972 resultados para Photon Counting
Resumo:
The silicon photomultiplier (SiPM) is a novel detector technology that has undergone a fast development in the last few years, owing to its single-photon resolution and ultra-fast response time. However, the typical high dark count rates of the sensor may prevent the detection of low intensity radiation fluxes. In this article, the time-gated operation with short active periods in the nanosecond range is proposed as a solution to reduce the number of cells fired due to noise and thus increase the dynamic range. The technique is aimed at application fields that function under a trigger command, such as gated fluorescence lifetime imaging microscopy.
Resumo:
It is axiomatic that our planet is extensively inhabited by diverse micro-organisms such as bacteria, yet the absolute diversity of different bacterial species is widely held to be unknown. Different bacteria can be found from the depths of the oceans to the top of the mountains; even the air is more or less colonized by bacteria. Most bacteria are either harmless or even advantageous to human beings but there are also bacteria, which can cause severe infectious diseases or spoil the supplies intended for human consumption. Therefore, it is vitally important not only to be able to detect and enumerate bacteria but also to assess their viability and possible harmfulness. Whilst the growth of bacteria is remarkably fast under optimum conditions and easy to detect by cultural methods, most bacteria are believed to lie in stationary phase of growth in which the actual growth is ceased and thus bacteria may simply be undetectable by cultural techniques. Additionally, several injurious factors such as low and high temperature or deficiency of nutrients can turn bacteria into a viable but non-culturable state (VBNC) that cannot be detected by cultural methods. Thereby, various noncultural techniques developed for the assessment of bacterial viability and killing have widely been exploited in modern microbiology. However, only a few methods are suitable for kinetic measurements, which enable the real-time detection of bacterial growth and viability. The present study describes alternative methods for measuring bacterial viability and killing as well as detecting the effects of various antimicrobial agents on bacteria on a real-time basis. The suitability of bacterial (lux) and beetle (luc) luciferases as well as green fluorescent protein (GFP) to act as a marker of bacterial viability and cell growth was tested. In particular, a multiparameter microplate assay based on GFP-luciferase combination as well as a flow cytometric measurement based on GFP-PI combination were developed to perform divergent viability analyses. The results obtained suggest that the antimicrobial activities of various drugs against bacteria could be successfully measured using both of these methods. Specifically, the data reliability of flow cytometric viability analysis was notably improved as GFP was utilized in the assay. A fluoro-luminometric microplate assay enabled kinetic measurements, which significantly improved and accelerated the assessment of bacterial viability compared to more conventional viability assays such as plate counting. Moreover, the multiparameter assay made simultaneous detection of GFP fluorescence and luciferase bioluminescence possible and provided extensive information about multiple cellular parameters in single assay, thereby increasing the accuracy of the assessment of the kinetics of antimicrobial activities on target bacteria.
Resumo:
Les importants progrès dans la qualité et la résolution des images obtenues par «absorptiométrie biphotonique à rayons X» ou DXA ont amélioré certaines modalités existantes et favorisé le développement de nouvelles fonctions permettant d'affiner de manière significative la prise en charge de nos patients dans diverses pathologies. On peut par exemple améliorer la prédiction du risque fracturaire par l'analyse indirecte de la micro et de la macroarchitecture osseuse, rechercher les marqueurs de pathologies associées (recherche de fractures vertébrales ou de fractures fémorales atypiques), ou évaluer le statut métabolique par la mesure de la composition corporelle. Avec les appareils DXA les plus performants, on pourra bientôt déterminer l'âge osseux, estimer le risque cardiovasculaire (par la mesure de la calcification de l'aorte abdominale), ou prédire la progression de l'arthrose articulaire et son évolution après la prise en charge chirurgicale dans la routine clinique. The significant progress on the quality and resolution of the images obtained by "Dual X-ray Absorptiometry" or DXA has permitted on one hand to improve some existing features and on the other to develop new ones, significantly refining the care of our patients in various pathologies. For example, by improving the prediction of fracture risk by indirect analysis of micro- and macro-architecture of the bone, by looking for markers of associated bone diseases (research vertebral fractures or atypical femoral fractures), or by assessing the metabolic status by the measurement of body composition. With the best performing DXA devices we will soon be able, in clinical routine, to determine bone age, to estimate cardiovascular risk (by measuring the calcification of the abdominal aorta) or to predict the progression of joint osteoarthritis and its evolution after surgical management.
