939 resultados para Plycyclic Aromatic Hydrocarbons (PAHs)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

2-(2-Phenyl-1H-phenanthro-[9,10-d]imidazole-1-yl)-acetic acid (PPIA) and 2-(9-acridone)-acetic acid (AAA), two novel precolumn fluorescent derivatization reagents, have been developed and compared for analysis of primary aromatic amines by high performance liquid chromatographic fluorescence detection coupled with online mass spectrometric identification. PPIA and AAA react rapidly and smoothly with the aromatic amines on the basis of a condensation reaction using 1-ethyl-3-(3dimethylaminopropyl)-carbodiimide (EDC) as dehydrating catalyst to form stable derivatives with emission wavelengths at 380 and 440 nm, respectively. Taking six primary aromatic amines (aniline, 2-methylaniline, 2-methoxyaniline, 4-methylaniline, 4-chloroaniline, and 4-bromoaniline) as testing compounds, derivatization conditions such as coupling reagent, basic catalyst, reaction temperature and time, reaction solvent, and fluorescent labeling reagent concentration have also been investigated. With the better PPIA method, chromatographic separation of derivatized aromatic amines exhibited a good baseline resolution on an RP column. At the same time, by online mass spectrometric identification with atmospheric pressure chemical ionization (APCI) source in positive ion mode, the PPIA-labeled derivatives were characterized by easy-to-interpret mass spectra due to the prominent protonated molecular ion m/z [M + H](+) and specific fragment ions (MS/MS) m/z 335 and 295. The linear range is 24.41 fmol-200.0 pmol with correlation coefficients in the range of 0.9996-0.9999, and detection limits of PPIA-labeled aromatic amines are 0.12-0.21 nmol/L (S/N = 3). Method repeatability, precision, and recovery were evaluated and the results were excellent for the efficient HPLC analysis. The most important argument, however, was the high sensitivity and ease-of-handling of the PPIA method. Preliminary experiments with wastewater samples collected from the waterspout of a paper mill and its nearby soil where pollution with aromatic amines may be expected show that the method is highly validated with little interference in the chromatogram.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A one-meter long column packed with silica gel is used to separate light hydrocarbons. The silica gel has been modified with several kinds of gas chromatography stationary phases. Among these, PEG 2000 shows fairly good effect when using 80-100 meshes silica gel for the separation of mixture of methane, ethane, ethylene, acetylene, propane, propylene and n-, i-butane. The different behavior of silica gel between batch to batch is also found. When silica gel is coated with a small amount of Al2O3 prepared with sol-gel method, better resolution has been observed on a 2-meter column compared with the non-modified silica gel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The formation of surface alkoxy species on nanosized HZSM-5 and microsized HZSM-5, after exposure to methanol and subsequent conversion to olefins, has been investigated by in situ solid state NMR. Compared to microsized HZSM-5 zeolite, the nanosized HZSM-5 zeolite was found to exhibit a higher affinity for trapping methanol species. Activation of the adsorbed methanol species resulted in the formation of various surface alkoxy species with different rigid characters, including the carboxylate-like surface species, as evidenced by deconvolution of the related spectra. The present results support the existence of the so-called carbon-pool in the conversion of methanol, which serves as the reaction precursor not only for the coupling of the species to form olefins, but also for uncontrolled polymerization to give coke on the surface. The nanosized HZSM-5 shows a distinct resistance to the formation of carbonaceous deposits on the surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A data manipulation method has been developed for automatic peak recognition and result evaluation in the analysis of organic chlorinated hydrocarbons with dual-column gas chromatography. Based on the retention times of two internal standards, pentachlorotoluene and decachlorobiphenyl, the retention times of chlorinated hydrocarbons can be calibrated automatically and accurately. It is very convenient to identify the peaks by comparing the retention times of samples with the calibrated retention times calculated from the relative retention indices of standards. Meanwhile, with a suggested two-step evaluation method the evaluation coefficients and the suitable quantitative results of each component can be automatically achieved for practical samples in an analytical system using two columns with different polarities and two internal standards. (C) 2002 Elsevier Science B.V. All rights reserved.