998 resultados para TITANIUM ELASTIC NAILS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the current work, two different coatings, nitrocarburised (CN) and titanium carbonitride (TiCN) on M2 grade high speed tool steel, were prepared by commercial diffusion and physical vapour deposition (PVD) techniques, respectively. Properties of the coating were characterised using a variety of techniques such as Glow-Discharge Optical Emission Spectrometry (GD-OES) and Scanning Electron Microscopy (SEM). Three non-commercial, oil-based lubricants with simplified formulations were used for this study. A tribological test was developed in which two nominally geometrically-identical crossed cylinders slide over each other under selected test conditions. This test was used to evaluate the effectiveness of a pre-applied lubricant film and a surface coating for various conditions of sliding wear. Engineered surface coatings can significantly improve wear resistance of the tool surface but their sliding wear performances strongly depend on the type of coating and lubricant combination used. These coating-lubricant interactions can also have a very strong effect on the useful life of the lubricant in a tribological system. Better performance of lubricants during the sliding wear testing was achieved hen used with the nitrocarburised (CN) coating. To understand the nature of the interactions and their possible effects on the coating-lubricant system, several surface analysis techniques were used. The molecular level investigation of Fourier Transform Infrared Spectroscopy (FTIR) revealed that oxidative degradation occurred in all used oil-based lubricants during the sliding wear test but the degradation behaviour of oil-based lubricants varied with the coating-lubricant system and the wear conditions. The main differences in the carbonyl oxidation region of the FTIR spectra (1900-1600 cm-1) between different coating-lubricant systems may relate to the effective lifetime of the lubricant during the sliding wear test. Secondary Ion Mass Spectrometry (SIMS) depth profiling shows that the CN coating has the highest lubricant absorbability among the tested tool surfaces. Diffusion of chlorine (C1), hydrogen (H) and oxygen (O) into the surface of subsurface of the tool suggested that strong interactions occurred between lubricant and tool surface during the sliding wear test. The possible effects of the interactions on the performance of whole tribological system are also discussed. The study of Time-of-Flight Secondary Ion Mass Spectrometry (TOF-SIMS) indicated that the envelope of hydrocarbons (CmHn) of oil lubricant in the positive TOF-SIMS spectra shifted to lower mass fragment after the sliding wear testing due to the breakage of long-chain hydrocarbons to short-chain ones during the degradation of lubricant. The shift of the mass fragment range of the hydrocarbon (CmHn) envelope caries with the type of both tool surface and lubricant, again confirming that variation in the performance of the tool-lubricant system relates to the changes in surface chemistry due to tribochemical interactions at the tool-lubricant interface under sliding wear conditions. The sliding wear conditions resulted in changes not only in topography of the tool surface due to mechanical interactions, as outlined in Chapter 5, but also in surface chemistry due to tribochemical interactions, as discussed in Chapters 6 and 7.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This thesis explores the elastic behaviour of the mechanical double action press and draw die system commonly used to draw sheet metal components in the automotive industry. High process variability in production and excessive time spent in die try-out are significant problems in automotive stamping. It has previously been suggested that the elastic behaviour of the system may contribute to these problems. However, the mechanical principles that cause the press system to affect the forming process have not been documented in detail. Due to a poor understanding of these problems in industry, the elasticity of the press and tools is currently not considered during the die design. The aim of this work was to explore the physical principles of press system elasticity and determine the extent to which it contributes to problems in try-out and production. On the basis of this analysis methods were developed for controlling or accounting for problems during the design process. The application of frictional restraining force to the edges of the blank during forming depends on the distribution and magnitude of the clamping force between the binders surfaces of the draw die. This is an important control parameter for the deep drawing process. It has been demonstrated in this work that the elasticity of the press and draw die can affect clamping force in two ways. The response of the press system, to the forces produced in the press during forming, causes the magnitude of clamping force to change during the stroke. This was demonstrated using measured data from a production press. A simple linear elastic model of the press system was developed to illustrate a definite link between the measured force variation and the elasticity of the press and tools. The simple model was extended into a finite element model of the complete press system, which was used to control a forming simulation. It was demonstrated that stiffness variation within the system could influence the final strains in a drawn part. At the conclusion of this investigation a method is proposed for assessing the sensitivity of a part to clamping force variation in the press during die design. A means of reducing variation in the press through the addition of a simple linear spring element is also discussed. The second part of the work assessed the influence of tool structure on the distribution of frictional restraining forces to the blank. A forming simulation showed that tool stiffness affects the distribution of clamping pressure between the binders. This was also shown to affect the final strains in a drawn part. However, the most significant influence on restraining force was the tendency of the blank to increase in thickness between the binders during forming. Using a finite element approximation of the try-out process it was shown that the structure of the tool would also contribute to the problems currently experienced in try-out where uneven contact pressure distributions are addressed by manually adjusting the tool surfaces. Finally a generalised approach to designing draw die structures was developed. Simple analysis methods were combined with finite element based topology optimisation techniques to develop a set of basic design guidelines. The aim of the guidelines was to produce a structure with uniform stiffness response to a pressure applied at the binder surface. The work concludes with a recommendation for introducing the methods developed in this thesis into the standard production process.