990 resultados para SEMICONDUCTOR LASERS


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä tutkitaan aktiivihiilielementissä etenevän kaasun adsorptiorintaman mittaamista puolijohdekaasuantureiden avulla. Työn teoriaosuudessa on tutustuttu aktiivihiilen suodattaviin ominaisuuksiin, valmistusprosessiin ja aktiivihiilen raaka-aineen valintaan. Teoreettisen tarkastelun perusteella työssä on laboratorio-olosuhteissa tutkittu lämmitettävien puolijohdekaasuanturien soveltuvuutta hiilessä etenevän adsorptiorintaman havaitsemiseen. Puolijohdekaasuantureille suoritetun herkkyystestauksen perusteella tutkittiin antureiden kykyä tunnistaa aktiivihiileen adsorboituneiden aineiden eteneminen hiilimateriaalissa. Suoritettujen mittausten perusteella todettiin puolijohdeantureiden soveltuvan hyvin aktiivihiilessä etenevän adsorptiorintaman havaitsemiseen. Antureiden selektiivisyydestä johtuen tutkittaessa useamman kaasun muodostaman adsorptiorintaman etenemistä hiilessä on käytettävä useita erityyppisiä puolijohdekaasuantureita.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fiber laser for materials processing have undergone a rapid development in the pastseveral years. As fiber laser provides a combination of high beam quality and awavelength that is easily absorbed by metal surfaces, the named future laser isexpected to challenge the CO2 and Nd:YAG lasers in the area of metal cutting. This thesis studied the performance of fiber laser cutting mild steel. In the literature review part, it introduced the laser cutting principle and the principle of fiber laser including the newest development of fiber laser cuttingtechnology. Because the fiber laser cutting mild steel is a very young technology, a preliminary test was made in order to investigate effect of the cutting parameters on cut quality. Then the formal fiber laser cutting experiment was madeby using 3 mm thickness S355 steel with oxygen as assistant gas. The experimentwas focused on the cut quality with maximum cutting speed and minimum oxygen gas pressure. And the cut quality is mainly decided by the kerf width, perpendicularity tolerance, surface roughness and striation patterns. After analysis the cutting result, several conclusions were made. Although the best result got in the experiment is not perfect as predicted, the whole result of the test can be accepted. Compared with CO2 laser, a higher cutting speed was achieved by fiber laser with very low oxygen gas pressure. A further improvement about the cutting quality might be possible by proper selection of process parameters. And in order to investigate the cutting performance more clearly, a future study about cutting different thickness mild steel and different shape was recommended.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A collaborative study on Raman spectroscopy and microspectrophotometry (MSP) was carried out by members of the ENFSI (European Network of Forensic Science Institutes) European Fibres Group (EFG) on different dyed cotton fabrics. The detection limits of the two methods were tested on two cotton sets with a dye concentration ranging from 0.5 to 0.005% (w/w). This survey shows that it is possible to detect the presence of dye in fibres with concentrations below that detectable by the traditional methods of light microscopy and microspectrophotometry (MSP). The MSP detection limit for the dyes used in this study was found to be a concentration of 0.5% (w/w). At this concentration, the fibres appear colourless with light microscopy. Raman spectroscopy clearly shows a higher potential to detect concentrations of dyes as low as 0.05% for the yellow dye RY145 and 0.005% for the blue dye RB221. This detection limit was found to depend both on the chemical composition of the dye itself and on the analytical conditions, particularly the laser wavelength. Furthermore, analysis of binary mixtures of dyes showed that while the minor dye was detected at 1.5% (w/w) (30% of the total dye concentration) using microspectrophotometry, it was detected at a level as low as 0.05% (w/w) (10% of the total dye concentration) using Raman spectroscopy. This work also highlights the importance of a flexible Raman instrument equipped with several lasers at different wavelengths for the analysis of dyed fibres. The operator and the set up of the analytical conditions are also of prime importance in order to obtain high quality spectra. Changing the laser wavelength is important to detect different dyes in a mixture.