imagem tridimensional, possibilita determinar de maneira precisa a área de maior estreitamento da faringe, que ofereceria maior resistência à passagem aérea. OBJETIVOS: o propósito deste artigo é esclarecer o ortodontista quanto aos recursos disponíveis na TCFC para o diagnóstico de possíveis barreiras físicas que possam diminuir a permeabilidade das vias aéreas superiores.
Resumo:
A finalidade deste artigo é avaliar o efeito da expansão rápida da maxila (ERM) na via aérea superior. Por intermédio de um caso clínico, será relatado como indivíduos com atresia da maxila e com comprometimento da função naso-respiratória podem beneficiar-se com a ERM. Para entender melhor as alterações morfológicas decorrentes do paciente com problemas respiratórios, deve-se conhecer a anatomia e a fisiologia do sistema respiratório. Entretanto, não se pode esquecer que o tratamento deste paciente é multidisciplinar, envolvendo o ortodontista, otorrinolaringologista e a fonoaudióloga.
Resumo:
INTRODUCTION: Among the sleep disorders reported by the American Academy of Sleep, the most common is obstructive sleep apnea-hypopnea syndrome (OSAHS), which is caused by difficulties in air passage and complete interruption of air flow in the airway. This syndrome is associated with increased morbidity and mortality in apneic individuals. OBJECTIVE: It was the objective of this paper to evaluate a removable mandibular advancement device as it provides a noninvasive, straightforward treatment readily accepted by patients. METHODS: In this study, 15 patients without temporomandibular disorders (TMD) and with excessive daytime sleepiness or snoring were evaluated. Data were collected by means of: Polysomnography before and after placement of an intraoral appliance, analysis of TMD signs and symptoms using a patient history questionnaire, muscle and TMJ palpation. RESULTS: After treatment, the statistical analysis (t-test, and the before and after test) showed a mean reduction of 77.6% (p=0.001) in the apnea-hypopnea index, an increase in lowest oxyhemoglobin saturation (p=0.05), decrease in desaturation (p=0.05), decrease in micro-awakenings or EEG arousals (p=0.05) and highly significant improvement in daytime sleepiness (p=0.005), measured by the Epworth Sleepiness Scale. No TMD appeared during the monitoring period. CONCLUSION: The oral device developed in this study was considered effective for mild to moderate OSAHS.
Resumo:
Compararam-se os efeitos de duas doses de cetamina, administradas em infusão contínua, sobre a pressão intra-ocular (PIO) de 18 cães submetidos à hipovolemia e à anestesia com desflurano. Promoveu-se a hipovolemia em todos os cães, retirando-se 40 ml de sangue/kg de peso. A anestesia foi induzida com desflurano, através de máscara facial, até que a intubação orotraqueal fosse permitida. Decorridos 30 minutos, para estabilização dos parâmetros, iniciou-se a infusão contínua de cetamina. Os cães foram distribuídos, aleatoriamente, em três grupos (n= 6). O grupo I (controle) recebeu solução salina estéril; o grupo II (GII) recebeu cetamina, na dose de 100mig/kg/min, e o grupo III (GIII), cetamina na dose de 200mig/kg/min. A PIO foi medida por tonometria de aplanação. Foram mensurados freqüência cardíaca (FC), ritmo cardíaco, pressão arterial média (PAM), débito cardíaco (DC), pressão venosa central (PVC) e pressão parcial de CO2 no final da expiração (ETCO2). O desflurano não influenciou os resultados da PIO, porém observou-se discreta ação da cetamina em todos os grupos. Foi possível estabelecer relação direta entre os valores de PIO e de ETCO2. A PIO apresentou relação direta somente com a ETCO2.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A utilização das drogas agonistas dos alfa2-adrenoceptores para controlar a pressão arterial e freqüência cardíaca, propiciar menores respostas hemodinâmicas à intubação e extubação traqueal e poupar anestésicos já está difundida na literatura desde a introdução da clonidina. O desenvolvimento de agentes providos de maior seletividade alfa2-adrenoceptora que, por isso, determinam menos efeitos adversos, como a dexmedetomidina, recentemente liberada para utilização clínica, possibilitou que ocorressem maior sedação e analgesia com o seu uso. Despertou-se, então, o interesse em sua utilização como substitutos dos opióides, conhecidos por determinarem potente analgesia e sedação. O objetivo deste trabalho foi comparar a analgesia promovida pela dexmedetomidina e pelo sufentanil, utilizados em infusões contínuas durante anestesias de procedimentos otorrinolaringológicos e de cabeça e pescoço. MÉTODO: Os 60 pacientes estudados foram divididos em dois grupos de 30: G1, recebendo sufentanil e G2, dexmedeto- midina, na indução e manutenção anestésicas. Para a manutenção da anestesia utilizaram-se, também, o óxido nitroso e o propofol, em infusão contínua alvo-controlada. Foram avaliados os parâmetros hemodinâmicos (pressões arteriais sistólica e diastólica e freqüência cardíaca), tempos de despertar e de extubação após interrupção do propofol, locais onde foram extubados os pacientes, sala de operação (SO) ou sala de recuperação pós-anestésica (SRPA), tempo de permanência na SRPA, índice de Aldrete e Kroulik e as complicações apresentadas na SO e SRPA. RESULTADOS: G1 apresentou menores valores de pressões arteriais sistólica, diastólica e freqüência cardíaca, tempos de despertar e extubação maiores, maior número de extubações na SRPA, maior tempo de permanência na SRPA, valores mais baixos para Aldrete e Kroulik na alta da SRPA e mais complicações per e pós-operatórias. CONCLUSÕES: A utilização de dexmedetomidina como analgésico per-operatório apresentou melhores resultados que a de sufentanil, nos procedimentos selecionados neste trabalho, com relação à estabilidade hemodinâmica e às condições de despertar e de recuperação anestésica.