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The importance of particle size in titanium (Ti) fabricated by powder metallurgy for the surface energy and its impact on the apatite formation was investigated. Four sorts of Ti powders of different mean particle size were realized through 20 min, 2 h, 5 h and 8 h of ball milling, respectively. Each sort of Ti powder was used to fabricate porous Ti and its nonporous counterparts sharing similar surface morphology, grain size and chemical composition, and then alkali-heat treatment was conducted on them. Surface energy was measured on the surfaces of the nonporous Ti counterparts due to the difficulty in measuring the porous surfaces directly. The surface energy increase on the alkali-heat-treated porous and nonporous Ti was observed due to the decrease in the particle size of the Ti powders and the presence of Ti–OH groups brought by the alkali-heat treatment. The apatite-inducing ability of the alkali-heat-treated porous and nonporous Ti with different surface energy values was evaluated in modified simulated body fluid and results indicated that there was a strong correlation between the apatite-inducing ability and the surface energy. The alkali-heat-treated porous and nonporous Ti discs prepared from the powders with an average particle size of 5.89 ± 0.76 μm possessed the highest surface energy and the best apatite-inducing ability when compared to the samples produced from the powders with the average particle size varying from 19.79 ± 0.31 to 10.25 ± 0.39 μm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in using titanium (Ti) alloys as load-bearing implant materials has increased due to their high strength to weight ratio, lower elastic modulus, and superior biocompatibility and enhanced corrosion resistance compared to conventional metals such as stainless steel and Co-Cr alloys. In the present study, the in vitro cytotoxicity of five binary titanium alloys, Ti15Ta, Ti15Nb, Ti15Zr, Ti15Sn and Ti15Mo, was assessed using human osteosarcoma cell line, SaOS-2 cells. The Cell proliferation and viability were determined, and cell adhesion and morphology on the surfaces of the binary Ti alloys after cell culture were observed by SEM. Results indicated that the Ti binary alloys of Ti15Ta, Ti15Nb and Ti15Zr exhibited the same level of excellent biocompatibility; Ti15Sn alloy exhibited a moderate biocompatibility while Ti15Mo alloy exhibited a moderate cytotoxicity. The SaOS-2 osteoblast-like cells had flattened and spread across the surfaces of the Ti15Ta, Ti15Nb, Ti15Zr and Ti15Sn groups; however, the cell shapes on the Ti15Mo alloy was shrinking and unhealthy. These results indicated that the Mo contents should be limited to a certain level in the design and development of new Ti alloys for implant material applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, titanium (Ti) samples were surface-modified by titania (TiO2), silica (SiO2) and hydroxyapatite (HA) coatings using a sol-gel process. The bioactivity of the film-coated Ti samples was investigated by cell attachment and morphology study using human osteoblast-like SaOS-2 cells. Results of the cell attachment indicated that the densities of cell attachment on the surfaces of Ti samples were significantly increased by film coatings; the density of cell attachment on HA film-coated surface was higher than those on TiO2 and SiO2 film-coated surfaces. Cell morphology study showed that the cells attached, spread and grew well on the three kinds of film-coated surfaces. It can be concluded that the three kinds of film coatings can bioactivate the surfaces of Ti samples effectively. Overall, Ti sample with HA film-coated surface exhibited the best bioactivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous titanium (Ti) and titanium alloys are promising scaffold biomaterials for bone tissue engineering, because they have the potential to provide new bone tissue ingrowth abilities and low elastic modulus to match that of
natural bone. In the present study, a new highly porous Ti6Ta4Sn alloy scaffold with the addition of biocompatible alloying elements (tantalum (Ta) and tin (Sn)) was prepared using a space-holder sintering method. The
strength of the Ti6Ta4Sn scaffold with a porosity of 75% was found to be significantly higher than that of a pure Ti scaffold with the same porosity. The elastic modulus of the porous alloy can be customized to match that of
human bone by adjusting its porosity. In addition, the porous Ti6Ta4Sn alloy exhibited an interconnected porous structure, which enabled the ingrowth of new bone tissues. Cell culture results revealed that human SaOS2
osteoblast-like cells grew and spread well on the surfaces of the solid alloy, and throughout the porous scaffold. The surface roughness of the alloy showed a significant effect on the cell behavior, and the optimum surface
roughness range for the adhesion of the SaOS2 cell on the alloy was 0.15 to 0.35 mm. The present study illustrated the feasibility of using the porous Ti6Ta4Sn alloy scaffold as an orthopedic implant material with a special
