947 resultados para Synchronized intermittent mandatory ventilation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The benefits of prone position ventilation are well demonstrated in the severe forms of acute respiratory distress syndrome, but not in the milder forms. We investigated the effects of prone position on arterial blood gases, lung inflammation, and histology in an experimental mild acute lung injury (ALI) model. ALI was induced in Wistar rats by intraperitoneal Escherichia coli lipopolysaccharide (LPS, 5 mg/kg). After 24 h, the animals with PaO2/FIO2 between 200 and 300 mmHg were randomized into 2 groups: prone position (n = 6) and supine position (n = 6). Both groups were compared with a control group (n = 5) that was ventilated in the supine position. All of the groups were ventilated for 1 h with volume-controlled ventilation mode (tidal volume = 6 ml/kg, respiratory rate = 80 breaths/min, positive end-expiratory pressure = 5 cmH2O, inspired oxygen fraction = 1). Significantly higher lung injury scores were observed in the LPS-supine group compared to the LPS-prone and control groups (0.32 ± 0.03; 0.17 ± 0.03 and 0.13 ± 0.04, respectively) (p < 0.001), mainly due to a higher neutrophil infiltration level in the interstitial space and more proteinaceous debris that filled the airspaces. Similar differences were observed when the gravity-dependent lung regions and non-dependent lung regions were analyzed separately (p < 0.05). The BAL neutrophil content was also higher in the LPS-supine group compared to the LPS-prone and control groups (p < 0.05). There were no significant differences in the wet/dry ratio and gas exchange levels. In this experimental extrapulmonary mild ALI model, prone position ventilation for 1 h, when compared with supine position ventilation, was associated with lower lung inflammation and injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intermittent stream systems create a mosaic of aquatic habitat that changes through time, potentially challenging freshwater invertebrate dispersal. Invertebrates inhabiting these mosaics may show stronger dispersal capacity than those in perennial stream systems. To relate different combinations of dispersal and drought survival strategies to species persistence, we compared the distribution and dispersal potential of six invertebrate species across all streams in a montane landscape where drying is becoming increasingly frequent and prolonged. Invertebrates were collected from seventeen streams in the Victoria Range, Grampians National Park, Victoria, Australia. The species analysed were as follows: the caddisflies Lectrides varians Moseley (Leptoceridae) and Agapetus sp. (Glossosomatidae); the mayflies Nousia AV1 and Koorrnonga AV3 (Leptophlebiidae); the water penny beetle Sclerocyphon sp. (Psephenidae); and a freshwater crayfish Geocharax sp. nov. 1 (Parastacidae). These species were widespread in the streams and varied in their dispersal and drought survival strategies. The distribution of each species across the Victoria Range, their drought responses and within-stream habitat associations were determined. Hypotheses of the dispersal capacity and population structure for each species were developed and compared to four models of gene flow: Death Valley Model (DVM), Stream Hierarchy Model (SHM), Headwater Model (HM) or panmixia (PAN). Molecular genetic methods were then used to infer population structure and dispersal capacity for each species. The large caddisfly Lectrides resisted drought through aestivation and was panmictic (PAN) indicating strong dispersal capacity. Conversely, the small caddisfly Agapetus relied on perennially flowing reaches and gene flow was limited to short distances among stream headwaters, resembling the HM. Both mayflies depended on perennial surface water during drying and showed evidence of gene flow among streams: Koorrnonga mainly dispersed along stream channels within catchments, resembling the SHM, whereas Nousia appeared to disperse across land by adult flight. Sclerocyphon relied on perennial water to survive drying and showed an unusual pattern of genetic structure that indicated limited dispersal but did not resemble any of the models. Geocharax survived drought through aestivation or residence in perennial pools, and high levels of genetic structure indicated limited dispersal among streams, resembling the DVM. Despite good knowledge of species' drought survival strategies, the population structure of four species differed from predictions. Dispersal capacity varied strongly among species; most species were poor dispersers and only one species showed panmixia. Therefore, intermittent stream species may not necessarily be better dispersers than those in perennial streams. Species showing strong drought resistance strategies differed in dispersal capacity. Knowledge of life-history characteristics, distribution and refuge use does not necessarily enable successful prediction of invertebrate dispersal pathways or population structure. Dispersal among intermittent streams may be restricted to relatively short distances (km) for most invertebrate species. Thus, frequent drought refuges (perennial water) that provide strong connectivity to subpopulations through stream flow (hydrological dispersal), or continuous terrestrial vegetation (flight dispersal), will be critical to maintain genetic diversity, adaptability and population persistence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Child abuse is not a new phenomenon. The abuse and neglect of children has been documented for more than two thousand years. However, attempts to prevent child abuse are relatively new.