980 resultados para Quantum mechanical method


Relevância:

30.00% 30.00%

Publicador:

Resumo:

We provide an analysis of basic quantum-information processing protocols under the effect of intrinsic nonidealities in cluster states. These nonidealities are based on the introduction of randomness in the entangling steps that create the cluster state and are motivated by the unavoidable imperfections faced in creating entanglement using condensed-matter systems. Aided by the use of an alternative and very efficient method to construct cluster-state configurations, which relies on the concatenation of fundamental cluster structures, we address quantum-state transfer and various fundamental gate simulations through noisy cluster states. We find that a winning strategy to limit the effects of noise is the management of small clusters processed via just a few measurements. Our study also reinforces recent ideas related to the optical implementation of a one-way quantum computer.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An overview of a many-body approach to calculation of electronic transport in molecular systems is given. The physics required to describe electronic transport through a molecule at the many-body level, without relying on commonly made assumptions such as the Landauer formalism or linear response theory, is discussed. Physically, our method relies on the incorporation of scattering boundary conditions into a many-body wavefunction and application of the maximum entropy principle to the transport region. Mathematically, this simple physical model translates into a constrained nonlinear optimization problem. A strategy for solving the constrained optimization problem is given. (C) 2004 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A method for correlated quantum electron-ion dynamics is combined with a method for electronic open boundaries to simulate in real time the heating, and eventual equilibration at an elevated vibrational energy, of a quantum ion under current flow in an atomic wire, together with the response of the current to the ionic heating. The method can also be used to extract inelastic current voltage corrections under steady-state conditions. However, in its present form the open-boundary method contains an approximation that limits the resolution of current-voltage features. The results of the simulations are tested against analytical results from scattering theory. Directions for the improvement of the method are summarized at the end.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The photophysical properties of lanthanide complexes have been studied extensively; however, fundamental parameters such as the intrinsic quantum yield as well as radiative and nonradiative decay rates are difficult or even impossible to measure experimentally. Herein, a photoacoustic (PA) method is proposed to determine the intrinsic quantum yield of lanthanide complexes with lifetimes in the order of milliseconds. This method is used to determine the intrinsic quantum yields for europium (III)-containing metallomesogens as well as terbium(III) complexes. The results show that the PA signal is sensitive to both the lifetime and the ratio of the fast-to-slow heat component of the samples. It is found that there is an efficient ligand sensitization and a moderate intrinsic quantum yield for the complexes. The intrinsic quantum yield of Eu3+ in the metallomesogens exhibits an obvious increase upon the isotropic liquid to smectic A transition. The proposed PA method is quite simple, and con contribute to a clearer understanding of the photophysical processes in luminescent lanthanide complexes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Polymethyl methacrylate (PMMA) bone cement–multiwalled carbon nanotube (MWCNT) nanocomposites with a weight loading of 0.1% were prepared using 3 different methods of MWCNT incorporation. The mechanical and thermal properties of the resultant nanocomposite cements were characterised in accordance with the international standard for acrylic resin cements. The mechanical properties of the resultant nanocomposite cements were influenced by the type of MWCNT and method of incorporation used. The exothermic polymerisation reaction for the PMMA bone cement was significantly reduced when thermally conductive functionalised MWCNTs were added. This reduction in exotherm translated in a decrease in thermal necrosis index value of the respective nanocomposite cements, which potentially could reduce the hyperthermia experienced in vivo. The morphology and degree of dispersion of the MWCNTs in the PMMA matrix at different scales were analysed using scanning electron microscopy. Improvements in mechanical properties were attributed to the MWCNTs arresting/retarding crack propagation through the cement by providing a bridging effect into the wake of the crack, normal to the direction of crack growth. MWCNT agglomerations were evident within the cement microstructure, the degree of these agglomerations was dependent on the method used to incorporate the MWCNTs into the cement.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Index properties such as the liquid limit and plastic limit are widely used to evaluate certain geotechnical parameters of fine-grained soils. Measurement of the liquid limit is a mechanical process, and the possibility of errors occurring during measurement is not significant. However, this is not the case for plastic limit testing, despite the fact that the current method of measurement is embraced by many standards around the world. The method in question relies on a fairly crude procedure known widely as the ‘thread rolling' test, though it has been the subject of much criticism in recent years. It is essential that a new, more reliable method of measuring the plastic limit is developed using a mechanical process that is both consistent and easily reproducible. The work reported in this paper concerns the development of a new device to measure the plastic limit, based on the existing falling cone apparatus. The force required for the test is equivalent to the application of a 54 N fast-static load acting on the existing cone used in liquid limit measurements. The test is complete when the relevant water content of the soil specimen allows the cone to achieve a penetration of 20 mm. The new technique was used to measure the plastic limit of 16 different clays from around the world. The plastic limit measured using the new method identified reasonably well the water content at which the soil phase changes from the plastic to the semi-solid state. Further evaluation was undertaken by conducting plastic limit tests using the new method on selected samples and comparing the results with values reported by local site investigation laboratories. Again, reasonable agreement was found.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A dynamical method for inelastic transport simulations in nanostructures is compared to a steady-state method based on nonequilibrium Green's functions. A simplified form of the dynamical method produces, in the steady state in the weak-coupling limit, effective self-energies analogous to those in the Born approximation due to electron-phonon coupling. The two methods are then compared numerically on a resonant system consisting of a linear trimer weakly embedded between metal electrodes. This system exhibits an enhanced heating at high biases and long phonon equilibration times. Despite the differences in their formulation, the static and dynamical methods capture local current-induced heating and inelastic corrections to the current with good agreement over a wide range of conditions, except in the limit of very high vibrational excitations where differences begin to emerge.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We draw an explicit connection between the statistical properties of an entangled two-mode continuous variable (CV) resource and the amount of entanglement that can be dynamically transferred to a pair of noninteracting two-level systems. More specifically, we rigorously reformulate entanglement-transfer process by making use of covariance matrix formalism. When the resource state is Gaussian, our method makes the approach to the transfer of quantum correlations much more flexible than in previously considered schemes and allows the straightforward inclusion of the effects of noise affecting the CV system. Moreover, the proposed method reveals that the use of de-Gaussified two-mode states is almost never advantageous for transferring entanglement with respect to the full Gaussian picture, despite the entanglement in the non-Gaussian resource can be much larger than in its Gaussian counterpart. We can thus conclude that the entanglement-transfer map overthrows the