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Position sensitive particle detectors are needed in high energy physics research. This thesis describes the development of fabrication processes and characterization techniques of silicon microstrip detectors used in the work for searching elementary particles in the European center for nuclear research, CERN. The detectors give an electrical signal along the particles trajectory after a collision in the particle accelerator. The trajectories give information about the nature of the particle in the struggle to reveal the structure of the matter and the universe. Detectors made of semiconductors have a better position resolution than conventional wire chamber detectors. Silicon semiconductor is overwhelmingly used as a detector material because of its cheapness and standard usage in integrated circuit industry. After a short spread sheet analysis of the basic building block of radiation detectors, the pn junction, the operation of a silicon radiation detector is discussed in general. The microstrip detector is then introduced and the detailed structure of a double-sided ac-coupled strip detector revealed. The fabrication aspects of strip detectors are discussedstarting from the process development and general principles ending up to the description of the double-sided ac-coupled strip detector process. Recombination and generation lifetime measurements in radiation detectors are discussed shortly. The results of electrical tests, ie. measuring the leakage currents and bias resistors, are displayed. The beam test setups and the results, the signal to noise ratio and the position accuracy, are then described. It was found out in earlier research that a heavy irradiation changes the properties of radiation detectors dramatically. A scanning electron microscope method was developed to measure the electric potential and field inside irradiated detectorsto see how a high radiation fluence changes them. The method and the most important results are discussed shortly.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The pre-conditioning of tumor vessels by low-dose photodynamic therapy (L-PDT) was shown to enhance the distribution of chemotherapy in different tumor types. However, how light dose affects drug distribution and tumor response is unknown. Here we determined the effect of L-PDT fluence on vascular transport in human mesothelioma xenografts. The best L-PDT conditions regarding drug transport were then combined with Lipoplatin(®) to determine tumor response. in vivo. Lasers Surg. Med. 47:323-330, 2015. © 2015 Wiley Periodicals, Inc. METHODS: Nude mice bearing dorsal skinfold chambers were implanted with H-Meso1 cells. Tumors were treated by Visudyne(®) -mediated photodynamic therapy with 100 mW/cm(2) fluence rate and a variable fluence (5, 10, 30, and 50 J/cm(2) ). FITC-Dextran (FITC-D) distribution was assessed in real time in tumor and normal tissues. Tumor response was then determined with best L-PDT conditions combined to Lipoplatin(®) and compared to controls in luciferase expressing H-Meso1 tumors by size and whole body bioluminescence assessment (n = 7/group). RESULTS: Tumor uptake of FITC-D following L-PDT was significantly enhanced by 10-fold in the 10 J/cm(2) but not in the 5, 30, and 50 J/cm(2) groups compared to controls. Normal surrounding tissue uptake of FITC-D following L-PDT was significantly enhanced in the 30 J/cm(2) and 50 J/cm(2) groups compared to controls. Altogether, the FITC-D tumor to normal tissue ratio was significantly higher in the 10 J/cm(2) group compared others. Tumor growth was significantly delayed in animals treated by 10 J/cm2-L-PDT combined to Lipoplatin(®) compared to controls. CONCLUSIONS: Fluence of L-PDT is critical for the optimal distribution and effect of subsequently administered chemotherapy. These findings have an importance for the clinical translation of the vascular L-PDT concept in the clinics. Lasers Surg. Med. 47:323-330, 2015.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El láser de Nd:YAG está compuesto por un granate de itrio y aluminio, contaminado por neodimio. Emite a una longitud de onda de 1064 nm, en el infrarrojo cercano. A diferencia de otros láseres, el láser de Nd:YAG, puede transmitirse a través de fibra óptica, lo cual permite una fácil aplicación de este tipo de energía en espacios anatómicos bucodentarios de difícil acceso. Este hecho, asociado al potente efecto bactericida que produce esta longitud de onda, lo convierten en una herramienta ideal en los tratamientos endodóncicos y periodontales, en los que puede mejorar los resultados obtenidos con las técnicas convencionales. También se utiliza en ciertos tratamientos de Cirugía Bucal, principalmente para las exéresis de lesiones de tejidos blandos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We have studied the current transport and electroluminescence properties of metal oxide semiconductor MOS devices in which the oxide layer, which is codoped with silicon nanoclusters and erbium ions, is made by magnetron sputtering. Electrical measurements have allowed us to identify a Poole-Frenkel conduction mechanism. We observe an important contribution of the Si nanoclusters to the conduction in silicon oxide films, and no evidence of Fowler-Nordheim tunneling. The results suggest that the electroluminescence of the erbium ions in these layers is generated by energy transfer from the Si nanoparticles. Finally, we report an electroluminescence power efficiency above 10−3%. © 2009 American Institute of Physics. doi:10.1063/1.3213386

