970 resultados para RF stacking
Resumo:
This study focused on identifying various system boundaries and evaluating methods of estimating energy performance of biogas production. First, the output-input ratio method used for evaluating energy performance from the system boundaries was reviewed. Secondly, ways to assess the efficiency of biogas use and parasitic energy demand were investigated. Thirdly, an approach for comparing biogas production to other energy production methods was evaluated. Data from an existing biogas plant, located in Finland, was used for the evaluation of the methods. The results indicate that calculating and comparing the output-input ratios (Rpr1, Rpr2, Rut, Rpl and Rsy) can be used in evaluating the performance of biogas production system. In addition, the parasitic energy demand calculations (w) and the efficiency of utilizing produced biogas (η) provide detailed information on energy performance of the biogas plant. Furthermore, Rf and energy output in relation to total solid mass of feedstock (FO/TS) are useful in comparing biogas production with other energy recovery technologies. As a conclusion it is essential for the comparability of biogas plants that their energy performance would be calculated in a more consistent manner in the future.
Resumo:
Lactating rats show less noise-induced freezing and fewer inhibitory responses on the 6th day post-delivery when submitted to water and food deprivation in a classical conflict paradigm. Lactating mice go more often to the illuminated chamber in a light-dark cage and stay longer in it than virgin females. The present study was designed to assess the influence of this physiological state, i.e. lactation, on the elevated plus maze (EPM) and open-field behavior in adult female rats. Total (TL) and central (CL) locomotion and rearing (RF) frequencies were measured in an open-field. Number of entries into the open and closed arms as well as the time spent in each of these arms were measured in the EPM. Percent time spent and number of entries into the open arms were calculated and compared. In the open-field, TL was significantly decreased (115 ± 10.6 vs 150 ± 11.6) while CL and RF did not differ from those presented by virgin rats. In the EPM, lactating rats displayed a significant reduction in percent time spent (10.9 ± 1.5 vs 17.4 ± 2.3) in the open arms as well as a tendency to a reduction in percent entries into the open arms (35.7 ± 4.7 vs 45.7 ± 4.3). These results show that the physiological state of lactation modulates the open-field and EPM behaviors in rats
Resumo:
In the design of electrical machines, efficiency improvements have become very important. However, there are at least two significant cases in which the compactness of electrical machines is critical and the tolerance of extremely high losses is valued: vehicle traction, where very high torque density is desired at least temporarily; and direct-drive wind turbine generators, whose mass should be acceptably low. As ever higher torque density and ever more compact electrical machines are developed for these purposes, thermal issues, i.e. avoidance of over-temperatures and damage in conditions of high heat losses, are becoming of utmost importance. The excessive temperatures of critical machine components, such as insulation and permanent magnets, easily cause failures of the whole electrical equipment. In electrical machines with excitation systems based on permanent magnets, special attention must be paid to the rotor temperature because of the temperature-sensitive properties of permanent magnets. The allowable temperature of NdFeB magnets is usually significantly less than 150 ˚C. The practical problem is that the part of the machine where the permanent magnets are located should stay cooler than the copper windings, which can easily tolerate temperatures of 155 ˚C or 180 ˚C. Therefore, new cooling solutions should be developed in order to cool permanent magnet electrical machines with high torque density and because of it with high concentrated losses in stators. In this doctoral dissertation, direct and indirect liquid cooling techniques for permanent magnet synchronous electrical machines (PMSM) with high torque density are presented and discussed. The aim of this research is to analyse thermal behaviours of the machines using the most applicable and accurate thermal analysis methods and to propose new, practical machine designs based on these analyses. The Computational Fluid Dynamics (CFD) thermal simulations of the heat transfer