958 resultados para Super-elasticity
Resumo:
Chronic pain has been often associated with myofascial pain syndrome (MPS), which is determined by myofascial trigger points (MTrP). New features have been tested for MTrP diagnosis. The aim of this study was to evaluate two-dimensional ultrasonography (2D US) and ultrasound elastography (UE) images and elastograms of upper trapezius MTrP during electroacupuncture (EA) and acupuncture (AC) treatment. 24 women participated, aged between 20 and 40 years (M ± SD = 27.33 ± 5.05) with a body mass index ranging from 18.03 to 27.59 kg/m2 (22.59 ± 3.11), a regular menstrual cycle, at least one active MTrP at both right (RTPz) and left trapezius (LTPz) and local or referred pain for up to six months. Subjects were randomized into EA and AC treatment groups and the control sham AC (SHAM) group. Intensity of pain was assessed by visual analogue scale; MTrP mean area and strain ratio (SR) by 2D US and UE. A significant decrease of intensity in general, RTPz, and LTPz pain was observed in the EA group (p = 0.027; p < 0.001; p = 0.005, respectively) and in general pain in the AC group (p < 0.001). Decreased MTrP area in RTPz and LTPz were observed in AC (p < 0.001) and EA groups (RTPz, p = 0.003; LTPz, p = 0.005). Post-treatment SR in RTPz and LTPz was lower than pre-treatment in both treatment groups. 2D US and UE effectively characterized MTrP and surrounding tissue, pointing to the possibility of objective confirmation of subjective EA and AC treatment effects.
Resumo:
Cardboard packing for horticultural products has as main function to protect them. The design of a cardboard packing request the knowledge of the bending stiffens which is depending on the modulus of elasticity. The objective of this work was to calculate the cardboard modulus of elasticity from data obtained in laboratory using physical characterization test, with different methods, and comparing the results with the values obtained experimentally. Ten samples of each cardboard selected for this study were tested in the paper fabrication direction and in its transverse direction. The papers liner and medium resistance to the traction, used to calculate the bending stiffness, was determined in a universal machine test. To obtaining of the bending stiffens the four points test was accomplished. Expressive variations among the methods from which the modulus of elasticity is obtained were observed and that influence the bending stiffness of the structure. The stiffness values obtained experimentally were always greater than the values obtained from analytical method. This difference can be attributed to two factors, the production processes that assurance a larger rigidity than the components separately and the addition of the adhesive layer that is not taken in consideration in the analytic calculations.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
OBJETIVO: esta pesquisa objetivou avaliar cefalometricamente as alterações dentoesqueléticas de jovens com Classe II dentária tratados com o distalizador Jones jig. METODOLOGIA: foram avaliados 30 pacientes, sendo 15 de cada gênero, com média de idades iniciais de 13,63 anos; brasileiros, naturais da cidade de Bauru/SP, caracterizados por má oclusão de Classe II, 1ª e 2ª divisões de Angle sem comprometimento esquelético. Os jovens foram tratados com aparelho Jones jig a fim de distalizar os molares superiores a uma relação molar de "super Classe I"; sendo que esse dispositivo permaneceu, em média, por 0,55 anos. Ao final da sobrecorreção, os molares distalizados receberam um botão de Nance e, como ancoragem extrabucal, o aparelho extrabucal (AEB) com tração média-alta, com o intuito de verticalizar e corrigir a angulação radicular dos molares distalizados. Foram realizadas telerradiografias em normal lateral inicial (T1) e pós-distalização (T2). As medidas cefalométricas foram submetidas ao teste t dependente de Student para avaliar as alterações de T1 para T2. RESULTADOS: com base nos resultados obtidos e a partir da metodologia empregada, observou-se alterações dentárias significativas, como a movimentação distal linear e angular, assim como a intrusão dos segundos e primeiros molares superiores no sentido vertical. Também se confirmou efeitos indesejáveis, como a perda de ancoragem refletida em mesialização, extrusão e angulação mesial dos segundos pré-molares, a protrusão dos incisivos superiores e o aumento do trespasse vertical e horizontal. Pode-se confirmar que certas movimentações dentárias promovem significativas alterações esqueléticas de estruturas localizadas à distância, ou seja, observou-se extrusão significativa dos segundos pré-molares superiores, o que resultou em rotação mandibular, aumento significativo da altura facial anteroinferior e protrusão do lábio inferior. CONCLUSÃO: pode-se concluir que o distalizador Jones jig promove, basicamente, alterações dentárias.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, frequently hinder the development of clinical trials. The purpose of this in vitro study was to determine the modulus of elasticity of a polyurethane isotropic experimental model via tension tests, comparing the results to those reported in the literature for mandibular bone, in order to validate the use of such a model in lieu of mandibular bone in biomechanical studies. MATERIAL AND METHODS: Forty-five polyurethane test specimens were divided into 3 groups of 15 specimens each, according to the ratio (A/B) of polyurethane reagents (PU-1: 1/0.5, PU-2: 1/1, PU-3: 1/1.5). RESULTS: Tension tests were performed in each experimental group and the modulus of elasticity values found were 192.98 MPa (SD=57.20) for PU-1, 347.90 MPa (SD=109.54) for PU-2 and 304.64 MPa (SD=25.48) for PU-3. CONCLUSION: The concentration of choice for building the experimental model was 1/1.
