935 resultados para Pre-clinical tests
Resumo:
In patients diagnosed with pharmaco-resistant epilepsy, cerebral areas responsible for seizure generation can be defined by performing implantation of intracranial electrodes. The identification of the epileptogenic zone (EZ) is based on visual inspection of the intracranial electroencephalogram (IEEG) performed by highly qualified neurophysiologists. New computer-based quantitative EEG analyses have been developed in collaboration with the signal analysis community to expedite EZ detection. The aim of the present report is to compare different signal analysis approaches developed in four different European laboratories working in close collaboration with four European Epilepsy Centers. Computer-based signal analysis methods were retrospectively applied to IEEG recordings performed in four patients undergoing pre-surgical exploration of pharmaco-resistant epilepsy. The four methods elaborated by the different teams to identify the EZ are based either on frequency analysis, on nonlinear signal analysis, on connectivity measures or on statistical parametric mapping of epileptogenicity indices. All methods converge on the identification of EZ in patients that present with fast activity at seizure onset. When traditional visual inspection was not successful in detecting EZ on IEEG, the different signal analysis methods produced highly discordant results. Quantitative analysis of IEEG recordings complement clinical evaluation by contributing to the study of epileptogenic networks during seizures. We demonstrate that the degree of sensitivity of different computer-based methods to detect the EZ in respect to visual EEG inspection depends on the specific seizure pattern.
Resumo:
The purpose of this study was to evaluate if pre-anaesthetic thoracic radiographs contribute to the anaesthetic management of trauma patients by comparing American Society of Anesthesiologists Physical Status Classification (ASA grade) with and without information from thoracic radiography findings. Case records of 157 dogs and cats being anaesthetized with or without post-traumatic, pre-anaesthetic chest radiographs were retrospectively evaluated for clinical parameters, radiographic abnormalities and anaesthetic protocol. Animals were retrospectively assigned an ASA grade. ASA grades, clinical signs of respiratory abnormalities and anaesthesia protocols were compared between animals with and without chest radiographs. The group of animals without pre-anaesthetic radiographs was anaesthetized earlier after trauma and showed less respiratory abnormalities at presentation. The retrospectively evaluated ASA grade significantly increased with the information from thoracic radiography. Animals with a higher ASA grade were less frequently mechanically ventilated. Pre-anaesthetic radiographs may provide important information to assess the ASA grade in traumatized patients and may therefore influence the anesthesia protocol.
Resumo:
INTRODUCTION Rates of both TB/HIV co-infection and multi-drug-resistant (MDR) TB are increasing in Eastern Europe (EE). Data on the clinical management of TB/HIV co-infected patients are scarce. Our aim was to study the clinical characteristics of TB/HIV patients in Europe and Latin America (LA) at TB diagnosis, identify factors associated with MDR-TB and assess the activity of initial TB treatment regimens given the results of drug-susceptibility tests (DST). MATERIAL AND METHODS We enrolled 1413 TB/HIV patients from 62 clinics in 19 countries in EE, Western Europe (WE), Southern Europe (SE) and LA from January 2011 to December 2013. Among patients who completed DST within the first month of TB therapy, we linked initial TB treatment regimens to the DST results and calculated the distribution of patients receiving 0, 1, 2, 3 and ≥4 active drugs in each region. Risk factors for MDR-TB were identified in logistic regression models. RESULTS Significant differences were observed between EE (n=844), WE (n=152), SE (n=164) and LA (n=253) for use of combination antiretroviral therapy (cART) at TB diagnosis (17%, 40%, 44% and 35%, p<0.0001), a definite TB diagnosis (culture and/or PCR positive for Mycobacterium tuberculosis; 47%, 71%, 72% and 40%, p<0.0001) and MDR-TB prevalence (34%, 3%, 3% and 11%, p <0.0001 among those with DST results). The history of injecting drug use [adjusted OR (aOR) = 2.03, (95% CI 1.00-4.09)], prior TB treatment (aOR = 3.42, 95% CI 1.88-6.22) and living in EE (aOR = 7.19, 95% CI 3.28-15.78) were associated with MDR-TB. For 569 patients with available DST, the initial TB treatment contained ≥3 active drugs in 64% of patients in EE compared with 90-94% of patients in other regions (Figure 1a). Had the patients received initial therapy with standard therapy [Rifampicin, Isoniazid, Pyrazinamide, Ethambutol (RHZE)], the corresponding proportions would have been 64% vs. 86-97%, respectively (Figure 1b). CONCLUSIONS In EE, TB/HIV patients had poorer exposure to cART, less often a definitive TB diagnosis and more often MDR-TB compared to other parts of Europe and LA. Initial TB therapy in EE was sub-optimal, with less than two-thirds of patients receiving at least three active drugs, and improved compliance with standard RHZE treatment does not seem to be the solution. Improved management of TB/HIV patients requires routine use of DST, initial TB therapy according to prevailing resistance patterns and more widespread use of cART.
Resumo:
BACKGROUND/OBJECTIVES The purpose of this study was to compare the mechanical, structural, and aesthetic properties of two types of aesthetic coated nickel-titanium (NiTi) wires compared with comparable regular NiTi wires in the as-received state and after clinical use. MATERIALS/METHODS Sixty one subjects were randomly assigned to four groups (N = 61), two groups of coated wires and two groups of comparable, non-coated controls (n = 15/group). The period in the mouth ranged from 4 to 12 weeks after insertion. In total, 121 wires (61 retrieved and 60 as-received) were used in the study. The percentages of coating retention and loss were extrapolated from scans. A brief survey of five questions with three choices was given to all patients. Differential scanning calorimetry (DSC) and three-point bending tests were done on as-received and used wires. RESULTS The surface characterization by the percentage of resin remaining indicated that most wires in both test groups lost a significant amount of coating. A patient survey indicated that this was a noticeable feature for patients. DSC analysis of the wires indicated that the metallurgical properties of the coated wires were not similar to the uncoated wires in the as-received condition. Three-point bending results indicate a wide variation in test results with large standard deviations among all the groups. LIMITATIONS The extent of coating loss requires investigating, as do the biological properties of the detached coating. CONCLUSIONS Both wires lost a significant amount of aesthetic coating after varying periods in the mouth. The metallurgical testing of these findings may indicate that these wires perform differently in the mouth.
Resumo:
X-ray imaging is one of the most commonly used medical imaging modality. Albeit X-ray radiographs provide important clinical information for diagnosis, planning and post-operative follow-up, the challenging interpretation due to its 2D projection characteristics and the unknown magnification factor constrain the full benefit of X-ray imaging. In order to overcome these drawbacks, we proposed here an easy-to-use X-ray calibration object and developed an optimization method to robustly find correspondences between the 3D fiducials of the calibration object and their 2D projections. In this work we present all the details of this outlined concept. Moreover, we demonstrate the potential of using such a method to precisely extract information from calibrated X-ray radiographs for two different orthopedic applications: post-operative acetabular cup implant orientation measurement and 3D vertebral body displacement measurement during preoperative traction tests. In the first application, we have achieved a clinically acceptable accuracy of below 1° for both anteversion and inclination angles, where in the second application an average displacement of 8.06±3.71 mm was measured. The results of both applications indicate the importance of using X-ray calibration in the clinical routine.