inside the machines and lumped parameter thermal network (LPTN) simulations both presented herein are used for the analyses. Detailed descriptions of the simulated thermal models are also presented. Most of the theoretical considerations and simulations have been verified via experimental measurements on a copper tooth-coil (motorette) and on various prototypes of electrical machines. The indirect liquid cooling systems of a 100 kW axial flux (AF) PMSM and a 110 kW radial flux (RF) PMSM are analysed here by means of simplified 3D CFD conjugate thermal models of the parts of both machines. In terms of results, a significant temperature drop of 40 ̊C in the stator winding and 28 ̊C in the rotor of the AF PMSM was achieved with the addition of highly thermally conductive materials into the machine: copper bars inserted in the teeth, and potting material around the end windings. In the RF PMSM, the potting material resulted in a temperature decrease of 6 ̊C in the stator winding, and in a decrease of 10 ̊C in the rotor embedded-permanentmagnets. Two types of unique direct liquid cooling systems for low power machines are analysed herein to demonstrate the effectiveness of the cooling systems in conditions of highly concentrated heat losses. LPTN analysis and CFD thermal analysis (the latter being particularly useful for unique design) were applied to simulate the temperature distribution within the machine models. Oil-immersion cooling provided good cooling capability for a 26.6 kW PMSM of a hybrid vehicle. A direct liquid cooling system for the copper winding with inner stainless steel tubes was designed for an 8 MW directdrive PM synchronous generator. The design principles of this cooling solution are described in detail in this thesis. The thermal analyses demonstrate that the stator winding and the rotor magnet temperatures are kept significantly below their critical temperatures with demineralized water flow. A comparison study of the coolant agents indicates that propylene glycol is more effective than ethylene glycol in arctic conditions.
Resumo:
Activation of Th1 or Th2 cells is associated with production of specific immunoglobulin isotypes, offering the opportunity to use antibody measurement for evaluation of T cell function. Schistosomiasis and visceral leishmaniasis are diseases associated with Th2 activation. However, an IgE response is not always detected in these patients. In the present study we evaluated specific IgE antibodies to S. mansoni and L. chagasi antigens by ELISA after depletion of serum IgG with protein G immobilized on Sepharose beads or RF-absorbent (purified sheep IgG antibodies anti-human IgG). In schistosomiasis patients, specific IgE to SWAP antigen was demonstrable in only 10 of 21 patients (48%) (mean absorbance ± SD = 0.102 ± 0.195) when unabsorbed serum was used. Depletion of IgG with protein G increased the number of specific IgE-positive tests to 13 (62%) and the use of RF-absorbent increased the number of positive results to 20 (95%) (mean absorbances ± SD = 0.303 ± 0.455 and 0.374 ± 0.477, respectively). Specific IgE anti-L. chagasi antibodies were not detected in unabsorbed serum from visceral leishmaniasis patients. When IgG was depleted with protein G, IgE antibodies were detected in only 3 (11%) of 27 patients, and the use of RF-absorbent permitted the detection of this isotype in all 27 visceral leishmaniasis sera tested (mean absorbance ± SD = 0.104 ± 0.03). These data show that the presence of IgG antibodies may prevent the detection of a specific IgE response in these parasite diseases. RF-absorbent, a reagent that blocks IgG-binding sites and also removes rheumatoid factor, was more efficient than protein G for the demonstration of specific IgE antibodies.
Resumo:
Työn tavoitteena oli suunnitella vetokoneen linjalle pinoamislaite. Laitteen tehtävänä on pinota yksittäin vetokoneelta tulevista tuotteista asiakasvaatimusten mukaisia pinoja. Laitteen suunnittelu toteutettiin käyttämällä systemaattisen koneensuunnittelun metodia. Diplomityö rajattiin koskemaan laitteen mekaanisten ratkaisujen suunnittelua. Suunnittelussa huomioitiin linjan asettamat vaatimukset, jotka koskevat sekä tuotantomäärää että tilojen käyttöä. Laitteen suunnittelussa ja mallinnuksessa käytettiin Solidworksin 3D-mallinnusohjelmaa. Mallinnettuja ratkaisuvaihtoehtoja verrattiin keskenään. Parhaiten vaatimusluettelossa esitetyt vaatimukset täyttänyt ratkaisumalli valittiin kehitettäväksi. Suunnitellusta laitteesta valmistettiin työpiirustukset sekä kokoonpanokuvat.