Resumo:
This thesis consists of four articles and an introductory section. The main research questions in all the articles are about proportionality and party success in Europe, at European, national or district levels. Proportionality in this thesis denotes the proximity of seat shares parties receive compared to their respective vote shares, after the electoral system’s allocation process. This proportionality can be measured through numerous indices that illustrate either the overall proportionality of an electoral system or a particular election. The correspondence of a single party’s seat shares to its vote shares can also be measured. The overall proportionality is essential in three of the articles (1, 2 and 4), where the system’s performance is studied by means of plots. In article 3, minority party success is measured by advantage-ratios that reveal single party’s winnings or losses in the votes to seat allocation process. The first article asks how proportional are the European parliamentary (EP) electoral systems, how do they compare with results gained from earlier studies and how do the EP electoral systems treat different sized parties. The reasons for different outcomes are looked for in explanations given by traditional electoral studies i.e. electoral system variables. The countries studied (EU15) apply electoral systems that vary in many important aspects, even though a certain amount of uniformity has been aspired to for decades. Since the electoral systems of the EP elections closely resemble the national elections, the same kinds of profiles emerge as in the national elections. The electoral systems indeed treat the parties differentially and six different profile types can be found. The counting method seems to somewhat determine the profile group, but the strongest variables determining the shape of a countries’ profile appears to be the average district magnitude and number of seats allocated to each country. The second article also focuses on overall proportionality performance of an electoral system, but here the focus is on the impact of electoral system changes. I have developed a new method of visualizing some previously used indices and some new indices for this purpose. The aim is to draw a comparable picture of these electoral systems’ changes and their effects. The cases, which illustrate this method, are four elections systems, where a change has occurred in one of the system variables, while the rest remained unchanged. The studied cases include the French, Greek and British European parliamentary systems and the Swedish national parliamentary system. The changed variables are electoral type (plurality changed to PR in the UK), magnitude (France splitting the nationwide district into eight smaller districts), legal threshold (Greece introducing a three percent threshold) and counting method (d’Hondt was changed to modified Sainte-Laguë in Sweden). The radar plots from elections after and before the changes are drawn for all country cases. When quantifying the change, the change in the plots area that is created has also been calculated. Using these radar plots we can observe that the change in electoral system type, magnitude, and also to some extent legal threshold had an effect on overall proportionality and accessibility for small parties, while the change between the two highest averages counting method had none. The third article studies the success minority parties have had in nine electoral systems in European heterogeneous countries. This article aims to add more motivation as to why we should care how different sized parties are treated by the electoral systems. Since many of the parties that aspire to represent minorities in European countries are small, the possibilities for small parties are highlighted. The theory of consociational (or power-sharing) democracy suggests that, in heterogeneous societies, a proportional electoral system will provide the fairest treatment of minority parties. The OSCE Lund Recommendations propose a number of electoral system features, which would improve minority representation. In this article some party variables, namely the unity of the minority parties and the geographical concentration of the minorities were included among possible explanations. The conclusions are that the central points affecting minority success were indeed these non-electoral system variables rather than the electoral system itself. Moreover, the size of the party was a major factor governing success in all the systems investigated; large parties benefited in all the studied electoral systems. In the fourth article the proportionality profiles are again applied, but this time to district level results in Finnish parliamentary elections. The level of proportionality distortion is also studied by way of indices. The average magnitudes during the studied periodrange from 7.5 to 26.2 in the Finnish electoral districts and this opens up unequal opportunities for parties in different districts and affects the shape of the profiles. The intra-country case allows the focus to be placed on the effect of district magnitude, since all other electoral systems are kept constant in an intra-country study. The time span in the study is from 1962 to 2007, i.e. the time that the districts have largely been the same geographically. The plots and indices tell the same story, district magnitude and electoral alliances matter. The district magnitude is connected to the overall proportionality of the electoral districts according to both indices, and the profiles are, as expected, also closer to perfect proportionality in large districts. Alliances have helped some small parties to gain a much higher seat share than their respective vote share and these successes affect some of the profiles. The profiles also show a consistent pattern of benefits for the small parties who ally with the larger parties.