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La ventilation liquidienne totale (VLT) consiste à remplir les poumons d'un liquide perfluorocarbone (PFC). Un respirateur liquidien assure la ventilation par un renouvellement cyclique de volume courant de PFC oxygéné et à température contrôlée. Ayant une capacité thermique volumique 1665 fois plus élevée que l'air, le poumon rempli de PFC devient un échangeur de chaleur performant avec la circulation pulmonaire. La température du PFC inspiré permet ainsi de contrôler la température artérielle, et par le fait même, le refroidissement des organes et des tissus. Des résultats récents d'expérimentations animales sur petits animaux ont démontré que le refroidissement ultra-rapide par VLT hypothermisante (VLTh) avait d'importants effets neuroprotecteurs et cardioprotecteurs. Induire rapidement et efficacement une hypothermie chez un patient par VLTh est une technique émergente qui suscite de grands espoirs thérapeutiques. Par contre, aucun dispositif approuvé pour la clinique n'est disponible et aucun résultat de VLTh sur humain n'est encore disponible. Le problème se situe dans le fait de contrôler la température du PFC inspiré de façon optimale pour induire une hypothermie chez l'humain tout en s'assurant que la température cardiaque reste supérieure à 30 °C pour éviter tout risque d'arythmie. Cette thèse présente le développement d'un modèle thermique paramétrique d'un sujet en VLTh complètement lié à la physiologie. Aux fins de validation du modèle sur des ovins pédiatriques et adultes, le prototype de respirateur liquidien Inolivent pour nouveau-né a dû être reconçu et adapté pour ventiler de plus gros animaux. Pour arriver à contrôler de façon optimale la température du PFC inspiré, un algorithme de commande optimale sous-contraintes a été développé. Après la validation du modèle thermique du nouveau-né à l'adulte par expérimentations animales, celui-ci a été projeté à l'humain. Afin de réduire le temps de calcul, un passage du modèle thermique en temps continu vers un modèle discret cycle-par-cycle a été effectué. À l'aide de la commande optimale et du développement numérique d'un profil de ventilation liquidienne chez des patients humains, des simulations d'induction d'hypothermie par VLTh ont pu être réalisées. La validation expérimentale du modèle thermique sur ovins nouveau-nés (5 kg), juvéniles (22 kg) et adultes (61 kg) a montré que celui-ci permettait de prédire les températures artérielles systémiques, du retour veineux et rectales. La projection à l'humain a permis de démontrer qu'il est possible de contrôler la température du PFC de façon optimale en boucle ouverte si le débit cardiaque et le volume mort thermique sont connus. S'ils ne peuvent être mesurés, la commande optimale pour le pire cas peut être calculée rendant l'induction d'hypothermie par VLTh sécuritaire pour tous les patients, mais diminuant quelque peu les vitesses de refroidissement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changing the traditional pattern of public procurement for an electronic paradigm is a radical innovation involving major organizational changes, the breaking up of traditional processes and practices, obsolescence of knowledge and skills. Going beyond the European Commission's recommendations, in 2009 Portugal pioneered in making e-procurement mandatory in the pre-award phase, in a European context of multiple technical standards and lack of interoperability of electronic platforms across the EU countries. Six years later, when the creation of a European e-procurement single market is a EU mission and a major legislative amendment is underway in Portugal, this study looks at the relationship between e-procurement and innovation in the Portuguese municipalities aiming to understand the extent into which the adoption of e-procurement embraced a real organizational change or, on the other hand, if it just represented a mere adaptation of the usual procurement practices. The study draws on data from an electronic survey to all municipalities in mainland Portugal and the analysis is mainly descriptive and exploratory. The paradigm shift in public procurement involves major organizational changes but, overall, the results suggest that most municipalities do not have a clear understanding of the innovative scope (depth and diversity) implied by e-procurement. E-procurement shows advantages over the paper-based model but an unbalanced perception of the innovation dimensions has influenced the implementation of e-procurement and the degree of organizational change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The past few decades have seen major impacts of different pandemics and mass casualty events on health resource use in terms of rising health cost and increased mortality.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

