1000 resultados para Radiação solar : Medição
Resumo:
We present a sample of three large near-relativistic (>50 keV) electron events observed in 2001 by both the ACE and the Ulysses spacecraft, when Ulysses was at high-northern latitudes (>60◦) and close to 2 AU. Despite the large latitudinal distance between the two spacecraft, electrons injected near the Sun reached both heliospheric locations. All three events were associated with large solar flares, strong decametric type II radio bursts and accompanied by wide (>212◦) and fast (>1400 km s−1) coronal mass ejections (CMEs). We use advanced interplanetary transport simulations and make use of the directional intensities observed in situ by the spacecraft to infer the electron injection profile close to the Sun and the interplanetary transport conditions at both low and high latitudes. For the three selected events, we find similar interplanetary transport conditions at different heliolatitudes for a given event, with values of the mean free path ranging from 0.04 AU to 0.27 AU. We find differences in the injection profiles inferred for each spacecraft. We investigate the role that sector boundaries of the heliospheric current sheet (HCS) have on determining the characteristics of the electron injection profiles. Extended injection profiles, associated with coronal shocks, are found if the magnetic footpoints of the spacecraft lay in the same magnetic sector as the associated flare, while intermittent sparse injection episodes appear when the spacecraft footpoints are in the opposite sector or a wrap in the HCS bounded the CME structure.
Resumo:
Se ha estudiado la lixiviación de concentrados de cobre con alto contenido de arsénico (hasta 2,5 %), mediante un proceso de oxidación con cloro formado 'in situ', por la reacción entre hipoclorito de sodio y ácido sulfúrico. El objetivo de estas experiencias es producir una solución de lixiviación, de características adecuadas para entrar a la etapa posterior de extracción por solventes (SX), es decir, entre 4 a 6 g/1 de cobre y 5 a 7 g/1 de ácido residual. Esta disolución, además, deberá contener cantidades mínimas de arsénico y cloruro. Las lixiviaciones se realizaron por agitación en un reactor de acrílico diseñado para tal efecto, a temperatura ambiente y a presión atmosférica. Se utilizaron concentrados de cobre de explotaciones mineras de Antofagasta (Chile). Se estudiaron algunas variables típicas de la lixiviación, como son: la concentración de agente lixiviante, el tiempo de lixiviación, el porcentaje de sólidos y la temperatura. La caracterización de algunos residuos sólidos, producto de las lixiviaciones, se realizó por DRX (Difracción de Rayos X) y EDS (Barrido de Energía Dispersiva de Rayos X). El cobre y arsénico en las disoluciones se analizaron mediante Espectroscopia de Absorción Atómica. Los resultados experimentales indican que es posible obtener soluciones de las características deseadas con este procedimiento, que utiliza reactivos comunes y de relativo bajo costo.
Resumo:
Amorphous silicon n-i-p solar cells have been fabricated entirely by Hot-Wire Chemical Vapour Deposition (HW-CVD) at low process temperature < 150 °C. A textured-Ag/ZnO back reflector deposited on Corning 1737F by rf magnetron sputtering was used as the substrate. Doped layers with very good conductivity and a very less defective intrinsic a-Si:H layer were used for the cell fabrication. A double n-layer (μc-Si:H/a-Si:H) and μc-Si:H p-layer were used for the cell. In this paper, we report the characterization of these layers and the integration of these layers in a solar cell fabricated at low temperature. An initial efficiency of 4.62% has been achieved for the n-i-p cell deposited at temperatures below 150 °C over glass/Ag/ZnO textured back reflector.