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The motion of a clarinet reed that is clamped to a mouthpiece and supported by a lip is simulated in the time-domain using finite difference methods. The reed is modelled as a bar with non-uniform cross section, and is described using a one-dimensional, fourth-order partial differential equation. The interactions with the mouthpiece Jay and the player's lip are taken into account by incorporating conditional contact forces in the bar equation. The model is completed by clamped-free boundary conditions for the reed. An implicit finite difference method is used for discretising the system, and values for the physical parameters are chosen both from laboratory measurements and by accurate tuning of the numerical simulations. The accuracy of the numerical system is assessed through analysis of frequency warping effects and of resonance estimation. Finally, the mechanical properties of the system are studied by analysing its response to external driving forces. In particular, the effects of reed curling are investigated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The overall quantum efficiency in surface plasmon (SP) enhanced Schottky barrier photodetectors is examined by considering both the external and internal yield. The external yield is considered through calculations of absorption and transmission of light in a configuration that allows reflectance minimization due to SP excitation. Following a Monte Carlo method, a procedure is presented to estimate the internal yield while taking into account the effect of elastic and inelastic scattering processes on excited carriers subsequent to photon absorption. The relative importance of internal photoemission and band-to-band contributions to the internal yield is highlighted along with the variation of the yield as a function of wavelength, metal thickness and other salient parameters of the detector. (C) 2002 Elsevier Science Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

As a potential alternative to CMOS technology, QCA provides an interesting paradigm in both communication and computation. However, QCAs unique four-phase clocking scheme and timing constraints present serious timing issues for interconnection and feedback. In this work, a cut-set retiming design procedure is proposed to resolve these QCA timing issues. The proposed design procedure can accommodate QCAs unique characteristics by performing delay-transfer and time-scaling to reallocate the existing delays so as to achieve efficient clocking zone assignment. Cut-set retiming makes it possible to effectively design relatively complex QCA circuits that include feedback. It utilizes the similar characteristics of synchronization, deep pipelines and local interconnections common to both QCA and systolic architectures. As a case study, a systolic Montgomery modular multiplier is designed to illustrate the procedure. Furthermore, a nonsystolic architecture, an S27 benchmark circuit, is designed and compared with previous designs. The comparison shows that the cut-set retiming method achieves a more efficient design, with a reduction of 22%, 44%, and 46% in terms of cell count, area, and latency, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nonclassical states of a mechanical mode at nonzero temperature are achieved in a scheme that combines radiation-pressure coupling to a light field and photon subtraction. The scheme embodies an original and experimentally realistic way to obtain mesoscopic quantumness by putting together two mature technologies for quantum control. The protocol is quasi-insensitive to mechanical damping.