974 resultados para Resina macia


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Recent bonding systems have been advocated as multi-purpose bonding agents. The aim of this study was to determine if some of these bonding systems could be associated to composite resins from different manufacturers. This investigation was conducted to test lhe shear bond strength of three bonding systems: Scotchbond Multi-Purpose (3M Dental Products), Optibond Light Cure (Kerr) and Optibond Dual Cure (Kerr), when each of them was associated to lhe composite resins: Z1 00 (3M Dental Products), Prisma - APH (Dentsply) and Herculite XRV (Kerr). Seventy-two flat dentin bonding sites were prepared to 600 grit on human premolars mounted using acrilic resins. The teeth were assigned at random to 9 groups of 8 samples each. A split die with a 3mm diameter was placed over lhe surface of lhe dentin treated with one of lhe adhesive systems, and lhe selected composite resin was inserted and light cured. The split mold was removed and all samples were termocycled and stored in 37ºC water for 24 hours before testing. Shear bond strength was determined using an lnstron Universal testing machine. Some failures were examined under lhe S.E.M. Data was analysed by one-way analysis of variance, that demonstrated a significant difference (p<0,05) in the mean shear bond strength among Optibond Light Cure (15,446 MPa), Scotchbond Multi-Purpose (13,339 MPa) and Optibond Dual Cure (10,019 MPa). These values did not depend on the composite resin used. The association between bonding system/composite resin was statistycally significant (p<0,05) and the best results were obtained when the composite resins Z100 and Herculite were used with the adhesive system Optibond Light Cure, and when the composite resin APH was used with the adhesive system Scotchbond Multi-Purpose

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect in the gingival tissue of four distinctive types of relationships between the major conector and the gingival margin was investigated in eight subjects in association with the experimental gingivitis model. The subjects wore appliances constructed in acrylic resin (retained by means of embrasure hooks) throughout the day an night, except during meals. After the appliances had been placed, the subjects were abstained from any oral hygiene for twenty-one days. Records of the Plaque Index, Gingival Index and probing deplh were taken at baseline and at each week. Data showed that there was a small increase in the Plaque Index and Gingival Index for the four areas and that the degree of inflammation of the covered areas was higher in the area without relief

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Odontologia Restauradora - ICT