Resumo:
La especialidad de la Genética forense tiene algo más de un siglo, pero con la incorporación de la denominada prueba del ADN hace casi tres décadas, se ha logrado una eficacia que ha revolucionado no solo la investigación policial y las sentencias jurídicas, si no que ha impactado positivamente a toda la sociedad moderna. En este trabajo se analiza el avance que han supuesto las técnicas de identificación a través del ADN, en situaciones legales que en su momento no fueron resueltas (casos abiertos), en las exoneraciones y en los estudios familiares. Las aplicaciones y consecuencias de la Genética forense molecular o del ADN en estos casos, no solo ha dotado de más prestigio y seguridad a la Administración de la Justicia, si no que ha tenido un notable impacto social y ético. Es nuestra convicción, que tanto los profesionales de la Administración de la Justicia, como la sociedad en su totalidad debemos congratularnos y contribuir de la mejor manera posible a que las herramientas forenses en general y las vinculadas a la genética avanzada, se implementen al máximo nivel lo antes y mejor posible en nuestras instituciones.
Resumo:
OBJETIVO: Avaliar a precisão das doses de radiação absorvidas na terapia de transplantes de medula óssea durante a técnica de irradiação de corpo inteiro. MATERIAIS E MÉTODOS: Utilizaram-se 200 pastilhas de sulfato de cálcio com disprósio compactado com teflon (CaSO4 + teflon), calibradas no ar e no "phantom", selecionadas aleatoriamente e dispostas em grupos de cinco no corpo dos pacientes. As leituras dosimétricas foram efetuadas pela leitora Harshaw 4000A. Nove pacientes foram irradiados no corpo inteiro em paralelos e em opostos laterais, utilizando-se unidade de cobalto-60, modelo Alcion II, com taxa de dose de 0,80 Gy/min a 80,5 cm, {campo (10 × 10) cm²}. A dosimetria dessa unidade foi realizada com dosímetro Victoreen 500. Para a determinação da dose média em cada ponto avaliado usaram-se os fatores individuais de calibração das pastilhas no ar e no "phantom", colocando-se um "build up" de 2 mm para superficializar a dose à distância de 300 cm. RESULTADOS: Em 70% dos pacientes obteve-se variação de dose menor que 5% e em 30% dos pacientes essa variação foi inferior a 10%, quando comparados os valores medidos com aqueles calculados em cada ponto. Na cabeça ocorre absorção, em média, de 14% da dose administrada, e nos pulmões, acréscimo de 2% na dose administrada. Nos pacientes com distância látero-lateral maior que 35 cm as variações entre as doses calculadas e medidas podem chegar a 30% da dose desejada, sem o uso de filtros compensadores. CONCLUSÃO: Os valores medidos das doses absorvidas nos diversos pontos anatômicos, comparados aos valores desejados (teóricos), apresentam tolerância de ±10%, considerando-se as diferenças anatômicas existentes, quando utilizados os fatores de calibração individuais das pastilhas.
Resumo:
The magnetostratigraphic analysis of the middle to late Miocene continental deposits from the Valles-Penedes basin, combined with its well-documented fossil mammal record, provides a well-resoluted chronology for the upper basin infill. It is based on the biostratigraphic and magnetostratigraphic cross-correlation of 18 sections throughout the alluvial and transitional/shallow marine sequences in the Western Valles area. The biostratigraphic framework consists of 24 mammal localities of upper Aragonian and Vallesian age. Correlation of the studied sections to the geomagnetic polarity time scale (GPTS) is based on the distinctive pattern of local magnetozones, as well as the radiometric age of the late Vallesian fauna from the Bicorp Basin (9.6 + 0.3 Ma) and the known relationship of the late Vallesian assemblages with marine beds belonging to the planktonic forarninifera N16 zone. It has led to an absolute dating of the fauna1 events and a precise chronostratigraphy of the Vallesian marnrnal