Resumo:
JUSTIFICATIVA E OBJETIVOS: Dentre as indicações mais freqüentes de sedação em pacientes internados em Unidades de Terapia Intensiva (UTI) estão a instituição e a manutenção de ventilação artificial, a ansiedade e procedimentos desconfortáveis ou dolorosos. O objetivo deste estudo retrospectivo foi verificar as indicações e as técnicas mais comuns de sedação em pacientes graves internados na Unidade de Terapia Intensiva Cirúrgica da Escola Paulista de Medicina (EPM/UNIFESP) durante um período de 11 meses. MÉTODO: Após terem sido excluídos os pacientes que permaneceram na UTI menos de 24 horas ou estavam sem exames indispensáveis para o cálculo do índice de gravidade (APACHE II), a amostra ficou reduzida a 307 pacientes. Foram analisadas as técnicas mais utilizadas, as indicações de sedação e a associação de bloqueadores neuromusculares. RESULTADOS: A sedação foi administrada em 37,4% dos pacientes. Entre as indicações de sedação estão os distúrbios de natureza psiquiátrica, como delírio, agitação, medo e ansiedade. Estas corresponderam a 25,77% de todas as indicações. A maioria dos pacientes ventilados artificialmente também necessita de sedativos. Instalação e manutenção de ventilação mecânica corresponderam à maioria das indicações, em torno de 57,73% dentre os pacientes sedados. Procedimentos como intubação traqueal e broncoscopia tiveram 11,34% das indicações e controle do metabolismo (coma barbitúrico e tétano), 5,15%. As técnicas mais comumente utilizadas incluíram opióides isolados ou associados a benzodiazepínicos. Neste estudo, o fentanil foi utilizado em 58% das técnicas, isoladamente, e em 21,64% associado ao midazolam. Haloperidol, diazepam, propofol e tiopental somaram 19,5%. Bloqueadores neuromusculares foram utilizados em 22,7% dos casos em pacientes ventilados artificialmente. CONCLUSÕES: A sedação é recurso terapêutico freqüente em Terapia Intensiva, comumente utilizada para facilitar a ventilação artificial e tratar os problemas de natureza psiquiátrica. Fentanil, isoladamente ou em associação com midazolam, foi o agente mais utilizado.
Resumo:
JUSTIFICATIVA E OBJETIVOS: A indução da anestesia por meio da técnica de seqüência rápida é utilizada, principalmente, para proteger as vias aéreas, quando há risco de aspiração do conteúdo gástrico. O objetivo deste artigo é revisar a técnica e os diferentes protocolos que buscam o uso racional dos fármacos disponíveis, visando condições ideais de intubação traqueal, sem aumentar o risco de aspiração do conteúdo gástrico ou de outras complicações. CONTEÚDO: Apresenta uma revisão da técnica da indução com seqüência rápida, enfatizando o uso racional dos hipnóticos, opióides e bloqueadores neuromusculares (BNM), para reduzir o período entre a perda da consciência e o correto posicionamento do tubo traqueal, ou seja, diminuir o período de maior risco para aspiração e ainda manter excelentes condições de intubação traqueal. CONCLUSÕES: A intubação traqueal após indução anestésica por meio da técnica de seqüência rápida está indicada naqueles pacientes, com risco de aspiração gástrica, em que não há suspeita de intubação traqueal difícil. A indicação correta da técnica, sua aplicação criteriosa e a utilização racional das drogas disponíveis podem promover condições excelentes de intubação, com curto período de latência, rápido retorno da consciência e da respiração espontânea, caso haja falha na intubação traqueal.