956 resultados para Projectile points
Resumo:
This study analyses the national scientific production about college students' residence halls. The country's main data bases and electronic sites of several Brazilian higher education institutions were checked and 23 studies, published between 2000 and 2009, were found. The results of our analysis point to different focuses, which can be grouped into three categories: students who live in residence halls, residence halls themselves and actions for student assistance. Although there is large foreign scientific production about college student housing, the national production on this theme is still scarce, and the idea of student residence halls as educational spaces is still very incipient. The study points out to the need for investigating the living conditions in these places, and the impacts of this kind of habitation on students. Considering that student housing is an institutional responsibility, these studies potentially subsidize measures for proper educational conditions for college students.
Resumo:
PURPOSE: To compare the Full Threshold (FT) and SITA Standard (SS) strategies in glaucomatous patients undergoing automated perimetry for the first time. METHODS: Thirty-one glaucomatous patients who had never undergone perimetry underwent automated perimetry (Humphrey, program 30-2) with both FT and SS on the same day, with an interval of at least 15 minutes. The order of the examination was randomized, and only one eye per patient was analyzed. Three analyses were performed: a) all the examinations, regardless of the order of application; b) only the first examinations; c) only the second examinations. In order to calculate the sensitivity of both strategies, the following criteria were used to define abnormality: glaucoma hemifield test (GHT) outside normal limits, pattern standard deviation (PSD) <5%, or a cluster of 3 adjacent points with p<5% at the pattern deviation probability plot. RESULTS: When the results of all examinations were analyzed regardless of the order in which they were performed, the number of depressed points with p<0.5% in the pattern deviation probability map was significantly greater with SS (p=0.037), and the sensitivities were 87.1% for SS and 77.4% for FT (p=0.506). When only the first examinations were compared, there were no statistically significant differences regarding the number of depressed points, but the sensitivity of SS (100%) was significantly greater than that obtained with FT (70.6%) (p=0.048). When only the second examinations were compared, there were no statistically significant differences regarding the number of depressed points, and the sensitivities of SS (76.5%) and FT (85.7%) (p=0.664). CONCLUSION: SS may have a higher sensitivity than FT in glaucomatous patients undergoing automated perimetry for the first time. However, this difference tends to disappear in subsequent examinations.
Resumo:
OBJECTIVE: To evaluate the learning effect, short-term fluctuation and long-term fluctuation in healthy subjects undergoing frequency doubling perimetry (FDP). METHODS: Twenty healthy young subjects underwent FDT (program N30, full threshold) in one eye (right). Each subject was tested once in the first three sessions and three times in the fourth session. Both short- and long-term fluctuations were studied as the average fluctuation of all the tested points or as a point-to-point fluctuation. To study the learning effect, the MDs values of the first session were compared to the second, third and fourth sessions. RESULTS: In the short-term analysis (3 examination done in the last session), the total mean sensitivity was 31.91 ± 1.20 dB and the mean MD and PSD were 0.84 ± 1.85 and 3.73 ± 1.55 dB, respectively. The average short-term fluctuation was 1.72 ± 0.38 dB. When the four examination, performed at different visits, were compared, the average mean sensitivity of all sessions and the average long-term fluctuation were 31.75 ± 1.11 and 2.16 ± 0.26 dB, respectively. The MD averages of the first, second, third and fourth tests were 0.11 ± 2.14 dB, 0.47 ± 1.64 dB, 1.16 ± 1.62 dB and 0.98 ± 1.92 dB respectively. The MD difference between the first and the third and between the first and the fourth examinations were statistically significant (p<0.05). CONCLUSION: The threshold sensitivity detected by FDP is influenced by both short- and long-term fluctuations. We observed a mild learning effect that shoud be taken into account whenever a patient undergoes this test for the first time.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física