Resumo:
In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.
Resumo:
This chapter presents possible uses and examples of Monte Carlo methods for the evaluation of uncertainties in the field of radionuclide metrology. The method is already well documented in GUM supplement 1, but here we present a more restrictive approach, where the quantities of interest calculated by the Monte Carlo method are estimators of the expectation and standard deviation of the measurand, and the Monte Carlo method is used to propagate the uncertainties of the input parameters through the measurement model. This approach is illustrated by an example of the activity calibration of a 103Pd source by liquid scintillation counting and the calculation of a linear regression on experimental data points. An electronic supplement presents some algorithms which may be used to generate random numbers with various statistical distributions, for the implementation of this Monte Carlo calculation method.
Resumo:
UNLABELLED: Trabecular bone score (TBS) seems to provide additive value on BMD to identify individuals with prevalent fractures in T1D. TBS did not significantly differ between T1D patients and healthy controls, but TBS and HbA1c were independently associated with prevalent fractures in T1D. A TBS cutoff <1.42 reflected prevalent fractures with 91.7 % sensitivity and 43.2 % specificity. INTRODUCTION: Type 1 diabetes (T1D) increases the risk of osteoporotic fractures. TBS was recently proposed as an indirect measure of bone microarchitecture. This study aimed at investigating the TBS in T1D patients and healthy controls. Associations with prevalent fractures were tested. METHODS: One hundred nineteen T1D patients (59 males, 60 premenopausal females; mean age 43.4 ± 8.9 years) and 68 healthy controls matched for gender, age, and body mass index (BMI) were analyzed. The TBS was calculated in the lumbar region, based on two-dimensional (2D) projections of DXA assessments. RESULTS: TBS was 1.357 ± 0.129 in T1D patients and 1.389 ± 0.085 in controls (p = 0.075). T1D patients with prevalent fractures (n = 24) had a significantly lower TBS than T1D patients without fractures (1.309 ± 0.125 versus 1.370 ± 0.127, p = 0.04). The presence of fractures in T1D was associated with lower TBS (odds ratio = 0.024, 95 % confidence interval (CI) = 0.001-0.875; p = 0.042) but not with age or BMI. TBS and HbA1c were independently associated with fractures. The area-under-the curve (AUC) of TBS was similar to that of total hip BMD in discriminating T1D patients with or without prevalent fractures. In this set-up, a TBS cutoff <1.42 discriminated the presence of fractures with a sensitivity of 91.7 % and a specificity of 43.2 %. CONCLUSIONS: TBS values are lower in T1D patients with prevalent fractures, suggesting an alteration of bone strength in this subgroup of patients. Reliable TBS cutoffs for the prediction of fracture risk in T1D need to be determined in larger prospective studies.
