987 resultados para Thermal Imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis gives an overview of the validation process for thermal hydraulic system codes and it presents in more detail the assessment and validation of the French code CATHARE for VVER calculations. Three assessment cases are presented: loop seal clearing, core reflooding and flow in a horizontal steam generator. The experience gained during these assessment and validation calculations has been used to analyze the behavior of the horizontal steam generator and the natural circulation in the geometry of the Loviisa nuclear power plant. The cases presented are not exhaustive, but they give a good overview of the work performed by the personnel of Lappeenranta University of Technology (LUT). Large part of the work has been performed in co-operation with the CATHARE-team in Grenoble, France. The design of a Russian type pressurized water reactor, VVER, differs from that of a Western-type PWR. Most of thermal-hydraulic system codes are validated only for the Western-type PWRs. Thus, the codes should be assessed and validated also for VVER design in order to establish any weaknesses in the models. This information is needed before codes can be used for the safety analysis. Theresults of the assessment and validation calculations presented here show that the CATHARE code can be used also for the thermal-hydraulic safety studies for VVER type plants. However, some areas have been indicated which need to be reassessed after further experimental data become available. These areas are mostly connected to the horizontal stem generators, like condensation and phase separation in primary side tubes. The work presented in this thesis covers a large numberof the phenomena included in the CSNI code validation matrices for small and intermediate leaks and for transients. Also some of the phenomena included in the matrix for large break LOCAs are covered. The matrices for code validation for VVER applications should be used when future experimental programs are planned for code validation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A beautiful smile is directly related with white teeth. Nowadays oral care has increased and developed processes for beautiful smiles. Dental bleaching is frequently used in odontology, not just for health care also for aesthetic treatment. With the possibility of teeth bleaching, now the importance is in, how white the tooth is? Because color is relate to an individual perception. In order to assets teeth correct color identification has been developed many color guides, models, spaces and analytical methods. Spite all of these useful tools the color interpretation depends on environmental factors, position of the sample in the data acquisition and most importantly the instrument sensitivity. The commons methods have proved to be useful. They are easy to handle, some are portable but they do not have a high sensitivity. The present work is based on the integration of a new analytical technique for color acquisition. High spectral Image (HSI) is able to performed image analysis with high quality and efficiency. HSI is used in many fields and we used it for color image analysis within the bleaching process. The main comparison was done with the HSI and the colorimeter through the processes of two different bleaching protocols. The results showed that HSI has higher sensitivity than the colorimeter. During the analysis the dental surface with the HSI we were able to notice surface changes. These changes were analyzed by roughness studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Neuronal dynamics are fundamentally constrained by the underlying structural network architecture, yet much of the details of this synaptic connectivity are still unknown even in neuronal cultures in vitro. Here we extend a previous approach based on information theory, the Generalized Transfer Entropy, to the reconstruction of connectivity of simulated neuronal networks of both excitatory and inhibitory neurons. We show that, due to the model-free nature of the developed measure, both kinds of connections can be reliably inferred if the average firing rate between synchronous burst events exceeds a small minimum frequency. Furthermore, we suggest, based on systematic simulations, that even lower spontaneous inter-burst rates could be raised to meet the requirements of our reconstruction algorithm by applying a weak spatially homogeneous stimulation to the entire network. By combining multiple recordings of the same in silico network before and after pharmacologically blocking inhibitory synaptic transmission, we show then how it becomes possible to infer with high confidence the excitatory or inhibitory nature of each individual neuron.