What role can climatically appropriate subdivision design play in decreasing the use of energy required to cool premises by maximising access to natural ventilation? How can this design be achieved? The subdivision design stage is critical to urban and suburban sustainability outcomes, as significant changes after development are constrained by the configuration of the subdivision, and then by the construction of the dwellings. Existing Australian lot rating methodologies for energy efficiency, such as that by the Sustainable Energy Development Authority (SEDA), focus on reducing heating needs by increasing solar access, a key need in Australia’s temperate zone. A recent CRC CI project, Sustainable Subdivisions: Energy (Miller and Ambrose 2005) examined these guidelines to see if they could be adapted for use in subtropical South East Queensland (SEQ). Correlating the lot ratings with dwelling ratings, the project found that the SEDA guidelines would need to be modified for use to make allowance for natural ventilation. In SEQ, solar access for heating is less important than access to natural ventilation, and there is a need to reduce energy used to cool dwellings. In Queensland, the incidence of residential air-conditioning was predicted to reach 50 per cent by the end of 2005 (Mickel 2004). The CRC-CI, Sustainable Subdivisions: Ventilation Project (CRC-CI, in progress), aims to verify and quantify the role natural ventilation has in cooling residences in subtropical climates and develop a lot rating methodology for SEQ. This paper reviews results from an industry workshop that explored the current attitudes and methodologies used by a range of professionals involved in subdivision design and development in SEQ. Analysis of the workshop reveals that a key challenge for sustainability is that land development in subtropical SEQ is commonly a separate process from house design and siting. Finally, the paper highlights some of the issues that regulators and industry face in adopting a lot rating methodology for subdivisions offering improved ventilation access, including continuing disagreement between professionals over the desirability of rating tools.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Health Information Systems (HIS) make extensive use of Information and Communication Technologies (ICT). The use of ICT aids in improving the quality and efficiency of healthcare services by making healthcare information available at the point of care (Goldstein, Groen, Ponkshe, and Wine, 2007). The increasing availability of healthcare data presents security and privacy issues which have not yet been fully addressed (Liu, Caelli, May, and Croll, 2008a). Healthcare organisations have to comply with the security and privacy requirements stated in laws, regulations and ethical standards, while managing healthcare information. Protecting the security and privacy of healthcare information is a very complex task (Liu, May, Caelli and Croll, 2008b). In order to simplify the complexity of providing security and privacy in HIS, appropriate information security services and mechanisms have to be implemented. Solutions at the application layer have already been implemented in HIS such as those existing in healthcare web services (Weaver et al., 2003). In addition, Discretionary Access Control (DAC) is the most commonly implemented access control model to restrict access to resources at the OS layer (Liu, Caelli, May, Croll and Henricksen, 2007a). Nevertheless, the combination of application security mechanisms and DAC at the OS layer has been stated to be insufficient in satisfying security requirements in computer systems (Loscocco et al., 1998). This thesis investigates the feasibility of implementing Security Enhanced Linux (SELinux) to enforce a Role-Based Access Control (RBAC) policy to help protect resources at the Operating System (OS) layer. SELinux provides Mandatory Access Control (MAC) mechanisms at the OS layer. These mechanisms can contain the damage from compromised applications and restrict access to resources according to the security policy implemented. The main contribution of this research is to provide a modern framework to implement and manage SELinux in HIS. The proposed framework introduces SELinux Profiles to restrict access permissions over the system resources to authorised users. The feasibility of using SELinux profiles in HIS was demonstrated through the creation of a prototype, which was submitted to various attack scenarios. The prototype was also subjected to testing during emergency scenarios, where changes to the security policies had to be made on the spot. Attack scenarios were based on vulnerabilities common at the application layer. SELinux demonstrated that it could effectively contain attacks at the application layer and provide adequate flexibility during emergency situations. However, even with the use of current tools, the development of SELinux policies can be very complex. Further research has to be made in order to simplify the management of SELinux policies and access permissions. In addition, SELinux related technologies, such as the Policy Management Server by Tresys Technologies, need to be researched in order to provide solutions at different layers of protection.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research thesis focuses on the experiences of pre-service drama teachers and considers how process drama may assist them to reflect on key aspects of professional ethics such as mandatory codes or standards, principled moral reasoning, moral character, moral agency, and moral literacy. Research from higher education provides evidence that current pedagogical approaches used to prepare pre –professionals for practice in medicine, engineering, accountancy, business, psychology, counselling, nursing and education, rarely address the more holistic or affective dimensions of professional ethics such as moral character. Process drama, a form of educational drama, is a complex improvisational group experience that invites participants to create and assume roles, and select and manage symbols in order to create a fictional world exploring human experience. Many practitioners claim that process drama offers an aesthetic space to develop a deeper understanding of self and situations, expanding the participant’s consciousness and ways of knowing. However, little research has been