Resumo:
La presente entrega de la serie de Nursing sobre las pruebas complementarias está dedicada a la tomografía computarizada (TC). La TC fue pensada inicialmente para explorar el encéfalo en profundidad, pero su capacidad diagnóstica ha caracterizado su evolución desde sus inicios a principios de la década de los setenta, cuando el ingeniero británico Sir Godfrey Newbold Hounsfield ideó el primer prototipo de TC. En la actualidad se utiliza para la exploración y estudio de prácticamente la totalidad de órganos y tejidos. La TC se caracteriza por tener una elevada capacidad de discriminación en las estructuras anatómicas en función de su densidad. Esto permite diferenciar órganos, tejidos y sus lesiones, ofreciendo la posibilidad de obtener más información de la que mostraba la imagen radiológica convencional, que se caracterizaba por la obtención de una imagen general de la estructura a estudiar. En el caso de la TC, uno de los aspectos más destacados es la adquisición axial de la imagen, que permite estudiar porciones de anatomía. La capacidad de visión multiplanar de los nuevos equipos multicoronas, junto con la capacidad de diferenciar densidades, la convierten en una poderosa herramienta diagnóstica. Desde el punto de vista de atención al paciente, la enfermera explica e informa sobre la dinámica de las exploraciones que, dadas las características de la TC, hacen imprescindible el conocimiento de las preparaciones y los cuidados durante y después de la técnica para que se resuelvan de manera eficaz y sin molestias para el paciente.
Resumo:
Pressurized re-entrant (or 4 pi) ionization chambers (ICs) connected to current-measuring electronics are used for activity measurements of photon emitting radionuclides and some beta emitters in the fields of metrology and nuclear medicine. As a secondary method, these instruments need to be calibrated with appropriate activity standards from primary or direct standardization. The use of these instruments over 50 years has been well described in numerous publications, such as the Monographie BIPM-4 and the special issue of Metrologia on radionuclide metrology (Ratel 2007 Metrologia 44 S7-16, Schrader1997 Activity Measurements With Ionization Chambers (Monographie BIPM-4) Schrader 2007 Metrologia 44 S53-66, Cox et al 2007 Measurement Modelling of the International Reference System (SIR) for Gamma-Emitting Radionuclides (Monographie BIPM-7)). The present work describes the principles of activity measurements, calibrations, and impurity corrections using pressurized ionization chambers in the first part and the uncertainty analysis illustrated with example uncertainty budgets from routine source-calibration as well as from an international reference system (SIR) measurement in the second part.
Resumo:
La presente entrega de la serie de Nursing sobre las pruebas complementarias está dedicada a la tomografía computarizada (TC). La TC fue pensada inicialmente para explorar el encéfalo en profundidad, pero su capacidad diagnóstica ha caracterizado su evolución desde sus inicios a principios de la década de los setenta, cuando el ingeniero británico Sir Godfrey Newbold Hounsfield ideó el primer prototipo de TC. En la actualidad se utiliza para la exploración y estudio de prácticamente la totalidad de órganos y tejidos. La TC se caracteriza por tener una elevada capacidad de discriminación en las estructuras anatómicas en función de su densidad. Esto permite diferenciar órganos, tejidos y sus lesiones, ofreciendo la posibilidad de obtener más información de la que mostraba la imagen radiológica convencional, que se caracterizaba por la obtención de una imagen general de la estructura a estudiar. En el caso de la TC, uno de los aspectos más destacados es la adquisición axial de la imagen, que permite estudiar porciones de anatomía. La capacidad de visión multiplanar de los nuevos equipos multicoronas, junto con la capacidad de diferenciar densidades, la convierten en una poderosa herramienta diagnóstica. Desde el punto de vista de atención al paciente, la enfermera explica e informa sobre la dinámica de las exploraciones que, dadas las características de la TC, hacen imprescindible el conocimiento de las preparaciones y los cuidados durante y después de la técnica para que se resuelvan de manera eficaz y sin molestias para el paciente.
Resumo:
In diffusion MRI, traditional tractography algorithms do not recover truly quantitative tractograms and the structural connectivity has to be estimated indirectly by counting the number of fiber tracts or averaging scalar maps along them. Recently, global and efficient methods have emerged to estimate more quantitative tractograms by combining tractography with local models for the diffusion signal, like the Convex Optimization Modeling for Microstructure Informed Tractography (COMMIT) framework. In this abstract, we show the importance of using both (i) proper multi-compartment diffusion models and (ii) adequate multi-shell acquisitions, in order to evaluate the accuracy and the biological plausibility of the tractograms.