Resumo:
Antibodies to citrullinated peptides are highly specific for rheumatoid arthritis (RA) and represent a significant risk factor for undifferentiated polyarthritis. This prognostic ability may be related to the very diagnostic performance of these autoantibodies, since RA is a more erosive disease than other forms of arthritis. The present study evaluated an association of antibodies to citrullinated peptides and the rate of joint destruction in patients with a well-established diagnosis of RA. Seventy-one patients with RA were evaluated in 1994 and again in 2002 (functional class, joint count, Health Assessment Questionnaire score, hands X-ray). Autoantibodies (rheumatoid factor (RF), anti-perinuclear factor, anti-cyclic citrullinated peptide (CCP) antibodies) and Sharp's index were analyzed blindly. Delta Sharp was calculated as the difference in Sharp's index obtained in 1994 and 2002. During the follow-up the Health Assessment Questionnaire score increased from 0.91 ± 0.74 to 1.39 ± 0.72 (P < 0.001). Similarly, the number of swollen joints increased from 4.6 ± 5.71 to 6.4 ± 4.1 (P = 0.002). The frequency of autoantibodies and anti-CCP titer remained stable; however, serum RF concentration increased from 202.8 ± 357.6 to 416.6 ± 636.5 IU/mL (P = 0.003). Sharp's index increased from 56.7 ± 62.1 to 92.4 ± 80.9 (P < 0.001). No correlation was observed between Delta Sharp and the presence of RF, anti-perinuclear factor, and anti-CCP antibodies at baseline. Antibodies to citrullinated epitopes are specific and early markers for the diagnosis of RA but do not seem to be associated with the rate of joint destruction in patients with a well-established diagnosis of RA.
Resumo:
The objective of the present research was to evaluate the usefulness of anti-cyclic citrullinated peptide (anti-CCP) antibodies and the IgM rheumatoid factor (IgM RF) test for the differential diagnosis of leprosy with articular involvement and rheumatoid arthritis (RA). Anti-CCP antibodies and IgM RF were measured in the sera of 158 leprosy patients (76 with and 82 without articular involvement), 69 RA patients and 89 healthy controls. Leprosy diagnosis was performed according to Ridley and Jopling classification criteria and clinical and demographic characteristics of leprosy patients were collected by a standard questionnaire. Leprosy patients with any concomitant rheumatic disease were excluded. Serum samples were obtained from all participants and frozen at _20°C. Measurement of anti-CCP antibodies and IgM RF were performed by ELISA, using a commercial second-generation kit, and the latex agglutination test, respectively. Anti-CCP antibodies and IgM RF were detected in low frequencies (2.6 and 1.3%, respectively) in leprosy patients and were not associated with articular involvement. Among healthy individuals both anti-CCP antibodies and IgM RF were each detected in 3.4% of the subjects. In contrast, in the RA group, anti-CCP antibodies were present in 81.2% and IgM RF in 62.3%. In the present study, both anti-CCP antibodies and IgM RF showed good positive predictive value for RA, helping to discriminate between RA and leprosy patients with articular involvement. However, anti-CCP antibodies were more specific for RA diagnosis in the population under study.
Resumo:
This study was designed to assess the influence of resistance training on salivary immunoglobulin A (IgA) levels and hormone profile in sedentary adults with Down syndrome (DS). A total of 40 male adults with DS were recruited for the trial through different community support groups for people with intellectual disabilities. All participants had medical approval for participation in physical activity. Twenty-four adults were randomly assigned to perform resistance training in a circuit with six stations, 3 days per week for 12 weeks. Training intensity was based on functioning in the eight-repetition maximum (8RM) test for each exercise. The control group included 16 age-, gender-, and BMI-matched adults with DS. Salivary IgA, testosterone, and cortisol levels were measured by ELISA. Work task performance was assessed using the repetitive weighted-box-stacking test. Resistance training significantly increased salivary IgA concentration (P=0.0120; d=0.94) and testosterone levels (P=0.0088; d=1.57) in the exercising group. Furthermore, it also improved work task performance. No changes were seen in the controls who had not exercised. In conclusion, a short-term resistance training protocol improved mucosal immunity response as well as salivary testosterone levels in sedentary adults with DS.