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the apical sealing ability and the marginal adaptation of five dental materials used in retrofillings or applied to the bevelled root surface. One hundred and forty extracted single rooted human teeth were used, divided into seven groups of twenty each. ln the first, second, third and fourth groups, the teeth were apicoectomized, submitted to cavity preparations and retrofilled with one of the following materiais: zinc free silver amalgam, a dentin bonding system plus composite resin, a glass ionomer cement ora compomer. In the fifth, sixth and seventh groups, the teeth were apicoectomized and capped on the bevelled root surface with one of the following materiais: a dentin bonding system plus composite resin, a glass ionomer cement or a compomer. Two specimens of each experimental group were evaluated for the marginal adaptation using scanning electron microscopy. The remaining 126 specimens were immersed in 2% methylene blue dye, stored for one week at 37ºC and the infiltration was evaluated with a stereomicroscope. The results showed that the glass ionomer cement presented the lowest values of marginal infiltration when used as retrofilling material, with a significant statistical difference when compared with the others tested materials. When used as apical capping, the glass ionomer cement and the compomer were equivalent and significantly better than the dentin bonding system plus composite resin. Using scanning electron microscopy, all the materials showed some slight adjustment problem. ln the retrofilling, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin, while the largest were observed with the glass ionomer cement and zinc free silver amalgam. ln the apical capping, the smallest marginal gaps were observed with the compomer and the dentin bonding system plus composite resin and ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The disadvantages generated by the acid etching of the dentin, such as an increase in its permeability, in the surface moisture and in the potential to denature the external dentinal collagen, the formation of a fragility zone and the citotoxicity of the adhesive monomers; which are all aggravated by the depth of the dentin, have stimulated new and different treatment philosophies of the dentin. The purpose of the present study, therefore, was to investigate the effects of three dentin treatments: laser irradiation, acid etching and hypermineralization, in the shear bond strength of the SMP Plus bonding system. Sixty bovine incisors were extracted and randomly selected immediatly alter the animal's death. They were kept frozen (-18°C) for no longer than 14 days. After buccal dentinal surface had been exposed, X-Rays were taken to control the dentin thickness. The specimens were separated into two groups: (1) Control, kept in distilled water at 4ºC; (2) Mineralized, kept in hypermineralized solution at 4°C for 14 days. Each group was divided into three sub-groups according to the type of dentin treatment used: group F - followed the manufacturer instructions (acid-etching + primer + bond), group AL (acid-etching + primer + bond + laser) and group LA (laser + (laser + acid-etching + primer + bond). A composite resin standard cylinder (Z100-3M) was bond to the dentinal surface and the shear bond strength performed on a Universal lnstron machine 4301, with 500 Kg load and at 0,5mm/min. speed. The analysis of variance (ANOVA) determined that the treatments influenced the shear bond strength values (p<0,05) with the following average shearing load at failure: AL (9,96 MPa), F (7,28MPa) e LA (4,87 MPa). The interaction between the two factors analyzed Group (control and mineralized) and treatment (F, AL, LA) also influenced the shear bond strength (p<0,05). The highest values were obtained...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To evaluate the volumetric changes due to polymerization and thermocycling on different resin-composites. Methods: Thirteen A2 Universal Dentin shade resin-composites (n = 10) from eight manufacturers were evaluated (4Seasons, Grandio, Venus, Amelogen Plus, P90, Z350, Esthet-X, Amaris, Vita-l-escence, Natural-Look, Charisma, Z250 and Opallis). The polymerization shrinkage percentage (PS) was calculated using an image measurement device (ACUVOL - Bisco Dental). Equal volumes of material, standardized by a semisphere polyurethane matrix (d = 3mm) were used and, after 5 minutes of relaxation, the baseline volume measurements were obtained with 18 J of energy dose from the LED light-curing unit. Measurements were obtained after 5 minutes and PS values calculated. Specimens were stored in a drydark environment for 24 hours and re-measured. Specimens were then thermocycled in distilled water between 5oC and 55oC for 20,000 cycles, subjected to another volume measurement at 5,000 cycle intervals. Specimens were gently dried prior to each measurement. Results: Repeated measurements were made using ANOVA (α = 0.05) showed that all resin-composite volumes were influenced by the number of cycles. Volumes at 5 minutes post-polymerization (12.47 ± 0.08) were significantly lower than those at baseline (12.80 ± 0.09). Volumes at 24 hours (12.43 ± 0.19) were insignificantly lower than those at 5 minutes postpolymerization. With regards to the impact of thermocycling, all specimens showed statistically significant increases in volume after 5,000 cycles (13.04 ± 0.22). Although statistically different from those after 5,000 cycles, there was no statistically significant difference between volumes measured at 10,000 (12.87±0.21), 15,000 (12.92±0.24), and 20,000 (12.84±0.23) cycles. Conclusion: According to the video-imaging analysis, thermocycling caused a significant expansion in resin-composites tested, the volume increase was not able to...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Persistent Organic Pollutants (POPs) are chemical substances extraordinarily toxic and persistent in the environment. Due to these properties, POPs are targets of the Stockholm Convention which aims to provide means to eliminate production and use by encouraging the reduction and, where possible, eliminating the release of these contaminants to the environment. One of the articles of this _Convention aims to assess the basal levels of such substances in the environment to monitor both the reduction of release to the environment, and to assess human exposure, using analyzes of milk and air for example. Although efforts to control POPs production and release to the environment have been made, data about their levels in Brazil are still scarce, mainly in the atmosphere or indoor environment. Considering the permanence of people inside its house, this study presents a method for POP extraction from XAD-2 sorbent employed in indoor air sampling, with identification and quantification by GC-ECD. GC-ECD linear range of the studied analytes, congeners of polychlorinated biphenyls (PCB) (28, 52, 101, 118, 138, 153 and 180), DDTs and their metabolites (DDDs, DDEs) and endosullan (isomers c - and 13 - and metabolite endosulfan sulfate) ranged between 0.5 and 16.0 ng mL-I with r2 > 0.967. The method developing consist of selecting the extraction solvent system by agitation (90 rpm, 1 hour) with n-hexan,e (2 mL) or n-hexane:acetone (1:1, v/v) (2 mL), concentration the extract with a gentle N2 stream, and evaluation of breakthrough with passage or air through the fortified XAD-2 cartridge before extraction, employing a low volume air suction pump (Pump Model 224 universal-PCXR8; 5-5000 mL min-1, SKC Inc., Eighty Four, PA, USA), Calibrator Dry-Cal DC-Lite (BIOS, Butler, NJ, USA)). Two fortification levels were employed, 15 and 30 ng. After selecting n-hexane as extraction solvent, with accuracy and precision ranging...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Para produzir o termopotássio e, até mesmo, o KCl, a rocha silicática potássica (verdete) passa pelo processo de calcinação. Neste processo é gerado um resíduo denominado coproduto que contém em sua composição química 3% a 4% de K2O, Ca, Mg e Si e apresenta baixa solubilidade em água. O presente trabalho objetivou testar a hipótese de que doses de K2O na forma de coproduto fornecem potássio para as plantas de milho em menor quantidade do que as mesmas doses na forma de KCl, inclusive no estudo do efeito residual, e que o potássio extraído do solo pela resina trocadora de íons tem maior correlação com as quantidades de potássio absorvida pela planta de milho do que com o potássio extraído pela solução extratora de Mehlich-1. O experimento foi conduzido em casa de vegetação, onde foram realizados dois cultivos consecutivos de milho em amostras de Neossolo Quartizarênico órtico. O delineamento foi em blocos casualizados com duas fontes de K (KCl e coproduto), três doses de K2O (0, 200 e 400 kg ha-1) e quatro repetições, totalizando 24 unidades experimentais. Foram determinados os teores de potássio extraído da amostra de solo pela solução extratora de Mehlich-1 e resina trocadora de íons, a produção de matéria seca da parte aérea das plantas de milho, os teores e o acumulo de potássio nas plantas após o primeiro e o segundo cultivo. Em dois cultivos consecutivos das plantas de milho, a aplicação de 200 e 400 kg ha-1 de K2O na forma de KCl proporcionou o acumulo de potássio na parte aérea das plantas de 77 e 84% maior do que aplicação dessas mesmas doses de K2O na forma de coproduto, respectivamente. A aplicação de 200 e 400 kg ha-1 de K2O na forma de coproduto proporcionou aumentos no acumulo de potássio da parte aérea das plantas de milho de 66 e 75% em relação ao controle (sem K2O), respectivamente. A recuperação de potássio pelas plantas de milho tratadas com KCl foi de 92% e as plantas...