stage in its type area. The Hipparion First Appearance Datum (FAD) defines the lower Vallesian boundary and is dated at 11.1 Ma, at the base of chron C5r. ln. It is in good agreement with radiometric ages from the early Hipparion bearing sites in the Vienna Basin (1 1.1 * 0.5 Ma) and the classic Howenegg locality in Germany (10.8 * 0.3 Ma). It also agrees with the age of the turkish localities of Yailacilar (1 1.6 + 0.25 Ma) and Yenieskihisar-2 (1 1.1 * 0.2 Ma) with absence of Hipparion. Al1 these support the isochrony of the dispersa1 of Hipparion throughout the Mediterranean region. A possible isochrony at a larger geographical scale (Old World, Mesogea) must await more reliable ages of the Hipparion FAD in Asia and Africa. The Cricetulodon FAD that defines the MN9a/MN9b boundary occurs at the middle part of C5n. Assuming an on average constant sedimentation rate, this datum has an age of approximately 10.4 Ma. The earlyllate Vallesian boundary is marked by one of the most distinct fauna1 events of the late Neogene: the dispersa1 of the muridae Progonomys into Europe and North Africa, which coincides with an important macromarnmal turnover. The first extensive appearance of Progonomys in Europe (MN9ÃMN10 boundary) is dated at 9.7 Ma (C4Ar3r), showing a remarkable diachrony with the Himalayan region. F9i d lly, the FAD of Rotundomys bressnnus occurs in the upper part of C4Ar.ln (9.2-9.3 Ma). The Vallesian spans 2.4 Myr, from 11.1 Ma (CSr.ln) to 8.7 Ma (C4An), and correlates to the early Tortonian.
Resumo:
El hipódromo de Constantinopla se convirtió, desde su reconstrucción monumental por Constantino I hasta su saqueo por los cruzados en 1204, en el principal escenario de manifestación de la majestad imperial. Centro de propaganda política por excelencia, este edificio tomó como modelo el Circo Máximo de Roma, con quien guardaba más parecido que con sus homónimos griegos. Todo en él estaba proyectado para realzar la idea de la soberanía del basileo: su disposición arquitectónica, unido al complejo palacial por medio de la kathisma -el palco imperial y el palacio del hipódromo con el mismo nombre-; la decoración, compuesta por obeliscos, columnas y otros elementos llenos de simbolismo solar, así como por una gran cantidad de esculturas destruidas en el saqueo de 1204; y la misma liturgia del hipódromo, un complejo ceremonial destinado a ensalzar al emperador como vencedor perpetuo.
Resumo:
Junto a los medios puramente administrativos orientados a la protección del medio ambiente, cada día adquieren mayor protagonismo los que pueden adoptarse desde el ámbito del derecho financiero, del ingreso y gasto públicos. El trabajo se ha estructurado en cuatro apartados: aguas, residuos sólidos, polución atmosférica y contaminación acústica.
Resumo:
OBJETIVO: Desenvolver uma câmara de ionização de placas paralelas de dupla face para determinação de kerma no ar e taxa de kerma no ar em campos de radiação-X utilizados em radiografia convencional e mamografia. MATERIAIS E MÉTODOS: A câmara desenvolvida tem janelas de entrada de poliéster aluminizado, elétrodos internos e anéis de guarda de alumínio em uma face (face A) e de grafite na outra (face G). Neste trabalho foram testadas as características operacionais de linearidade, dependência angular e energética de resposta. RESULTADOS: A linearidade de resposta foi de 0,86% para a face A e de 0,92% para a face G. Para ângulos de incidência da radiação de 0° a ± 5°, a variação da resposta relativa foi menor que 0,8% para ambas as faces da câmara. A dependência energética de resposta foi de 0,8% para a face A nas qualidades de raios-X para diagnóstico convencional e de 2,4% para a face G da câmara nas qualidades de raios-X para mamografia. CONCLUSÃO: Esta câmara pode ser utilizada rotineiramente na determinação de kerma no ar e taxa de kerma no ar em feixes de raios-X utilizados em radiografia convencional e mamografia.
