999 resultados para Stationary processes


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review article summarizes the variety of polar stationary phases that have been employed for capillary electrochromatographic separations. Compared with reversed-phase stationary phases, the polar alternatives provide a completely different retention selectivity towards polar and charged analytes. Different types of polar stationary phases are reviewed, including the possible retention mechanisms. Electrochromato-graphic separations of polar solutes, peptides, and basic pharmaceuticals on polar stationary phases are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cellulose trisphenylcarbamate-bonded chiral stationary phase was applied to nano-liquid chromatography (nano-LC) and capillary electrochromatography (CEC) with nonaqueous and aqueous solutions as the mobile phases. Several chiral compounds were successfully resolved on the prepared phase by nano-LC. The applicability of nonaqueous CEC on a cellulose derivative stationary phase was investigated with the organic solvents methanol, hexane, 2-propanol, and tetrahydrofuran (THF) containing acetic acid, as well as triethylamine as the mobile phases. Enantiomers of warfarin and praziquantel were baseline-resolved with plate numbers of 82 300 and 38 800 plates/m, respectively, for the first eluting enantiomer. The influence of applied voltage, concentration of nonpolar solvent, apparent pH, and buffer concentration in the mobile phase on the electroosmotic flow (EOF) and the mobility of the enantiomers was evaluated. Enantioseparations of traps-stilbene oxide and praziquantel were also achieved in aqueous CEC with plate numbers of 111 100 and 107 400 plates/m, respectively, for the first eluting enantiomer. A comparison between nonaqueous CEC and aqueous CEC based on a cellulose trisphenylcarbamate stationary phase was discussed. Pressure-assisted CEC was examined for the chiral separation of praziquantel and faster analysis with high enantioselectivity was acquired with the proper pressurization of the inlet vial.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Positively charged chiral stationary phases (CSPs) were prepared for capillary electrochromatography (CEC) separation of enantiomers by chemically immobilizing cellulose derivatives onto diethylenetriaminopropylated silica (DEAPS) with tolylene-2,4-diisocyanate (TDI) as a spacer reagent. Anodic electroosmotic mobility was observed in both nonaqueous and aqueous mobile phases due to the positively charged amines on the surface of the prepared CSPs. For comparison, the traditionally used 3-aminopropyl silica (APS) was also adopted as the base material instead of DEAPS to prepare CSP. It was observed that the EOF on the DEAPS-based CSP was 18%-60% higher than that on the APS-based CSP under nonaqueous mobile phase conditions. Separation of enantiomers in CEC was performed on the positively charged CSPs with the nonaqueous mobile phases of pure ethanol or mixture of hexane-alcohol and the aqueous phases of acetonitrile-water or 95% ethanol. Fast separation of enantiomers was achieved on the newly prepared CSPs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bifunctional reagent of 3-(triethoxysilyl)propyl isocyanate (TEPI) was initially adopted as a spacer reagent to prepare the bonded types of chiral stationary phases (CSPs) with cellulose derivatives. The silica-based CSPs were chemically prepared with non-regioselective and regioselective approaches and their chiral resolving capabilities were evaluated in terms of HPLC resolution of test enantiomers. It was observed that the chiral recognition capabilities of the non-regioselectively prepared CSPs were influenced by the amount of TEPI used. And also, the regioselectively prepared CSP generally showed a slightly higher resolution power than the non-regioselectively prepared CSP, while the non-regioselective procedures were highly advantageous to rapid preparation. In addition, chiral recognition of the prepared CSPs was affected by the properties of the used silica matrices. (C) 2003 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method for preparation of molecularly imprinted monolithic stationary phase has been improved to achieve liquid chromatographic separation of enantiomers and diastereomers. By adopting low polar porogenic solvents of toluene and dodecanol and optimal polymerization conditions, the molecularly imprinted monolithic stationary phases with good flow-through properties and high resolution were prepared. Enantiomers of amino acid derivatives and diastereomers of cinchona alkaloids were completely resolved using the monolithic stationary phases. The influence of porogenic composition, monomer-template ratio and polymerization conditions on the chromatographic performance was investigated. Some chromatographic conditions such as the composition of