993 resultados para Reproducibility


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Pesquisa e Desenvolvimento (Biotecnologia Médica) - FMB

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência e Tecnologia de Materiais - FC

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This experimental study aimed the evaluation of the use of anthropomorphic phantoms in the analysis of the influence of the acquisition parameters in the contrast of radiographic images. The analyzed factors were the variation of the peak kilovoltage (kVp) and the product of the filament circuit by the time of exposition (mAs). The influence of these factors was verified for different anthropomorphic phantoms: foot, knee and chest. The image contrast behavior with the simulators was compared to values obtained with the use of an aluminum ladder being the behavior of this reference for analysis and discussion. To assure the reproducibility of images, quality control tests were made and evaluation of procedure conditions before the experiments. The results obtained are shown in a scale of images where it was possible to evaluate the impact in the darkness of images. Regions with different compositions were analyzed which were different in image, this way the values of optical density and contrast are represented as charts and graphics. We conclude that the use of anthropomorphic phantoms in the evaluation of the influence of tension of the tube and time of exposition in the contrast of the radiographic images is not indicated for a quantitative analysis through optical density, once they present incompatible results with the data as reference as the aluminum ladder even so these simulators present a great property in qualitative analysis regarding the differentiation of structures and subjective evaluations

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Measurement System Analysis (MSA - Measurement System Analysis) is a statistical methodology developed to study and analyze the behavior of the measurement systems, and, therefore, allow the increased of the confidence readings performed by measuring instruments. It’s widely used in the automotive industry since the 90’s and is a mandatory requirement for the approval of the parts according to ISO Standard of the automotive sector. However, the aerospace industry doesn’t require this type of Study, once which the vast majority of aeronautics parts have characteristics (dimensions) with very tight tolerances, closed, ie, at the home of microns. This work aims to create lists of recommendations for definitions of measuring instruments in developing of control plans, which correlates tolerances fields of characteristics for different settings and acceptance of the instrument, classified as optimum, recommended and not recommended, through of the study of R&R (Repeatability and Reproducibility) in aeronautics parts. Every methodology of the experimental part was based on modern strategy of continuous improvement, the DMAIC (Define Measure Analyze Implant Control), in order to achieve better measurement method used in the control of milling aeronautics parts, identifying and reducing the variations of the measurement process. The results of the R&R Study in large part of measuring instrument manuals were considered acceptable and/or recommended, ie with values of %P/T and %RR lower than 30%, providing statistical data which have enabled the elaboration of tables of recommendations, which, from this work, have turned into very important documents and aid for Process Engineering, having in their hands a technical study able to identify which is the most appropriate instrument to get a more robust dimensional... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Technology is growing interest in the use of composites, due to the requirement of lighter materials and more resistant, factors essential to meet the project specifications and reduce the operational cost. In the production of high performance structural composites, considering the aerospace criteria, the domestic industry has shown interest in the process of resin transfer molding (RTM) for reproducibility and low cost. This process is suitable for producing components of polymeric composites with relatively simple geometries, consistent thicknesses, high quality finish with no size limitations. The objective of this work was machined carbon steel to make a matched-die tooling for RTM and produce two composite plates of epoxy resin and carbon fiber fabric with and without induced discontinuities, which were compared towards their impregnation with ultrasound, their properties via tensile tests and thermal analysis. In ultrasonic inspection, it was found good impregnation of the preform of both composites. In the thermal analysis it was possible to check the degradation temperature of the composites, the glass transition temperature and it was found that the composites showed no effective cure cycles, but presented good performance in the tensile test when compared with aluminum alloy 7050 T7451 . The results showed that the injection strategy was appropriate since the laminate exhibited a good quality for the proposed application

Relevância:

10.00% 10.00%

Publicador:

Resumo:

After confirming the high specific mechanical properties of composite materials by scientific studies conducted over the last decades, one of the challenges of this new class of materials is the ability to achieve mass production at a more affordable cost, which has become indispensable. The Resin Transfer Molding (RTM) is an excellent method for manufacturing composite materials. Despite being a process widely used by international companies in the production of high performance structural composites, only a short time the national aviation industry has shown interest in implementing this type of processing to more complex structures and greater structural responsibility. In aeronautical projects, the reproducibility and the relative low cost of this process, several studies have been performed in Brazil for learning and perfecting this technique. This process is suitable for producing polymer components both simple as complex geometry, and allows to achieve consistent thickness, with high quality finish and without limiting range. Polymeric composite components for the high mechanical stress applications such as aircraft structures, satellites, etc., require a strict control of volume fractions of the composite constituents, beyond the knowledge of their mechanical and thermal properties. Therefore, in this experimental work degree study on the mechanical, thermal and of porosity composites processed by RTM processed characterization was performed. This characterization was performed targeting a possible aerospace application of this composite material. For the production of composites, process equipment (RTM RTM injector Radius 2100cc) was used. The processed carbono/epoxy composites were characterized via flexure tests mechanically and thermally analysis via DMA, DSC and TGA. To determine the volume fraction of fibers, the composite samples were analyzed via matrix digestion (ASTM D3171) ... (Complete abstract click electronic access below)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Delivering to the customers a product or service with the expected quality associated to the huge competitiveness that exists in the market nowadays, has been making organizations increasingly focus on quality planning using techniques which are directed towards the continuous improvement process and production optimization. Thus, this paper aims to improve a machining process using the techniques of experimental design to the optimization and this also includes the analysis of the measurement system. For this purpose, the alloy Nimonic 80A, a nickel base superalloy, was used in the process due to its widespread use for high temperatures, applying this study the robust method proposed by Genichi Taguchi, determining the influence of the factors considered input variables, cutting speed, feed rate, depth of cut, type of tool, lubrication, and material hardness, in the output or response variable, surface roughness, concluding with the use of Taguchi orthogonal array L16 and by analysis of ANOVA that the factor feed rate is significant and offers greater effect on the response variable studied, should be set to 0,12mm/rev. Moreover, the factor type of tool has more influence on the process when compared to other factors, being CP250 the one more suitable to the process. Lastly, the interaction feed rate x cutting speed provides greater significance in the process regarding to surface roughness variable, being the best match between them 0,12mm/rev to the feed rate and 90m/min to the cutting speed. In order to evaluate the measurement system, it was applied the repeatability and reproducibility method (R&R), through which we saw that the system needs improvement (R & R = 88.04% >>> 30%) as the value found in the study was well above compared to the one that classifies the system as inappropriate

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Along with the advance of technology, in terms of the expansion of medical exams that uses the ionizing radiation for diagnosis, there is also the concern about quality control for maintaining quality in radiographic imaging and for delivering low dose to the patient. Based on the Federal Order 453 of the Secretariat of Health Surveillance, which takes account of the practical and justification of individual medical exposures, the optimization of radiological protection, limitation of individual dose, and the prevention of accidents, were done through this paper radiodiagnostic tests on medical equipment in order to accept it or not, according to SVS-453. Along with the help and support of P&R Consulting and Medical Physics Marilia, SP, were made Quality Control and Radiometric Control in equipment from various cities across the state of São Paulo. The equipment discussed in this work is classified as conventional X-ray. According to the Federal Order SVS-453, the quality control in the program of quality assurance should include the following minimum set of constancy tests, with following minimum frequency: biennial tests for representative values of dose given to the patients of radiography and CT performed in the service; annual tests for accuracy of the indicator tube voltage (kVp), accuracy of exposure time, half-value layer, aligning the central axis of the beam of x-ray tube, performance (mGy / mA.min.m²), linearity of the rate of kerma on air with the mAs, reproducibility of the kerma on air rates, reproducibility of the automatic exposure, focal spot size, integrity of accessories and clothing for individual protection; semiannually for collimation system accuracy; weekly for temperature processing system and sensitometry processing system. For the room Radiometric Survey it was done a sketch...(Complete abstract click electronic access below)