Resumo:
A extração de pigmentos carotenóides constitui uma possível alternativa, de grande agregação de valor, para o aproveitamento da cabeça do camarão Litopenaeus vannamei. O objetivo do presente trabalho foi a identificação, a extração e a quantificação dos principais pigmentos desta matéria-prima, coletados a partir de uma planta de beneficiamento de camarão no Ceará - Brasil. Após cocção dos resíduos a 100 °C, na proporção 1:2 cabeça de camarão e água durante 15 minutos, obteve-se uma pasta de pigmentos brutos extraindo-se os carotenóides com acetona resfriada e, posteriormente, com hexano, obtendo a fase pigmento-hexano. Obteve-se também a fase DMSO, após o material ser particionado com dimetilsulfóxido, e uma fração acidificada. Estas frações sofreram evaporação e secagem, sendo os carotenóides identificados em coluna aberta, utilizando-se o parâmetro de eluição das frações, o espectro de absorção visível e o valor de Rf na camada delgada de sílica gel. Os espectros de absorção de cada fração foram obtidos a 350 a 550 nm e quantificados por cromatografia de camada delgada. Para o cálculo de carotenóides totais (37,62 µg.g-1 da pasta de pigmentos), utilizou-se o somatório das frações hexano, DMSO e acidificada, e coeficientes de extinção 2592, 2100 e 1690 referentes ao beta-caroteno, astaxantina e astaceno, respectivamente. A astaxantina foi o pigmento mais abundante (45,5%), seguido do beta-caroteno-5,6-epóxido (33,5%) e do astaceno (21,0%).
Power Electronic Converters in Low-Voltage Direct Current Distribution – Analysis and Implementation
Resumo:
Over the recent years, smart grids have received great public attention. Many proposed functionalities rely on power electronics, which play a key role in the smart grid, together with the communication network. However, “smartness” is not the driver that alone motivates the research towards distribution networks based on power electronics; the network vulnerability to natural hazards has resulted in tightening requirements for the supply security, set both by electricity end-users and authorities. Because of the favorable price development and advancements in the field, direct current (DC) distribution has become an attractive alternative for distribution networks. In this doctoral dissertation, power electronic converters for a low-voltage DC (LVDC) distribution system are investigated. These include the rectifier located at the beginning of the LVDC network and the customer-end inverter (CEI) on the customer premises. Rectifier topologies are introduced, and according to the LVDC system requirements, topologies are chosen for the analysis. Similarly, suitable CEI topologies are addressed and selected for study. Application of power electronics into electricity distribution poses some new challenges. Because the electricity end-user is supplied with the CEI, it is responsible for the end-user voltage quality, but it also has to be able to supply adequate current in all operating conditions, including a short-circuit, to ensure the electrical safety. Supplying short-circuit current with power electronics requires additional measures, and therefore, the short-circuit behavior is described and methods to overcome the high-current supply to the fault are proposed. Power electronic converters also produce common-mode (CM) and radio-frequency (RF) electromagnetic interferences (EMI), which are not present in AC distribution. Hence, their magnitudes are investigated. To enable comprehensive research on the LVDC distribution field, a research site was built into a public low-voltage distribution network. The implementation was a joint task by the LVDC research team of Lappeenranta University of Technology and a power company Suur-Savon S¨ahk¨o Oy. Now, the measurements could be conducted in an actual environment. This is important especially for the EMI studies. The main results of the work concern the short-circuit operation of the CEI and the EMI issues. The applicability of the power electronic converters to electricity distribution is demonstrated, and suggestions for future research are proposed.