the mobile phase and the temperature were characterized. Scanning electron microscopy showed that the molecularly imprinted monolithic stationary phase has a large through-pore structure to allow the mobile phase to flow through the column at very low backpressure. Accelerated separations of enantiomers and diastereomers were therefore achieved at elevated flow rates. Finally, the chiral recognition performance of the prepared stationary phase in aqueous media was investigated. Hydrophobic interaction, and ionic and/or hydrogen bonding interactions were proposed to be responsible for the recognition mechanism. (C) 2002 Elsevier Science B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Composite chiral stationary phases (CSPs) were prepared on the basis of cellulose derivatives coated or bonded onto silica. "Molecular exterior" type CSPs were prepared by mixing together two different cellulose tris-derivatives before or after being coated or bonded onto silica, and the "molecular interior" type was obtained by synthesizing non-regioselectively heterosubstituted cellulose derivatives coated or bonded onto silica. For the sake of comparison, the individual phases were also prepared with corresponding cellulose derivatives by coating or bonding approaches, respectively. All of the prepared CSPs were characterized and their chiral recognition properties were evaluated by HPLC with several test racemates. The experimental results demonstrated that the "molecular exterior" CSPs generally exhibit chiral recognition capacities intermediate between those of the two individual phases. However, in the separation of some racemates higher enantioselectivity may be achieved on the "molecular interior" phases than on individual phases, thus broadening the application range of a single cellulose-based CSP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human serum albumin (HSA) was successfully bonded to silica with s-triazine as activator. The coupling reaction by this method was rapid and effective. The triazine-activated silica is relatively stable and can be installed for at least 1 month without obvious loss of reactivity when stored below 30 degreesC, pH below 7. It was observed that the amount of bound HSA reached 120 mg/g silica calculated from the UV absorbance difference of the HSA solution. d,l-tryptophan was selected as the probe solute to characterize the properties of HSA bonded s-triazine chiral stationary phase, and separation factor of 9.4 was obtained for d,l-tryptophan. Furthermore, the amount of effective HSA on silica was measured by high-performance frontal analysis, and only 16.8 mg/g silica was responsible for the resolution of d,l-tryptophan. These results indicate that the amount of both the bound and effective HSA on silica with triazine as activator was much higher than those by the Schiff base coupling method. Different kinds of enantiomers were resolved successfully on the aminopropylsilica-bonded HSA s-triazine chiral stationary phase. (C) 2000 Wiley-Liss, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple preparation process of alkylamide phase for reversed-phase HPLC (RP-HPLC) is described. The process includes aminopropyltrimethoxysilane firstly reacted with octanoyl chloride, then the intermediate was coupled onto porous silica. The resultant bonded silica has a reproducible ligand surface concentration and homogenous bonded ligand distribution on the porous silica. Characterization of prepared packing was carried out with elemental analysis, solid-state C-13 NMR and Fourier transform infrared (FT-IR). Chromatographic evaluations were carried out by using a mixture of organic compounds including acidic, basic and neutral analytes under methanol/water as binary mobile phase. The results showed that the stationary phase have excellent chromatographic properties and can be efficiently used for the separation of basic compounds.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review surveys the recent progress in the adsorbed stationary phases for capillary electrochromatography (CEC). Adsorption-based methods for preparation of stationary phase are novel approaches in CEC, which allow rapid and facile preparing stationary phases with desirable selectivity onto an open-tubular fused-silica capillary, a baresilica or ion-exchange packed column or a monolithic silica or polymer column. A variety of adsorbing agents have been developed as adsorbed stationary phases, including ionic long-chain surfactant, protein, peptide, amino acid, charged cyclodextrin (CD), basic compound, aliphatic ionene, and ion-exchange latex particle. The adsorbed stationary phases have been applied to separation of neutral, basic and acidic organic compounds, inorganic anions and enantiomers. They have also been applied to on-line sample concentration, fast separation and study of the competitive binding of enantiomers with protein.