Resumo:
Międzyrzecz Fortified Front, were Natura 2000 site PLH080003 Nietoperek is situated, was built by the Germans in the 1930s and during the World War II. It is composed of above ground bunkers connected by underground tunnels of ca. 32 km total length. Nietoperek is the eighth largest bats hibernation site in EU. Monthly censuses were carried out from October to April during three consecutive winter seasons (2011/12 – 2013/14) in area covering ca. 30% of the undergrounds. The aims of the study were: (1) to describe changes in numbers of each species in the course of hibernation season, (2) to suggest deadlines for counting particular bat species to obtain maximal numbers and (3) to describe negative impact of tourism on hibernating bats. The results will be useful for restriction of winter tourism in Nietoperek. The total number of bats observed during the study was 37869 individuals of 9 species. Because of difficulties in distinguishing without handling M. mystacinus and M. brandtii were treated as one group. M. myotis constituted from 53% (first season) to 64% (last season) of all hibernating bats. The maximal numbers of individuals were observed in November (first two seasons) and in December (third season). M. daubentonii constituted from 27% (first season) to 21% (last season) and M. nattereri from 10% (first season) to 11% (second season) of all bats. During the three seasons the maximal numbers of M. daubentonii and M. nattereri were observed in November and December respectively. B. barbastellus and P. auritus constituted from 4% (first season) to 2% (last season) of the multi species colony. The maximal numbers of B. barbastellus were observed in January and P. auritus in January (first and second seasons) and in December (third season). Results indicated that the best period for counting maximal numbers of M. myotis and M. daubentonii is November, for M. nattereri is December and for B. barbastellus and P. auritus is January. The study undertaken in the part visited by tourists in winter (total length of 900 m) proved negative effect caused by human disturbance with 23% decline of total bat numbers.
Resumo:
BACKGROUND: The counting of poorly differentiated clusters of 5 or more cancer cells lacking a gland-like structure in a tumor mass has recently been identified among the histological features predictive of poor prognosis in colorectal cancer. MAIN BODY: Poorly differentiated clusters can easily be recognized in the histological sections of colorectal cancer routinely stained with haematoxylin and eosin. Despite some limitations related to specimen fragmentation, counting can also be assessed in endoscopic biopsies. Based on the number of poorly differentiated clusters that appear under a microscopic field of a ×20 objective lens (i.e., a microscopic field with a major axis of 1 mm), colorectal cancer can be graded into malignancies as follows: tumors with <5 clusters as grade 1, tumors with 5 to 9 clusters as grade 2, and tumors with ≥10 clusters as grade 3. High poorly differentiated cluster counts are significantly associated with peri-neural and lympho-vascular invasion, the presence of nodal metastases or micrometastases, as well as shorter overall and progression free survival to colorectal cancer. CONCLUSION: The morphological aspects and clinical relevance of poorly differentiated clusters counting in colorectal cancer are discussed in this review.
Resumo:
With the steep increase in the use of cross-sectional imaging in recent years, the incidentally detected adrenal lesion, or "incidentaloma", has become an increasingly common diagnostic problem for the radiologist, and a need for an approach to classifying these lesions as benign, malignant or indeterminate with imaging has spurred an explosion of research. While most incidentalomas represent benign disease, typically an adenoma, the possibility of malignant involvement of the adrenal gland necessitates a reliance on imaging to inform management decisions. In this article, we review the literature on adrenal gland imaging, with particular emphasis on computed tomography, magnetic resonance imaging, and photon-emission tomography, and discuss how these findings relate to clinical practice. Emerging technologies, such as contrast-enhanced ultrasonography, dual-energy computed tomography, and magnetic resonance spectroscopic imaging will also be briefly addressed.