Resumo:
OBJECTIVES: The complexity and heterogeneity of human bone, as well as ethical issues, most always hinder the performance of clinical trials. Thus, in vitro studies become an important source of information for the understanding of biomechanical events on implant-supported prostheses, although study results cannot be considered reliable unless validation studies are conducted. The purpose of this work was to validate an artificial experimental model based on its modulus of elasticity, to simulate the performance of human bone in vivo in biomechanical studies of implant-supported prostheses. MATERIAL AND METHODS: In this study, fast-curing polyurethane (F16 polyurethane, Axson) was used to build 40 specimens that were divided into five groups. The following reagent ratios (part A/part B) were used: Group A (0.5/1.0), Group B (0.8/1.0), Group C (1.0/1.0), Group D (1.2/1.0), and Group E (1.5/1.0). A universal testing machine (Kratos model K - 2000 MP) was used to measure modulus of elasticity values by compression. RESULTS: Mean modulus of elasticity values were: Group A - 389.72 MPa, Group B - 529.19 MPa, Group C - 571.11 MPa, Group D - 470.35 MPa, Group E - 437.36 MPa. CONCLUSION: The best mechanical characteristics and modulus of elasticity value comparable to that of human trabecular bone were obtained when A/B ratio was 1:1.
Resumo:
Fluorinated denture base acrylic resins can present more stable physical properties when compared with conventional polymers. This study evaluated the incorporation of a fluoroalkyl methacrylate (FMA) mixture in a denture base material and its effect on roughness and flexural strength. A swelling behavior assessment of acrylic resin specimens (n=3, per substance) after 12 h of FMA or methyl methacrylate (MMA) immersion was conducted to determine the solvent properties. Rectangular specimens (n=30) were allocated to three groups, according to the concentration of FMA substituted into the monomer component of a heat-polymerized acrylic resin (Lucitone 550), as follows: 0% (control), 10% and 20% (v/v). Acrylic resin mixed with concentrations of 25% or more did not reach the dough stage and was not viable. The surface roughness and flexural strength of the specimens were tested. Variables were analyzed by ANOVA and Tukey's test (a=0.05). Immersion in FMA produced negligible swelling, and MMA produced obvious swelling and dissolution of the specimens. Surface roughness at concentrations of 0%, 10% and 20% were: 0.25 ± 0.04, 0.24 ± 0.04, 0.22 ± 0.03 mm (F=1.78; p=0.189, not significant). Significant differences were found for flexural strength (F=15.92; p<0.001) and modulus of elasticity (F=7.67; p=0.002), with the following results: 96 ± 6, 82 ± 5, 84 ± 6 MPa, and 2,717 ± 79, 2,558 ± 128, 2574 ± 87 MPa, respectively. The solvent properties of FMA against acrylic resin are weak, which would explain why concentrations over 20% were not viable. Surface changes were not detected after the incorporation of FMA in the denture base acrylic resin tested. The addition of FMA into denture base resin may lower the flexural strength and modulus of elasticity, regardless of the tested concentration.
Resumo:
This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)- 100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.