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Lasertarkkuusporauksella on tämän hetken teollisuudessa useita sovelluksia, kuten esimerkiksi mustesuihkukirjoittimet, dieselmoottoreiden polttoainesuuttimet, lääketieteen instrumentit, turbiinien lapojen jäähdytysreiät ja stensiilit. Tässä työssä on tutkittu laserporauksen mahdollisuuksia 99,9 % kupariin sekä EN 1.4301 ruostumattomaan teräkseen (vastaava AISI 304). Ainepaksuuksia oli käytettävissä kolmea: 0,1 mm, 0,5 mm ja 1,0 mm. Vertailun vuoksi valittiin tutkimukseen mukaan ainepaksuudeltaan 1,0 mm EN 1.4432 haponkestävää terästä (vastaava AISI 316L). Tutkimuksessa käytettiin kolmea eritehoista 1,064 µm aallonpituuden Nd:YAG – laseria ja yhtä CO2 – laseria. Poratut reiät kuvattiin elektronimikroskoopilla ja jokaisesta reiästä mitattiin halkaisija, ympyrämäisyys ja kartiokkuus. Lisäksi reiän laatua arvioitaessa tarkasteltiin purseen määrää reikien ympärillä. Tutkimus osoitti, että eri materiaaleihin voidaan porata, laserin säteen laadusta ja aallonpituudesta riippuen, hyvin erikokoisia reikiä. Kartiokkuuteen havaittiin voitavan vaikuttaa polttopisteen paikkaa siirtämällä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityö on tehty kuitumateriaalien laserleikkauksen tutkimusprojektissa ILAC/PAPER. Päätavoitteena on selvittää laserleikkauksen kustannukset ja arvioida kahden laserleikkaussovelluksen taloudellista kannattavuutta. Teoriaosassa tavoitteena on etsiä teknologiainvestoinneista piirteitä, jotka tulee ottaa huomioon hanketta suunnitellessa. Työssä esitellään myös menetelmä teknologiainvestointien arviointiin. Työssä on kolme aihepiiriä; teknologiainvestointien arviointi, laserleikkauksen perusteet ja kuitumateriaalien laserleikkauskustannuksia käsittelevä empiriaosa. Teoriaosan lähdemateriaalina on käytetty toimintolaskentaa ja teknologiainvestointeja käsiteleviä julkaisuja. Empiriaosa on koottu teollisuuden tiedonannoista, tutkimusmateriaalista ja myyntitarjouksista. Teknologiainvestointien perusteleminen on vaikeaa perinteisillä investointilaskennan menetelmillä vähäisistä suorista kustannussäästöistä johtuen. Sopiva menetelmä arvioikin hankkeet laajempina kokonaisuuksina. Laserlaitteistojen vuosittaiset kustannukset ovat suuret. Luotettavuus, huoltovapaus ja joustavuus ovat hyötyjä, jotka tekevät laserlaitteistosta kannattavan. Hankintahinta ja tuottavuus ratkaisevat investoinnin kannattavuuden.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ADSL (Asymmetrical Digital Subsciber Line) on puhelinkaapelia siirtotienä käyttävä nopea Internet-liityntäteknologia, joka on yleistynyt viime vuosina kuluttajamarkkinoilla. Analoginen puhelinverkko on alun perin tarkoitettu puheen siirtoon 0-4kHz:n äänitaajuuskanavalla, mikä aiheuttaa rajoitteita datasiirtoon ylemmillä taajuuksilla. Puhelinverkkojen rakenne vaihtelee alueittain sisältäen erilaisia datasiirtoa häiritseviä tekijöitä. Tämän vuoksi ADSL-päätelaitteilta vaaditaan sopeutumiskykyä vaativiinkin olosuhteisiin. Nykyiset ADSL-standardit eivät vaadi päätelaitteilta riittävää suorituskykyä, jotta luotettava tiedonsiirto onnistuisi myös huonoissa verkko-olosuhteissa. Epäkohdan korjaamiseksi DSL Forum on kehittänyt yhdessä laitevalmistajien, tietoliikenneoperaattoreiden ja komponenttivalmistajien kanssa ADSL-päätelaitteiden yhteensopivuustestaukseen testipaketin nimeltä TR-048. Se on kattava joukko tarkkaan kuvattuja testejä, joissa keskitytään enimmäkseen fyysisen kerroksen testaamiseen. TR-048:aa ei vaadita vielä nykyisissä ADSL-standardeissa, mutta yksityiset laboratoriot ja laitetoimittajat ovat vähitellen ottamassa sitä käyttöön. Tämän työn keskeisenä tavoittena oli tehdä sovellus, jolla automatisoitiin suurin osa TR-048:n sisältämien ADSL-linjan fyysisen kerroksen testeistä. Valmiilla sovelluksella ajetun testikierroksen perusteella arvioitiin sovelluksesta saatua hyötyä ja tuotekehitysvaiheessa olevan Nokia D500 tilaajasolmun suorituskykyä. Työn teoriaosassa esitellään ADSL-teknologiaa ja ADSL-lähetin-vastaanottimen loogista toimintaa.