emphasis on its excellent biomechanical properties and in vitro biocompatibility with a high preference by osteoblast-like cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydroxyapatite (HA) was coated on the surface of a titanium-niobium (Ti-Nb) alloy by a sol-gel process. Triethyl phosphite and calcium nitrate were used as the phosphorus (P) and calcium (Ca) precursors respectively to prepare a Ca/P sol solution. The Ti-Nb alloy was dip-coated in the sol and heated at 600°C for 30 minutes. X-ray diffraction (XRD) analysis indicated the major phase constituent of the coating after heat treatment was HA. Scanning electron microscopy (SEM) observation showed that a few cracks were distributed on the HA coating. The in-vitro bioactivity of the HA coated Ti-Nb alloy was assessed using a cell culture of SaOS-2 osteoblast-like cells. The density of cell attachment was determined by MTT assay; the cell morphology was observed by SEM. Results indicated that the density of cell attachment on the surface of the Ti-Nb alloy was significantly increased by HA coating. Cell morphology observation showed that cells attached, spread and grew well on the HA coated surface. It can be concluded that the HA coating improved the in-vitro bioactivity of Ti-Nb alloy effectively.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Titanium (Ti) plates were firstly treated to form various types of oxide layers on the surface and then immersed into simulated body fluid (SBF) to evaluate the apatite forming ability. The surface morphology and roughness of the different oxide layers were measured by atomic force microscopy (AFM), and the surface energies were determined based on the Owens-Wendt (OW) methods. It was found that Ti samples after Alkali-Heat treatment (AH) achieved the best apatite formation after soaking in SBF for 3 weeks, compared to those without treatment, thermal or H2O2 oxidation. Furthermore, contact angle measurement revealed that the oxide layer on the alkali-heat treated Ti samples possessed the highest surface energy. The results indicate that the apatite inducing ability of a titanium oxide layer is linked to its surface energy. Apatite nucleation is easier on a surface with a higher surface energy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current orthopaedic biomaterials research mainly focuses on developing implants that could induce controlled, guided and rapid healing. In the present study, the surface morphologies of titanium (Ti) and niobium (Nb) metals were tailored to form nanoporous, nanoplate and nanofibrelike structures through adjustment of the temperature in the alkali treatment. The in vitro bioactivity of these structures was then evaluated by soaking in simulated body fluid (SBF). It was found that the morphology of the modified surface significantly influenced the apatite inducing ability. The Ti surface with a nanofiber-like structure showed better apatite inducing ability, than the nanoporous or nanoplate surface structures. A thick dense apatite layer formed on the Ti surface with nanofiberlike structure after 1 week soaking in SBF. It is expected that the anofibre-like surface could achieve good apatite formation in vivo and subsequently enhance osteoblast cell adhesion and bone formation in vivo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The transformation texture associated with martensite formation in the titanium alloy Ti- 6Al-4V has been investigated. Samples were heated into the fully b phase and quenched to form a microstructure of very fine a' martensite with no evidence of diffusional transformation at the prior b grain boundaries. EBSD texture measurements on the martensite showed that within each prior b grain, although typically all 12 variants of a’ were formed, the fractions of variants was far from uniform. The a’ texture was markedly different from values calculated using equal variant probability, also indicating that significant variant selection was occurring during martensitic transformation. This effect was modelled on the basis of elastic interaction between martensite events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Porous titanium with a porosity of 75% was fabricated by space-holder sintering through powder metallurgy. The effect of the alkali and heat treatment on the strength of the porous titanium was investigated. Results indicated that the alkali and heat treatment led to a significant decrease in the strength of the porous titanium, whichwas causedby the degradation due to corrosion of the struts of the porous titanium with a layer of the reaction products, grain pullout and micro-cracks.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report an Mg-based metallic glass/titanium interpenetrating phase composite in which constituent phases form a homogeneously interconnected network. The porous titanium constrains shear bands propagation thoroughly and promotes shear bands branching and intersection subsequently. The homogeneous phase distribution promotes regularly distributed local shear deformation and leads to a uniform deformation for the composites. Moreover, the interpenetrating phase structure introduces a mutual-reinforcement between metallic glass and titanium. Therefore, the composite exhibits excellent mechanical performance with compressive fracture strength of 1783 MPa and fracture strain of 31%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present study, porous Ti–10Nb–10Zr alloy scaffolds with different porosities were successfully fabricated by a ‘‘space-holder” sintering method. By the addition of biocompatible alloying elements the porous TiNbZr scaffolds achieved significantly higher strength than unalloyed Ti scaffolds of the same porosity. In particular, the porous TiNbZr alloy with 59% porosity exhibited an elastic modulus and plateau stress of 5.6 GPa and 137 MPa, respectively. The porous alloys exhibited excellent ductility during compression tests and the deformation mechanism is mainly governed by bending and buckling of the struts. Cell cultures revealed that SaOS2 osteoblast-like cells grew on the surface and inside the pores and showed good spreading. Cell viability for the porous scaffold was three times higher than the solid counterpart. The present study has demonstrated that the porous TiNbZr alloy scaffolds are promising scaffold biomaterials for
bone tissue engineering by virtue of their appropriate mechanical properties, highly porous structure and excellent biocompatibility.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work investigated the structure and properties relationship, surface modification, biocompatibility and bioactivity of a porous Ti-Nb-Zr alloy. The porous alloy exhibited inter-connected porous structure, good biocompatibility and high mechanical strength with an elastic modulus close to that of bone. Porous Ti-Nb-Zr alloys are thus promising biomaterials for hard tissue replacement.