Resumo:
OBJETIVO: Este trabalho analisa as conseqüências da irradiação-X no desenvolvimento do sistema nervoso de fetos de ratos. MATERIAIS E MÉTODOS: O trabalho foi constituído de 10 Rattus norvegicus albinos, Wistar, fêmeas, grávidas, com idade de oito semanas. Cinco ratas fêmeas constituíram o grupo controle e outras cinco tiveram suas regiões abdominais expostas por 30 segundos a uma dose de 0,3 Gy proveniente de um aparelho odontológico Gnatus de 70 kV e 10 mA. No 17º dia gestacional, ambos os grupos foram submetidos a histerectomia. As seções selecionadas foram examinadas para análise cerebral comparativa entre os grupos. RESULTADOS: O exame clínico revelou não haver diferenças morfológicas entre os grupos controle e experimental e nenhum dos animais apresentou anormalidades grosseiras. Vinte e sete por cento dos animais do grupo experimental apresentaram hemorragia cerebral moderada e 73% apresentaram hemorragia severa e danos no tecido nervoso. Nenhum animal do grupo controle apresentou hemorragia cerebral ou danificações de tecido nervoso. CONCLUSÃO: Estas evidências demonstram que pequenas doses de radiação-X podem causar hemorragias cerebrais e, conseqüentemente, lesão tecidual nervosa.
Resumo:
El artículo expone la actividad de las instituciones en el ámbito de la política europea de medio ambiente. Se analiza también el papel de la Unión Europea en materia de cambio climático y biodiversidad.
Resumo:
OBJETIVO: Este trabalho avalia a distribuição de dose recebida por médicos envolvidos em procedimentos hemodinâmicos de angioplastia coronária e coronariografia. A influência de alguns fatores, como o modo de fluoroscopia pulsado ou contínuo e o local de acesso à veia e/ou artéria, foi investigada. MATERIAIS E MÉTODOS: Para esta avaliação foram feitas medições utilizando dosímetros termoluminescentes de LiF:Mg,Ti, posicionados em sete diferentes pontos do corpo dos profissionais: mãos, joelho, pescoço, testa e tórax, por dentro e por fora do avental de chumbo. A dose foi avaliada, por exame, nos médicos que executaram os procedimentos (30 de angioplastia e 60 de coronariografia). Os dosímetros termoluminescentes foram calibrados na grandeza operacional equivalente de dose pessoal, Hp(d), nas profundidades de 0,07, 3 e 10 mm. RESULTADOS: Os resultados mostram a importância do uso do protetor de tireóide e avental de chumbo para a redução da dose recebida pelos médicos. As doses dos profissionais que executaram procedimentos por via braquial usando modo contínuo de fluoroscopia foram mais altas do que os que executaram por via femoral e modo pulsado de fluoroscopia. CONCLUSÃO: Este estudo mostra a necessidade de medidas adicionais de proteção e a implementação de mecanismos de treinamento em proteção radiológica para os médicos que trabalham com cardiologia intervencionista.
Resumo:
OBJETIVO: Analisar o produto dose-área, a dose de entrada na pele do paciente e as doses relativas à fluoroscopia e às radiografias em exames de cistouretrografia miccional em crianças. MATERIAIS E MÉTODOS: Foram avaliados os procedimentos em 37 pacientes, realizados por quatro médicos do serviço. As medições foram realizadas com um equipamento composto de uma câmara de ionização acoplada diretamente à saída do tubo de raios X e um eletrômetro (Diamentor) ligado diretamente ao computador, para a coleta dos dados. RESULTADOS: Foi observada alguma heterogeneidade na realização do procedimento, que não segue padrão de técnica radiográfica. São realizadas em média 11 radiografias por exame, usando tempo longo de fluoroscopia, com dose média final mais alta que a encontrada em referências da literatura. CONCLUSÃO: A adoção da técnica de alta quilovoltagem nas radiografias e o uso restrito da fluoroscopia podem proporcionar importante redução das doses durante a realização deste procedimento, porque o maior contribuinte para as altas doses verificadas foi a utilização da fluoroscopia.