Resumo:
The aims of this study were to evaluate the incidence of mutans streptococci (MS - sessile form) on complete maxillary dentures after use of a specific denture paste, and to determine the minimum inhibitory concentration (MIC) and maximum inhibitory dilution (MID) of 3 oral mouthrinses: Cepacol, Plax and Periogard. Seventy-seven complete denture wearers were randomly assigned into 2 groups, according to the product used for denture cleaning: Control group - conventional dentifrice (Kolynos-Super White); and Test group: experimental denture cleaning paste. Denture biofilm was collected at baseline and after 90 and 180 days after treatment by brushing the dentures with saline solution. After decimal serial dilution, samples were seeded onto agar sucrose bacitracin to count colonies with morphological characteristics of MS. MS identification was performed by the sugar fermentation tests. After this procedure, brain heart infusion broth (BHI) was added to oral mouthrinses (Plax, Cepacol e Periogard) and seeded on Petri dishes. The colonies were seeded using the Steers multiplier and, after the incubation, the MIC and MID of the mouthrinses were calculated. The results showed an incidence of 74.0% (n=57) of MS in the 77 complete dentures examined in the study, being 76.3% (n=29) of the Control group (conventional dentifrice) and 71.8% (28) of the Test group (experimental denture cleaning paste). In both groups, the number of positive cases for MS decreased from day 0 to day 180. In the Test group there was a slight decrease in the incidence of Streptococcus mutans 90 days after use of the experimental denture cleaning paste, which was not observed in the Control group. As regards to mouthrinses, for both groups, Periogard showed antimicrobial action with the highest dilution, followed by Cepacol and Plax. In conclusion, the incidence of MS in complete dentures was high and Periogard was the mouthrinse with the strongest antimicrobial action against MS. The experimental denture cleaning paste showed a slight action against S. mutans after 90 days of treatment.
Resumo:
With the increase in life expectancy, biomaterials have become an increasingly important focus of research because they are used to replace parts and functions of the human body, thus contributing to improved quality of life. In the development of new biomaterials, the Ti-15Mo alloy is particularly significant. In this study, the Ti-15Mo alloy was produced using an arc-melting furnace and then characterized by density, X-ray diffraction, optical microscopy, hardness and dynamic elasticity modulus measurements, and cytotoxicity tests. The microstructure was obtained with β predominance. Microhardness, elasticity modulus, and cytotoxicity testing results showed that this material has great potential for use as biomaterial, mainly in orthopedic applications.
Resumo:
Edible films are thin materials based on biopolymers and food additives. The aim of this work is a review on the application of dynamic mechanical analysis in edible film technology. After a brief review of the linear visco-elasticity theory, a description of some practical aspects related to dynamic mechanical analysis, such as sample fixation and sample dehydration during analysis and types and modes of tests are presented. Thus, the use of temperature scanning analysis for glass transition and for plasticizer-biopolymer compatibility studies and frequency scanning tests, less common in edible film technology, are critically reviewed.
Resumo:
Avaliaram-se as características fermentativas e a qualidade das silagens de seis variedades de milho, de ciclos precoce e superprecoce - BRS Caatingueiro, BRS Assum Preto, BR 5033 Asa Branca, BR 5028 São Francisco, Gurutuba e BRS 4103 - indicadas para a região semiárida brasileira. Foram utilizados silos experimentais, em delineamento inteiramente ao acaso, com seis tratamentos (variedades) e quatro repetições. Avaliaram-se: matéria seca (MS), matéria orgânica (MO), proteína bruta (PB), fibra em detergente neutro (FDN), fibra em detergente ácido (FDA), extrato etéreo (EE), carboidratos totais (CHO), carboidratos não fibrosos (CNF), pH, nitrogênio amoniacal como parte do nitrogênio total (N-NH3/NT), ácidos orgânicos e digestibilidade in vitro da matéria seca (DIVMS) das silagens. Os valores médios encontrados para a silagem foram: MS= 28,7%; MO= 94,9%; PB= 8,3%; FDN= 49,9%; FDA= 27,5%; EE= 3,8%; CHO= 82,7%; CNF= 32,8%; pH= 3,8; N-NH3/NT= 2,9%/NT; ácido láctico = 7,6%; ácido acético = 0,6%; ácido butírico = 0,3% e DIVMS= 57,9%. As variedades BR 5028 - São Francisco e Gurutuba destacaram-se das demais em relação ao teor de matéria seca. A variedade BRS Caatingueiro apresentou maior teor de carboidratos não fibrosos em relação às demais. As silagens de todas as variedades foram classificadas como de excelente qualidade, por apresentarem potencial para ensilagem no semiárido brasileiro