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityössä tutkitaan diodilaserhitsausta mahdollisena teollisuuden menetelmänä ja menetelmän vaatimuksia hitsattaessa ohutlevyjä. Työssä tutkittavat materiaalit ovat kylmävalssattu teräs ja ruostumaton teräs sekä liitosmuotoina päittäis-, laippa- ja päällekkäisliitos. Materiaalivahvuudet ovat 0,50 mm:stä 1,50 mm:iin. Työn tavoitteena on määrittää näille kyseisille materiaaleille ja liitosmuodoille hitsausnopeus levynvahvuuden funktiona. Lisäksi käsitellään diodilaserin rakennetta, säteen muodostusta, säteen muokkaamista, säteen analysointia ja säteen turvallisuuteen liittyviä asioita. Suoritetaan vertailua käytössä oleviin muihin lasertyöstömenetelmiin konepajoissa ja tehdään arvio mahdollisen diodilaserinvestoinnin kannattavuudesta. Diodilaserhitsauskokeissa käytettiin Hämeen ammattikorkeakoulun Riihimäen yksikön 1 kW:n tehoista diodilaseria. Koekappaleet leikattiin suuntaisleikkurilla. Osalle hitsatuista kappaleista tehtiin poikittaiset vetokokeet ja mitattiin mikrokovuudet. Virheitä tutkittiin silmämääräisesti sekä radiografisella kuvauksella. Kaikille tutkituille liitoksille, materiaaleille ja vahvuuksille saatiin määriteltyä hitsausnopeudet. Tehtyjen testien perusteella suuntaisleikkurin käyttö on mahdollista. Lisäksi havaittiin suojakaasun käytön myötä, että kirkkaan sulan aiheuttama heijastavuuden kasvu edellyttää hitsausnopeuden pienentämistä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

By exciting at 788 nm, we have characterized the near infrared emissions of trivalent thulium ions in monoclinic KGd(WO4)2 single crystals at 1.48 and 1.84 mm as a function of dopant concentration from 0.1% to 10% and temperature from 10 K to room temperature. We used the reciprocity method to calculate the maximum emission cross-section of 3.0310220 cm2 at 1.838 mm for the polarization parallel to the Nm principal optical direction. These results agrees well with the experimental data. Experimental decay times of the 3H4!3F4 and 3F4!3H6 transitions have been measured as a function of thulium concentration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In order to improve the efficacy and safety of treatments, drug dosage needs to be adjusted to the actual needs of each patient in a truly personalized medicine approach. Key for widespread dosage adjustment is the availability of point-of-care devices able to measure plasma drug concentration in a simple, automated, and cost-effective fashion. In the present work, we introduce and test a portable, palm-sized transmission-localized surface plasmon resonance (T-LSPR) setup, comprised of off-the-shelf components and coupled with DNA-based aptamers specific to the antibiotic tobramycin (467 Da). The core of the T-LSPR setup are aptamer-functionalized gold nanoislands (NIs) deposited on a glass slide covered with fluorine-doped tin oxide (FTO), which acts as a biosensor. The gold NIs exhibit localized plasmon resonance in the visible range matching the sensitivity of the complementary metal oxide semiconductor (CMOS) image sensor employed as a light detector. The combination of gold NIs on the FTO substrate, causing NIs size and pattern irregularity, might reduce the overall sensitivity but confers extremely high stability in high-ionic solutions, allowing it to withstand numerous regeneration cycles without sensing losses. With this rather simple T-LSPR setup, we show real-time label-free detection of tobramycin in buffer, measuring concentrations down to 0.5 μM. We determined an affinity constant of the aptamer-tobramycin pair consistent with the value obtained using a commercial propagating-wave based SPR. Moreover, our label-free system can detect tobramycin in filtered undiluted blood serum, measuring concentrations down to 10 μM with a theoretical detection limit of 3.4 μM. While the association signal of tobramycin onto the aptamer is masked by the serum injection, the quantification of the captured tobramycin is possible during the dissociation phase and leads to a linear calibration curve for the concentrations over the tested range (10-80 μM). The plasmon shift following surface binding is calculated in terms of both plasmon peak location and hue, with the latter allowing faster data elaboration and real-time display of the results. The presented T-LSPR system shows for the first time label-free direct detection and quantification of a small molecule in the complex matrix of filtered undiluted blood serum. Its uncomplicated construction and compact size, together with the remarkable performances, represent a leap forward toward effective point-of-care devices for therapeutic drug concentration monitoring.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Els làsers aporten solucions a una gran varietat de problemes de la vida diària ...