conducted into the potential efficacy of process drama in professional ethics education for pre-professionals. This study utilizes practitioner research and case study to explore how process drama may contribute to the development of professional ethics education and pedagogy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mandatory numeracy tests have become commonplace in many countries, heralding a new era in school assessment. New forms of accountability and an increased emphasis on national and international standards (and benchmarks) have the potential to reshape mathematics curricula. It is noteworthy that the mathematics items used in these tests are rich in graphics. Many of the items, for example, require students to have an understanding of information graphics (e.g., maps, charts and graphs) in order to solve the tasks. This investigation classifies mathematics items in Australia’s inaugural national numeracy tests and considers the effect such standardised testing will have on practice. It is argued that the design of mathematics items are more likely to be a reliable indication of student performance if graphical, linguistic and contextual components are considered both in isolation and in integrated ways as essential elements of task design.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Chronic wounds are a significant socioeconomic problem for governments worldwide. Approximately 15% of people who suffer from diabetes will experience a lower-limb ulcer at some stage of their lives, and 24% of these wounds will ultimately result in amputation of the lower limb. Hyperbaric Oxygen Therapy (HBOT) has been shown to aid the healing of chronic wounds; however, the causal reasons for the improved healing remain unclear and hence current HBOT protocols remain empirical. Here we develop a three-species mathematical model of wound healing that is used to simulate the application of hyperbaric oxygen therapy in the treatment of wounds. Based on our modelling, we predict that intermittent HBOT will assist chronic wound healing while normobaric oxygen is ineffective in treating such wounds. Furthermore, treatment should continue until healing is complete, and HBOT will not stimulate healing under all circumstances, leading us to conclude that finding the right protocol for an individual patient is crucial if HBOT is to be effective. We provide constraints that depend on the model parameters for the range of HBOT protocols that will stimulate healing. More specifically, we predict that patients with a poor arterial supply of oxygen, high consumption of oxygen by the wound tissue, chronically hypoxic wounds, and/or a dysfunctional endothelial cell response to oxygen are at risk of nonresponsiveness to HBOT. The work of this paper can, in some way, highlight which patients are most likely to respond well to HBOT (for example, those with a good arterial supply), and thus has the potential to assist in improving both the success rate and hence the costeffectiveness of this therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background The accurate measurement of Cardiac output (CO) is vital in guiding the treatment of critically ill patients. Invasive or minimally invasive measurement of CO is not without inherent risks to the patient. Skilled Intensive Care Unit (ICU) nursing staff are in an ideal position to assess changes in CO following therapeutic measures. The USCOM (Ultrasonic Cardiac Output Monitor) device is a non-invasive CO monitor whose clinical utility and ease of use requires testing. Objectives To compare cardiac output measurement using a non-invasive ultrasonic device (USCOM) operated by a non-echocardiograhically trained ICU Registered Nurse (RN), with the conventional pulmonary artery catheter (PAC) using both thermodilution and Fick methods. Design Prospective observational study. Setting and participants Between April 2006 and March 2007, we evaluated 30 spontaneously breathing patients requiring PAC for assessment of heart failure and/or pulmonary hypertension at a tertiary level cardiothoracic hospital. Methods SCOM CO was compared with thermodilution measurements via PAC and CO estimated using a modified Fick equation. This catheter was inserted by a medical officer, and all USCOM measurements by a senior ICU nurse. Mean values, bias and precision, and mean percentage difference between measures were determined to compare methods. The Intra-Class Correlation statistic was also used to assess agreement. The USCOM time to measure was recorded to assess the learning curve for USCOM use performed by an ICU RN and a line of best fit demonstrated to describe the operator learning curve. Results In 24 of 30 (80%) patients studied, CO measures were obtained. In 6 of 30 (20%) patients, an adequate USCOM signal was not achieved. The mean difference (±standard deviation) between USCOM and PAC, USCOM and Fick, and Fick and PAC CO were small, −0.34 ± 0.52 L/min, −0.33 ± 0.90 L/min and −0.25 ± 0.63 L/min respectively across a range of outputs from 2.6 L/min to 7.2 L/min. The percent limits of agreement (LOA) for all measures were −34.6% to 17.8% for USCOM and PAC, −49.8% to 34.1% for USCOM and Fick and −36.4% to 23.7% for PAC and Fick. Signal acquisition time reduced on average by 0.6 min per measure to less than 10 min at the end of the study. Conclusions In 80% of our cohort, USCOM, PAC and Fick measures of CO all showed clinically acceptable agreement and the learning curve for operation of the non-invasive USCOM device by an ICU RN was found to be satisfactorily short. Further work is required in patients receiving positive pressure ventilation.