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Els materials de canvi de fase (PCM) han estat considerats per a l’emmagatzematge tèrmic en edificis des de 1980. Amb la inclusió dels PCM en plaques de guix, guix, formigó o altres materials que s’utilitzen per a cobrir les parets, l’emmagatzematge tèrmic pot ser part de les estructures fins i tot en edificis lleugers. Les noves tècniques de microencapsulació han obert moltes possibilitats en aplicacions per a edificis. El treball que es presenta és el desenvolupament d’un formigó innovador mesclat amb PCM microencapsulat, amb un punt de fusió de 26 oC i una entalpia de canvi de fase de 110 kJ/kg. El primer experiment va ser la inclusió del PCM microencapsulat dins del formigó i la construcció d’una caseta amb aquest nou formigó-PCM. Es va construir una segona caseta al costat de la primera amb les mateixes característiques i orientació però amb formigó convencional que serveix com a referència. Durant els anys 2005 i 2006 es va analitzar el comportament d’ambdues casetes i més tard es va edificar un mur Trombe a la paret sud de totes dues per investigar la seva influència durant la tardor i l’hivern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare qualitative and quantitative magnetic resonance (MR) imaging characteristics of hepatic hemangiomas in patients with normal, fibrotic and cirrhotic livers. MATERIALS AND METHODS: Retrospective, institutional review board approved study (waiver of informed consent). Eighty-nine consecutive patients with 231 hepatic hemangiomas who underwent liver MR imaging for lesion characterization were included. Lesions were classified into three groups according to the patients' liver condition: no underlying liver disease (group 1), fibrosis (group 2) and cirrhosis (group 3). Qualitative and quantitative characteristics (number, size, signal intensities on T1-, T2-, and DW MR images, T2 shine-through effect, enhancement patterns (classical, rapidly filling, delayed filling), and ADC values) were compared. RESULTS: There were 160 (69%), 45 (20%), and 26 (11%) hemangiomas in groups 1, 2 and 3, respectively. Lesions were larger in patients with normal liver (group 1 vs. groups 2 and 3; P=.009). No difference was found between the groups on T2-weighted images (fat-suppressed fast spin-echo (P=.82) and single-shot (P=.25)) and in enhancement patterns (P=.56). Mean ADC values of hemangiomas were similar between groups 1, 2 and 3 (2.11±.52×10(-3)mm(2)/s, 2.1±.53×10(-3)mm(2)/s and 2.14±.44×10(-3)mm(2)/s, P=87, respectively). T2 shine-through effect was less frequently observed in cirrhosis (P=.02). CONCLUSION: MR imaging characteristics of hepatic hemangioma were similar in patients with normal compared to fibrotic and cirrhotic livers. Smaller lesion size was observed with liver disease and less T2 shine-through effect was seen in hemangiomas developed on cirrhosis, the latter being an important finding to highlight in these patients at risk of developing hepatocellular carcinoma.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to determine the penetration of the thermal wave in the papaya fruit pulp (Carica papaya L.), cv. Golden, thermal diffusivity of the pulp was obtained measuring temperature at four different depths. Measurements were carried out initially with the fruit on the first stage of maturity. The changes of the thermal diffusivity were expressed as a function of ripening. A temporal decrease of the thermal diffusivity was observed. Chemical (pH, soluble solids and total titratable acidity) and physical (pulp firmness) properties were measured as well and the results were compared to the thermal diffusivity change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article provides expert opinion on the use of cardiovascular magnetic resonance (CMR) in young patients with congenital heart disease (CHD) and in specific clinical situations. As peculiar challenges apply to imaging children, paediatric aspects are repeatedly discussed. The first section of the paper addresses settings and techniques, including the basic sequences used in paediatric CMR, safety, and sedation. In the second section, the indication, application, and clinical relevance of CMR in the most frequent CHD are discussed in detail. In the current era of multimodality imaging, the strengths of CMR are compared with other imaging modalities. At the end of each chapter, a brief summary with expert consensus key points is provided. The recommendations provided are strongly clinically oriented. The paper addresses not only imagers performing CMR, but also clinical cardiologists who want to know which information can be obtained by CMR and how to integrate it in clinical decision-making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To determine whether a mono-, bi- or tri-exponential model best fits the intravoxel incoherent motion (IVIM) diffusion-weighted imaging (DWI) signal of normal livers. MATERIALS AND METHODS: The pilot and validation studies were conducted in 38 and 36 patients with normal livers, respectively. The DWI sequence was performed using single-shot echoplanar imaging with 11 (pilot study) and 16 (validation study) b values. In each study, data from all patients were used to model the IVIM signal of normal liver. Diffusion coefficients (Di ± standard deviations) and their fractions (fi ± standard deviations) were determined from each model. The models were compared using the extra sum-of-squares test and information criteria. RESULTS: The tri-exponential model provided a better fit than both the bi- and mono-exponential models. The tri-exponential IVIM model determined three diffusion compartments: a slow (D1 = 1.35 ± 0.03 × 10(-3) mm(2)/s; f1 = 72.7 ± 0.9 %), a fast (D2 = 26.50 ± 2.49 × 10(-3) mm(2)/s; f2 = 13.7 ± 0.6 %) and a very fast (D3 = 404.00 ± 43.7 × 10(-3) mm(2)/s; f3 = 13.5 ± 0.8 %) diffusion compartment [results from the validation study]. The very fast compartment contributed to the IVIM signal only for b values ≤15 s/mm(2) CONCLUSION: The tri-exponential model provided the best fit for IVIM signal decay in the liver over the 0-800 s/mm(2) range. In IVIM analysis of normal liver, a third very fast (pseudo)diffusion component might be relevant. KEY POINTS: ? For normal liver, tri-exponential IVIM model might be superior to bi-exponential ? A very fast compartment (D = 404.00 ± 43.7 × 10 (-3)  mm (2) /s; f = 13.5 ± 0.8 %) is determined from the tri-exponential model ? The compartment contributes to the IVIM signal only for b ≤ 15 s/mm (2.)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To preliminarily test the hypothesis that fluorine 19 ((19)F) magnetic resonance (MR) imaging enables the noninvasive in vivo identification of plaque inflammation in a mouse model of atherosclerosis, with histologic findings as the reference standard. MATERIALS AND METHODS: The animal studies were approved by the local animal ethics committee. Perfluorocarbon (PFC) emulsions were injected intravenously in a mouse model of atherosclerosis (n = 13), after which (19)F and anatomic MR imaging were performed at the level of the thoracic aorta and its branches at 9.4 T. Four of these animals were imaged repeatedly (at 2-14 days) to determine the optimal detection time. Repeated-measures analysis of variance with a Tukey test was applied to determine if there was a significant change in (19)F signal-to-noise ratio (SNR) of the plaques and liver between the time points. Six animals were injected with a PFC emulsion that also contained a fluorophore. As a control against false-positive results, wild-type mice (n = 3) were injected with a PFC emulsion, and atherosclerotic mice were injected with a saline solution (n = 2). The animals were sacrificed after the last MR imaging examination, after which high-spatial-resolution ex vivo MR imaging and bright-field and immunofluorescent histologic examination were performed. RESULTS: (19)F MR signal was detected in vivo in plaques in the aortic arch and its branches. The SNR was found to significantly increase up to day 6 (P < .001), and the SNR of all mice at this time point was 13.4 ± 3.3. The presence of PFC and plaque in the excised vessels was then confirmed both through ex vivo (19)F MR imaging and histologic examination, while no signal was detected in the control animals. Immunofluorescent histologic findings confirmed the presence of PFC in plaque macrophages. CONCLUSION: (19)F MR imaging allows the noninvasive in vivo detection of inflammation in atherosclerotic plaques in a mouse model of atherosclerosis and opens up new avenues for both the early detection of vulnerable atherosclerosis and the elucidation of inflammation mechanisms in atherosclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The energy demands of the brain are high: they account for at least 20% of the body's energy consumption. Evolutionary studies indicate that the emergence of higher cognitive functions in humans is associated with an increased glucose utilization and expression of energy metabolism genes. Functional brain imaging techniques such as fMRI and PET, which are widely used in human neuroscience studies, detect signals that monitor energy delivery and use in register with neuronal activity. Recent technological advances in metabolic studies with cellular resolution have afforded decisive insights into the understanding of the cellular and molecular bases of the coupling between neuronal activity and energy metabolism and point at a key role of neuron-astrocyte metabolic interactions. This article reviews some of the most salient features emerging from recent studies and aims at providing an integration of brain energy metabolism across resolution scales.